• 제목/요약/키워드: building transmission loss

검색결과 55건 처리시간 0.025초

농촌주택표준설계도 에너지효율등급평가 및 설계변수에 따른 에너지소요량 변화에 관한 연구 (A Study on Energy Requirement Variation According to Energy Efficiency Rating Evaluation and Design Variable of Standard Design of Rural Houses)

  • 박미란;류연수;최정만;서혜원
    • 한국농촌건축학회논문집
    • /
    • 제19권2호
    • /
    • pp.9-16
    • /
    • 2017
  • The study analyzed the heat losses and the building energy efficiency grade by the energy simulation using the ENERGY# and ECO2 programs for the three types of Standard design of rural houses. It was calculated the energy efficiency rating by the ECO2 program for the rural housing standard design, and the energy demand and the energy consumption by each factor were compared and analyzed. And it analyzed energy consumption by element of each house by ENERGY # program. As a result, first in the evaluation of the energy efficiency grade of buildings by the ECO2 program, the rating for primary energy requirement for the housing newly built by the standard design of rural house is expected to range from 2 to 4 with 189.3 to $238.7kWh/m^2.a$. Second, the energy loss of each part of standard design of rural housing occurs in the order of ventilation 39%, window 33%, outer wall 14%, roof 9%, bottom 5%, and energy loss through ventilation and window occurs more than 70%. Third, the most beneficial effects on the energy efficiency grade is obtained the lowest grade of all three types by 2 when the lowering of the window and door heat transmission rate and the lowering of the light density, and the heat exchange ventilation device is not installed. Fourth, in the standard design of rural housing, the energy demand is occupied by heating > hot water > lighting order, and the order of the weight is changed in order of heating > lighting > ventilation > hot water. Fifth, building energy efficiency assessment system needs to establish policy for fixing rural housing energy as a practical device to ensure energy performance and quality.

발전소 환경소음 예측 (Environmental Noise Prediction of Power Plants)

  • 조대승;유병호
    • 소음진동
    • /
    • 제7권4호
    • /
    • pp.621-629
    • /
    • 1997
  • For computer aided design and costruction of low noisy power plants, indoor and outdoor noise prediction program has been developed. The program utilizes the predefined data of noise sources and building materials and has the faculty to estimate the source level using the empirical formula in case of the measured data not being available. In the noise prediction, the mutual noise propagation between indoor and outdoor sites are considered. The outdoor noise source in the calculation of geometric divergence effects is modelled as the omni-directional finite line or planar source according to the source geometry and the receiving points. Outdoor noise prediction is carried out to consider the diffraction effect due to plant structures as well as the attenuation effect due to atmospheric absorption and soft ground. The results of indoor and outdoor noise prediction for a recently constructed diesel engine power plant show good agreement with the measured.

  • PDF

IEEE 802.15.4 비컨 가용 방식에 의한 실시간 음성 트래픽 성능 평가 (Performance Evaluation of Real-time Voice Traffic over IEEE 802.15.4 Beacon-enabled Mode)

  • 허윤강;김유진;허재두
    • 대한임베디드공학회논문지
    • /
    • 제2권1호
    • /
    • pp.43-52
    • /
    • 2007
  • IEEE 802.15.4 specification which defines low-rate wireless personal area network(LR-WPAN) has application to home or building automation, remote control and sensing, intelligent management, environmental monitoring, and so on. Recently, it has been considered as an alternative technology to provide multimedia services such as automation via voice recognition, wireless headset and wireless camera for surveillance. In order to evaluate capability of voice traffic on the IEEE 802.15.4 LR-WPAN, we supposed two scenarios, voice traffic only and coexistence of voice and sensing traffic. For both cases we examined delay and packet loss rate in case of with and without acknowledgement, and various beacon period varying with beacon and superframe order values. In LR-WPAN with voice devices only, total 5 voice devices could be applicable and in the other case, i.e., coexisted cases of voice and sensor devices, a voice device was able to coexist with about 60 sensor devices.

  • PDF

H종 주상용 몰드 변압기의 덕크구조에 따른 열해석 특성 (Surface Ageing Property of Polymer Insulator for Transmission line with Forest Fire Test)

  • 조한구;김광용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.111-111
    • /
    • 2010
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. In this paper, the temperature distribution and thermal stress analysis of H class 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

일반 환경에서 마스터-슬레이브 기반 전력선 통신 모뎀의 성능 시험 및 분석 (Performance Test and Analysis of Master-Slave Based PLC Modem in General Building)

  • 황민태;하현석;이재호
    • 한국멀티미디어학회논문지
    • /
    • 제8권5호
    • /
    • pp.660-669
    • /
    • 2005
  • 본 논문에서는 국내에서 개발된 마스터-슬레이브 기반의 10Mbps급 전력선 통신 모뎀을 전력선 통신 시범 서비스 대상의 일반 가정에 설치한 다음 전력선 통신의 네트워크 성능 및 멀티미디어 수용 능력을 측정하고 그 결과를 분석하였다. 본 연구를 위한 테스트베드는 하나의 마스터 모뎀과 3개의 슬레이브 모뎀으로 구성되며, 이들 간에 RFC 2544에서 규정한 처리율, 지연시간, 그리고 프레임 손실율을 측정하였으며, 아울러 RFC 2285에서 규정하고 있는 일대다 및 다대일의 처리율 시험을 실시하였다. 성능 시험 및 분석 결과 여러 노이즈 소스가 있는 일반 가정에서 전력선 통신모뎀의 성능은 대체적으로 단위 프레임의 크기가 클수록, 전송 속도가 느릴수록 좋은 성능을 나타냄을 알 수 있었다. 이러한 성능 분석 결과는 노이즈 소스가 통제된 환경에서의 성능 분석 결과와 비교하여 노이즈 소스가 실제 성능에 어떠한 영향을 미치는 지를 파악하는 용도로 사용될 수 있다.

