• Title/Summary/Keyword: bush-type electrical tree

Search Result 16, Processing Time 0.022 seconds

A Study on the Correlation Between the PD Pattern and the Type of Electrical Trees Propagation in the XLPE Insulation for the Underground Power Transmission

  • Lee, Jeon-Seon;Kim, Jeong-Tae;Koo, Ja-Yoon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.2
    • /
    • pp.12-17
    • /
    • 2001
  • In this work, the correlation between the PD Patterns and the electrical tree propagation has been investigated by use of the specimen removed from the insulation of the real 154 kV XLPE underground power cables. As a result, it could be deduced that the PD pattern regarding electrical trees depends on their type which could be classified into three different distinct groups such as branch-bush mixed. Considering the results of our investigation, if the partial discharge magnitude is only considered for the diagnosis of the cable system, it is possible to draw a wrong decision. Therefore, it is possible to propose that the time characteristics of PD pattern should be taken into account for the diagnosis of the cable system in addition to the conventional $\Phi$-q-n characteristics.

Electrical Pulses of Internal Partial Discharges Accompanying with Electrical Tree in LDPE (LDPE에서 발생된 전기트리에 수반된 내부 부분방전 펄스 해석)

  • Kang, S.H.;Park, Y.G.;Kwon, S.S.;Shin, T.S.;Lim, K.J.
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.216-221
    • /
    • 1999
  • The correlation between propagation of electrical tree and internal partial discharges is discussed. We use specimens with needle-plane electrode system made of LDPE(Low Density Polyethylene), observed inception and propagation of electrical tree by optical microscope and investigated the characteristics of the partial discharge (PD) pulses accompanying with propagation of electrical tree. In the specimens with needle-shaped void, the tree propagates branch type. The length of the tree has good linear relation with average discharge power of PD pulses. In the specimens without needle-shaped void, the tree grows bush type tree. The correlation between the area of the tree and the average discharge power of PD pulses has linear relation.

  • PDF

A Study on the AC Treeing Characteristics with Tip Radius of Needle Electrode in LLDPE/EVA (침전극 곡률반경에 따른 LLDPE/EVA의 교류트리 특성)

  • Lee, Jae-Pil;Lee, Chung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.476-480
    • /
    • 2003
  • Polyethylene used as insulating material of power cable is nonpolar and low dielectric loss polymer. But it has defects of tree generation and accumulation of space charge by an applied voltage resulting in the decreased life and performance. To solve these problems, mixed films with LLDPE and EVA that is similar to LLDPE at physical properties in case of low VA contents were made and tested due to the blend ratios of 80:20, 70:30, 60:40 and 50:50[wt%] respectively. We investigated AC electrical treeing characteristics to acquire the best mixture ratio and effect of the tip radius of needle electrode to develop excellent treeproof materials. The degree of crystallity calculated with XRD pattern is higher for pure LLDPE, 50:50 and 70:30. For DSC analysis, it is confirmed that the melting points of mixed specimens are lower than that of pure LLDPE and higher than pure EVA's. The shape of tree propagation showed that pure EVA was electrical tree shape of the branch type, pure LLDPE and blended specimens was able to confirm tree shape of the bush type. As the tip radius go up in the blend ratio 70:30 specimen, the tree inception voltage rise. Probably the reason is the relaxation of electric field in the specimen with bigger tip ratio. As the 6 specimens were applied AC 5[KV],7.5[KV],10[KV] respectively, tree growth length is far shorter in the specimen with blend ratio 70:30, 50:50 than in pure EVA and pure LLDPE specimen. Conclusively, it is confirmed that specimens of which blend ratio are 70:30 and 50:50 are good in electrical tree retardant characteristics, especially, 70:30 has lower dielectric loss than 50:50 and its mixture ratio is the best.

  • PDF

Measurement of Tree Growth Characteristics and Acoustics Emission Signals by Partial Discharge in XLPE (XLPE의 부분방전에 의한 트리진전 특성과 음향방출신호 측정)

  • Kim, Seung-Gyu;Lee, Sang-Woo;Lee, Kwang-Sik;Kim, Yeong-Hun;Kim, Geum-Yong;Kim, In-Sik;Kim, Lee-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1954-1956
    • /
    • 2000
  • In this paper, when void of XLPE was existed, electrical tree was growth in branch-type, and it was growth in bush-type when void of XLPE was not existed. Moreover, charge magnitude of partial discharge by deterioration time of XLPE sample was about proportion to output voltage of AE signals. When void was existed, charge magnitude of partial discharge, the output voltage Vp-p value of AE signals were increased with increasing deterioration time. However, when void were not existed, charge magnitude of partial discharge, the output voltage Vp-p value of AE signals were increased in fast deterioration time, but it were decreasing at after in middle deterioration time. Frequency spectrum response of AE signal was about 100-250[kHz].

  • PDF

A Study on Long-time Electrical Treeing Deterioration Properties According to High Frequency Voltage of Epoxy Resin (에폭시수지의 고전압 전원주파수 변화에 따른 장시간 전기적 트리잉 열화 특성연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1571-1577
    • /
    • 2013
  • Electrical tree structure is one of the most important influencing factors for electrical treeing characteristics in polymers. In this paper, we focused on the structure characteristics of electrical treeing in epoxy resins (original) insulation under different high-frequency voltages (60, 500, 1000Hz). Effects of voltage frequency on the ac electrical treeing phenomena in an epoxy resins were carried out in needle-plate electrode arrangement. To measure the treeing initiation and propagation, and the breakdown rate, constant AC of 10 kV with three different voltage frequencies (60, 500 and 1,000 Hz) was applied to the specimen in needle-plate electrode specimen at $30^{\circ}C$ of insulating oil bath. At 60 Hz, the treeing initiation time was 360 min and the propagation rate was $6.85{\times}10^{-4}mm/min$, and the morphology was dense branch type. As the voltage frequency increased, the treeing initiation time decreased and the propagation rate increased. At 1,000 Hz, the treeing initiation time was 0 min and the propagation rate was $7.81{\times}10^{-2}mm/min$, and the morphology was dense bush type.

Properties of PD Pulses accompanying with propagation of Bush-type tree in LDPE (LDPE에서 부시형 전기트리의 성장에 수반되는 부분방전 펄스의 특성)

  • 박영국;강성화;정수현;박철현;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.293-296
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition, The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level. the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF