• 제목/요약/키워드: built-up square tube

검색결과 18건 처리시간 0.021초

Experimental study on axial compressive behavior of welded built-up CFT stub columns made by cold-formed sections with different welding lines

  • Naghipour, Morteza;Yousofizinsaz, Ghazaleh;Shariati, Mahdi
    • Steel and Composite Structures
    • /
    • 제34권3호
    • /
    • pp.347-359
    • /
    • 2020
  • The objective of this study is to experimentally scrutinize the axial performance of built-up concrete filled steel tube (CFT) columns composed of steel plates. In this case, the main parameters cross section types, compressive strength of filled concrete, and the effect of welding lines. Welded built-up steel box columns are fabricated by connecting two pieces of cold-formed U-shaped or four pieces of L-shaped thin steel plates with continuous penetration groove welding line located at mid-depth of stub column section. Furthermore, traditional square steel box sections with no welding lines are investigated for the comparison of axial behavior between the generic and build-up cross sections. Accordingly, 20 stub columns with thickness and height of 2 and 300 mm have been manufactured. As a result, welding lines in built-up specimens act as stiffeners because have higher strength and thickness in comparison to the plates. Subsequently, by increasing the welding lines, the load bearing capacity of stub columns has been increased in comparison to the traditional series. Furthermore, for specimens with the same confinement steel tubes and concrete core, increment of B/t ratio has reduced the ductility and axial strength.

중심압축력을 받는 건축구조용 고성능강(HSA800) 용접 각형강관 압축재의 국부좌굴 (Local Buckling of Built-up Square Tubular Compression Members Fabricated with HSA800 High Performance Steels under Concentric Axial Loading)

  • 유정한;김주우;양재근;강주원;이동우
    • 한국강구조학회 논문집
    • /
    • 제24권4호
    • /
    • pp.435-442
    • /
    • 2012
  • 최근 구조물의 고층화, 대형화 및 장스팬 활용 등의 요구로 고강도 고성능 재료의 건축물과 교량에의 적용이 증가하는 추세이다. 본 논문은 고성능강의 건축구조용 재료 특성과 고성능강재를 사용한 부재의 설계 기준을 위한 기본적인 연구의 일부이다. HSA800은 한국산업표준의 요건과 비교하였다. 용접 각형강관 기둥의 국부좌굴 거동과 현행 판폭두께비 설계 제한치를 검토 위하여 다양한 판폭두께비 변수를 계획하고, 단축압축실험을 실시하였다. 또한, 유한요소결과로 얻어낸 단주의 국부좌굴거동을 실험결과와 비교하였다.

시공단계를 고려한 피복충전형 콘크리트충전 각형기둥의 구조적 거동 분석 (Structural Behavior Analysis of Concrete Encased and Filled tube Square Column with Construction Sequence)

  • 김선희;염경수;최성모
    • 한국강구조학회 논문집
    • /
    • 제27권1호
    • /
    • pp.43-52
    • /
    • 2015
  • 구조물의 기둥은 층에 따라 받는 내력이 상이함에도 시공의 오차를 줄이고 구조설계의 편의를 위해 상부층부터 하부층의 기둥단면은 동일하게 설계되고 있다. 그럼에도 불가피하게 상하부의 기둥의 단면이 상이하는 경우가 발생된다. 예를들어 초고층 구조물 또는 증축 및 보수에 의해 기둥을 보강할 경우이다. 이렇듯. 선 기둥과 후 피복이 되는 기둥을 피복충전형 콘크리트 충전기둥이라 할 때, 가력조건이 다르므로 재하상태를 나뉘어 구조적 안정성을 확인할 필요가 있다. 그럼에도 국내외적으로 가력조건에 따른 합성기둥에 대한 내력과 변형연구는 전무한 상태에 있다. 따라서 본 연구에서는 구조실험을 통해 가력조건 및 콘크리트 강도, 피복두께 변화에 의한 피복충전형 콘크리트 각형 기둥의 내력과 거동을 분석하였다.

