• Title/Summary/Keyword: burial pipe

Search Result 37, Processing Time 0.071 seconds

Performance Evaluation of Buried Concrete Pipe under Heavy Traffic Load (교통하중하의 지하 매설관의 거동 평가)

  • Ban, Hoki;Park, Seong-Wan;Kim, Yong-Rak
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.12
    • /
    • pp.69-75
    • /
    • 2013
  • Pipeline is very important infrastructure which is directly related to our daily life. Nevertheless, it is not considered significantly unless it breaks. As most pipelines are buried at a certain depth from the surface of road pavement in urban areas, they are subjected to traffic load. This paper presents the performance of buried concrete pipe under heavy traffic load. Hence, one of the major factors affecting their performance is burial depth. To consider this factor, the ratio of burial depth (H) to diameter of pipe (D) was defined as a key variable. The integrity of buried concrete pipe was investigated with two cases of ratio of burial depth to pipe diameter (H/D=2 and H/D=4). The results provide the limit burial depth to ensure the soundness of buried concrete pipe subjected to heavy traffic load, and more economical design is anticipated with the results.

Self-Burial Structure of the Pipeline with a Spoiler on Seabed (해저지반에 설치된 스포일러 부착형 파이프라인의 자가매설 기능분석)

  • Lee, Woo-Dong;Hur, Dong-Soo;Kim, Han-Sol;Jo, Hyo-Jae
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.310-319
    • /
    • 2016
  • If a spoiler was attached to the pipeline investigated in a previous study, a strong flow and vortex at the lower part caused scouring and thus an asymmetric pressure distribution, which assisted in the analysis of the self-burial structure where a down force was applied to the pipe. However, only the fluid-pipe interaction was considered, excluding the medium (seabed), when practically burying the pipeline. Thus, this study applied a numerical model (LES-WASS-2D) to directly analyze the non-linear interactions among the fluid, pipe, and seabed in order to perform numerical simulations of a pipeline with a spoiler installed on the seabed. This allowed the self-burial mechanism of a pipeline with a spoiler to be analyzed in the same context as the previous study that considered only the fluid-pipe interaction. However, when a pipeline was installed on the seabed, a strong flow and vortex were found at the front of the bottom, and a spoiler accelerated the fluid resistances. This hydraulic phenomenon will reinforce the scouring and down force on the pipeline. In the general consideration of the numerical analysis results by the specifications and arrangements of the spoiler, a pipeline with a spoiler was found to be the most effective for the self-burial function.

A Study on Burial Guideline of Horizontal Geothermal Heat Exchanger based on Exit Temperature (출구 온도를 고려한 수평형 지중열교환기의 매설 지침에 관한 연구)

  • Cho, Sung-Woo;Ihm, Pyeong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.553-558
    • /
    • 2014
  • Geothermal energy can be used with a geothermal heat pump or an earth-to-air heat exchange system (EAHES), which is referred to as a "cooling tube" in Korea. In this study, we suggest EAHES burial guidelines in terms of the parameters of buried pipe length and air velocity regarding the exit air temperature of EAHES. The exit air temperature for EAHES in three regions (Changwon, Busan and Seoul) was calculated with variation in buried pipe length and air velocity at ${\Phi}100mm$ and ${\Phi}200mm$. In conclusion, variation in the buried pipe length is more effective than that of air velocity to achieve the required exit air temperature.

A scientific approach to estimate the safe depth of burial of submarine pipelines against wave forces for different marine soil conditions

  • Neelamani, S.;Al-Banaa, K.
    • Ocean Systems Engineering
    • /
    • v.3 no.1
    • /
    • pp.9-34
    • /
    • 2013
  • Submarine pipelines encounter significant wave forces in shallow coastal waters due to the action of waves. In order to reduce such forces (also to protect the pipe against anchors and dropped objects) they are buried below the seabed. The wave force variation due to burial depends on the engineering characteristics of the sub soil like hydraulic conductivity and porosity, apart from the design environmental conditions. For a given wave condition, in certain type of soil, the wave force can reduce drastically with increased burial and in certain other type of soil, it may not. It is hence essential to understand how the wave forces vary in soils of different hydraulic conductivity. Based on physical model study, the wave forces on the buried pipeline model is assessed for a wide range of wave conditions, for different burial depths and for four types of cohesion-less soils, covering hydraulic conductivity in the range of 0.286 to 1.84 mm/s. It is found that for all the four soil types, the horizontal wave force reduces with increase in depth of burial, whereas the vertical force is high for half buried condition. Among the soils, well graded one is better for half buried case, since the least vertical force is experienced for this situation. It is found that uniformly graded and low hydraulic conductivity soil attracts the maximum vertical force for half buried case. A case study analysis is carried out and is reported. The results of this study are useful for submarine buried pipeline design.

