• Title/Summary/Keyword: calibration coefficients

Search Result 328, Processing Time 0.025 seconds

3.5 mm Coaxial One Port Vector Network Analysis Using Time Domain Reflectometry (반사 펄스의 주파수 해석을 이용한 광대역 3.5 mm 동축형 단일 포트 벡터 회로망 분석법)

  • Lee, Dong-Joon;Kwon, Jae-Yong;So, Joon-Ho;Kang, No-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.8
    • /
    • pp.967-975
    • /
    • 2012
  • This paper presents a method to measure reflection coefficients of microwave devices or antennas based on time domain analysis with sampling oscilloscopes. The reflection coefficients were extracted by the Fourier transformation of echo pulses from devices with respect to the 20 GHz incident pulse signals. The three-error terms, which are commonly used for the correction of a microwave network, were determined using a 3.5 mm calibration kit. In addition, a modified error-correction model associated with a directional coupler for reflection coefficient measurements is introduced. The results were compared with those of measured with a commercial vector network analyzer.

Quantitation of Flurbiprofen in Isopropyl Myristate by High Performance Liquid Chromatography (고속액체크로마토그래피를 이용한 미리스틴산이소프로필증 플루르비프로펜의 정량)

  • Kim, Hyun;Chi, Sang-Cheol
    • Journal of Pharmaceutical Investigation
    • /
    • v.22 no.1
    • /
    • pp.63-68
    • /
    • 1992
  • An HPLC procedure with UV detection has been developed for the quantitation of flurbiprofen released into isopropyl myristate used as the receptor phase in an in vitro membraneless drug diffusion cell. The drug and the internal standard (oxaprozin) were extracted from isopropyl myristate with a mixture of dimethylsulfoxide:methanol:water (2:1:1) and quantitated using a reverse phase $C_{18}$ column. The chromatograms were completely free from interfering peaks, and the relative retention times of flurbiprofen and the internal standard were 4.9 and 6.8 min, respectively. Calibration plots were linear over the concentration range of $1-200\;{\mu}g/ml$ of flurbiprofen with correlation coefficients, all higher than 0.99. The mean intra-day precision and accuracy among three replicate sets of the assay in a day were 4.26 and 4.52%, respectively, whereas the mean inter-day precision and accuracy were 3.35 and 3.64%, respectively. The mean recovery of the drug was 92.5% over the calibration range. The method was simple, reliable and accurate for the quantitation of flurbiprofen in unpurified isopropyl myristate.

  • PDF

Image Processing Methods for Measurement of Lettuce Fresh Weight

  • Jung, Dae-Hyun;Park, Soo Hyun;Han, Xiong Zhe;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.40 no.1
    • /
    • pp.89-93
    • /
    • 2015
  • Purpose: Machine vision-based image processing methods can be useful for estimating the fresh weight of plants. This study analyzes the ability of two different image processing methods, i.e., morphological and pixel-value analysis methods, to measure the fresh weight of lettuce grown in a closed hydroponic system. Methods: Polynomial calibration models are developed to relate the number of pixels in images of leaf areas determined by the image processing methods to actual fresh weights of lettuce measured with a digital scale. The study analyzes the ability of the machine vision- based calibration models to predict the fresh weights of lettuce. Results: The coefficients of determination (> 0.93) and standard error of prediction (SEP) values (< 5 g) generated by the two developed models imply that the image processing methods could accurately estimate the fresh weight of each lettuce plant during its growing stage. Conclusions: The results demonstrate that the growing status of a lettuce plant can be estimated using leaf images and regression equations. This shows that a machine vision system installed on a plant growing bed can potentially be used to determine optimal harvest timings for efficient plant growth management.

Design and Evaluation of the Control Performance of a Compliant Arm Support (중력 보상 팔 기능 지지대의 설계 및 제어 성능 평가)

  • Kim, Sang-Hun;Jeong, Useok;Park, Daegeun;Koo, Inwook;Cho, Kyu-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.2
    • /
    • pp.115-123
    • /
    • 2017
  • This paper presents the design and the control performance of a novel dynamic compliant-arm support with parallel elastic actuators that was developed to assist with the daily living activities of those whose arms are compromised by muscular disease or the aging process. The parallel elastic-arm support consists of a compliant mechanism with combined passive and active components for human interaction and to reach the user's desired positions. The achievement of these tasks requires impedance control, which can change the virtual stiffness, damping coefficients, and equilibrium points of the system; however, the desired-position tracking by the impedance control is limited when the end-effector weight varies according to the equipping of diverse objects. A prompt algorithm regarding weight calibration and friction compensation is adopted to overcome this problem. A result comparison shows that, by accurately assessing the desired workspace, the proposed algorithm is more effective for the accomplishment of the desired activities.

