• Title/Summary/Keyword: c-distance

Search Result 2,418, Processing Time 0.028 seconds

The Distance from Skin to Cervical Epidural Space (피부에서 경부 경막외강까지의 깊이에 대한 연구)

  • Han, Kyung-Ream;Kwak, No-Kil;Whang, Hyuk-Ie;Kim, Ji-Young;Kim, Chan;Kim, Seoung-Mo
    • The Korean Journal of Pain
    • /
    • v.11 no.1
    • /
    • pp.105-108
    • /
    • 1998
  • Backgrounds: Cervical epidural nerve block is useful in the management of a variety of acute, chronic and cancer related pain syndromes involving the head, face, neck and upper extrimity. To safely perfom the cervical epidural block, an appreciation of the expected distance from skin to epidural space is important. We studied the distance from skin to cervical epidural space of adults to determine if any relationship exists between patient height, weight and neck circumference and the distance from skin to epidural space. Methods: Patients 170, suffering from neck and upper extremity pain with cervical HIVD(herniated intervertebral dics) were selected. Cervical epidural block was performed at $C_{6\sim7}$ or $C_{7-}T_1$ intervertebral space. Then measured the distance from skin to epidural space and analysed the relationship between age, height, weight and neck circumference and the distance from skin to epidural space. Results: The cervical epidural depth of male $C_{6\sim7}$, male $C_{7-}T_1$, female $C_{6\sim7}$ and female $C_{7-}T_1$ groups were $5.17{\pm}0.63$, $5.47{\pm}0.59$, $4.84{\pm}0.56$ and $5.01{\pm}0.60$ cm respectively. Cervical epidural depth significantly correlated with body weight, ponderal index and neck circumference. Conclusions: The distance from skin to cervical epidural space has significant relationships with weight, ponderal index and neck circumference. Although experience is important, patient's weight and neck circumference are indicating factor, of the cervical epidural depth.

  • PDF

Cluster-head-selection-algorithm in Wireless Sensor Networks by Considering the Distance (무선 센서네트워크에서 거리를 고려한 클러스터 헤드 선택 알고리즘)

  • Kim, Byung-Joon;Yoo, Sang-Shin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.4
    • /
    • pp.127-132
    • /
    • 2008
  • Wireless sensor network technologies applicable to various industrial fields are rapidly growing. Because it is difficult to change a battery for the once distributed wireless sensor network, energy efficient design is very critical. In order to achieve this purpose in network design, a number of studies have been examining the energy efficient routing protocol. The sensor network consumes energy in proportion to the distance of data transmission and the data to send. Cluster-based routing Protocols such as LEACH-C achieve energy efficiency through minimizing the distance of data transmission. In LEACH-C, however, the total distance between the nodes consisting the clusters are considered important in constructing clustering. This paper examines the cluster-head-selection-algorithm that reflect the distance between the base station and the cluster-head having a big influence on energy consumption. The Proposed method in this paper brought the result that the performance improved average $4{\sim}7%$ when LEACH-C and the base station are located beyond a certain distance. This result showed that the distance between cluster-head and the base station had a substantial influence on lifetime performance in the cluster-based routing protocol.

  • PDF

Real Time W-band FMCW Distance Measuring Devices Using TMS320C6701 DSP (TMS320C6701 DSP를 이용한 실시간 W-대역 FMCW 거리측정장치)

  • Lee, Chang-Won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.1 s.24
    • /
    • pp.109-116
    • /
    • 2006
  • This paper presents a real time distance measuring device using a W-band linear frequency modulated continuous wave(FMCW) radar and TMS320C6701 digital signal processor(DSP). We used FFT operation for measuring distance with the beat signals and the results of FFT could be converted to distance with ease. We presented how to implement a real time miniaturized hardware system including network protocols using a single DSP core. Also how to control the modulation signal of FMCW system to compensate the VCO nonlinearity using the Time Gating control of DSP is presented. We have shown that the proposed system has good performances for measuring distance in real time via outdoor environment experiments.

Measurement of the local heat transfer coefficient on a convex hemispherical surface with round oblique impinging jet (볼록한 표면위에 분사되는 원형경사충돌제트의 국소열전달계수 측정에 관한 연구)

  • 최형철;이세균;이상훈;임경빈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.846-854
    • /
    • 1999
  • Measurements of the local heat transfer coefficients were made on a hemispherically convex surface with a round oblique impinging jet. The liquid crystal transient method was used for these measurements. This method, which is a variation on the transient method, suddenly exposes a preheated wall to an impinging jet while video recording the response of liquid crystal for the surface temperature measurements. The Reynolds number used was 23000 and the nozzle-to-surface distance was L/d=2, 4, 6, 8, and 10 and the jet angle was $\alpha$=$0^{\circ}\; 15^{\circ}\;30^{\circ}C\; and \;40^{\circ}C$. In the experiment, the Nusselt number at the stagnation point decreases as the jet angle increases and has the maximum value for L/d=6. The X-axis Nusselt number distributions exhibit Secondary maxima at $0^{\circ}C\re $\alpha$\re 15^{\circ}C, L/d\le6$ for X/d<0(upstream) and at $0^{\circ}C\re $\alpha$40^{\circ}C,\;L/d\le4\;and\; at\; 30^{\circ}C\re $\alpha$$\leq$40^{\circ}C,\;L/d\le 6 $for X/d>0(downstream). The secondary maxima occurs at long distance from the stagnation point as the jet angle increases or the nozzle-to-surface distance decreases. The Y-axis Nusselt number distributions exhibit secondary maxima at Y/d=$\pm$2 for $0^{\circ}C\le a\le30^{\circ}C\; and\; L/d\le4, and \;for\;$\alpha$=40^{\circ}C$and L/d=2. The displacement of the maximum Nusselt number from the stagnation point increases as the jet angle increases or the nozzle-to-surface distance decreases and the maximum distance is about 0.67 times of the nozzle diameter. The ratio of the maximum Nusselt number to the stagnation Nusselt number increases as the jet angle increases.

  • PDF

An improved LEACH-C routing protocol considering the distance between the cluster head and the base station (클러스터 헤드와 기지국간의 거리를 고려한 향상된 LEACH-C 라우팅 프로토콜)

  • Kim, TaeHyeon;Park, Sea Young;Kwon, Oh Seok;Lee, Jong-Yong;Jung, Kye-Dong
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.373-377
    • /
    • 2022
  • Wireless sensor networks are being used in various fields. Wireless sensor networks are applied in many areas, such as security, military detection, environmental management, industrial control, and home automation. There is a problem about the limit of energy that the sensor network basically has. In this paper, we propose the LEACH-CCBD (Low Energy Adaptive Clustering hierarchy - Centrailized with Cluster and Basestation Distance) algorithm that uses energy efficiently by improving network transmission based on LEACH-C among the representative routing protocols. The LEACH-CCBD algorithm is a method of assigning a cluster head to a cluster head by comparing the sum of the distance from the member node to the cluster distance and the distance from the cluster node to the base station with respect to the membership of the member nodes in the cluster when configuring the cluster. The proposed LEACH-CCBD used Matlab simulation to confirm the performance results for each protocol. As a result of the experiment, as the lifetime of the network increased, it was shown to be superior to the LEACH and LEACH-C algorithms.

Preschool children medium-long distance stereoscopic vision testing

  • Weiqiang, Zhao;Xiaowang, Qiao;Singh, Sukh Mahendra
    • Advances in Traditional Medicine
    • /
    • v.4 no.2
    • /
    • pp.120-123
    • /
    • 2004
  • To test preschool children's medium- long distance stereoscopic vision normal average value, and intermittent strabismus children,s medium-long distance stereoscopic vision acuteness is the goal of this study. The software of random stereoscopic vision and graph, which is developed by Hu-Chong etc has been used, to test 414 cases normal preschool children and 19 cases intermittent exotropia childrens medium-long distance (1-5 m) stereoscopic vision (before operation and after operation). The normal average value of preschool children's medium-long distance stereoscopic vision was achieved. Intermittent exotropia children's stereoscopic vision acuteness was declined with the increase of distance. This method can provide reference as screening abnormal stereoscopic vision during scientific research and clinical work.

The kinematic analysis of the Hurdling of Men's 110m Hurdle (남자 국가대표 110m허들선수의 허들동작에 관한 운동학적 분석)

  • Lee, Jung-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.1
    • /
    • pp.83-98
    • /
    • 2004
  • The purpose of this study was to determine the kinematic variables of the hurdling for a korea record holder (A) and a national hurdle representative (B). after the kinematic variables such the distance and the distance and height of C.G, the velocity and the angle were analyzed about the hurdling. The results were summarized as follows; 1. In terms of the distance and the height of C.G, subject A showed long in horizontal distance from C.G to the take-off phase, but showed short in the landing phase. Subject B showed short in horizontal distance from C.G to the take-off phase, and showed long in the landing phase. 2. In terms of the velocity of C.G, Subject A showed fast C.G velocity in horizontal direction to the braking phase, Subject A and B showed slower C.G velority in the landing phase, but Subject A showed height C.G velocity in vertical direction to the to the take-off, the landing, and propulsion phase 3. In terms of the angle of C.G and lean of C.G to front at the braking and the take-off phase. Subject A kept the less angle in the maximum trunk lean to front at the flight phase as comparison with Subject B. 4. In terms of the velocity of the knee and the ankle joint. Subject A showed fast in the resultant velocity of the left ankle joint the take-off phase, but showed slow in the left knee joint. Subject B showed fast in the resultant velocity of the left knee joint the take-off phase, but showed slow in the right knee and the right ankle joint.

