• Title/Summary/Keyword: burn test

Search Result 216, Processing Time 0.028 seconds

A Development of Test Equipment for Thermal Protection Performance on Insulator used in Rocket Motor Chamber (연소관 내열고무의 내열성능평가를 위한 시험장치 개발)

  • Kang, YoonGoo;Park, JongHo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.3
    • /
    • pp.32-36
    • /
    • 2016
  • Test equipment was designed and manufactured to evaluate thermal reaction characteristic of internal insulators of solid rocket motor. Test is allowed up to chamber pressure 2,500 psi, burn-time 100 s. A cross section of test sample part is quadrature, and various test samples can be comparable at the same time. Inner temperature of test sample can be measured by thermocouples during burning. Test was executed in condition of efficient average chamber pressure 1,000 psi, efficient burn-time 10 s and safety of equipment was confirmed. Basic data for understanding thermal characteristics of internal insulator, that is, pressure-time curve, temperature-time curve in the test sample, and thermal destruction thickness of test sample was gained successfully.

Retrospective Analysis of the One-per-Million Tumescent Technique in Post-Burn Hand Deformity Surgeries

  • Prasetyono, Theddeus O.H.;Koswara, Astrid Felicia
    • Archives of Plastic Surgery
    • /
    • v.42 no.2
    • /
    • pp.164-172
    • /
    • 2015
  • Background The use of a tourniquet in hand surgery is generally accepted as necessary to create a clear visualization of the operative field. This study aims to determine the effectiveness of one-per-million tumescent solution (1:1,000,000 epinephrine concentration) in creating a bloodless operative field in post-burn hand deformity surgeries performed without a tourniquet. Methods This retrospective observational study was conducted on a series of 12 patients with post-burn hand deformities who underwent surgery between February 2013 and January 2014. A total of 29 operative fields were recorded. The one-per-million tumescent solution was used for hemostatis instead of a tourniquet. The clarity of the operative field, volume of solution injected, duration of surgery, scar thickness and density, and functional outcomes at least three months after the surgery were observed. The relationship of scar thickness and density with the clarity of the operative field was analyzed with the chi-square test. Results Of the 29 operative fields in which the one-per-million tumescent technique was used, 48.2% were totally bloodless, 44.8% had minimal bleeding, and 6.9% had an acceptable level of bleeding. Both scar thickness and density were shown to have a significant relationship with operative field clarity (P<0.05). Conclusions The one-per-million tumescent technique is effective in facilitating post-burn hand deformity surgeries involving meticulous, multiple, and lengthy procedures by creating a relatively clear operative field without the use of a tourniquet. Although scar thickness and density are associated with the clarity of the operative field, this technique can be considered safe and effective in creating a clear operative field.

Testing Spatial Autocorrelation of Burn Severity (산불 피해강도의 공간 자기상관성 검증에 관한 연구)

  • Lee, Sang-Woo;Won, Myoung-Soo;Lee, Hyun-Joo
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.2
    • /
    • pp.203-212
    • /
    • 2012
  • This study aims to test presence of spatial autocorrelation of burn severity in Uljin and Youngduk areas burned in 2011. SPOT satellite images were used to compute the NDVI representing burn severity, and NDVI values were sampled for 5,000 randomly dispersed points for each site. Spatial autocorrelations of sampled NDVI values were analyzed with Moran's I and Variogram models. Moran's I values of burn severity in Uljin and Youngduk areas were 0.7745 and 0.7968, respectively, indicating presence of strong spatial autocorrelations. On the basis of Variogram and changes of Moran's I values by lag class, ideal sampling distance were proposed, which were 566-2,151 m for Uljin and 272-402 m for Youngduk. It was recommended to apply these ranges of sampling distance in flexible corresponding to Anisotropic characteristics of burned areas.

Analysis of clothing pressure for commercially customized burn patient's medical compression garments for men in their 20s (시판 맞춤형 화상환자 압박복의 의복압 분석 -20대 남성 상의를 대상으로-)

  • Cho, Shin-Hyun
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.21 no.4
    • /
    • pp.55-67
    • /
    • 2019
  • This study analyzed the fabric and product size of the burn patient's custom compression garment and measured the pressure applied by the garment to assess whether proper pressure is being delivered for treatment. The test clothes were presented to the market by body size and commissioned with the same design. The subjects selected four people close to the average body size of men in their 20s determined by 7th Size Korea. The experiment was conducted by wearing a compression suit, performing activities and measuring changes in the pressure of the garment according to changes in posture. The fabric used for the compressive clothing was not ruptured even at 216 kPa, the elasticity recovery rate was measured between 80.5 and 94.5%. The product dimensions of the experimental clothing varied by up to 8cm from brand to brand, requiring the standardization of compression clothing. The experiment showed that four types of compression suit varied in pressure, and the pressure range, excluding the gastric arm (17.9mmHg), was between 2.5-14.1mmHg, which failed to meet the level of pressurization for treatment purposes. The clothing pressure in the chest area dropped when performing movements rather than standing still. This was interpreted to be a result of reduced the adhesion of the compression suit during operation. The peak pressure (31.68mmHg) and the lowest pressure (2.2mmHg) was noted in the scapula, indicating that no pressure was being transmitted on the vertebrae. The pressure of the garment on the right shoulder blade was elevated in a supine position. Because much time is spent laying down, it is necessary for the pattern design to accommodate for the increased clothing pressure on the shoulder blades. Standardization of the level of pressurization for burn patient's custom-made pressure suits for each stage of treatment is urgently required.

