• 제목/요약/키워드: bypass flow

검색결과 326건 처리시간 0.024초

A Study on Darrieus-type Hydroturbine toward Utilization of Extra-Low Head Natural Flow Streams

  • Tanaka, Kei;Hirowatari, Kotaro;Shimokawa, Kai;Watanabe, Satoshi;Matsushita, Daisuke;Furukawa, Akinori
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권3호
    • /
    • pp.152-159
    • /
    • 2013
  • A two-dimensional Darrieus-type hydroturbine system, installed with a wear for flow streams such as small rivers and waterways, has been developed for hydropower utilization of extra-low head less than 2m. There are several problems such as flow rate change and flowing wastes to be solved for its practical use in natural flow streams. In the present study, at first, a design guideline in the case of overflow or bypass flow is shown by using simple flow model. Next, in order to avoid the unexpected obstacles flowing into the hydroturbine, an installation of waste screening system is examined. It is confirmed that the screen is effective with some amount of bypass flow rate, however the output power is remarkably deteriorated.

단일유로 멀티사이클 및 바이패스유로 멀티사이클 적용 냉동시스템의 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of a Single-Circuit Multi Cycle and a Bypass Two-Circuit Multi Cycle)

  • 송영승;정해원;윤원재;김용찬
    • 설비공학논문집
    • /
    • 제23권7호
    • /
    • pp.513-519
    • /
    • 2011
  • The object of this study is to investigate the performance characteristics of refrigerators using a single-circuit multi cycle and a bypass two-circuit multi cycle. Each refrigeration cycle was tested by varying secondary fluid mass flow rate and temperature. Based on the experimental data, the optimum refrigerant charge was 48 g and the COP at the optimum secondary fluid mass flow rate was 1.53 for the single-circuit multi cycle. For freezer(F)-only mode, both the single-circuit multi cycle and the bypass two-circuit multi cycle were operated at overcharge conditions, resulting in an increase of the secondary fluid mass flow rate. The maximum COPs of the single-circuit multi cycle and the bypass two-circuit multi cycle were 1.22 and 1.35, respectively. The COP increased by 10.7% with the application of the bypass two-circuit multi cycle.

Bypass 일체형 선박용 탈질설비의 입구형태에 대한 연구 (Study on the Inlet Shape of a Selective Catalyst Reduction System with an Integrated Bypass Unit for Ships)

  • 하수현;이재철;이상범;강동훈
    • 해양환경안전학회지
    • /
    • 제27권5호
    • /
    • pp.666-674
    • /
    • 2021
  • Bypass line과 Catalyst를 공간적으로 결합한 Bypass 일체형 탈질설비를 제안하였다. 탈질설비 내부에 설치되는 Bypass의 개폐장치의 형태에 따른 Catalyst로의 유동 변화를 확인하기 위하여 상용프로그램인 Ansys Fluent를 사용하여 탈질설비를 모델링하고 시뮬레이션을 구성하였다. 탈질설비 내의 Catalyst로 인한 계산시간과 Mesh의 수를 줄이기 위해 Porous media방식으로 Catalyst를 모델링하였다. Catalyst로의 입구각도와 Bypass 개폐장치의 크기를 변화시키면서 시뮬레이션을 수행하고 시뮬레이션의 결과로 Catalyst로의 유동 평균속도와 균일도의 변화를 확인하였다.

관상동맥 우회로술에서 내유동맥 이식편의 처치방법에 따른 문합전 내유동맥 혈류량의 비교 (Preparation of the Internal Mammary Artery Graft in Coronary Artery Bypass Surgery - Comparison of Free Mammary Artery Flows -)

