• Title/Summary/Keyword: building-up construction

Search Result 957, Processing Time 0.028 seconds

Experimental Study on the Fire Resistance of SC Composite Coloumn (SC 합성기둥의 내화성능에 대한 실험연구)

  • Lee, Sueng Jea;Kang, Seong Deok;Oh, Myoung Ho;Kim, Myeong Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.4
    • /
    • pp.425-434
    • /
    • 2007
  • The SC (steel-concrete) composite column was developed to take advantage of the relative economy of using concrete as opposed to steel in carrying large compressive forces. As the SC composite column is pre-fabricated, its use can minimize laborand can speed up the erection of a steel building. In this study, an experiment was conducted to analyze the influence of several parameters, such as the load ratio, the concrete ratio of an area, and its performance with or without fire protection, on the performance of the SC composite column. This paper proposes that the calculation of the strength reduction ratios of columns be done by increasing the temperature. Theoretical equations were used to evaluate the effectiveness of the fire resistance of the SC composite column, and the results of the test and analysis were compared. The fire resistance of the SC composite column was increased by decreasing its load ratio, but the concrete ratio of an area has minimal influence on the fire resistance of the SC composite column.

A Study on the Accident Reduction Method through Survey of Hanging Scaffolding Use in Building Construction (건축공사 달비계 사용 실태조사를 통한 사고저감 방안 연구)

  • Lim, Hyoung-Chul;Lee, Dong-Heon;Jeong, Seong-Choon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.121-126
    • /
    • 2019
  • Despite the trend of decreasing accidents, falling accidents in the construction industry have not decreased and are even rising. Most major accidents are falling accidents caused by hanging scaffolding and are mostly serious. We conducted a review of the literature, institutions, and regulations, which showed that domestic standards are not unified because they are drawn up by referring to overseas standards for hanging scaffolding. New regulations or standards should be established, which should reflect the safety plans for equipment, work advance plans, education, and management. If facility improvement plan for Hanging Scaffolding and implementation of revision of the current work use, regulations and guides are implemented, it will be recognized in advance of the causes of the accident statistics and the classification system and will be the basis for the implementation of joint efforts by workers, managers, supervisors and owners to reduce accidents.

Study on the Distribution Status of Construction Aggregates in Incheon Metropolitan City and Nearby Areas (인천광역시 및 인근 지역의 건설용 골재 유통현황 분석 연구)

  • Chul-Seoung Baek;Byoung-Woon You;Kun-Ki Kim;Yu-Jeong Jang;Jin-Young Lee
    • Economic and Environmental Geology
    • /
    • v.57 no.2
    • /
    • pp.219-231
    • /
    • 2024
  • A survey of concrete plants in Incheon Metropolitan City and Gyeonggi Province was used to conduct an analysis of aggregate transport distance and production forms, as well as to evaluate the features and current status of aggregates distribution. As a result, areas such as Incheon, Siheung, Bucheon, Gimpo, and Siheung, where the distance to the demand points is less than 20 km, exhibited bidirectional distribution whereas Paju, Yongin, Yangju, and Pocheon, with distances ranging from 20 to 50 km is showed a unidirectional distribution pattern supplying aggregates exclusively to Incheon. Survey on manufacturing forms, more than 85% of the gravel dispersed in the Incheon area is made up of crushed aggregates derived from rocks discharged at construction sites indicating a considerable skew in supply chain. These findings are predicted to have a detrimental influence on aggregate supply in the long run, necessitating policy changes targeted at building an optimal aggregate distribution market.

The Effect of the Performance of Firefighting Construction Supervision Personnel on the Completion Inspection of Firefighting Facility Construction in Apartments (소방공사감리원의 업무수행능력이 아파트 소방시설공사의 완공검사에 미치는 영향)