Stress-transfer in concrete encased and filled tube square columns employed in top-down construction

  • Kim, Sun-Hee;Yom, Kyong-Soo;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제22권1호
    • /
    • pp.63-77
    • /
    • 2016
  • Top-down construction is a construction technique in which pit excavation and structure construction are conducted simultaneously. Reducing construction time and minimizing noise and vibration which affect neighboring structures, the technique is widely employed in constructing downtown structures. While H-steel columns have been commonly used as core columns, concrete filled steel tube (CFT) columns are at the center of attention because the latter have less axial directionality and greater cross-sectional efficiency than the former. When compared with circular CFT columns, square CFT columns are more easily connected to the floor structure and the area of percussion rotary drilling (PRD) is smaller. For this reason, square CFT columns are used as core columns of concrete encased and filled square (CET) columns in underground floors. However, studies on the structural behavior and concrete stress transfer of CET columns have not been conducted. Since concrete is cast according to construction sequence, checking the stress of concrete inside the core columns and the stress of covering concrete is essential. This paper presents the results of structural tests and analyses conducted to evaluate the usability and safety of CET columns in top-down construction where CFT columns are used as core columns. Parameters in the tests are loading condition, concrete strength and covering depth. The compressive load capacity and failure behavior of specimens are evaluated. In addition, 2 cases of field application of CET columns in underground floors are analyzed.

용접조립 각형 CFT 기둥-보 외다이아프램 접합부의 구조특성 (Structural Characteristics of Welded Built-up Square CFT Column to Beam Connections with External Diaphragm)

  • 이성희;정헌모;김대중;김진호;최성모
    • 한국강구조학회 논문집
    • /
    • 제20권6호
    • /
    • pp.711-722
    • /
    • 2008
  • 기존 콘크리트충전 각형강관(CFT) 구조에 사용하는 각형강관은 4개의 판을 용접하여 제작하는 박스칼럼이 일반적이다. 그러나 이러한 강관은 제작효율이 저하되며, 또한 기둥-보 접합부에는 내측 다이아프램과 관통 다이아프램을 용접하는데 특수한 용접기술이 필요하다. 따라서, 얇은 강판을 절곡하는 방식으로 응력집중 위치의 용접을 피하고, 단면효율이 극대화된 내부앵커 돌출형의 각형강관을 개발하게 되었다. 본 연구에서는 이 개발된 강관의 기둥-보 접합부로 외다이아프램형식을 채택하고. 보 플랜지의 응력 전달을 명확히 하기 위한 기둥-보 접합부 상세를 확 정하고자 이 접합부에 대한 단순인장 실험체를 제작하여 성능평가 실험을 수행하였다. 이 실험을 통해 콘크리트충전 기둥-보 접합부의 기둥-보 플랜지 용접 유무, 기둥-다이아프램 용접량, 콘크리트 충전유무, 다이아프램 설치 기둥과 일반기둥의 비교 등에 따른 인장영역 응력분포 및 내력평가를 진행하고 내부 앵커와 콘크리트 사이의 합성효과를 파악하였다.

건축구조용 냉간성형 강관의 가공성능 평가 (Evaluation of Forming Performance of Cold Rolled Steel Pipes & Tubes for Building Structure)

  • 임성우;최광;장인화
    • 한국강구조학회 논문집
    • /
    • 제16권1호통권68호
    • /
    • pp.33-42
    • /
    • 2004
  • SN 강재를 건축구조용으로 사용하기 위해서는 설계기준강도가 제정되어야 한다. 선행 연구로써, SN400B/490B 후판재로 재판한 SN400B/490B 원형강관과 SPAP235/325 및 SPAR295 각형강관의 물성을 평가하였다. SN400B/490B 후판재와 비교했을 때 STKN400B/490B 원형강관의 항복인장 및 인장강도는 상승하였지만, 제조 프로세스에 무관하게 STKN400B/490B 원형강관의 규격을 만족 하였다. 그러나 SPAP235/325 각형강관 모서리부에서의 항복인장 및 인장강도는 규격을 벗어났다. 이것은 SPAP235/325 각형강관 규격에서 정하고 있는 값이 모서리부에서의 값이 아니라 변에서의 값이기 때문이다. STKN490B 원형강관에 발생한 최대 인장잔류응력은 모재 항복강도 수준이며, 최대 압축잔류응력은 모재 항복강도의 40% 수준이었다. 또한 SPAP325 각형강관에 발생한 최대 인장잔류응력과 최대 압축잔류응력은 모두 모재 항복강도의 80% 수준이었다. 중심압축실험을 한 결과 STKN490B 원형강관의 좌굴강도는 제조 프로세스에 관계없이 별 차이를 보이지 않았다. 그러나 각형강관의 경우는 SPAP325 각형강관이 SN490B로 built-up한 각형강관보다 좌굴강도가 높게 나타났다.