Test of Independence Between Variables to Estimate the Frequency of Damage in Heat Pipe (열수송관 파손빈도 추정을 위한 변수간 독립성 검정)

  • Myeongsik Kong;Jaemo Kang;Sungyeol Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.12
    • /
    • pp.61-67
    • /
    • 2023
  • Heat pipes located underground in urban areas and operated under high temperature and pressure conditions can cause large-scale human and economic damage if damaged. In order to predict damage in advance, damage and construction information of heat pipe are analyzed to derive independent variables that have a correlation with frequency of damage, and a simple regression analysis modified model using each variable is applied to the field. However, as the correlation between independent variables applied to the model increases, the independence between variables is harmed and the reliability of the model decreases. In this study, the independence of the pipe diameter, burial depth, insulation level of monitoring system, and disconnection or short circuit of the detection line, which are judged to be interrelated, was tested to derive a method for combining variables and setting categories necessary to apply to the frequency of damage estimation model. For the test of independence, the continuous variables pipe diameter and burial depth were each converted into three categories, insulation level of monitoring system was converted into two categories, and the categorical variable disconnection or short circuit of the detection line status was kept as two categories. As a result of the test of independence, p-value between pipe diameter and burial depth, level of monitoring system and disconnection or short circuit of the detection line was lower than the significance level (α = 0.05), indicating a large correlation between them. Therefore, the pipe diameter and burial depth were combined into one variable, and the categories of the combined variable were set to 9 considering the previously set categories. The insulation level of monitoring system and the disconnection or short circuit of the detection line were also combined into one variable. Since the insulation level is unreliable when the detection line status is disconnection or short circuit, the categories of the combined variable were set to 3.

Experimental investigation of the effects of pipe location on the bearing capacity

  • Bildik, Selcuk;Laman, Mustafa
    • Geomechanics and Engineering
    • /
    • v.8 no.2
    • /
    • pp.221-235
    • /
    • 2015
  • A series of laboratory model tests were conducted to investigate the effects of buried pipes location on the bearing capacity of strip footing in cohesionless soil. The variables examined in the testing program include relative density of the sand, loading rate of tests, burial depths of pipe and horizontal distance of pipe to footing. The test results showed a significant increase in bearing capacities when embedment ratio of pipe and horizontal distance of pipe to footing were increased. Based on the test results, it can be concluded that the location of pipes and relative density of sand are main parameters that affect the bearing capacity of strip footing. However, loading rate has not considerable effect on bearing capacity.

Stress Distribution of Buried Concrete Pipe Under Various Environmental Conditions

  • Lee, Janggeun;Kang, Jae Mo;Ban, Hoki;Moon, Changyeul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.12
    • /
    • pp.65-72
    • /
    • 2016
  • There are numerous factors that affect stress distribution in a buried pipe, such as the shape, size, and stiffness of the pipe, its burial depth, and the stiffness of the surrounding soil. In addition, the pipe can benefit from the soil arching effect to some extent, through which the overburden and surcharge pressure at the crown can be carried by the adjacent soil. As a result, the buried pipe needs to support only a portion of the load that is not transferred to the adjacent soil. This paper presents numerical efforts to investigate the stress distribution in the buried concrete pipe under various environmental conditions. To that end, a nonlinear elasto-plastic model for backfill materials was implemented into finite element software by a user-defined subroutine (user material, or UMAT) to more precisely analyze the soil behavior surrounding a buried concrete pipe subjected to surface loading. In addition, three different backfill materials with a native soil were selected to examine the material-specific stress distribution in pipe. The environmental conditions considering in this study the loading effect and void effects were investigated using finite element method. The simulation results provide information on how the pressures are redistributed, and how the buried concrete pipe behaves under various environmental conditions.

