• 제목/요약/키워드: calibrated initial values

검색결과 14건 처리시간 0.035초

An Improvement on Estimation for Causal Models of Categorical Variables of Abilities and Task Performance

  • Kim, Sung-Ho
    • Communications for Statistical Applications and Methods
    • /
    • 제7권1호
    • /
    • pp.65-86
    • /
    • 2000
  • The estimates from an EM when it is applied to a large causal model of 10 or more categorical variables are often subject to the initial values for the estimates. This phenomenon becomes more serious as the model structure becomes more serious as the model structure becomes more complicated involving more variables. In this regard Wu(1983) recommends among others that EMs are implemented several times with different sets of initial values to obtain more appropriate estimates. in this paper a new approach for initial values is proposed. The main idea is that we use initials that are calibrated to data. A simulation result strongly indicates that the calibrated initials give rise to the estimates that are far closer to the true values than the initials that are not calibrated.

  • PDF

특성이 다른 지게차 적재 중량 센서의 초기 값 오차 보정 (Error Calibration of Initial Value of Weight Measuring Sensors with Different Feature of Forklift)

  • 한치문;임춘식;이성렬
    • 한국항행학회논문지
    • /
    • 제23권2호
    • /
    • pp.214-220
    • /
    • 2019
  • 산업현장에서의 안전사고 빈도가 높은 지게차 전복의 주요 원인인 과적을 방지하기 위해 개발된 앵커(anchor) 볼트 형태의 strain 게이지 센서의 초기 값 오차를 보정하는 방법을 제안하였다. Strain 게이지 센서의 초기 값 오차는 앵커 볼트의 물리적이고 기계적 오차와 환경적 문제에기인하는 것을 확인하였다. 이러한 원인들을 제조 공정에서 제거하는 것은 본 연구의 범위를 벗어나는 것이기 때문에 제반 원인들을 고려한 보정 값을 찾고, 이 보정 값으로 strain 게이지 센서부를 구성하는 ADC 모듈의 초기 값을 보정하는 방법을 적용하였다. 보정 값 도출을 위하여 선형 보간법을 채택하였다. 도출한 보정 값을 4개의 strain 게이지 센서에 적용하여 시험한 결과 4개의 센서 모두 실제 중량 값과의 차이가 5% 이내가 되는 것을 확인하였다. 아울러 초기 값 보정 전에는 센서들의 ADC 값과 적재 중량 실제 값의 상관성이 없었던 점도 동시에 해결할 수 있었다.

Fluctuation of estimates in an EM procedure

  • Kim, Seong-Ho;Kim, Sung-Ho
    • 한국통계학회:학술대회논문집
    • /
    • 한국통계학회 2003년도 춘계 학술발표회 논문집
    • /
    • pp.157-162
    • /
    • 2003
  • Estimates from an EM algorithm are somewhat sensitive to the initial values for the estimates, and it is more likely when the model becomes larger and more complicated. In this article, we examined how the estimates fluctuate during an EM procedure for a recursive model of categorical variables. It is found that the fluctuation takes place mostly during the first half of the procedure and that it can be subdued by applying the Bayesian method of estimation. Both simulation data and real data are used for illustration.

  • PDF

Effects of Long-term Exposure of High and Low Humidity on Thin-film Humidity Sensors

  • Lee, Sang-Wook;Choi, Byung Il;Kim, Jong Chul;Woo, Sang-Bong
    • 센서학회지
    • /
    • 제27권6호
    • /
    • pp.368-373
    • /
    • 2018
  • The effects of long-term exposure of high and low humidity on thin-film humidity sensors are investigated. Five commercially available thin-film humidity sensors are initially calibrated in a humidity chamber as a reference before longterm exposure to high and low humidity. Then, the sensors are kept in a high-humidity environment (~95 %rh) for four months. After the exposure, the sensors are calibrated in the same manner as the initial calibration. Consequently, the device reading values from the humidity sensors are elevated up to about 5 %rh. Interestingly, the degree of elevation by the high-humidity exposure shows a negative correlation with the price of the humidity sensors. Humidity sensors are then kept in a low-humidity environment (~10 %rh) for another four months. After the exposure, a calibration similar to the initial calibration is performed. As a result, the device reading from humidity sensors is decreased, indicating a recovery from the effect of high-humidity exposure. The durability test conducted in this study provides experimental evidence for the use of thin-film humidity sensors in high-humidity environments such as greenhouses and food factories for a long period of time.

