• Title/Summary/Keyword: calibration coefficients

Search Result 328, Processing Time 0.025 seconds

Experimental Validation of Ornithopter Aerodynamic Model in Low Reynolds Number Regime (저 레이놀즈 수 영역에서 날갯짓 비행체 공력 모델의 실험적 검증)

  • Lee, Jun-Seong;Kim, Dae-Kwan;Han, Jae-Hung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.7
    • /
    • pp.647-654
    • /
    • 2010
  • In this study, an efficient ornithopter aerodynamic model, which is applicable to ornithopter wing design considering fluid-structure interaction or ornithopter flight dynamics and control simulation, was proposed and experimentally validated through the wind tunnel experiments. Due to the ornithopter aerodynamics governed by unsteady low Reynolds number flow, an experimental device was specially designed and developed. A part of the experimental device, 2-axis loadcell, was situated in the non-inertial frame; the dynamic calibration method was established to compensate the inertial load for pure aerodynamic load measurements. The characteristics of proposed aerodynamic model were compared with the experimental data in terms of mean and root-mean-square values of lift and drag coefficients with respect to the flow speed, flapping frequency, and fixed angle of attack.

Pharmacokinetic Analysis of Montelukast in Healthy Korean Volunteers by High Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Jo, Min-Ho;Park, Mi-Sun;Seo, Ji-Hyung;Shim, Wang-Seob;Yim, Sung-Vin;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.5
    • /
    • pp.289-294
    • /
    • 2011
  • A rapid and specific high performance liquid chromatography-tandem mass (LC/MS/MS) method for the analysis of montelukast in human plasma has been developed and validated. After cold acetonitrile-induced precipitation of the plasma samples, montelukast and glipizide (internal standard, IS) were eluted on a reverse-phase $C_{18}$ column by isocratic mobile phase consisted of 10 mM ammonium formate buffer (adjusted to pH 3.5 with formic acid) and acetonitrile (3:97, v/v). Acquisition was performed with multiple reaction monitoring (MRM) mode by monitoring the transitions: m/z 587.2${\rightarrow}$ 423.2 for montelukast and m/z 446.0${\rightarrow}$321.2 for IS. Ranges of concentration for calibration curves (10-1000 ng/mL) showed correlation coefficients ($r^2$) were better than 0.9948. Precision of intra- and inter-day ranged from 3.70 to 11.68% and from 3.04 to 12.95%, accuracy of intra-day and inter-day ranged from 93.34 to 102.75% and from 100.79 to 107.63%, respectively. The described method provides a fast and sensitive analytical tool for determining montelukast levels in plasma, and was successfully applied to a pharmacokinetic study in 16 healthy human subjects after oral administration of 10mg tablet formulation of montelukast sodium under fasting conditions.

HPLC Analysis of Organic Acids, Phenol, and Benzopyrene in Wood Vinegar (HPLC에 의한 목초액 중의 유기산, 페놀 및 벤조피렌의 분석법 개발)

  • Lee, Gye-Won;Kim, A-Ram;Cho, Jae-Soo
    • YAKHAK HOEJI
    • /
    • v.52 no.1
    • /
    • pp.12-19
    • /
    • 2008
  • The organic acids (formic acid, acetic acid and propionic acid), phenol and benzopyrene in wood vinegar were determine by HPLC. An $Atlantis^{TM}dC_{18}$ column with a acetonitrile: 0.1% phosphoric acid (5: 95, organic acids), acetonitrile: water (10 : 90, phenol), 100% acetonitrile (benzopyrene) as a mobile phase was used. Retention time of acetic acid, formic acid, propionic acid, phenol and benzopyrene was 4.77, 3.73, 9.08, 30.97 and 6.10 min, respectively. The calibration curves of organic acids, phenol, benzopyrene were linear over the concentration range of $30{\sim}500,\;60{\sim}1000$, and $3{\sim}50\;{\mu}g/ml$ with correlation coefficient of above 0.999. The limit of detection (LOD) and limit of quantitation (LOQ) of acetic acid, formic acid, propionic acid, phenol, and benzopyrene was 1.71 and 5.19, 1.11 and 3.35, 4.87 and 14.74, 6.45 and 19.55, 0.08 and $0.24\;{\mu}g/ml$, respectively. The coefficients of variation for intra- and inter-day assay were $0.21{\sim}4.14$ and $0.07{\sim}1.19%$, respectively and the precision was $95{\sim}115%$. From this study, we suggest that HPLC is suitable method for the determination of organics in wood vinegar and could be applied to quality control of wood vinegar.

