• Title/Summary/Keyword: cable insulator

Search Result 74, Processing Time 0.028 seconds

Influence of Partial Discharge Properties due to Void in Cable Joint Parts (케이블 접속재 부분방전 특성에 미치는 보이드의 영향)

  • 신종열;홍진웅
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.3
    • /
    • pp.69-74
    • /
    • 2003
  • To investigate the partial discharge and electric field distribution in cable joint parts, we measured the partial discharge and electric field in specimen. The specimens which cross-linked polyethylene(XLPE) and ethylene propylene diene ethylene(EPDM) are used to insulating material for underground cable md cable jointing parts. The polymers are used to insulating material in switchgear which is a kind of transformer equipment and in ultra-high voltage cable. Its using is increasing gradually, the electrical insulation properties are not only excellent but also mechanical property is excellent. And because it is possible to be made void of several type in insulator while it is produced, which the electrical field distribution is changed by void, it has a critical influence to insulator performance. The underground cable is connecting by the jointing material, insulating breakdown and the electric ageing which are caused by several mixing impurity and the damage of cable insulator layer, which reduced the life of cable while intermediate joint kit is connected. Therefore, the computer simulation is used to estimating insulator performance, XLPE is used to the insulating material of ultra-high voltage cable and EPDM is used to insulator layer in joint material kit, and which are produced as specimen. And it is analyzed the electric field concentrating distribution and partial discharge by modeling of computer simulation in void and cable joint kit.

Improvement of Tracking Property of Silicone Rubber Used for Out-door Polymer Insulator According to Aluminium Hydrate Filler (고분자애자용(高分子碍子用) 실리콘고무 재료(材料)의 $Al(OH)_3$에 의한 Tracking성(性) 향상(向上) 연구(硏究))

  • Hahn, K.M.;Kim, D.W.;Oh, M.W.;Kweon, H.S.;Kim, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1239-1241
    • /
    • 1993
  • This paper studies on the improvement of non-tracking property which is very important matter for developing polymer insulator. Non-Tracking property of silicon rubber used for polymer insulator was investigated by ASTM D 2303 according to Aluminium Hydrate filler. Furthermore other electrical and mechanical properties were estimated. The optimum amount of Aluminium Hydrate should be considered by following test results.

  • PDF

Partial Discharge Diagnosis of Thermal Degradated PVC Cable (열열화된 PVC 케이블의 부분방전 진단)

  • Song, Ki-Tae;Lee, Sung-Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.3
    • /
    • pp.208-214
    • /
    • 2011
  • In this thesis, the partial discharge according to applied voltage and variations of cross-sectional area and length of the conductor related to general condition for using cable was measured in order to study degradation diagnosis for 2-Core cable of the PVC insulator used in industrial fields for other safety installations. Also the thermal degradation conditions under various installation circumstances of cables were studied by assuming degradation conditions with each different degradation rate (50%, 67%, 100%) such as variation in degradated temperature, thermal exposure time, normal state, partially degradated state and overall degradated state for thermal degradation diagnosis. The quantity of electric discharge (V-Q) according to applied voltage was measured for measurement of inception voltage and extinction voltage. The quantity of electric discharge and the number of electric discharge (Q-N) were measured with applied voltage kept constantly. In addition, pictures were taken using SEM (scanning electron microscope) to compare the surface of external insulator to degradated state of internal insulator according to thermal degradation temperature and also compare the surface of external insulator to degradated surface state of internal insulator according exposure time of cables to thermal stress.

A Studies on Aging Properties for Transmission Line Polymer Insulators which are Installed in service (실계통에 포설된 송전용 고분자 애자의 AGING 특성 연구)

  • Kim, So-Yeon;Lee, Sang-Jin;Ha, Young-Kil;Kim, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.152-154
    • /
    • 2001
  • Recently the extensive use of composite insulators for transmission lines can ultimately be justified only on long-term qualification tests. Especially, it is possible for the Polymer insulator to be aged in according to the environment in which it is used this may bring about the decrease of the duration of voltage application. So, this paper deals with aging property of the polymer insulator installed at real transmission line in the industry area. The contact angle, arc test, tracking test were measured for acquiring the degradation characteristics of silicone rubber and the SEM, XRF, FT-IR tests were measured for analyzing the crack and components. Also the surface leakage current of the polymer insulator was compared with that of the porcelain insulator. Finally, we knew that the aging property was not appeared during seven months at real transmission line in the industry area.