농촌유역에서의 초기강우손실 특성분석과 계수 산정식 개발 - 금강.삽교천 중소유역을 중심으로- (Characteristic Analysis of the Coefficient of Initial Abstraction and Development of its Formular in the Rural Watersheds - for the Small-Medium Watersheds in the Geum and Sapkyo River -)

  • 김태철;이정선
    • 한국농공학회논문집
    • /
    • 제50권6호
    • /
    • pp.3-12
    • /
    • 2008
  • It is important to estimate accurate effective rainfall to analyse flood flow and long-term runoff for the rational planning, design, and management of water resource. The initial abstraction is also important to estimate effective rainfall. The Soil Conservation Service (SCS) has developed a procedure and it has been most commonly applied to estimate effective rainfall. But the SCS method still has weak points, because of unnatural assumptions such as antecedent moisture conditions and initial abstraction. The coefficient of initial abstraction(K) is depending on the soil moisture condition and antecedent rainfall. The maximum storage capacity of Umax which is calibrated by stream flow data in the proposed watershed was derived from the DAWAST(DAily WAtershed STreamflow) model. The values of K obtained from 69 storm events at the five watersheds are ranging from 0.133 to 0.365 and its mean value is 0.207. Effective rainfall could be estimated more reasonably by introducing new concept of initial abstraction. The equation of $K=0.076Sa^{0.255}$ was recommended instead of 0.2 and it could be applicable to the small-medium rural watersheds.

에어챔버가 설치된 송수관로에서의 수격현상 (Waterhammer in the Transmission Pipeline with an Air Chamber)

  • 김경엽
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.177-183
    • /
    • 2002
  • The field tests on the waterhammer were carried out in the pump pipeline system with an air chamber. The effects of the input variables and the design parameters for the air chamber were investigated by both the numerical calculations and the experiments. Because the waterhammer problems as a result of the pump power failure were the most important, these situations were carefully studied. Among the input variables used in the waterhammer analysis, the polytropic exponent, the discharge coefficient and the wavespeed had influence on the simulated results in that order, and were calibrated in comparison with the experimental results. As the initial air volume in a vessel increased, the period of waterhammer increased and the pressure variation decreased, resulting from the reduction of the rate of pressure change in the air chamber. Using smaller orifice in the bypass pipe, the pressure rise was suppressed in some degree and the pressure surge was dissipated more rapidly as time passed. The simulations were in fairly good agreement with the measured values until 1∼2 periods of waterhammer. Not only the maximum and minimum pressures in the pipe1ine but also those occurring times were reasonably predicted. The computer program developed in this study will be useful in designing the optimum parameters of an air chamber for the real pump pipeline system.

Analysis of beam-column joints reinforced with SMAs under monotonous loading with existence of transverse beam

  • Halahla, Abdulsamee M.;Tahnat, Yazan B. Abu;Dwaikat, Monther B.
    • Earthquakes and Structures
    • /
    • 제22권3호
    • /
    • pp.231-243
    • /
    • 2022
  • Beam-column joints (BCJs) are recognized among the most crucial zones in reinforced concrete structures, as they are the critical elements subjected to a complex state of forces during a severe earthquake. Under such conditions, BCJs exhibit behaviors with impacts that extend to the whole structure and significantly influence its ductility and capability of dissipating energy. The focus of this paper is to investigate the effect of undamaged transverse beam (secondary beams) on the ductility of concrete BCJs reinforced with conventional steel and shape memory alloys bars using pushover analysis at tip of beam under different axial load levels at the column using a nonlinear finite element model in ABAQUS environment. A numerical model of a BCJ was constructed and the analysis outcomes were verified by comparing them to those obtained from previous experiments found in the literature. The comparison evidenced the capability of the calibrated model to predict the load capacity response of the joint. Results proved the ability of undamaged secondary beams to provide a noticeable improvement to the ductility of reinforced concrete joints, with a very negligible loss in load capacity. However, the effect of secondary beams can become less significant if the beams are damaged due to seismic effects. In addition, the axial load was found to significantly enhance the performance of BCJs, where the increase in axial load magnified the capacity of the joint. However, higher values of axial load resulted in greater initial stiffness of the BCJ.