Water Quality Monitoring through Tube-Well Survey at Foot-and-mouth Disease Carcass Disposal Sites (구제역 가축매몰지 인근 지하수 관측정 수질 모니터링)

  • Huh, In-Ryang;Kim, Kei-Woul;Choi, Geum-Jong;Lee, Teak-Soo
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.1
    • /
    • pp.47-54
    • /
    • 2014
  • Objectives: The purpose of this study is to evaluate the characteristics of leachate discharged from livestock burial sites in Gangwondo resulting from foot-and-mouth disease by monitoring the water quality at the survey tube-wells installed near livestock burial sites in order to investigate the effect of the leachate on the quality of nearby underground water and suggest a water pollution level in accordance with water quality evaluation criteria. Methods: To minimize the secondary environmental pollution damage caused by leachate at burial sites of livestock killed by foot-and-mouth disease, this study analyzed the leachate directly discharged from burial sites and installed survey tube-wells within 300 meters of livestock burial sites and investigated water quality as a means to ascertain the environmental effect of the leachate from the burial sites. In accordance with environmental management guidelines on livestock burial sites, this research investigated the water quality in the survey tube-wells in fifty five burial sites in Gangwondo. The elements investigated were $NH_3$-N, $Cl^-$, $NO_3$-N, conductivity, and E. coli. Water quality was monitored from 2011 to 2013. Results: The water quality from the drain pipe at the location of leachate from livestock burial sites showed BOD 37,209 mg/L, COD 8,829 mg/L, $NH_3$-N 3,633 mg/L, and $Cl^-$ 580 mg/L. According to the monitoring results of water quality ($Cl^-$, $NH_3$-N, conductivity) at the survey tube-wells, there was suspicion that 13 out of 55 burial sites discharged leachate, five sites discharged highly concentrated leachate (13%): one in Gangneung, one in Wonju, and three in Cheorwon. Conclusion: It was judged that out of thirteen observation wells which showed a possibility of discharged leachate, three survey tube-wells have established the discharge effect of leachate at burial sites up to recently. Therefore, it is judged that it is necessary to continue monitoring them and devise additional measures.

Continuous Variable Regression Analysis for Frequency of Damage Analysis in Heat Pipe (연속형 변수 회귀분석을 통한 열수송관 파손빈도 분석)

  • Myeongsik Kong;Jaemo Kang;Sungyeol Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.12
    • /
    • pp.47-52
    • /
    • 2023
  • In order to efficiently maintain heat pipes operated by district heating operators, the facility history and damage history data built by the operator are used to identify key independent variables that are related to the occurrence of damage. Afterwards, the correlation with the frequency of damage was analyzed, and a basic model for estimating the frequency of damage was derived. Considering the correlation with the estimation model based on the use time currently being used by domestic and foreign district heating operators, a simple regression analysis basic model was presented as the independent variable with the highest correlation between continuous variables such as the use time, pipe diameter, burial depth, and insulation level of monitoring system, and the frequency of damage. The remaining independent variables were reflected as factors that modify and supplement the basic model. As a result of the analysis, as in previous research cases, it was confirmed that the analysis model between use time and frequency of damage had the highest correlation between the two variables and could be used as a basic model. Pipe diameter, burial depth, and insulation level of monitoring system information have also been confirmed to have a correlation with the frequency of damage, so they can be used as factors to supplement the basic model.

Experimental Assessment for the Effect of Burial Depth on the Formation of Underground Cavities and Ground Cave-ins by Damaged Sewer Pipes (하수관 손상으로 인한 지하공동 및 지반함몰 발생에 대한 하수관 매립심도 영향의 실험적 평가)

  • Kwak, Tae-Young;Chung, Choong-Ki;Kim, Joonyoung;Lee, Minho;Woo, Sang-Inn
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.11
    • /
    • pp.37-49
    • /
    • 2019
  • In order to analyze the effect of burial depth on the generation of ground cavities and cave-ins, a series of model experiments with different height of model ground were performed. Digital images of the model ground were captured to evaluate the internal deformation of the model grounds by adopting the PIV (Particle Image Velocimetry) technique. Additionally, the vertical displacement at the surface, the size of the cavity, and the weight of the discharged soil were measured in each test. The results indicate that the model ground with low burial depth, which does not satisfy the criterion, was more vulnerable to ground cavities and cave-ins than the model ground with high burial depth.