• Title/Summary/Keyword: cadence

Search Result 438, Processing Time 0.03 seconds

A Study on Efficient Test Methodologies on Dual-port Embedded Memories (내장된 이중-포트 메모리의 효율적인 테스트 방법에 관한 연구)

  • Han, Jae-Cheon;Yang, Sun-Woong;Jin, Myoung-Gu;Chang, Hoon
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.8
    • /
    • pp.22-34
    • /
    • 1999
  • In this paper, an efficient test algorithm for embedded dual-port memories is presented. The proposed test algorithm can be used to test embedded dual-port memories faster than the conventional multi-port test algorithms and can be used to completely detect stuck-at faults, transition faults and coupling faults which are major target faults in embedded memories. Also, in this work, BIST which performs the proposed memory testing algorithm is designed using Verilog-HDL, and simulation and synthesis for BIST are performed using Cadence Verilog-XL and Synopsys Design-Analyzer. It has been shown that the proposed test algorithm has high efficiency through experiments on various size of embedded memories.

  • PDF

Immediate Effect of Fabric Ankle-Foot Orthosis on Spatiotemporal Gait Parameters in Children With Spastic Cerebral Palsy (패브릭 발목 보조기가 경직성 뇌성마비 아동의 시공간적 보행 변수에 미치는 즉각적인 효과)

  • Sim, Yon-Ju;Lee, Dong-Ryul;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.21 no.1
    • /
    • pp.29-36
    • /
    • 2014
  • The purpose of this study was to investigate the immediate effect of fabric ankle-foot orthosis on spatiotemporal gait parameters, compared to a barefoot condition in children with spastic cerebral palsy. Eleven children with spastic cerebral palsy participated in this study. Spatiotemporal gait parameters were measured with the GAITRite system. Fabric ankle-foot orthosis significantly improved Timed Up and Go test time and gait velocity. There was no significant difference in cadence. The step time significantly improved in both the more and less affected foot compared to the barefoot condition. The step length of the affected foot also significantly improved, but there was no significant difference in the step length of the less affected foot. There was significant improvement in the stride length of both the affected and less affected foot, but no significant difference in single stance or double stance. The fabric ankle-foot orthosis could improve stability, and selective control of the joint and promote better walking in children with cerebral palsy. Consequently, the fabric ankle-foot orthosis might be an alternative assistive device for neurological populations as a primary role instead of the typical ankle-foot orthosis.

The Design and fabrication of Capacitive Humidity Sensor Having Interdigital Electrodes and Its Signal Processing Circuit (빗살전극형 정전용량형 습도센서와 그 신호처리회로의 설계 제작)

  • Kang, Jeong-Ho;Lee, Jae-Yong;Kim, Woo-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.26-30
    • /
    • 2006
  • For the purpose of developing capacitive humidity sensor having interdigital electrodes, interdigital electrode was modeled and simulated to obtain capacitance and sensitivity as a function of geometric parameters like the structural gap and thickness. For the development of ASIC, switched capacitor signal processing circuits for capacitive humidity sensor were designed and simulated by Cadence using $0.25{\mu}m$ CMOS process parameters. The signal processing circuits are composed of amplifier for voltage gain control, and clock generator for sensor driving and switch control. The characteristics of the fabricated sensors are; 1) sensitivity is 9fF/%R.H., 2) temperature coefficient of offset(TCO) is $0.4%R.H./^{\circ}C$, 3) nonlinearity is 1.2%FS, 4) hysteresis is 1.5%FS in humidity range of $3%R.H.{\sim}98%R.H.$. The response time is 50 seconds in adsorption and 70 seconds in desorption. Fabricated process used in this capacitive humidity sensor having interdigital electrode are just as similar as conventional IC process technology. Therefore this can be easily mass produced with low cost, simple circuit and utilized in many applications for both industrial and environmental measurement and control system, such as monitoring system of environment, automobile, displayer, IC process room, and laboratory etc.