  • 최종범;김형곤;정진원
    • Journal of Chest Surgery
    • /
    • 제26권2호
    • /
    • pp.148-153
    • /
    • 1993
  • To compare two methods of mammary pedicle graft preparations with free internal mammary artery flow, we studied 31 patients who had the left internal mammary artery harvested for coronary artery bypass grafting. The free flow was measured at the transected opening of 2 to 3 cm distal to the point of bifurcation on mean arterial pressure of 50 to 55 mmHg during cardiopulmonary bypass. Group I comprised 14 patients, whose grafts were sprayed and wrapped in sponges soaked in diluted papaverine solution (60 mg in 40 ml Hartmann's solution). An average 80 minutes after the preparations, free flow of the internal mammary artery ranged from 20 to 80 ml/min (mean 37.7 ml/min). Group II comprised 17 patients, who had internal mammary artery takedown under the exact conditions used in group I. The grafts were sprayed and wrapped in sponges soaked in the diluted papaverine solution as in group I. After an average of 28 minutes, free flow ranged from 8 to 28 ml/min (mean 17.6 ml/min). Intraluminal papaverine of the same dilution was then injected without any hydrostatic dilatation and flows increased upto 37 to 150 ml/min (mean 74.7 ml/min). This study shows that intraluminal papaverine preparation method markedly increases free mammary artery flow which is inadequate with external papaverine preparation.

  • PDF

발전소용 고압 바이패스 밸브 내부 유동해석 (Analysis of Flow through High Pressure Bypass Valve in Power Plant)

  • 조안태;김광용
    • 한국유체기계학회 논문집
    • /
    • 제10권6호
    • /
    • pp.17-23
    • /
    • 2007
  • In the present work, flow analysis has been performed in the steam turbine bypass control valve (single-path type) for two different cases i.e., case with steam only and case with both steam and water. The numerical analysis is performed by solving three-dimensional Reynolds-averaged Navier-Stokes (RANS) equations. The shear stress transport (SST) model and $k-{\varepsilon}$ model are used to each different case as turbulence closure. Symmetry condition is applied at the mid plane of the valve while adiabatic condition is used at the outer wall of the cage. Grid independency test is performed to find the optimal number of grid points. The pressure and temperature distributions on the outer wall of the cage are analyzed. The mass flow rate at maximum plug opening condition is compared with the designed mass flow rate. The numerical analysis of multiphase mixing flow(liquid and vapor) is also performed to inspect liquid-vapor volume fraction of bypass valve. The result of volume fraction is useful to estimate both the safety and confidence of valve design.

A Study on Thimble Plug Removal for PWR Plants

  • Song, Dong-Soo;Lee, Chang-Sup;Lee, Jae-Yong;Jun, Hwang-Yong
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.611-616
    • /
    • 1997
  • The thermal-hydraulic effects of removing the RCC guide thimble plugs are evaluated for 8 Westinghouse type PWR plants in Korea as a part of feasibility study: core outlet loss coefficient, thimble bypass flow, and best estimate flow. It is resulted that the best estimate thimble bypass flow increases about by 2% and the best estimate flow increases approximately by 1.2%. The resulting DNBR penalties can be covered with the current DNBR margin. Accident analyses are also investigated that the dropped rod transient is shown to be limiting and relatively sensitive to bypass flow variation.

  • PDF

The Thermal-Hydraulic Effects of Thimble Plug Removal for Westinghouse type PWR Plants

  • B. S. Jun;Park, E. J.;Kim, K. H.;Park, B. S.;K. L. Jeon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.166-172
    • /
    • 1996
  • The thermal-hydraulic effects of removing the RCC guide thimble plugs are evaluated for Westinghouse type PWR plants as a part of feasibility study: core outlet loss coefficient, thimble bypass flow, and best estimate flow. It is resulted that the best estimate thimble bypass flow increases about by 2% and the best estimate flow increase approximately by 1.2%. The resulting DNBR penalties can be covered within the current DNBR margin. Accident analyses are also investigated and the dropped rod transient is shown to be limiting and relatively sensitive to bypass flow variation.

  • PDF

바이패스비에 따른 배기가스의 적외선 신호측정 실험연구 (An Experimental Study of the Infrared Signal for Exhaust Plume with Bypass Ratio)