  • Kim, Sang-Sig;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.43-54
    • /
    • 2019
  • In this study, results of completion inspection are investigated according to the performance of the firefighting construction supervision personnel and according to the necessity of clean air supply in a performance test of the firefighting construction supervision personnel. The results of the completion inspection are measured and the causes of defects in the fire protection facilities after issuance of a completion inspection certificate are analyzed. The findings of this investigation can be used to minimize the risk of apartment fires and improve the performance of firefighting construction supervision personnel. The results of this study are summarized as follows. First, the results of the completion inspection conducted by the firefighting construction supervision personnel varies according to particular occupation. The performance of fire facility supervisors from design companies and fire construction companies were significantly higher than the fire officers. Therefore, it is necessary to employ supervisors who have experience in supervising the construction of apartments, in order to improve the performance of fire construction supervision officers. Second, the analysis of the completion inspection results according to the necessity of a clean air supply for performance tests of firefighting construction supervision personnel showed that the necessity of a clean air supply was significantly higher for fire facility supervisors from design companies and fire construction companies than for the fire officers. In order to improve, the completion inspection should be carried out up until the completion date of the building. In addition, a system needs to be established to ensure that clients are not able to demand that a completion inspection certificate be issued on the construction completion date. Finally, it is found that defects of completion inspection after issuance of a completion inspection certificate affects the result of the completion inspection. The results of the completion inspections conducted by the fire facility supervisors from design companies and fire construction companies were affected significantly less by defects than that of the general contractors. Research shows that faults have occured in firefighting facilities after the issuance of a completion inspection certificate due to the client and the construction company demanding the issuance of the completion inspection certificate.

A Feasibility Study for Measuring Seismic Acceleration and Building Seismological Observatory (지진가속도 계측 및 지진관측소 구축 타당성 연구)

  • Han, Sang-Mok;Woo, Nam-Sub;Ha, Ji-Ho;Kim, Tea Woo;Lee, Wang-Do;Kim, Ki-Seog;Yang, Jae-Yeol;Kim, Young-Ju
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.411-417
    • /
    • 2020
  • Therefore, it was agreed that an earthquake monitoring station should be set up within the site of Handong University by analyzing drilling data and Disaster such as earthquakes is urgently needed to prepare for earthquakes in that people's lives and national development depend on the nation's ability to manage disasters. Many experts say that the Korean Peninsula is also under the influence of earthquakes and is not a safe zone for earthquakes. A seismological observatory will be established in Pohang to monitor ground sensors and study seismic characteristics through the task of "Development of Smart Sensor-based Intelligent Information Platform in Earthquake Region." Therefore, it was agreed to set up a seismological observatory within the site of Handong University by analyzing drilling data and conducting on-site surveys in northern Pohang, which were heavily damaged by liquefaction and earthquakes. In this study, it was decided to make a comprehensive judgment by considering the geological characteristics of the site, whether it can perform functions, and the convenience of construction and maintenance for the final site of the seismological observatory discussed with Handong University. After completing a feasibility review on selecting a site for Handong University, we will establish a seismological observatory and actively utilize it for seismic research using data from alarm issuance and seismic data in the event of a future earthquake.

Genesis of Artificial Strains Based on Microbial Genomics

  • Kim, Sun-Chang;Sung, Bong-Hyun;Yu, Byung-Jo
    • Proceedings of the Korean Society for Applied Microbiology Conference
    • /
    • 2001.06a
    • /
    • pp.15-19
    • /
    • 2001
  • Creating an artificial strain with a minimal gene set for a specific purpose is every biologist's dream. With the complete genome sequencing of more than 50 microorganisms and extensive functional analyses of their genes, it is possible to design a genetic blueprint for a simple custom-designed microbe with the minimal gene set. Two different approaches are being considered. The first 'top-down' approach is trimming the genome to a minimal gene set by selectively removing genes of an organism thought to be unnecessary based on microbial genomics. The second 'bottom-up' approach is to synthesize the proposed minimal genome from basic chemical building blocks. The 'top-down' approach starting with the genome of a well known microorganism is more technically feasible, whereas the bottom-up approach may not be attainable in the nearest future because of the lack of the complete functional analysis of the genes needed for a life. Here in this study, we used the top-down approach to minimize the E. coli genome to create an artificial organism with 'core' elements for self-sustaining and self-replicating cells by eliminating unnecessary genes. Using several different kinds of sophisticated deletion techniques combined with a p:1age and transposons, we deleted about 19% of the E. coli genome without causing any damages to cellular growth. This smaller E. coli genome will be further reduced to a genome with a minimal gene l;et essential for cell life. This minimized E. coli genome can lead to the construction of many custom-designed strains with myriad practical and commercial applications.

  • PDF

Characteristics of Wave by Additional Installation of Porous Dual Circular Caissons on the Existing Breakwater (기존 방파제에 투과성 이중 원형케이슨 추가설치에 따른 파랑 특성 분석)

  • Park, Min Su
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.6
    • /
    • pp.396-410
    • /
    • 2020
  • The design and the construction are carried out by installation of new caissons on the back or the front of existing caissons to increase the stability of existing caisson breakwater. In this study, we use the eigenfunction expansion method to analyze the effects of wave structure interaction when new porous dual circular caissons are installed on the back or the front of existing breakwater. The porous dual circular caisson which consisting of a porous outer cylinder circumscribing an impermeable inner cylinder is one type of seawater exchanging breakwater. The comparison of numerical results between present method and Sankarbabu et al. is made, and the wave force and the wave run-up acting on each porous dual circular caisson are calculated for various parameters by considering the wave structure interaction.

Proposal of Return Period and Basic Wind Speed Map to Estimate Wind Loads for Strength Design in Korea (강도설계용 풍하중 평가를 위한 재현기간과 기본풍속지도의 제안)

  • Ha, Young-Cheol
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.29-40
    • /
    • 2018
  • Strength design wind loads for the wind resistance design of structures shall be evaluated by the product of wind loads calculated based on the basic wind speed with 100 years return period and the wind load factor 1.3 specified in the provisions of load combinations in Korean Building Code (KBC) 2016. It may be sure that the wind load factor 1.3 in KBC(2016) had not been determined by probabilistic method or empirical method using meteorological wind speed data in Korea. In this paper, wind load factors were evaluated by probabilistic method and empirical method. The annual maximum 10 minutes mean wind speed data at 69 meteorological stations during past 40 years from 1973 to 2012 were selected for this evaluation. From the comparison of the results of those two method, it can be found that the mean values of wind load factors calculated both probability based method and empirical based method were similar at all meteorological stations. When target level of reliability index is set up 2.5, the mean value of wind load factors for all regions should be presented about 1.35. When target level of reliability index is set up 3.0, wind load factor should be presented about 1.46. By using the relationship between importance factor(conversion factor for return period) and wind load factor, the return periods for strength design were estimated and expected wind speeds of all regions accounting for strength design were proposed. It can be found that return period to estimate wind loads for strength design should be 500 years and 800 years in according to target level of reliability index 2.5 and 3.0, respectively. The 500 years basic wind speed map for strength design was suggested and it can be used with a wind load factor 1.0.

Study on Structure Visual Inspection Technology using Drones and Image Analysis Techniques (드론과 이미지 분석기법을 활용한 구조물 외관점검 기술 연구)

  • Kim, Jong-Woo;Jung, Young-Woo;Rhim, Hong-Chul
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.6
    • /
    • pp.545-557
    • /
    • 2017
  • The study is about the efficient alternative to concrete surface in the field of visual inspection technology for deteriorated infrastructure. By combining industrial drones and deep learning based image analysis techniques with traditional visual inspection and research, we tried to reduce manpowers, time requirements and costs, and to overcome the height and dome structures. On board device mounted on drones is consisting of a high resolution camera for detecting cracks of more than 0.3 mm, a lidar sensor and a embeded image processor module. It was mounted on an industrial drones, took sample images of damage from the site specimen through automatic flight navigation. In addition, the damege parts of the site specimen was used to measure not only the width and length of cracks but white rust also, and tried up compare them with the final image analysis detected results. Using the image analysis techniques, the damages of 54ea sample images were analyzed by the segmentation - feature extraction - decision making process, and extracted the analysis parameters using supervised mode of the deep learning platform. The image analysis of newly added non-supervised 60ea image samples was performed based on the extracted parameters. The result presented in 90.5 % of the damage detection rate.

A Study on Resolving Shadow Area of LoRa-based Communication for Workplace Safety (작업현장의 안전을 위한 LoRa기반 통신의 음영지역 해소를 위한 연구)

  • Kim, Seungyong;Kim, Dongsik;Hwang, Incheol;Kim, Kyoungsoo;Kim, Gyoungyong
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.402-410
    • /
    • 2020
  • Purpose: The purpose of this research is to eliminate communication shadowing loss of the 'smart safety management system'. The 'smart safety management system' can monitor and relay real time data of workers working in high risk workplace (i.e: industrial scene, disaster scene). The data will provide the rescue team the 'golden hour' in their rescue operations. Method: In this research, safety tag was designed and implemented so that it acts as a repeater for the user. Result: In other words, when communication in-between the safety tag and headquarters' communication terminal is jeopardized, the safety tag will act as a repeater-terminal for other safety tags in the area. Conclusion: The research tested if a specific building with communication shadowing loss problem was resolved when safety tags were implemented. Communication shadowing was first identified in-between the safety tag and headquarters' communication terminal. When extra safety tags were deployed in the same situation, the results showed that the communication shadowing loss was resolved. The repeater safety tags could resolve communication shadowing loss of up to three basement levels in this test building.