Estimation of Pollutant Load Using Genetic-algorithm and Regression Model (유전자 알고리즘과 회귀식을 이용한 오염부하량의 예측)

  • Park, Youn Shik
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.1
    • /
    • pp.37-43
    • /
    • 2014
  • BACKGROUND: Water quality data are collected less frequently than flow data because of the cost to collect and analyze, while water quality data corresponding to flow data are required to compute pollutant loads or to calibrate other hydrology models. Regression models are applicable to interpolate water quality data corresponding to flow data. METHODS AND RESULTS: A regression model was suggested which is capable to consider flow and time variance, and the regression model coefficients were calibrated using various measured water quality data with genetic-algorithm. Both LOADEST and the regression using genetic-algorithm were evaluated by 19 water quality data sets through calibration and validation. The regression model using genetic-algorithm displayed the similar model behaviors to LOADEST. The load estimates by both LOADEST and the regression model using genetic-algorithm indicated that use of a large proportion of water quality data does not necessarily lead to the load estimates with smaller error to measured load. CONCLUSION: Regression models need to be calibrated and validated before they are used to interpolate pollutant loads, as separating water quality data into two data sets for calibration and validation.

Uncertainty in the Course of Calibration of RF Multimeter using TVC (열전압변환기를 이용한 고주파전압계의 교정과 측정불확도)

  • 박정규;박석주;이환상;장경승;박명선
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.1
    • /
    • pp.47-52
    • /
    • 2002
  • It was virtually declared that measurement science must abandon the error analysis of measurement when ISO had published "Guide to Expression of uncertainty in Measurement" International inclination of measurement field in order to guarantee the traceability and confidence of measurement results discards the error concept and instead analyzes the measurement uncertainty. In this paper we establish a mathematical model of measurement and analyze all uncertainty factors as possible as for yielding the measurement uncertainty in the course of the calibration of RF multimeter using Transfer Standard, Thermal Voltage Converter We produce the expanded uncertainty by analyzing cable effects, correlation of thermocoupler and DC meter, DC source, RF source, attenuator, reflection coefficients and DUT.s and DUT.

Improved Interpolating Equation for Industrial Platinum Resistance Thermometer (산업용 백금저항온도계를 위한 향상된 내삽식)

  • Yang, In-Seok;Kim, Yong-Gyoo;Gam, Kee-Sool;Lee, Young-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.109-113
    • /
    • 2012
  • We propose an improved interpolating equation to express temperature-resistance characteristics for modern industrial platinum resistance thermometers (PRTs). Callendar-van Dusen equation which has been widely used for platinum resistance thermometer fails to fully describe temperature characteristics of high quality PRTs and leaves systematic residual when the calibration point include temperatures above $300^{\circ}C$. Expanding Callendar-van Dusen to higher-order polynomial drastically improves the uncertainty of the fitting even with reduced degrees of freedom of the fitting. We found that in the fourth-order polynomial fitting, the third-order and fourth-order coefficients have a strong correlation. Using the correlation, we suggest an improved interpolating equation in the form of fourth-order polynomial, but with three fitting parameters. Applying this interpolating equation reduced the uncertainty of the fitting to 32 % of that resulted from the traditional Callendar-van Dusen. This improvement was better than that from a simple third-order polynomial despite that the degrees of the freedom of the fitting was the same.

Measurement of Alcohol Contents in Alcoholic Beverages Using a Surface Plasmon Resonance Sensor (표면 플라즈몬 공명 센서를 이용한 주류의 알코올 함량 측정)

  • 조용진;안병학;김철진;김종태
    • Journal of Biosystems Engineering
    • /
    • v.29 no.4
    • /
    • pp.323-328
    • /
    • 2004
  • A surface plasmon resonance (SPR) sensing system, which belonged to a family of thin film refractometry-based sensors, was fabricated to measure the alcohol contents in alcoholic beverages. In this study, a SPR owe was obtained by a photodiode array with 128 pixels and transformed into a refractive index which was calculated by means of the first moment of values below a baseline of 0.85. When the sensing system was applied to Soju, Cheonju, Igwaduju and Tacju highly linear relationships between the refractive index by SPR and the contents of alcohol were obtained. That is, the coefficients of determination in their linear models were 0.992, 0.933, 0.918 and 0.954, respectively. Meanwhile, the effect of sample preparations on the accuracy of measurement was analyzed. As for Soju and Tacju, the best calibration equations were obtained when no sample preparation was applied. The best calibration models for measurement of Cheonju and Igwaduju were obtained through the samples filtered by $C_{18}$ disks.

Measurement of Backscattering Coefficients of Rice Canopy Using a Ground Polarimetric Scatterometer System (지상관측 레이다 산란계를 이용한 벼 군락의 후방산란계수 측정)

  • Hong, Jin-Young;Kim, Yi-Hyun;Oh, Yi-Sok;Hong, Suk-Young
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.2
    • /
    • pp.145-152
    • /
    • 2007
  • The polarimetric backscattering coefficients of a wet-land rice field which is an experimental plot belong to National Institute of Agricultural Science and Technology in Suwon are measured using ground-based polarimetric scatterometers at 1.8 and 5.3 GHz throughout a growth year from transplanting period to harvest period (May to October in 2006). The polarimetric scatterometers consist of a vector network analyzer with time-gating function and polarimetric antenna set, and are well calibrated to get VV-, HV-, VH-, HH-polarized backscattering coefficients from the measurements, based on single target calibration technique using a trihedral corner reflector. The polarimetric backscattering coefficients are measured at $30^{\circ},\;40^{\circ},\;50^{\circ}\;and\;60^{\circ}$ with 30 independent samples for each incidence angle at each frequency. In the measurement periods the ground truth data including fresh and dry biomass, plant height, stem density, leaf area, specific leaf area, and moisture contents are also collected for each measurement. The temporal variations of the measured backscattering coefficients as well as the measured plant height, LAI (leaf area index) and biomass are analyzed. Then, the measured polarimetric backscattering coefficients are compared with the rice growth parameters. The measured plant height increases monotonically while the measured LAI increases only till the ripening period and decreases after the ripening period. The measured backscattering coefficientsare fitted with polynomial expressions as functions of growth age, plant LAI and plant height for each polarization, frequency, and incidence angle. As the incidence angle is bigger, correlations of L band signature to the rice growth was higher than that of C band signatures. It is found that the HH-polarized backscattering coefficients are more sensitive than the VV-polarized backscattering coefficients to growth age and other input parameters. It is necessary to divide the data according to the growth period which shows the qualitative changes of growth such as panicale initiation, flowering or heading to derive functions to estimate rice growth.

Non-Destructive Prediction of Head Rice Ratios using NIR Spectra of Hulled Rice (정조 상태에서 백미에 대한 완전미율의 비파괴 예측)

  • Kwon, Young-Rip;Cho, Seung-Hyun;Lee, Jae-Heung;Seo, Kyoung-Won;Choi, Dong-Chil
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.3
    • /
    • pp.244-250
    • /
    • 2008
  • The purpose of this study was to measure fundamental data required for the prediction of milling ratios, and to develop regression models to predict the head rice ratio of milled rice using NIR spectra of hulled rice. A total of 81 rice samples used in this study were collected from Jeongeup, Jeonbuk province in 2006. NIR spectra were measured using one mode of measurement, reflection. The reflectance spectra were measured in the wavelength region of 400-2500 nm with an NIR spectrophotometer "NIRSystems 6500" (Foss, Silverspring, USA). Calibration equations were developed by the modified partial least squares (MPLS), partial least squares (PLS), and principal components regression (PCR). Math treatments were 1-4-4-1, 1-10-10-1, 2-4-4-1, and 2-10-10-1. The software used was WinISI (Infrasoft International, State College, USA). Automatic head rice production and quality checking system used was "SY2000-AHRPQCS" (Ssangyong, Korea). The calibration was made with the first derivative and the spectrum designated was in 8 nm interval. The determination coefficients of head rice ratios were 0.8353, 0.8416 and 0.5277 for the MPLS, PLS and PCR, respectively. Those obtained with 20 nm interval were 0.8144, 0.8354 and 0.6908 for the MPLS, PLS and PCR, respectively. The calibration was made with second derivative that spectrum designated was 8 nm in interval. The determination coefficients of head rice ratios were 0.7994, 0.8017 and 0.4473 for the MPLS, PLS and PCR, respectively. Those with 20 nm interval were 0.8004, 0.8493 and 0.6609 for the MPLS, PLS and PCR, respectively. These results indicate that the accuracy of determination coefficient for MPLS and PLS is higher than that of PCR.