  • 주미리;조성필;최성만;조하나
    • 한국추진공학회지
    • /
    • 제23권5호
    • /
    • pp.1-9
    • /
    • 2019
  • 마이크로 터보제트 엔진을 사용하여 바이패스비에 따른 배기가스의 적외선 신호와 온도분포 측정 연구를 수행하였다. 본 연구에서는 마이크로 터보제트 엔진을 바이패스 공기를 공급하여 터보팬 엔진의 유동을 모사할 수 있도록 개조하였다. 마이크로 터보제트 엔진으로 코어 유동을 모사하고 고압의 압축 공기를 마이크로 터보제트 엔진의 외부덕트에 공급하여 바이패스 유동을 모사하였다. 바이패스비 0.5, 1.0, 1.4 의 3가지 조건에서 실험을 수행하였다. 그 결과 적외선 신호는 바이패스비가 증가할수록 점차 감소함을 보여주었다. 그리고 배기가스 온도는 바이패스비가 증가할수록 감소됨을 알 수 있었다. 또한 배기가스에 대한 쉴리렌 가시화 측정을 수행하였다. 배기가스의 온도분포와 쉴리렌 유동 가시화로부터 바이패스비에 따른 배기가스의 제트유동구조를 이해할 수 있다.

직접분사식 소형 디젤엔진의 실린더내 스월 유동장에 미치는 흡기포트의 형상에 관한 연구 (A Study on the Effects of Intake Port Geometry on In-Cylinder Swirl Flow Field in a Small D.I. Diesel Engine)

  • 이기형;한용택;정해영;임영철
    • 한국자동차공학회논문집
    • /
    • 제12권6호
    • /
    • pp.38-45
    • /
    • 2004
  • This paper studies the effects of intake port configuration on the swirl that is key parameter in the flow field of direct injection diesel engines. In-cylinder flow characteristics is known to have significant effects on fuel air mixing, combustion and emissions. To investigate the swirl flow generated by various intake ports, steady state flow tests were conducted to evaluate the swirl. Helical port geometry, SCV shape and bypass were selected as the design parameters to increase the swirl flow and parametric study was performed to choose the optimal port shape that would generate a high swirl ratio efficiently. The results revealed that a key factor in generating a high swirl ratio was to suitably control the direction of the intake air flow passing through the valve seat. For these purposes, we changed the distance of helical and tangential port as well as installed bypass near the valve seat and the effects of intake port geometry on in-cylinder flow field were visualized by a laser sheet visualization method. From the experimental results, we found that the swirl ratio and mass flow rate had a trade off relation. In addition, the result indicates that the bypass is a effective method to increase the swirl ratio without sacrificing mass flow rate.

내경 확장을 시행하지 않은 내유동맥을 이용한 관상동맥 우회로술의 임상적 결과[내유동맥 혈류량과 그임상적 결과] (Internal Mammary Artery Grafting Without Intraluminal Dilatation - Measurement of Internal Mammary Artery Flow and Clinical Results -)

  • 최종범
    • Journal of Chest Surgery
    • /
    • 제25권3호
    • /
    • pp.307-314
    • /
    • 1992
  • The internal mammary artery has been advocated for use in bypass grafting owing to its superior long-term patency when compared to saphenous vein grafts. Concern exists that the flow through internal mammary artery may be inadequate during periods of peak myocardial demand when the internal mammary artery graft was used for proximal left anterior descending artery stenosis. This flow adequacy was investigated in 13 consecutive patients with a mean proximal left anterior descending artery stenosis of 84.2% who were selected for coronary bypass using internal mammary artery. We checked flow and diameter of left internal mammary artery without intraluminal dilatation just before anastomosis to left anterior descending artery during cardiopulmonary bypass. Clinical results were evaluated postoperatively with clinical symptoms, echocardiographies, stress tests, and coronary angiographies. The mean internal mammary artery flow measured just before anastomosis was 38ml/ min[range of 20 to 80ml /min] and its mean internal diameter 1.4mm. Maximal workload was improved from preoperative value of 6.3$\pm$2.5METS to postoperative value of 9.1$\pm$1.4 METS in 9 patients who Paired-test can be used. Cardiac symptoms recurred in two patients after bypass surgery, but they were not related to left internal mammary artery grafts. All patients were discharged in postoperatively 9.3 days[range of 7 to 20 days] after operation without mortality. Thus, on the basis of these findings, the internal mammary artery is a reasonable graft that we can routinely use for proximal left descending artery stenosis if internal diameter of the internal mammary artery is more than 1.0mm and its flow is more than 20ml /min at mean arterial pressure of 50 to 60mmHg during cardiopulmonary bypass.

  • PDF