• 제목/요약/키워드: cable network

검색결과 370건 처리시간 0.029초

A cable tension identification technology using percussion sound

  • Wang, Guowei;Lu, Wensheng;Yuan, Cheng;Kong, Qingzhao
    • Smart Structures and Systems
    • /
    • 제29권3호
    • /
    • pp.475-484
    • /
    • 2022
  • The loss of cable tension for civil infrastructure reduces structural bearing capacity and causes harmful deformation of structures. Currently, most of the structural health monitoring (SHM) approaches for cables rely on contact transducers. This paper proposes a cable tension identification technology using percussion sound, which provides a fast determination of steel cable tension without physical contact between cables and sensors. Notably, inspired by the concept of tensioning strings for piano tuning, this proposed technology predicts cable tension value by deep learning assisted classification of "percussion" sound from tapping a steel cable. To simulate the non-linear mapping of human ears to sound and to better quantify the minor changes in the high-frequency bands of the sound spectrum generated by percussions, Mel-frequency cepstral coefficients (MFCCs) were extracted as acoustic features to train the deep learning network. A convolutional neural network (CNN) with four convolutional layers and two global pooling layers was employed to identify the cable tension in a certain designed range. Moreover, theoretical and finite element methods (FEM) were conducted to prove the feasibility of the proposed technology. Finally, the identification performance of the proposed technology was experimentally investigated. Overall, results show that the proposed percussion-based technology has great potentials for estimating cable tension for in-situ structural safety assessment.

초고속 인터넷서비스를 위한 케이블 데이터 가입자 망관리 시스템 설계 및 구현 (Design and Implementation of Cable Data Subscriber Network Management System for High Speed Internet Service)

  • 윤병수;하은주
    • 인터넷정보학회논문지
    • /
    • 제5권3호
    • /
    • pp.87-98
    • /
    • 2004
  • 일반 가입자들에게 초고속 인터넷 서비스를 제공하기 위해서 구성되는 가입자 망은ADSL, VDSL, DOCSIS 등 다양한 종류의 접속방식과 그에 따른 이기종(이기종)의 장비들로 이루어져 있다. 이러한 가입자 망은 전국적으로 분산되어 있으며, 분산된 가입자 망은 효과적이며 집중화된 형태로 관리하기 위해서는 다양한 형태의 접속방식을 지원하는 이기종 장비 및 단말들의 상위 개념으로서 추상적이며 논리적인 객체 관리모델이 필요하다. 본 논문은 통합된 계층적 망관리를 가능하게 하는 인터넷 가입자 망에 대한 모델링 구조론 RM-ODP흘 이용하여 제시하였다. 그리고 가입자 망의 예로서 UML을 이용한 객체지향 방법론을 채택하여 DOCSIS의 HFC 가입자망에 대한 관리 시스템을 설계하고 구현하였다.

  • PDF

An Adaptive Fast Expansion, Loading Statistics with Dynamic Swapping Algorithm to Support Real Time Services over CATV Networks

  • Lo Chih-Chen, g;Lai Hung-Chang;Chen, Wen-Shyen E.
    • Journal of Communications and Networks
    • /
    • 제8권4호
    • /
    • pp.432-441
    • /
    • 2006
  • As the community antenna television (CATV) networks becomes ubiquitous, instead of constructing an entirely new broadband network infrastructure, it has emerged as one of the rapid and economic technologies to interconnecting heterogeneous network to provide broadband access to subscribers. How to support ubiquitous real-time multimedia applications, especially in a heavy traffic environment, becomes a critical issue in modern CATV networks. In this paper, we propose a time guaranteed and efficient upstream minislots allocation algorithm for supporting quality-of-service (QoS) traffic over data over cable service interface specification (DOCSIS) CATV networks to fulfill the needs of realtime interactive services, such as video telephony, video on demand (VOD), distance learning, and so on. The proposed adaptive fast expansion algorithm and the loading statistics with dynamic swapping algorithm have been shown to perform better than that of the multimedia cable network system (MCNS) DOCSIS.