  • PDF

Specific Heat and Thermal Conductivity of XLPE Insulator and Semiconductive Materials for 154kV Power Cable (154kV 전력케이블용 XLPE 절연체와 반도전 재료의 비열 및 열전도)

  • Lee, Kyoung-Yong;Yang, Jong-Seok;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.19-24
    • /
    • 2005
  • To improve mean-life and reliability of power cable, we have investigated specific heat (Cp) and thermal conductivity of XLPE insulator and semiconductive materials in 154kV underground power transmission cable. Specimens were respectively made of sheet form with EVA, EEA and EBA added 30wt%, carbon black, and the other was made of sheet form by cutting XLPE insulator in 154kV power cable. Specific heat (Cp) and thermal conductivity were· measured by DSC (Differential Scanning Calorimetry) and Nano Flash Diffusivity. Specific-heat measurement temperature ranges of XLPE insulator were from 20[$^{\circ}C$] to 90[$^{\circ}C$], and the heating rate was 1[$^{\circ}C$/min]. And the measurement temperatures of thermal conductivity were 25[$^{\circ}C$}], 55[$^{\circ}C$] and 90[$^{\circ}C$]. In case of semiconductive materials, the measurement temperature ranges of specific heat were from 20[$^{\circ}C$] to 60[$^{\circ}C$], and the heating rate was 1[$^{\circ}C$/min]. And the measurement temperatures of thermal conductivity were 25[$^{\circ}C$] and 55[$^{\circ}C$]. From these experimental results, both specific heat and thermal conductivity were increased by heating rate because volume of materials was expanded according to rise in temperature.

  • PDF

Thermal Conductivity Characteristic of Carbon Nanotube Composites and XLPE Insulator (탄소나노튜브 복합체와 XLPE 절연체의 열전도도 특성)

  • Yang, Jong-Seok;Kook, Jeong-Ho;Park, Noh-Joon;Nah, Chang-Woon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.160-161
    • /
    • 2006
  • To Improve the mean-life and the reliability of power cable, we have investigated thermal conductivity of XLPE insulator and semiconducting materials in l54[kV] underground power transmission cable. Specimens were made of sheet form with the nine of specimens for measurement. Thermal conductivity were measured by Nano Flash Diffusivity thermal conductivity measurement temperature ranges of XLPE insulator were from 20[$^{\circ}C$] to 90[$^{\circ}C$], and the heating rate was 1[$^{\circ}C$/mm]. In case of semiconducting materials. the measurement temperature ranges of thermal conductivity were from 20[$^{\circ}C$] to 60[$^{\circ}C$], and the heating rate was 1[$^{\circ}C$/min].

  • PDF

Evaluation of Effects of Impurities on Insulating Properties of Polymeric Insulator in Power Distribution Cable (배전케이블내 고분자 절연체의 절연성능에 미치는 불순물의 영향평가)

  • Cho, Young-Shin;Shim, Mi-Ja;Kim, Sang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1402-1404
    • /
    • 1997
  • To evaluate the effects of impurities on insulating properties of polymeric insulator in high electric power distribution cable, OIT and OMT were measured. By using Eyring plot, the thermodynamic parameters of ${\Delta}H$ and ${\Delta}S$ could be obtained.

  • PDF

Breakdown characteristics with temperature variation on XLPE 6.9kV cable insulator at power plants (발전소 6.9kV급 XLPE 케이블 절연재의 온도에 따른 절연파괴 특성분석)

  • Park, Noh-Joon;Yang, Sang-Hyun;Lee, Ki-Joung;Kong, Tae-Sik;Kim, Hee-Dong;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.79-79
    • /
    • 2010
  • In this paper, we present results of the dielectric breakdown test in various 6.9kV power cables used in power plants. The dielectric strength of the different conditioned cables was measured by placing the sliced cable sections in silicone oil bath with needle electrode. The results were analyzed by the Weibull distribution. The shape and scale parameters of the Weibull distribution for each cable sections under test were calculated and evaluated. Collected data base was applied to deterioration trend analysis and lifetime guide was also proposed.

  • PDF

Field Test Facilities for Composite Long Rod Insulator (고분자(高分子) 장간애자용(長幹碍子用) 옥외(屋外)시험장(試驗場) 구축(構築))

  • Hahn, Key-Man;Kim, Dong-Wook;Kwon, Hyuk-Sam;Yoo, Sung-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1499-1501
    • /
    • 1994
  • This paper studies on the outdoor field test facilities which are established for weather-resist and mechanical-resist property teat of composite insulator. We have established measuring and data acquisition system for various test conditions -leakage current, temperature, humidity, wind direction, wind velocity and rainfall. The merry-go-round test and salt fog test have been studied in order to evaluate non tracking property of rubber material. Especially we have checked the relationship between hydrophobicity and outdoor exposure degree by contact angle measurement.

  • PDF

Electrical Characteristics due to Inner Defect of Insulating Materials for Power Cable. (전력케이블 절연재료의 내부결함에 따른 전기적 특성)

  • Choi, Sang-Gi;Kim, Tag-Yong;Kim, Wang-Kon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.27-30
    • /
    • 2003
  • Recently, on power system, it is used to high voltage of transmission and distribution due to safe power supply and have high quality and insulation in order to satisfy excellent insulator. Thus, according to underground of high voltage cable, is occurred break down by ground short. Therefore, it is used to high quality XLPE power cable to interrupt instantaneous voltage drop. If it appear inner defect for cable whose have high quality and insulation, it is reduced rapidly due to concentration of electrical field. After assemble to manufacture, in order to inspect cable condition, it is decided much inspection standard. In this paper, In inner defect of assembling cable at manufacture, for measure the variation of insulation condition by void. it tested the variation of insulating characteristics, using $\phi$-q-n distribution variation in partial discharge experiment.

  • PDF