유출모형을 이용한 곡교천 유역의 강우-유출 특성 분석 (Analysis of Rainfall-Runoff Characteristics in Gokgyochun Basin Using a Runoff Model)

  • 황병기;조용수;양승빈
    • 한국산학기술학회논문지
    • /
    • 제20권2호
    • /
    • pp.404-411
    • /
    • 2019
  • 곡교천 유역의 홍수-유출 특성을 파악하는 연구를 수행하기 위하여 HEC-HMS 모형을 적용하였다. 이 유역은 일부 소유역에서 대규모 농업용 저수지가 있어 소유역으로부터 발생한 초기 유출이 저수지에 의해서 상당량 저류되는 특징을 갖고 있다. 이러한 현상을 반영하기 위하여 3가지 침투모의 방법을 사용하였으며, 방법 1은 기존의 유출곡선지수법, 방법 2는 방법 1에 표면법 기능을 추가한 방법, 방법 3은 초기 및 일정손실율 방법이다. 모형은 3가지 방법으로 손실계산, Clark의 단위도법으로 강우의 직접유출 변환, 지수함수적 감소법으로 기저유량, Muskingum 법으로 하도추적 하는 과정을 포함한다. 모형에서 최적화 기법을 시행착오법과 병행하여 최적화 변수를 도출하였다. NSE, RAR, and PBIAS 등의 평가지표를 사용하여 모형의 보정을 수행하였다. 유출체적, 첨두유량, 첨두발생시각 등에 대하여 모의치와 실측치를 비교한 결과 초기손실을 반영할 수 있도록 설계된 방법2와 3에서 우수한 결과를 나타낸 반면, 그렇지 못한 방법 1은 모의치와 실측치의 차이가 큰 것으로 나타났다. 복합 강우인 경우에 방법 3은 방법 2에 비하여 좋은 결과를 나타내지 못하였다. 결론적으로 방법 2가 단일 강우나 복합강우 모두 좋은 결과를 주는 것으로 나타났다. 본 연구의 결과는 정책입안자가 홍수관리대책을 수립하는 데 유용한 도구로서 사용되어 질 수 있을 것으로 판단된다.

Ambient vibration based structural evaluation of reinforced concrete building model

  • Gunaydin, Murat;Adanur, Suleyman;Altunisik, Ahmet C.
    • Earthquakes and Structures
    • /
    • 제15권3호
    • /
    • pp.335-350
    • /
    • 2018
  • This paper presents numerical modelling, modal testing, finite element model updating, linear and nonlinear earthquake behavior of a reinforced concrete building model. A 1/2 geometrically scale, two-storey, reinforced concrete frame model with raft base were constructed, tested and analyzed. Modal testing on the model using ambient vibrations is performed to illustrate the dynamic characteristics experimentally. Finite element model of the structure is developed by ANSYS software and dynamic characteristics such as natural frequencies, mode shapes and damping ratios are calculated numerically. The enhanced frequency domain decomposition method and the stochastic subspace identification method are used for identifying dynamic characteristics experimentally and such values are used to update the finite element models. Different parameters of the model are calibrated using manual tuning process to minimize the differences between the numerically calculated and experimentally measured dynamic characteristics. The maximum difference between the measured and numerically calculated frequencies is reduced from 28.47% to 4.75% with the model updating. To determine the effects of the finite element model updating on the earthquake behavior, linear and nonlinear earthquake analyses are performed using 1992 Erzincan earthquake record, before and after model updating. After model updating, the maximum differences in the displacements and stresses were obtained as 29% and 25% for the linear earthquake analysis and 28% and 47% for the nonlinear earthquake analysis compared with that obtained from initial earthquake results before model updating. These differences state that finite element model updating provides a significant influence on linear and especially nonlinear earthquake behavior of buildings.

액상형 고령친화식품의 치아부식능 평가 (Assessment of the erosive potential of elder-friendly foods)

  • 정은하;강정윤;한선영
    • 한국치위생학회지
    • /
    • 제22권5호
    • /
    • pp.461-468
    • /
    • 2022
  • Objectives: To investigate the effect of several elder-friendly foods on oral health and suggest guidelines for proper food intake. Methods: Six elderly-friendly foods (liquid type) and two control groups (mineral water and mixed coffee) were selected for this study. The pH of the food was measured using a calibrated pH meter, and the titratable acidity was determined using 1 M NaOH until 7.0 (TA 7.0). The screening method suggested by the International Organization for Standards was performed using an undersaturated hydroxyapatite solution to determine the difference between the initial and final pH of the screening solution (△pH). In addition, the sugar content was measured and expressed as Brix (%). Results: All the elder-friendly foods tested in this study showed a neutral pH (6.68-7.35), similar to mineral water (pH 7.84). The range of TA 7.0 values was 0.00-0.54 ㎖. The changes in pH determined using the screening solution confirmed that the largest change in pH was found in Careon (△pH 1.14±0.02), which has no erosive potential. Nevertheless, all elder-friendly foods had higher sugar content than the negative control group. Conclusions: Low tooth erosive potential was found in elder-friendly foods, but these foods showed high sugar content.