Detection of planetary signals in extremely weak central perturbation microlensing events via next-generation ground-based surveys

  • Chung, Sun-Ju;Lee, Chung-Uk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.72.1-72.1
    • /
    • 2013
  • Even though current microlensing follow-up observations focus on high-magnification events due to the high efficiency of planet detection, it is very difficult to do a confident detection of planets in high-magnification events with extremely weak central perturbations (i.e., the fractional deviation is ${\delta}{\leq}0.02$). For the confident detection of planets in the extremely weak central perturbation events, it is needed both the high cadence monitoring and the high photometric accuracy. A next-generation ground-based observation project, KMTNet (Korea Microlensing Telescope Network), satisfies both the conditions. Here we investigate how well planets in high-magnification events with extremely weak central perturbations are detected by KMTNet. First, we determine the probability of occurrence of events with ${\delta}{\leq}0.02$. From this, we find that for ${\leq}100M_E$ planets in the separation of $0.2AU{\leq}d{\leq}20AU$, events with ${\delta}{\leq}0.02$ occur with a frequency of more than 70%, in which d is the projected planet-star separation. Second, we estimate the efficiency of detecting planetary signals in the events with ${\delta}{\leq}0.02$ via KMTNet. We find that for main-sequence and subgiant source stars, ${\geq}1M_E$ planets can be detected more than 50% in a certain range that has the efficiency of ${\geq}10%$ and changes with the planet mass.

  • PDF

Gait Analysis of the Chronic Lumbosacral Radiculopathic Patients (만성 요천추부 신경근병증 환자의 보행분석)

  • Choi, Byung-Ok;You, Jae-Eung;Jung, Seok
    • Physical Therapy Korea
    • /
    • v.11 no.3
    • /
    • pp.19-24
    • /
    • 2004
  • The purposes of this study were to analyze gait patterns of patients with chronic lumboscaral radiculopathy and to investigate gait parameters which can reflect a functional deficit in relation to the level of lumbosacral radiculopathy. The study population consisted of 25 patients of chronic lumbosacral radiculopathy and 25 healthy control subjects. Conventional physical examinations and three-dimensional gait analyses were performed on all participants. The data were analyzed using an independent sample t-test. The results were as follows: (1) In the patients' group, cadence, walking velocity, stride length and double support time were less than in the control group (p<.05). (2) In the patients' group, maximum flexion of hip, maximum flexion of loading response, maximum flexion of swing phase on the knee and maximum plantar flexion of pre-swing were less than the control group (p<.05). Using three-dimensional gait analysis, we could identify specific gait parameters to reflect a functional deficit related to the level of lumbosacral radiculopathy.

  • PDF

Analysis of Gait Parameters According to the Clinical Features of Parkinson's Disease Using 3-D Motion Analysis System with Electrogoniometer (3차원 전기측각 보행분석기를 이용한 파킨슨씨병 환자의 임상 양상에 따른 보행 분석)

  • Baek, Hye-Jin;Yoon, Joon-Shik;Kim, Sei-Joo;Lee, Gyu-Ho;Koh, Seong-Beom
    • Annals of Clinical Neurophysiology
    • /
    • v.11 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Background: To investigate the differences of locomotor dynamics between Parkinson's disease (PD) patients with tremor dominant symptom and patients with postural instability dominant symptom. Methods: 66 subjects with PD were classified into two subgroups, tremor-dominant group and postural instability and gait disorder group by Unified Parkinson's disease rating scale (UPDRS). The spatial, temporal and electrodynamic gait parameters were recorded automatically using computerized 3-D motion analysis system with electrogoniometer. Results: There was no significant difference in cadence, pelvic tilt range, hip flexion range, knee flexion range and ankle dorsiflexion range. Postural instability and gait disorder group showed decreased gait velocity, short stride length, decreased range of motion in pelvic obliquity, pelvic rotation and ankle plantar flexion. Conclusions: There was meaningful difference in locomotor dynamics between Parkinson's disease(PD) patients with tremor dominant symptom and patients with postural instability dominant symptom.

  • PDF

Modeling of Gate/Body-Tied PMOSFET Photodetector with Built-in Transfer Gate (내장된 전송게이트를 가지는 Gate/Body-Tied PMOSFET 광 검출기의 모델링)

  • Lee, Minho;Jo, Sung-Hyun;Bae, Myunghan;Choi, Byoung-Soo;Choi, Pyung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.284-289
    • /
    • 2014
  • In this paper, modeling of a gate/body-tied (GBT) PMOSFET photodetector with built-in transfer gate is performed. It can control the photocurrent with a high-sensitivity. The GBT photodetector is a hybrid device consisted of a MOSFET, a lateral BJT, and a vertical BJT. This device allows for amplifying the photocurrent gain by $10^3$ due to the GBT structure. However, the operating parameters of this photodetector, including its photocurrent and transfer characteristics, were not known because modeling has not yet been performed. The sophisticated model of GBT photodetector using a process simulator is not compatible with circuit simulator. For this reason, we have performed SPICE modeling of the photodetector with reduced complexity using Cadence's Spectre program. The proposed modeling has been demonstrated by measuring fabricated chip by using 0.35 im 2-poly 4-metal standard CMOS technology.

