• 제목/요약/키워드: buried pipe inspection

검색결과 25건 처리시간 0.021초

ASME Code Case N-806을 활용한 매설배관 사용적합성 평가 고찰 (Technical Review on Fitness-for-Service for Buried Pipe by ASME Code Case N-806)

  • 박상규;이요섭;소일수;임부택
    • Corrosion Science and Technology
    • /
    • 제11권6호
    • /
    • pp.225-231
    • /
    • 2012
  • Fitness-for-Service is a useful technology to determine replacement timing, next inspection timing or in-service when nuclear power plant's buried pipes are damaged. If is possible for buried pipes to be aged by material loss, cracks and occlusion as operating time goes by. Therefore Fitness-for-Service technology for buried pipe is useful for plant industry to perform replacement and repair. Fitness-for-Service for buried pipe is studied in terms of existing code and standard for Fitness-for-Service and a current developing code case. Fitness-for-Service for buried pipe was performed according to Code Case N-806 developed by ASME (American Society of Mechanical Engineers).

지반의 수분 상태에 따른 매립 배관에서의 유도초음파 모드 감쇠 변화 (Effect of Moisture Conditions in Soils on Mode Attenuation of Guided Waves in Buried Pipes)

  • 이주원;신성우;나원배;김영상
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.42-47
    • /
    • 2010
  • Recently, many techniques have been developed for the inspection of pipelines using guided waves. However, few researches have been made on the application of those techniques for buried underground pipes. Guided wave motions in the buried pipes are somewhat different from those of on-ground pipes which have traction-free (air) boundary condition on outer pipe walls and thus are strongly affected by the mechanical property of the surrounding soils. Therefore, it should be investigated the effect of soil properties on the guided wave behavior in buried pipe. On the other hand, the mechanical property of soil is largely depending on its moisture conditions nevertheless of other influential factors such as void ratio. In this study, the effect of moisture conditions in soils on mode attenuation of guided waves in the buried pipe is investigated. To this end, numerical study is performed to characterize mode attenuation behavior in buried pipes and the effective mode which is suitable for long range inspection is identified.

딥러닝 알고리즘을 이용한 매설 배관 피복 결함의 간접 검사 신호 진단에 관한 연구 (Indirect Inspection Signal Diagnosis of Buried Pipe Coating Flaws Using Deep Learning Algorithm)

  • 조상진;오영진;신수용
    • 한국압력기기공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.93-101
    • /
    • 2023
  • In this study, a deep learning algorithm was used to diagnose electric potential signals obtained through CIPS and DCVG, used indirect inspection methods to confirm the soundness of buried pipes. The deep learning algorithm consisted of CNN(Convolutional Neural Network) model for diagnosing the electric potential signal and Grad CAM(Gradient-weighted Class Activation Mapping) for showing the flaw prediction point. The CNN model for diagnosing electric potential signals classifies input data as normal/abnormal according to the presence or absence of flaw in the buried pipe, and for abnormal data, Grad CAM generates a heat map that visualizes the flaw prediction part of the buried pipe. The CIPS/DCVG signal and piping layout obtained from the 3D finite element model were used as input data for learning the CNN. The trained CNN classified the normal/abnormal data with 93% accuracy, and the Grad-CAM predicted flaws point with an average error of 2m. As a result, it confirmed that the electric potential signal of buried pipe can be diagnosed using a CNN-based deep learning algorithm.

GPR을 이용한 토조의 공동 탐사 (Cavity Detection of Chamber by GPR)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권2호
    • /
    • pp.86-93
    • /
    • 2016
  • 본 연구에서는 토조에 설치한 관의 종류 및 매립 깊이, 공동 깊이 및 포장 조건 등에 대한 GPR(Ground Penetrating Radar) 탐사를 진행하여 매립관의 종류 및 공동 탐사 능력을 실험적으로 규명하였다. 아스팔트 포장 및 비포장의 경우, 콘크리트 포장 및 철근 콘크리트 포장 대비 매립관의 탐사가 용이한 것으로 평가되었다. 또한 공기 공동의 경우, 매립 깊이 1 m에서는 탐지가 가능한 것으로 평가되었다.

REAL-TIME CORROSION CONTROL SYSTEM FOR CATHODIC PROTECTION OF BURIED PIPES FOR NUCLEAR POWER PLANT

  • Kim, Ki Tae;Kim, Hae Woong;Kim, Young Sik;Chang, Hyun Young;Lim, Bu Taek;Park, Heung Bae
    • Corrosion Science and Technology
    • /
    • 제14권1호
    • /
    • pp.12-18
    • /
    • 2015
  • Since the operation period of nuclear power plants has increased, the degradation of buried pipes gradually increases and recently it seems to be one of the emerging issues. Maintenance on buried pipes needs high quality of management system because outer surface of buried pipe contacts the various soils but inner surface reacts with various electrolytes of fluid. In the USA, USNRC and EPRI have tried to manage the degradation of buried pipes. However, there is little knowledge about the inspection procedure, test and manage program in the domestic nuclear power plants. This paper focuses on the development and build-up of real-time monitoring and control system of buried pipes. Pipes to be tested are tape-coated carbon steel pipe for primary component cooling water system, asphalt-coated cast iron pipe for fire protection system, and pre-stressed concrete cylinder pipe for sea water cooling system. A control system for cathodic protection was installed on each test pipe which has been monitored and controlled. For the calculation of protection range and optimization, computer simulation was performed using COMSOL Multiphysics (Altsoft co.).