내화성능 개선을 위한 강섬유 보강 내부 앵커형 각형강관 합성기둥의 실험연구 (An Experimental Study of Improving Fire Performance with Steel-fibers for Internally Anchored Square Composite Columns)

  • 김선희;염경수;김용환;최성모
    • 한국강구조학회 논문집
    • /
    • 제26권6호
    • /
    • pp.499-509
    • /
    • 2014
  • 본 연구에서는 해결방안으로 내부 콘크리트를 강섬유와 혼입하여 기둥자체의 연성과 인성을 증대시키는 것에 중점을 맞추고 있다. 즉, 강섬유 혼입량과 하중조건에 따른 내력 및 변형능력을 종합적으로 파악하여 강섬유 콘크리트와 용접조립각형 강관기둥의 상호작용을 구조, 내화측면에서 분석해 보고자 한다. 동일한 형상과 경계조건(하중비)에서 강섬유 혼입(0.375%)으로 내화성능은 약 1.1~1.3배 향상된 실험결과를 얻을 수 있었다. 강섬유 콘크리트의 균열 억제 특성은 열 하중에 의한 콘크리트의 변형저항 성능을 증가 시키면서 내화성능의 향상을 가져온 것으로 판단된다. 또한, 내부 리브의 열 변형에도 내부 콘크리트 단면은 건전한 상태로 남아있어 하중 분담능력이 증폭된 결과로 분석됐다.

강섬유 콘크리트 혼입율에 따른 내부앵커형 콘크리트 충전기둥 내화성능에 관한 해석적 연구 (Analysis Study on Fire Performance with Internal Anchored Concrete Filled Steel Tube Columns According to Percent of Steel-Fibers)

  • 김선희;염경수;김용환;최성모
    • 한국강구조학회 논문집
    • /
    • 제28권1호
    • /
    • pp.23-34
    • /
    • 2016
  • 콘크리트 충전강관 기둥은 강관의 구속효과에 의해 콘크리트의 압축내력 상승과, 콘크리트에 의한 강관의 국부좌굴 보강효과에 의해 부재내력이 상승하고 뛰어난 변형성능을 발휘한다. 하지만, 기둥단면이 커질 경우 합성효과를 발휘하기 위하여 스터드 볼트나 후 시공 앵커 볼트를 사용해야 하는 시공상의 문제점이 발생된다. 이를 극복함과 동시에 합성효과를 증대시키기 위한 방안으로 내부에 리브가 설치된 용접조립 기둥이 소개되었다. 내부 리브는 콘크리트와 맞물려 있어 리브의 변형은 콘크리트의 균열을 촉진시키는 역할을 동반하게 된다. 이러한 잠재적인 문제에 대한 해결책은 강관 리브의 변형에 저항할 수 있도록 콘크리트 인성을 증가시킬 수 있는 방안이 필요하다. 언급된 두 가지의 문제점이 효과적으로 해결될 경우 용접조립 각형강관 기둥은 내화성능 확보가 가능하다고 판단된다. 본 연구에서는 해결방안으로 내부 콘크리트를 강섬유와 혼입하여 기둥 자체의 연성과 인성을 증대시키는 것에 중점을 맞추고 있다. 내화성능 평가를 위한 시험체는 총 8개 로 하중비에 따른 재하가열 실험을 실시하고 화재 전후 거동과 열 변형 능력을 주요변수별로 분석하였다. 실험결과와 선행연구 비교를 통해 열 전달과 열응력 해석 모델의 신뢰성을 확보하였으며, 강섬유 혼입율에 따른 변수해석을 수행하였다.