Effects of Close Kinetic Chain Resistant Exercise of Lower Extremity on the Gait with Stroke (닫힌 사슬 하지 저항운동이 뇌졸중 환자의 보행에 미치는 영향)

  • Moon, Sang-Hun;Kim, Young-Min
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.4
    • /
    • pp.475-483
    • /
    • 2014
  • PURPOSE: The purpose of the study was to determine the effects of close kinetic chain resistant exercise of lower extremity on the gait with stroke patients. METHODS: The subjects were 50 patients who were diagnosed with cerebrovascular accident. They were randomly assigned either to a close kinetic chain resistant exercise of lower extremity group (study group)(n=25) or open kinetic chain resistant exercise of lower extremity exercise group (control group)(n=25). Gait abilities were measured by using Timed Up & Go (TUG) test, Functional Gait Assessment (FGA) and spatio-temporal gait variable that were velocity, cadence, stride length, double limb support by 3 axises wireless accelerometer and sway angle of center of mass by same instrument. RESULTS: Study group and control group before and after the intervention there were significantly difference in TUG, FGA, spatio-temporal gait variables and sway angle of center of mass (p<.05). There were significantly different between study group and control group for all variables at post-exercise. CONCLUSION: When all is said and done it is expected to be used as a method for the treatment and prevention in the process of rehabilitation of patients with stroke. In its final analysis when applying resistant exercise of lower extremity to stroke patients' gait, close kinetic chain is more effective than open kinetic chain.

Design of an Integrated High Voltage Pulse Generation circuit for Driving Piezoelectric Printer Heads (피에조일렉트릭 프린터 헤드 구동을 위한 집적화된 고전압 펄스 발생 회로의 설계)

  • Lee, Kyoung-Rok;Kim, Jong-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.80-86
    • /
    • 2011
  • This paper presents an integrated variable amplitude high voltage pulse generation circuit with low power and small size for driving industrial piezoelectric printer heads. To solve the problems of large size and power overhead of conventional pulse generators that usually assembled with multiple high-cost discrete ICs on a PCB board, we have designed a new integrated circuit (IC) chip. Since all the functions are integrated on to a single-chip it can achieve low cost and control the high-voltage output pulse with variable amplitudes as well. It can also digitally control the rising and falling times of an output high voltage pulse by using programmable RC time control of the output buffer. The proposed circuit has been designed and simulatedd in a 180[nm] Bipolar-CMOS-DMOS (BCD) technology using HSPICE and Cadence Virtuoso Tools. The proposed single-chip pulse generation circuit is suitable for use in industrial printer heads requiring a variable high voltage driving capability.

Current Sensing Circuit of MOSFET Switch for Boost Converter (부스터 변환기를 위한 MOSFET 스위치 전류 감지 회로)

  • Min, Jun-Sik;No, Bo-Mi;Kim, Eui-Jin;Lee, Chan-Soo;Kim, Yeong-Seuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.9
    • /
    • pp.667-670
    • /
    • 2010
  • In this paper, a high voltage current sensing circuit for boost converter is designed and verified by Cadence SPECTRE simulations. The current mirror pair, power and sensing metal-oxide semiconductor field effect transistors (MOSFETs) with size ratio of K, is used in our on-chip current sensing circuit. Very low drain voltages of the current mirror pair should be matched to give accurate current sensing, so a folded-cascode opamp with a PMOS input pair is used in our design. A high voltage high side lateral-diffused MOS transistor (LDMOST) switch is used between the current sensing circuit and power MOSFET to protect the current sensing circuit from the high output voltage. Simulation results using 0.35 ${\mu}m$ BCD process show that current sensing is accurate and the pulse frequency modulation (PFM) boost converter using the proposed current sensing circuit satisfies with the specifications.