TETANUS TRISMUS ASSOCIATED WITH FACIAL ELETRICAL BURN (전기화상 환자에서 나타난 파상풍-증례보고)

  • Ha, Tae-Young;Kang, Jin-Han;Shin, Mee-Ran;Ahn, Byoung-Keun;Kim, Mi-Ja
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.4
    • /
    • pp.380-383
    • /
    • 2006
  • Tetanus is rare in Korea due to the introduction of vaccination programs and the advancement in public health. Its common signs are trismus, voice disturbance, neck stiffness, and difficulty in swallowing, etc. A 56 years old man was injured by grasping a high voltage electric cable. After the accident, he fell down on a steel plate and had a head trauma. When he visited Emergency Department, there was multiple electric burn wound on left arm and left facial area. He was hospitalized on a department of neurosurgery, because intra cranial hemorrhage was presumed. 12 days later, he was referred to department of OMFS with developed painful masseter spasms and trismus. That night he violently bit his tongue with his denture. Because masseter muscle and temporal muscle constriction was involuntary, tongue was lacerated and denture was distorted. At first we supposed that the symptom was related with neurologic disturbance following head trauma or electric shock. But it was revealed that trismus was caused by tetanus on an electrophysiological test. By using mechanical ventilation and administration of tetanus immunoglobulin, muscle-relaxant, and sedatives at ICU, symptoms had subsided (4-weeks). Because tetanus is rare disease, we rarely suppose tetanus infection to be a cause of a trismus. Especially it is more difficult to diagnose in patient who has head trauma, burn and neurologic problem as in this case.

A Development of Test Equipment for Thermal Protection Performance on Insulator used in Solid Rocket Motor (고체로켓 추진기관용 연소관단열재의 내열성능평가를 위한 시험장치 개발)

  • Kang, Yoongoo;Yun, Deokjin;Kim, Suyoung;Lee, Jongsung;Kwon, Taeha
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.543-546
    • /
    • 2017
  • Test equipment was designed and manufactured to evaluate thermal reaction characteristic of internal insulators of solid rocket motor. Test is allowed up to chamber pressure 2,500 psi, burn-time 40 s. It is possible to observe and to compare thermal reaction characteristic for a few materials simultaneously, under the condition that the ablation occurs. In efficient average chamber pressure 878 psi, efficient burn-time 10.7 s and gas velocity 100 m/s, test was executed for confirming safety of equipment, being 4 test materials inserted simultaneously. Basic data for understanding thermal characteristic of internal insulator, that is, pressure-time curve, temperature-time curve in the test sample, and thermal destruction depth of test samples was gained successfully.

  • PDF

Powdered Wound Dressing Materials Made from wild Silkworm Antheraea pernyi Silk Fibroin on Full-skin Thickness Burn Wounds on Rats

  • Kim, Min-Keun;Yoo, Ki-Yeon;Kwon, Kwang-Jun;Kim, Seong-Gon;Park, Young-Wook;Lee, Kwang-Gill;Jo, You-Young;Kweon, Hae-Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.3
    • /
    • pp.111-115
    • /
    • 2014
  • Purpose: This study evaluated powdered burn wound dressing materials from wild silkworm fibroin in an animal model. Methods: Fifteen rats were used in this experiment. Full-thickness $2{\times}2cm$ burn wounds were created on the back of rats under anesthesia. In the two experimental groups, the wounds were treated with two different dressing materials made from silkworm fibroin. In the Control Group, natural healing without any dressing material was set as control. The wound surface area was measured at five days, seven days and 14 days. Wound healing was evaluated by histologic analysis. Results: By gross observation, there were no infections or severe inflammations through 14 days post-injury. The differences among groups were statistically significant at seven days and 14 days, postoperatively (P<0.037 and 0.001, respectively). By post hoc test, the defect size was significantly smaller in experimental Group 1 compared with the Control Group and experimental Group 2 at seven days postoperatively (P=0.022 and 0.029, respectively). The difference between Group 1 and Group 2 was statistically significant at 14 days postoperatively (P<0.001). Group 1 and control also differed significantly (P=0.002). Group 1 showed a smaller residual scar than the Control Group and Group 2 at 14 days post-injury. Histologic analysis showed more re-epithelization in Groups 1 and 2 than in the Control Groups. Conclusion: Burn wound healing was accelerated with silk fibroin spun by wild silkworm Antheraea pernyi. There was no atypical inflammation with silk dressing materials. In conclusion, silk dressing materials can be used for treatment of burn wound.

LEAN-BURN ENGINE - POTENTIAL ANALYSIS

  • Kowalewicz, A.
    • International Journal of Automotive Technology
    • /
    • v.2 no.4
    • /
    • pp.147-155
    • /
    • 2001
  • Analysis of the thermodynamic cycle of IC engine from the point of view of economy and emissions was carried out. From this analysis potential capability of engine development was derived. This potential capability is lean-burn engine, fuelled with homogeneous mixture with $\lambda \geq$ 1.4. Several different modes of fuelling were proposed and tested on one-cylinder test engine from the point of view of extending lean operating limit of the engine, emissions and fuel economy. Among them were: fuelling with evaporated preheated gasoline, with gas (LPG evaporated) and with liquid butane. From these modes, fuelling with liquid butane injected to inlet port was selected and finally tested. This novel system of fuelling offered better than standard engine performances and emissions at lean operating limit. These results were validated on full-scale two-cylinder engine.

  • PDF