Development and Calibration of a Permanent Deformation Model for Asphalt Concrete Based on Shear Properties (아스팔트 콘크리트의 전단 물성을 고려한 영구변형 모형 개발 및 보정)

  • Lee, Hyun-Jong;Baek, Jong-Eun;Li, Qiang
    • International Journal of Highway Engineering
    • /
    • v.13 no.4
    • /
    • pp.61-70
    • /
    • 2011
  • This study developed a permanent deformation model for asphalt concrete based on shear properties. Repeated load triaxial compression (RLTC), triaxial compressive strength, and indirect tension strength tests were performed for the three types of asphalt mixtures at various loading and temperature conditions to correlate shear properties of asphalt mixtures to rutting performance. For the given mixtures, as testing temperature increased, cohesion decreased, but friction angle was insensitive to temperature at $40^{\circ}C$ or higher. It was observed that deviatoric stress, confining pressure, temperature, and load frequency affected the permanent deformation of asphalt mixtures significantly. The permanent deformation model based on shear stress to strength ratio and loading time was developed using the laboratory test results and calibrated using accelerated pavement test data. The proposed model was able to predict the permanent deformation of the asphalt mixtures in a wide range of loading and temperature conditions with constant model coefficients.

Measurement of Backscattering Coefficients of Rice Canopy using a Polarimetric Scatterometer System (Polarimetric Scatterometer 시스템을 이용한 벼 군락의 후방산란계수 측정)

  • Hong, Suk-Young;Hong, Jin-Young;Kim, Yi-Hyun;Oh, Yi-Sok
    • Proceedings of the KSRS Conference
    • /
    • 2007.03a
    • /
    • pp.153-157
    • /
    • 2007
  • 본 논문은 지표면 현상의 관측에 날씨의 영향을 거의 받지 않는 마이크로파 L-밴드(1.95 GHz)와 C-밴드(5.3 GHz) scatterometer 시스템을 이용하여 농업과학기술원 내의 논에서 자라는 추청벼를 대상으로 2006년 5월 29일부터 10월 9일까지 생육에 따른 군락의 후방산란계수를 관측한 데이터와 작물의 생육과의 관계를 살펴보고 또한,측정 시스템의 개요,측정 시스템의 보정 방법들을 기술하고자 한다. Scatterometer 시스템의 송 수신기로 HP 8753D 벡터 네트워크 분석기를 사용하며,타워 위에 안테나를 설치하여 3.4 m의 높이에서 측정하도록 하였다. L-밴 드와 C-밴드 scatterometer는 VV-, VH-, HV-, HH-편파를 측정하여 fully polarimetric한 데이터를 얻도록 설계된 레이더시스템으로 입사각을 $30^{\circ}{\sim}60^{\circ}$에서 $10^{\circ}$간격으로 각각 30개의 독립적인 샘플을 측정하여 통계적으로 후방산란계수를 얻었다. 타워에서 발생하는 전파 잡음과 안테나 패턴의 부엽에 의한 지면에서의 수직반사(coherent 성분) 전파를 제거하기 위해 네트워크 분석기의 time gating 기능을 사용하며,55 cm 크기의 trihedral 전파반사기를 보정용 반사기로 사용하고, STCT(single target calibration technique) 방법을 이용하여 시스템을 보정하였다. 측정 결과를 분석하여 주파수, 입사각도, 편파의 변화에 대한 벼의 후방산란 특성과 벼의 생육상태과의 관계를 살펴보았다. L-밴드와 C-밴드 모두 벼의 생육과 밀접한 결과를 나타내었으나,입사각이 작을 때는 C-밴드와의 상관이 높게 나타났고 입사각이 커질수록 L-밴드와의 상관이 높게 나타났다. 편파는 L-밴드 와 C-밴드 모두 hh 편파가,입사각은 50도에서 가장 생육의 변이를 잘 설명하는 것으로 나타났다. 생육 데이터 모두를 이용한 경우보다는 유수형성기 또는 출수기 등 벼 생육의 질적인 변화를 보이는 시기에 따라 나누어 분석하는 것이 변화추이를 더 잘 설명하는 것으로 나타났다.