수치해석과 모형실험을 통한 매립배관에서의 유도초음파 L(0,2) 모드의 감쇠 특성 평가 (Attenuation Characterization of L(0,2) Guided Wave Mode through Numerical Analyses and Model Experiments with Buried Steel Pipe)

  • 이주원;나원배
    • 한국해양공학회지
    • /
    • 제27권1호
    • /
    • pp.16-23
    • /
    • 2013
  • By carrying out numerical analyses and model experiments, this paper presents the attenuation characterization of an L(0,2) guided ultrasonic wave propagating in a buried steel pipe. From this investigation, we first find that the L(0,2) mode has a better attenuation property. Second, it is shown from the numerical analyses that the attenuation increases with increases in the soil embedment length (0, 500, 1000, and 1500 mm) and degrees of saturation (0, 50, 99, and 100%). Third, it is also shown from the model experiment that the attenuation increases as the embedment lengths and soil moisture quantities (0, 10, 20, and 30 kg) increase. Finally, we find that an exponential extrapolation gives a better attenuation prediction because the extrapolation gives similar attenuation patterns between the numerical and experimental results.

3D 유한요소법을 이용한 원전 매설배관 부식결함 탐상기술 개발 (Technology for the Detection of Corrosion Defects in Buried Pipes of Nuclear Power Plants with 3D FEM)

  • 김재원;임부택;박흥배;장현영
    • Corrosion Science and Technology
    • /
    • 제17권6호
    • /
    • pp.292-300
    • /
    • 2018
  • The modeling of 3D finite elements based on CAD data has been used to detect sites of corrosion defects in buried pipes. The results generated sophisticated profiles of electrolytic potential and vectors of current distributions on the earth surface. To identify the location of defects in buried pipes, the current distribution on the earth surface was projected to a plane of incidence that was identical to the pipe locations. The locations of minimum electrolytic potential value were found. The results show adequate match between the locations of real and expected defects based on modeling. In addition, the defect size can be calculated by integrating the current density curve. The results show that the defect sizes were $0.74m^2$ and $0.69m^2$, respectively. This technology may represent a breakthrough in the detection of indirect damage in various cases involving multiple defects in size and shape, complex/cross pipe systems, multiple anodes and stray current.

다전극 탐상을 통한 토중 매설배관 피복결함 탐상 정확도의 개선 (Enhancing the Reliability of Coating Flaw Detection for Pipes Buried in Soil Using a Multi-Electrode Detector)

  • 김민기;임부택;김기태;장현영;박흥배;김영식
    • Corrosion Science and Technology
    • /
    • 제19권5호
    • /
    • pp.265-280
    • /
    • 2020
  • External corrosion of buried pipes can be controlled using both coating and cathodic protection. However, deterioration of the coating can occur due to several reasons. The detection reliabilty of coating flaw detection methods is affected by interference such as metal objects connected to rectifiers and copper grids. When performing parallel direct current voltage gradient (DCVG) inspection, a sine wave form without potential reversal in voltage gradient appears in the area where the interference exists. However, this area may be not identified using existing methods. The objective of this study was to determine the effect of analyzing direction on the reliability of coating flaw detection of pipes buried in soil using a multi-electrode detector. DCVG on the buried pipe was measured along the buried pipe. This measurement parallel to the pipe was repeated. Measured data were analyzed for parallel, vertical, and diagonal directions. The reliability of coating flaw detection was improved by up to 46.4% compared to the conventional method.

Attenuation of Fundamental Longitudinal Guided Wave Mode in Steel Pipes Embedded in Soil

  • Lee, Ju-Won;Shin, Sung-Woo;Na, Won-Bae
    • 비파괴검사학회지
    • /
    • 제30권6호
    • /
    • pp.539-547
    • /
    • 2010
  • In this study, characteristics of the fundamental longitudinal guided wave mode, L(0,1), which is a usual mode employed in the inspection of the above-ground pipe, of the buried pipe were numerically investigated considering property changes in the surrounding soil. Results showed that soil conditions are significantly affecting the attenuation of L(0,1) mode in the pipe embedded in soil. Especially, if the soil is partially saturated, the attenuation of L(0,1) mode is larger and is very similar regardless of the degree of water saturation in the surrounding soil. However, when the soil is fully saturated, the attenuation of L(0,1) mode is less and show different trend with its partially saturated counterparts.

외면부식 직접평가법 개발 및 국내 도입 연구 (The Development and Introduction of External Corrosion Direct Assessment Measures for Urban Gas Pipelines)

  • 류영돈;이진한;윤영기;임호석
    • 한국가스학회지
    • /
    • 제18권5호
    • /
    • pp.12-19
    • /
    • 2014
  • 매설배관의 부식위험성을 최소화하고 음극방식의 효율극대화를 위해 다양한 비굴착 간접검사기법들이 수십년 전부터 이용되고 있으며, 미국에서는 굴착을 통한 매설배관 외면부식 직접평가법을 CFR 코드에서 규정하고 있다. 국내의 경우에는 도시가스사업법 관련 4개의 기준(KGS Code)에서 배관의 손상여부를 측정할 수 있는 장비를 이용하여 배관의 상태를 점검, 측정하고 이상부위에 대하여 누출검사를 한 경우 매설배관의 기밀시험을 한 것으로 보고 있을 뿐 배관외면부식 직접평가에 대한 규정은 없다. 본 논문에서는 미국, 영국 등 국외의 매설배관 건전성 관리 기준 및 방법을 조사하고, 국내의 매설배관 방식관리 실태 및 피복손상탐지 장치 이용실태 등을 조사한 후 국내 실정에 맞는 매설배관 외면부식 직접평가법을 제시하였다. 본 논문에서 제시한 매설배관 외면부식 직접 평가법은 국내에서 중압배관의 정밀안전진단 제도를 도입하는데 기초 자료로 활용되었다.