Sheath Circulating Current Analysis of a Crossbonded Power Cable Systems

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.320-328
    • /
    • 2007
  • The sheath in underground power cables serves as a layer to prevent moisture ingress into the insulation layer and provide a path for earth return current. Nowadays, owing to the maturity of manufacturing technologies, there are normally no problems for the quality of the sheath itself. However, after the cable is laid in the cable tunnel and is operating as part of the transmission network, due to network construction and some unexpected factors, some problems may be caused to the sheath. One of them is the high sheath circulating current. In a power cable system, the uniform configuration of the cables between sections is sometimes difficult to achieve because of the geometrical limitation. This will cause the increase of sheath circulating current, which results in the increase of sheath loss and the decrease of permissible current. This paper will study the various characteristics and effects of sheath circulating current, and then will prove why the sheath current rises on the underground power cable system. A newly designed device known as the Power Cable Current Analyser, as well as ATP simulation and calculation equation are used for this analysis.

최적의 케이블 모뎀 PHY 성능 구현 및 케이블 망 측정 시스템 개발 (Developing the Measurement System with Establishing the PHY Performance of Best Proper Cable Modem)

  • 이경문;고재평;이장명
    • 제어로봇시스템학회논문지
    • /
    • 제14권2호
    • /
    • pp.205-211
    • /
    • 2008
  • This paper describes the method aimed at establishing the equipment measuring the parameter of Cable Network by Best proper Cable Modem and PDA through RS232 interface. In this paper, we propose our creative experimental configuration and develope the Cable Modem (DOCSIS 2.0) superior more performing than the referred Cable Modem (DOCSIS 1.0, 1.1) and the measuring equipment of HFC network compositing of Cable Modem and PDA through RS232 interface. This equipment analyzes Upstream (U/S) and Downstream (D/S) Signal quality and generates the signal of Upstream by CW signal. The paper also provides the experimental results to check the Best Proper Cable Modem and the displayed screen for parameters for SNR, BER and the demodulated IQ diagram of 256QAM through LCD of PDA. Henceforth, it'll be possible to support a variety of the functions for E-mail, Internet, the speed test of WEB connection and the transmission of the measured result real time by PDA.

유선 케이블 모뎀의 FEC 성능평가 (Error Performance Analysis of a FEC for the Cable Modem)

  • 이창재;김경덕;최형진
    • 한국통신학회논문지
    • /
    • 제26권11A호
    • /
    • pp.1803-1811
    • /
    • 2001
  • 본 논문에서는 미국의 유선 케이블 모뎀 규격인 MCNS(Multimedia Cable Network System) DOCSIS(Data Over Cable Service Interface Specification)를 만즉하는 하향 채널의 64/256-QAM 수신부 FEC(Forward Error Correction)를 분석하였다. FEC는 기본적으로 RS(Reed-Solomon) 계층과 TCM(Trellis Coded Modulation) 계층으로 구분되며, 여기에 추가적으로 interleaving과 randomizer 계층들이 결합되어 있다. AWGN(Additive White Gaussian Noise) 환경에서의 BER(Bit Error Rate) 성능평가를 통해 수신부 연판정 비터비 복호기(soft Viterbi decoder)의 추적 깊이(trace-back depth)와 양자화 레벨(quantization level)의 크기에 따라 부호화 이득이 변함을 확인하였다.

  • PDF

객체지향 모델링을 이용한 케이블 데이터 가입자 망관리 시스템의 설계 및 구현 (Design and Implementation of Cable Data Subscriber Network Management System using Object-oriented Modeling)

  • 윤병수;하은주;김채영
    • 정보처리학회논문지C
    • /
    • 제11C권2호
    • /
    • pp.269-276
    • /
    • 2004
  • 가입자 망에는 ADSL(Asymmetric Digital Subscriber Line), VDSL(Very high-bit rate Digital Subscriber Line), DOCSIS(Data Over Cable Service Interface Specifications) 등이 있으며, 다양한 형태가 있다. 다양한 종류의 접속방식과 이 기종의 장비를 이용하여 가입자에게 단일 형태의 초고속 인터넷 서비스를 제공하고 있다. 이러한 여러 가지 분산된 가입자 망을 효율적으로 관리하기 위해서는 다양한 형태의 접속방식을 지원하는 이 기종 장비 및 단말들의 상위 개념으로서 추상적이며 개념적인 객체 관리모델이 필요하다. 본 논문은 통합된 계층적 망 관리를 가능하게 하는 인터넷 가입자 망에 대한 모델링 구조를 RM-ODP를 이용하여 제시하였다. 그리고 가입자 망의 예로서 UML을 이용한 객체지향 방법론을 채택하여 DOCSIS의 HFC 가입자망에 대한 관리 시스템을 설계하고 구현하였다.

Cable damage identification of cable-stayed bridge using multi-layer perceptron and graph neural network

  • Pham, Van-Thanh;Jang, Yun;Park, Jong-Woong;Kim, Dong-Joo;Kim, Seung-Eock
    • Steel and Composite Structures
    • /
    • 제44권2호
    • /
    • pp.241-254
    • /
    • 2022
  • The cables in a cable-stayed bridge are critical load-carrying parts. The potential damage to cables should be identified early to prevent disasters. In this study, an efficient deep learning model is proposed for the damage identification of cables using both a multi-layer perceptron (MLP) and a graph neural network (GNN). Datasets are first generated using the practical advanced analysis program (PAAP), which is a robust program for modeling and analyzing bridge structures with low computational costs. The model based on the MLP and GNN can capture complex nonlinear correlations between the vibration characteristics in the input data and the cable system damage in the output data. Multiple hidden layers with an activation function are used in the MLP to expand the original input vector of the limited measurement data to obtain a complete output data vector that preserves sufficient information for constructing the graph in the GNN. Using the gated recurrent unit and set2set model, the GNN maps the formed graph feature to the output cable damage through several updating times and provides the damage results to both the classification and regression outputs. The model is fine-tuned with the original input data using Adam optimization for the final objective function. A case study of an actual cable-stayed bridge was considered to evaluate the model performance. The results demonstrate that the proposed model provides high accuracy (over 90%) in classification and satisfactory correlation coefficients (over 0.98) in regression and is a robust approach to obtain effective identification results with a limited quantity of input data.

실계통 적용을 위한 22.9kV, 50MVA, 초전도케이블 설치 및 운전 시험 (Installation and Operation Test of a 22.9kV, 50MVA, HTS Cable for Real Utility Grid Application)

  • 손송호;양형석;임지현;오승열;이수길;장현만;황시돌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.484-485
    • /
    • 2011
  • Since the year 2008, the first demonstration project of the superconducting cable for the KEPCO grid operation has been in progress. To apply the HTS (High Temperature Superconducting) cable system into the commercial network, a new test complex was built in the 154kV Icheon substation and the on site assembly of 22.9kV, 50MVA HTS cable with the cryogenic refrigeration system was finished. A full scale of HTS cable fabricated with 2nd generation wire is to be in service in KEPCO network. In this paper, a series of processes of the installation and operation test are introduced.

  • PDF

22.9kV 고온 초전도 케이블.초전도 한류기 스마트 그리드 적용을 위한 초전도 시범사업 (Introduction of The First Demonstration Project for the Application of HTS Cable and SFCL to Real Smart Grid in South Korea)

  • 양병모;박진우;이승렬
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권3호
    • /
    • pp.34-38
    • /
    • 2010
  • Until now some countries including South Korea have made big progress and many efforts in the development of high temperature superconductor (HTS) power equipments. Especially, HTS Cable and superconducting fault current limiter (SFCL) are the strongest candidates among them from the viewpoint of applying to real grid. In South Korea, HTS cable and SFCL have been installed in test fields and tested successfully at Gochang PT Center of KEPCO. In order to meet practical requirements and be feasible in real grid, a demonstration project for HTS cable and SFCL systems, called GENI(green superconducting electric power network at Icheon substation) project, has been initiated to install 23kV HTS cable and SFCL systems in a utility network in South Korea since 2008. Namely, it says the first demonstration project for the application HTS system to real smart grid in South Korea. This paper presents the design and the application plan of the 22.9kV HTS cable and SFCL in 154kV Icheon substation in South Korea with the viewpoint of applying in Smat Grid.