  • PDF

The Distribution of Nitrogen and the Decomposition Rate of Organic Nitrogen in the Youngsan River and the Sumjin River, Korea (영산강과 섬진강 수계의 질소 분포와 유기질소 분해속도)

  • Kim, Jihye;Kim, Bomchul;Shin, Myoungsun;Kim, Jaiku;Jung, Sungmin;Lee, Yunkyoung;Park, Juhyun
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.1
    • /
    • pp.142-150
    • /
    • 2009
  • The distribution of organic nitrogen and its decomposition rate were studied in the Youngsan River and the Sumjin River system in Korea. Samples were conducted seasonally in June, August, December of 2006, and February of 2007. Collected samples were incubated for 20 days in a dark chamber ($20{\pm}1^{\circ}C$) and analyzed the changes of nitrogen form (particulate organic nitrogen, dissolved organic nitrogen, ammonia, nitrite, and nitrate). The mean total nitrogen (TN) concentration in the Youngsan River and the Sumjin River were $2.62mgN{\cdot}L^{-1}$ and $1.53mgN{\cdot}L^{-1}$, respectively. TN comprised of 65% DIN and 35% ON. The decomposition coefficients of organic nitrogen were also determined by two different fitting models. The decomposition rates of nitrogen species (TON, LPON, LDON, ${NH_4}^+$ and ${NO_2}^-$) ranged from 0.024 to $1.043day^{-1}$ in the Youngsan River and 0.008 to $0.693day^{-1}$ in the Sumjin River, respectively. The result of this study can give a guide to the selection of parameters in the calibration processes of water quality models.

Evaluation on Extraction Conditions and HPLC Analysis Method for Ginsenosides in Panax ginseng (인삼의 추출조건 및 진세노사이드의 HPLC 분석법 평가)

  • Lee, Kyeong Hee;Lee, Dae Young;Lee, Seung Eun;Nam, Ki Yeul;Hwang, Gwang Bo;Kim, Hyung Don;Lee, Jae Won;Choi, Je Hun;Ahn, Young Sup;Kim, Seung Yu;Kim, Geum Soog
    • Korean Journal of Medicinal Crop Science
    • /
    • v.24 no.1
    • /
    • pp.47-54
    • /
    • 2016
  • Background : A new extraction method-heated ultrasonic extraction was qualitatively and quantitatively analyzed for the extraction of major ginsenosides from ginseng extract; this new high-performance liquid chromatography (HPLC) method was compared with the official extraction method of Korean industrial standards and standard for health functional food. Methods and Results : Ginsenoside compounds were analyzed for 35 minutes by the new HPLC analysis method using a Halo$^{(R)}$ RP-Amide column. The new HPLC analysis method was validated by the measurement of intra-day and inter-day precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) of each ginsenoside. The correlation coefficients (r2) for the calibration curves of the ginsenoside compounds were over 0.9997 in terms of linearity. The heated ultrasonic extraction method using ultrasonication for 30 minutes at $50^{\circ}C$ yielded higher amount of ginsenosides than the extraction method of the Korean industrial standards owing to the enhancement of extraction efficiency. Conclusions : Compared to the other extraction methods, the heated ultrasonic extraction method yielded a higher amount of ginsenoside Rb1 than Rg1 index compounds for the quality evaluation of ginseng roots.

Effect of Ethanol on the Protolytic Properties of the Vitamins B Group

  • Ghasemi, J.;Shiri, F.
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.1
    • /
    • pp.21-30
    • /
    • 2007
  • A multiwavelength spectrophotometric titration method was applied to study protolytic constants of four water-soluble vitamins, folic acid(vitamin B9 or B0), thiamine(vitamin B1), riboflavin(vitamin B2) and pyridoxal (vitamin B6) in binary ethanol-water mixtures at 25oC and an ionic strength of 0.1M NaNO3. The protolytic equilibrium constants, spectral profiles, concentration diagrams and also the number of components has been calculated from the curve fitting of the pH-absorbance data with appropriate mass balance equations by an established factor analysis model. DATAN program was used for determination of acidity constant and SPECFIT program was used for calculation of standard deviations and partial correlation coefficients. A glass electrode calibration procedure based on the four parameter equation pH=α+SpcH+JH+[H+]+ JOH-Kw/[H+] based on the Gran,s plots was used to obtain pH-readings in the concentration scale (pcH). The effect of the solvent on the protolytic constants was discussed.

Theory of a Current-Type Electromagnetic Flowmeter for Two-Phase Flow and Numerical Computation of the 3D Virtual Potential Distributions for Annular Flow (2상류용 전류형식 전자기유량계 이론 및 환상류에서의 3차원 가상포텐셜 분포의 수치적 계산)

  • Oh, Byung-Do;Kim, Moo-Hwan;Ahn, Yeh-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.714-725
    • /
    • 2003
  • The theory of the current-type electromagnetic flowmeter for a high temporal resolution was developed for two-phase flow measurements. To predict the output of the current-type flowmeter, the three-dimensional virtual potential distribution C and the newly introduced flow pattern coefficient f were derived and computed. The output of flowmeter depends on the liquid conductivity (sensitive to temperature) and flow configurations of the two-phase flow with the sinusoidal excitation over 100 Hz. The flow pattern coefficient was specially devised to separate the dependency on the flow configuration of the two-phase flow from that on the liquid conductivity which can be expressed with the calibration of single-phase flow. Using the finite difference method, the three-dimensional virtual potential distributions were computed for the electrode of finite size. By taking derivative of the virtual potential, the weight functions were evaluated and compared with existing analytic series solution for the point-electrode. There was a reasonable correspondence between the present and existing results. In addition, the flow pattern coefficients were evaluated for annular flows with various film thicknesses, and compared with the experimental results by the impedance spectroscopy. The numerical results agreed well with the experimental data.

Determination of Ginseng Saponins by Reversed-Phase High Performance Liquid Chromatography (역상 고속액체크로마토그라피를 이용한 홍삼 사포닌의 정량)

  • Kim, Cheon-Suk;Kim, Se-Bong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.9 no.1
    • /
    • pp.21-25
    • /
    • 2001
  • Major saponins in ginseng were analysed using reverse phase high performance liquid chromatography with binary mobile phase gradient control system instead of normal phase column. The optimum condition were as following : reverse phase column; ${\mu}{\beta}ondapak\;C_{18}$ column (Waters, $3.9mm{\times}300\;mm,\;5{\mu}m$), methyl cyanaide/water binary mobile phase gradient control system, solvent flow rate; 1.5 ml/min, and UV($203{\mu}m$ ) detector. The complete separation of ginsenoside $Rb_1,\;Rb_2,\;Rc,\;Rd,\;Re,\;Rf\;and\;Rg_1$ was achieved within 55 min. The Regression coefficients of the calibration curves for seven ginsenosides were 0.99.

  • PDF