Graphic Method of Visual Analysis and Norms Determination for the Far Distance Phoria (원거리사위별 그래프 분석과 표준값 결정)

  • Joo, Seok-Hee;Park, Seong-Jong;Sim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.193-200
    • /
    • 2006
  • We investigated the visual analysis of the far distance phoria for 83 subjects who have emmetropia or myopia eyes, using the graphic method, and determined new norms. We got the following results from these experiments. 1. The measured norm of far distance phoria is $1.12{\Delta}$, exophoria, the that of near distance phoria is $0.50{\Delta}$, exophoria, the that of negative relative convergence at far distance(N.R.C.) is ${\times}$/11/5, the that of positive relative convergence at far distance(P.R.C.) is 10/20/8, the that negative relative convergence at near distance(N.R.C.) is 11/21/5, the that of positive relative convergence at near(P.R.C.) is 10/20/8, the that of negative relative accommodation(N.R.A.) is +2.54D, and the that of positive relative accommodation(P.R.A.) is -2.60D, respectively. We know from theses results that the measured norms of far distancet phoria is higher than Morgan's norms, while those of near distance phoria are lower than Morgan's norms. 2. We also know from these experiments that Morgan's norms are closely related to A, B, and C groups and Morgan's criterion can more usefully apply to the visual analysis. 3. In Sheard's criterion and Percival's criterion, the prism prescription is occurred when the exophoria of the far-point phoria is over $7{\sim}9{\Delta}$, and the esophoria of that is over $4{\sim}6{\Delta}$.

  • PDF

Diversity of Mitochondrial DNA Cytochrome b Gene in Roe Deer (Capreolus pygargus tianschanicus Satunin) from Jejudo Island, Korea (한국의 제주도에 서식하고 있는 노루(Capreolus pygargus tuanschanicus Satunin)의 미토콘드리아 DNA cytochrome b 유전자의 다양성)

  • Koh, Hung-Sun;Yang, Beong-Guk;Yoo, Hye-Sook;Chun, Tae-Young
    • Animal Systematics, Evolution and Diversity
    • /
    • v.16 no.2
    • /
    • pp.169-176
    • /
    • 2000
  • As one of researches to clarify the taxonomic status of roe deer from Jeju island (C. pygargus tianschanicus), we analyzed partial sequences of mtDNA cytochrome b gene from six roe deers at Jeju island in Korea. Maximum nucleotide Tamura & Nei's distance among three haplotypes was 0.005, and this distance was comparable to the diversity within other roe deer subspecies: it is suggested that roe deers from the mainland dispersed rarely to Jejudo Island, although further analyses are ne-cessary to decide whether or not it was occurred by human introduction. Furthermore, nucleotide distance between cytochrome b sequences of roe deers from Jeju (C. pygargus tianschanicus) and the sequence of roe deer from west Siberia(C. p. pygargus), obtained from GenBank, was average 0.013, and it is suggested that C. p. tianschanicus diverged from C. p. pygargus of west Siberia 0.65 Myr ago.

  • PDF

Study on Sensitivity and Resolution of Multihole Focusing Type Collimator (다공초점형(多孔焦点型) 콜리메타의 감도(感度)와 해상력(解像力)에 관(關)한 검토(檢討))

  • Park, Sung-Ock;Kyong, Kwang-Hyon;Park, Jun-Chul
    • Journal of radiological science and technology
    • /
    • v.5 no.1
    • /
    • pp.63-70
    • /
    • 1982
  • In order to estimate characteristics and functions of multi hole focusing type collimator, the authors measured the sensitivity and resolution varing with the distance between the face of collimator and source by experimental study. The results obtained with this study are as follows. 1. In comparison with focal distance obtained fram sensitivity measurement of various multi hole focusing type collimator, collimator A, C, E was 10 cm and collimator B, D was 12 cm in focal distance. 2. In regard of resolution of collimators having 10 cm focal distance, collimator A showed the finest resolutions than any other collimator(C, E). 3. By comparison regarding sensitivity by focal dist ante, the shorter the distance than a give focal distance of collimator, the worse the sensitivity of collimator. 4. With regard to resolution by focal distance, the shorter the distance than a given focal distance of collimator, the worse the resolution of collimator.

  • PDF