  • PDF

전통창호 흡·차음 특성에 관한 실험적 연구 (An experimental study on the sound insulation and sound absorption characteristics of Korean traditional windows)

  • 이태강;김항;송국곤;김선우
    • KIEAE Journal
    • /
    • 제8권5호
    • /
    • pp.3-10
    • /
    • 2008
  • The Korean traditional architecture has developed by adapting to the natural environment, and has successfully created a comfortable indoor settings by using the surrounding natural resources. This is reflected in the building layout, space design and even materials. Our traditional wooden windows adjusting ambient temperature and humidity have both the functions of window and door, although they are clearly divided in the West. The opening and closing method of our traditional windows is similar and their dimensions are shown not to be standardized but diverse in terms of the characteristic of wooden furniture and that of components placed between columns. Thus this study aims to research the sound insulation and absorption performance of traditional windows to be varied with thickness, finishing method of window paper and thickness of air layer. Despite increase of the thickness of window paper, sound absorption was reduced, and the same result was shown when both sides of the structure were finished with thick window paper. The sound insulation performance of the windows could be evaluated to be inappropriate with $R_w$ 0 ~ $R_w$ 14.

광섬유를 이용한 자연채광시스템 적용 연구 (A Study on the Application of Sunlight System Using an Optical fiber)

  • 안승주;한상주;홍우식;최창호;이종혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.51.2-51.2
    • /
    • 2010
  • In recently, interests in the New & Renewable Energy are increasing because of exhaustion of fossil energy and limit of greenhouse gas emission all over the world. Furthermore, improvements in living standards and high-raise Buildings due to the industrial growth require a lot of sunlight in the interior space. Sunlight system gets the natural light into the indoor dark space. There are a lot of type of systems which are reflector type, duct type, optical fibers type and so on. And these systems consist of light-collection module, light-transporting module and light-emitting module. In this research, we installed optical fiber sunlight system in our head office building and tested the system's performance and efficiency. Optical fiber sunlight system is closely connected with hour of sunlight, due to the system have to chase the sun for the solar concentrating, and the system's light-collection and light- transporting efficiency is important factors in the system's performance. As a result of the test, system can be used about 5.66 hours on average in a day, and it has a about 3.21 times collection efficiency and 5.5% transmission loss.

  • PDF

전통창호의 차음 특성에 관한 연구 (A study on the Sound Insulation Characteristics of Korean Traditional Windows)

  • 김항;이태강;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1147-1150
    • /
    • 2007
  • Korean traditional houses have been developed in sympathy with natural environment and formed comfortable indoor condition by properly using surrounding natural resources including building layout, space construction and material. Or traditional wooden windows adjusting ambient temperature and humidity have both the functions of window and door, although they are clearly divided in the West. While window paper is attached from the outside in China and Japan, it is attached from the inside in Korea. The opening and closing mode of windows is similar and their dimensions are shown not to be standardized but diverse in terms of the characteristic of wooden furniture and that of components placed between columns. Thus this study is to look into the performance of band-lattice door of a typical traditional one by observing changes in sound insulation characteristics according to difference in thickness and finishing method of window paper and those in sound insulation characteristics with the changed thickness of air layer in traditional windows and doors.

  • PDF

Tunable compression of wind tunnel data

  • Possolo, Antonio;Kasperski, Michael;Simiu, Emil
    • Wind and Structures
    • /
    • 제12권6호
    • /
    • pp.505-517
    • /
    • 2009
  • Synchronous wind-induced pressures, measured in wind-tunnel tests on model buildings instrumented with hundreds of pressure taps, are an invaluable resource for designing safe buildings efficiently. They enable a much more detailed, accurate representation of the forces and moments that drive engineering design than conventional tables and graphs do. However, the very large volumes of data that such tests typically generate pose a challenge to their widespread use in practice. This paper explains how a wavelet representation for the time series of pressure measurements acquired at each tap can be used to compress the data drastically while preserving those features that are most influential for design, and also how it enables incremental data transmission, adaptable to the accuracy needs of each particular application. The loss incurred in such compression is tunable and known. Compression rates as high as 90% induce distortions that are statistically indistinguishable from the intrinsic variability of wind-tunnel testing, which we gauge based on an unusually large collection of replicated tests done under the same wind-tunnel conditions.

셀롤로오즈 흡음재의 음향적 특성 평가 (Evaluations of the Acoustics Characteristics of Cellulose Absorbers)

  • 연준오;김경우;양관섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.760-765
    • /
    • 2013
  • Eco-friendly material applied to building would be one of the materials which is must developed for global environmental conservation and reduction of carbon dioxide. For development of eco-friendly material, a cellulose sound-absorbing material has been developed with waste paper through adjustment of various mix proportions. The developed cellulose sound-absorbing material has been tested for its acoustic properties such as acoustic absorptivity and dynamic elastic modulus. The absorptivity was evaluated by developing six samples and using impedance tube and reverberation chamber. As a result of the evaluation, 0.64(NRC) was secured in absorptivity and $4.7MN/m^3$ was indicated in dynamic elastic modulus. Also, for practical use of developed sound-absorbing material as inner heartwood in drywall, comparison test of sound reduction index was performed with existing glass wool sound-absorbing material and constructed drywall of gybsum board. The results have shown 55dB(Rw) of sound reduction index in glass-wool wall and 46dB(Rw) in cellulose.

  • PDF