• Title/Summary/Keyword: bypass generation

Search Result 38, Processing Time 0.026 seconds

Reduction of Heat Generation from Junction Box in 3 kW Photovoltaic Power Generation System

  • Yun, Jung-Hyun;Sun, Ki-Ju;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.1
    • /
    • pp.21-24
    • /
    • 2016
  • A junction box used in a 3 kW photovoltaic power generation system plays a role in collecting and supplying the direct current voltage produced by photovoltaic modules to an inverter. It is also used for facilitating maintenance checks and protecting the module and inverter by keeping the voltage constant. As for the junction box, using it in a parallel connection creates a difference between the setup modules. In order to compensate, an inverse voltage diode is used. But the high-power created through the solar generator can be delivered to the inverter through the inverter regularly. Therefore, a component can break down due to excess heat. And consequently short circuits and electric leakage occurs. In this study, using a junction box that enabled the bypass of high electric power, it was possible to reduce heat generation by approximately 35℃ when compared to a standard junction box.

Depth-of-interest-based Bypass Coding-unit Algorithm for Inter-prediction in High-efficiency Video Coding

  • Rhee, Chae Eun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.4
    • /
    • pp.231-234
    • /
    • 2016
  • The next-generation video coding standard known as High-Efficiency Video Coding (HEVC) was developed with the aim of doubling the bitrate reduction offered by H.264/Advanced Video Coding (AVC) at the expense of an increase in computational complexity. Mode decision with motion estimation is still one of the most time-consuming computations in HEVC, as it is with H.264/AVC. Several schemes for a fast mode decision have been presented in reference software and in other studies. However, a possible speed-up in conventional schemes is sometimes insignificant for videos that have inhomogeneous spatial and temporal characteristics. This paper proposes a bypass algorithm to skip large-block-size predictions for videos where small block sizes are preferred over large ones. The proposed algorithm does not overlap with those in previous works, and thus, is easily used with other fast algorithms. Consequently, an independent speed-up is possible.

Effect of Gas Bypass at Turbine Inlet on Design of a Pressurized Solid Oxide Fuel Cell / Gas Turbine Hybrid System (가압형 고체산화물 연료전지 / 가스터빈 하이브리드 시스템 설계에서 터빈입구 바이패스의 효과)

  • Park, S.K.;Sohn, J.L.;Kim, T.S.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.1
    • /
    • pp.33-39
    • /
    • 2008
  • Hybrid power generation systems combining a solid oxide fuel cell and a gas turbine is promising due to their high efficiency. In the pressurized hybrid system, the operating condition of the gas turbine may play a critical role in designing the hybrid system. In particular, prevention of surge of the compressor can be a critical issue. The existence of fuel cell between the compressor and the turbine may cause an additional pressure loss and thus compressor operating points tend to approach the surge if the original turbine inlet temperature is pursued. In this study, bypassing some of the turbine inlet gas directly to the turbine exit side is simulated. Its effects on suppressing the surge problem and change in performance characteristics are discussed.

Cluster Head Chain Routing Protocol suitable for Wireless Sensor Networks in Nuclear Power Plants (원전 무선 센서 네트워크에 적합한 클러스터 헤드 체인 라우팅 프로토콜)

  • Jung, Sungmin
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.16 no.2
    • /
    • pp.61-68
    • /
    • 2020
  • Nuclear power plants have a lower cost of power generation, and they are more eco-friendly than other power generation plants. Also, we need to prepare nuclear plant accidents because of their severe damage. In the event of a safety accident, such as a radiation leak, by applying a wireless sensor network to a nuclear power plant, many sensor nodes can be used to monitor radiation and transmit information to an external base station to appropriately respond to the accident. However, applying a wireless sensor network to nuclear power plants requires routing protocols that consider the sensor network size and bypass obstacles such as plant buildings. In general, the hierarchical-based routing protocols are efficient in energy consumption. In this study, we look into the problems that may occur if hierarchical-based routing protocols are applied to nuclear power plants and propose improved routing protocols to solve these problems. Simulation results show that the proposed routing protocol is more effective in energy consumption than the existing LEACH protocol.

A Study on Real IP Traceback and Forensic Data Generation against Bypass Attack (우회적인 공격에 대한 실제 IP 역추적 실시와 포렌식 자료 생성)

  • Youn, Byung-Sun;Yang, Hae-Sool;Kim, Dong-Jhoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.1
    • /
    • pp.143-151
    • /
    • 2008
  • Execute IP traceback at this paper as target an intruder's attacking that Bypass Attack in order to avoid an exposure of own Real IP address Design IP traceback server and agent module, and install in Internet network system for Real IP traceback. Set up detection and chase range aggressive loop around connection arbitrariness, and attack in practice, and generate Real IP data cut off by fatal attacks after data and intrusion detection accessed general IP, and store to DB. Generate the Forensic data which Real IP confirms substance by Whois service, and ensured integrity and the reliability that buy to early legal proof data, and was devoted to of an invader Present the cyber criminal preventive effect that is dysfunction of Ubiquitous Information Society and an effective Real IP traceback system, and ensure a Forensic data generation basis regarding a judge's robe penalty through this paper study.

  • PDF

Isolation Control High Speed Transfer Switch for Upgrade Reliability of Uninterruptible Power Supply (USP의 신뢰성 향상을 위한 독립제어 고속절환장치)

  • Jung, Hyun-Chul;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.278-286
    • /
    • 2008
  • This paper investigates the fault generation type and the cause of output interruptionsin bulky with $30^{\sim}500[KVA]$ double conversion UPS, and proposes the fault detection method to improve the reliability of power supply used in the critical load in industry. Identifies its existing way of detecting a quality of inverter output it to bypass when exceeds its expectation. Under a UPS managing system, when an inner (Power device, Controller, CPU) fault occurs it disrupts the power supply and these occurrences has been verified by the results of experiments and application results. To overcome these problems, the proposed method constructs independently a fault-detection, a bypass-control device and a triple power supply apart from the conventional UPS operation. Also the detection point is changed to the preceding of a circuit breaker, a reference of fault detection is modified to avoid any clash and the breaking equipment is attached to intercept a spread of accident. As a result of applications of these developed systems to 242 UPS which was installed purposefully to the communication power supply, the service errors has not occurred in the UPS for two years since 2006.

Scaling Analysis of Thermal Hydraulics Phenomena in the Nuclear Reactor Vessel Downcomer during the Reflood Phase of LBLOCA (대형냉각재 상실사고 재관수 기간 동안, 차세대 원자로 강수부 내의 열수력 현상 모의를 위한 실험장치 척도해석)

  • Yun, B.J.;Song, C.H.;Kwon, T.S.;Euh, D.J.;Chu, I.C.;Yoon, Y.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.821-827
    • /
    • 2001
  • As one of the advanced design features of the Korea next generation reactor, direct vessel injection (DVI) system is being considered instead of conventional cold leg injection (CLl) system. It is known that the DVI system greatly enhances the reliability of the emergency core cooling (ECC) system. However, there is still a dispute on its performance in terms of water delivery to the reactor core during the reflood period of a large-break loss-of-coolant accident (LOCA). Thus, experimental validation is under progress. In this paper, a new scaling method, using time and velocity reduced linear scaling law, is suggested for the design of a scaled-down experimental facility to investigate the direct ECC bypass phenomena in PWR downcomer.

  • PDF

Thermal-hydraulic and load following performance analysis of a heat pipe cooled reactor

  • Guanghui Jiao;Genglei Xia;Jianjun Wang;Minjun Peng
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1698-1711
    • /
    • 2024
  • Heat pipe cooled reactors have gained attention as a potential solution for nuclear power generation in space and deep sea applications because of their simple design, scalability, safety and reliability. However, under complex operating conditions, a control strategy for variable load operation is necessary. This paper presents a two-dimensional transient characteristics analysis program for a heat pipe cooled reactor and proposes a variable load control strategy using the recuperator bypass (CSURB). The program was verified against previous studies, and steady-state and step-load operating conditions were calculated. For normal operating condition, the predicted temperature distribution with constant heat pipe temperature boundary conditions agrees well with the literature, with a maximum temperature difference of 0.4 K. With the implementation of the control strategy using the recuperator bypass (CSURB) proposed in this paper, it becomes feasible to achieve variable load operation and return the system to a steady state solely through the self-regulation of the reactor, without the need to operate the control drum. The average temperature difference of the fuel does not exceed 1 % at the four power levels of 70 %,80 %, 90 % and 100 % Full power. The output power of the turbine can match the load change process, and the temperature difference between the inlet and outlet of the turbine increases as the power decreases.

Effect of Aprotinin on Changes in Plasma Thromboxane $B_2$ and Endothelin-1 Concentratin after Extracorporeal Circulation (체외순환후 혈중 Thromboxane $B_2$와 Endothelin-1 농도 변화에 미치는 Aprotinin의 효과)

  • Lim, Cheong;Yun, Tae-jin;Kim, Yeon-seung;Kim, Seung-hoo;Lee, Jae-dam;Rho, Joon-Ryang;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.33 no.3
    • /
    • pp.221-229
    • /
    • 2000
  • Background: Thromboxane A2 and endothelin-1 are the potent vasoconstrictors affecting pulmonary pathophysiology in response to whole body inflammatin following CPB. Aprotinin, as an antiiflammatory agent, may decrease the release of such vasoactive substance from pulmonary tissues, preventing pulmonary hypertension after cardiopulmonary bypass. Material and Method: Ten mongrel dogs(Bwt. ac. 20kg) were subjected to cardioupulmonary bypass for 2 hours and postbypass pulmonary vascular resistance(0, 1, 2, 3 hours) were compared with prebypass level. The dogs were divided into 2 groups; control group(n-5) and aprotinin group(n=5). In the aprotinin group, aprotinin was administered as follows; 50,000 KIU/kg mixed in pump priming solution, 50,000 KIU/kg prebypass intravenous infusion over 30 minutes, 10,000 KIU/kg/hour postbypass continuous infusion. Prebypass and postbypass 0, 1, 2, 3 hour pulmonary vascular resistance were measured. At prebypass and postbypass 0, 90, 180 minutes, blood samples were obtained from pulmonary arterial and left atrial catherers for the assay of plasma thromboxane B2 a stable metabolite of thromboxane A2, and endothelin-1 concentrations. Result: The ratios of pustbypass over prebypass pulmonary vascular at postbypass 0, 1, 2, 3 hours were 1.28$\pm$0.20, 1.82$\pm$0.23, 1.90$\pm$0.19, 2.14$\pm$0.18 in control group, 1.58$\pm$0.18, 1.73$\pm$0.01, 1.66$\pm$0.10, 1.50$\pm$0.08 in aprotinin group ; the ratios gradually increased in control group while decreased or fluctuated after postbypass 1 hour in aprotinin group. There was statistically significant difference between control group and aprotinin group at postbypass 3 hours(P=0.014). Pulmonary arterial plasma concentration of thromboxane B2(pg/ml) at prebypass, postbypass 0, 90, 180 minutes were 346.4$\pm$61.9, 529.3$\pm$197.6, 578.3$\pm$255.8, 493.3$\pm$171.3 in control group, 323.8$\pm$118.0, 422.6$\pm$75.6, 412.3$\pm$59.9, 394.5$\pm$154.0 in aprotinin group. Left atrial concentrations were 339.3$\pm$89.2, 667.0$\pm$65.7, 731.2$\pm$192.7, 607.5$\pm$165.9 in control group, 330.0$\pm$111.2, 468.4$\pm$190.3, 425.4$\pm$193.6, 4.7.3$\pm$142.8 in aprotinin group. These results showed decrement of pulmonary thromboxane A2 generation in aprotinin group. Pulmonary arterial concentrations of endothelin-1(fmol/ml) at the same time sequence were 7.84$\pm$0.31, 13.2$\pm$0.51, 15.0$\pm$1.22, 16.3$\pm$1.73 in control group, 7.76$\pm$0.12, 15.3$\pm$0.71, 22.6$\pm$6.62, 14.9$\pm$1.11 in aprotinin group. Left atrial concentrations were 7.61$\pm$17.2, 57.1$\pm$28.4, 18.9$\pm$18.2, 31.5$\pm$20.5 in control group, 5.61$\pm$7.61, 37.0$\pm$26.2, 28.6$\pm$21.7, 37.8$\pm$30.6 in aprotinin group. These results showed that aprotinin had no effect on plasma endothelin-1 concentration after cardiopulmonary bypass. Conclusion: Administration of aprotinin during cardiopulmonary bypass could attenuate the increase in pulmonary vascular resistance after bypass. Inhibition of pulmonary thromboxane A2 generation was thought to be one of the mechanism of this effect. Aprotinin had no effect on postbypass endothelin-1 concentration.

  • PDF

Aprotinin Inhibits Vascular Smooth Muscle Cell Inflammation and Proliferation via Induction of HO-1

  • Lee, Dong-Hyup;Choi, Hyoung-Chul;Lee, Kwang-Youn;Kang, Young-Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.13 no.2
    • /
    • pp.123-129
    • /
    • 2009
  • Aprotinin is used clinically in cardiopulmonary bypass surgery to reduce transfusion requirements and the inflammatory response. The mechanism of action for the anti-inflammatory effects of aprotinin is still unclear. We examined our hypothesis whether inhibitory effects of aprotinin on cytokine-induced inducible nitric oxide synthase (iNOS) expression (IL-$l\beta$ plus TNF-$\alpha$), reactive oxygen species (ROS) generation, and vascular smooth muscle cell (VSMC) proliferation were due to HO-l induction in rat VSMCs. Aprotinin induced HO-l protein expression in a dose-dependent manner, which was potentiated during inflammatory condition. Aprotinin reduced cytokine mixture (CM)-induced iNOS expression in a dose dependent manner. Furthermore, aprotinin reduced CM-induced ROS generation, cell proliferation, and phosphorylation of JNK but not of P38 and ERK1/2 kinases. Aprotinin effects were reversed by pre-treatment with the HO-l inhibitor, tin protoporphyrin IX (SnPPIX). HO-l is therefore closely involved in inflammatory-stimulated VSMC proliferation through the regulation of ROS generation and JNK phosphorylation. Our results suggest a new molecular basis for aprotinin anti-inflammatory properties.