• Title/Summary/Keyword: building passage

Search Result 90, Processing Time 0.026 seconds

A Study on the Minimum Distance between Landscape Trees and Apartment Buildings (수목생육 조건을 고려한 조경수목과 아파트 건물의 최소 이격거리에 관한 연구)

  • Jang, Ha-Kyung;Ahn, Geun-Young;Lee, Eun-Heui
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.1 s.120
    • /
    • pp.1-8
    • /
    • 2007
  • The purpose of this study is to suggest the minimum distance needed between landscape trees and apartment buildings. in order for the trees to grow soundly and maintain constant growth. Therefore, this study investigated and analyzed the present conditions of the green-spaces contiguous to apartment buildings and the trees inside the apartment complex. The following general problems were identified : (1) the tree growth conditions, (2) the planting intervals, and (3) the planting methods in the apartment complexes. The method of this study was to survey areas, measure the trees and analyze the results. Ten apartment complexes located in Seoul were randomly selected for this study. To analyze the greens contiguous to the building of each apartment complex, the greens were divided into three types, including the front greens, the side greens, and the rear greens. The study surveyed the width of all contiguous greens and the distance from trees to my given building. Four representative sites were specifically investigated to measure the crown widths, heights, and diameters of the trees. These investigations were carried out over 3 months from August to December 2006. According to the results of the study, it was found that the greens are narrower in width and the more closer to a building. The study identified a correlation between the tree and the passage of time after the completion of construction of an apartment complex, showing that the malformation of the trees worsened as time passed. As a result of measuring the right crown and left crown width with the tree trunk as the center, a broad difference was found between coniform trees and trees that tend to branch out more. For example, the ratio of the width of the Acer palmatum is 1:6. However, the ratio of the Metasequoia glyptostroboide is 1:1.7. Based on the overall analysis, it was concluded that the maintained minimum width must be greater than one meter over the green space according to the 'Landscape Standard 2000'. However, that is only applicable to cases such as apartment buildings that present no obstacles. In conclusion having greens placed within one meter of width to a building is not an appropriate environment for the healthy growth of trees. To create sound green spaces, sustainable, long-term growth rate and size should be considered. It is necessary to prepare new standards for the computation of planting trees and the measurement of square landscapes. Wall greenery and shrubberies could be an alternative in the case of a narrow-width green space.

The study on the height standard and the slenderness ratio according to location types of Mixed-use Residential Tall buildings (초고층 주상복합건축물 입지유형에 따른 높이기준 및 세장비 제안에 관한 연구)

  • Sung, Lee-Yong;Kim, Yun-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2779-2788
    • /
    • 2012
  • The housing market is now difficult because of excess of the increase rate of housing and long-term recession but high-rise mixed-use buildings can mix residential facilities with various demand facilities focusing and they have the advantages to secure open space and excellent view by high-rise apartment. But there are problems by hindrance of skyline formation and height of buildings. Therefore, the purpose of this study is to suggest the height standard and the slenderness ratio to location types of Mixed-use Residential Tall buildings. For the method of the study, term arrangement through literature search and the precedent research survey were first done, the level of urban design and the details related to the height of buildings were done as the case research focusing on the 16 cases in Seoul. The following results were drawn by suggesting the height standard and the slenderness ratio by location type based on them. First, the height of mixed-use building by location type in the level of urban design gets higher starting from the secondary center of the city and can be suggested as from less than 150m to more than 200m. Second, the slenderness ratio shall be planned as more than 1:3 because the area of the ground level of mixed-use building is large unlike Mixed-use Residential Tall buildings and visual passage shall be placed so that unity of openness and group formation will be planned. Third, for the height related to Mixed-use Residential Tall buildings, amendment of the special architectural district system and the special law related to super high-rise buildings shall be enacted.

Analysis of Ambivalence Differences among Groups for Temporary Firefighting Facilities of Workers at Construction Sites (공사현장 근로자의 임시소방시설에 대한 집단 간 Ambivalence 차이분석)

  • Moon, Pil-Jae;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.765-778
    • /
    • 2021
  • The purpose of this study is to prevent fire accidents in advance by deriving prior knowledge among groups about temporary fire-fighting facilities of workers at construction sites and devising appropriate improvement measures. The findings are as follows.First, in the case of fire extinguishers, statistical attention was paid to the contractor, supervisor, partner worker and fire extinguisher manager between designations. 87% of fire managers and 70% of facility supervisors said fire extinguisher management managers needed to be designated for each type of construction, which requires designation of fire extinguisher management managers, frequently checking and relocating. Second, in the case of simple fire extinguishing facilities, statistical attention was paid to the application of penalties for unauthorized use of fire extinguishing facilities with construction companies, supervisors, and business partners.Third, in the case of emergency alarm measures, statistical attention was paid to the application of emergency alarm sound to temporary broadcasting facilities with construction works, supervisors, and business partners.Fourth, in the case of induction, statistical attention was paid to the application of connection between construction works, supervisors, and partner workers, such as passage guidance, emergency lighting, etc.It was found that 65% of construction workers and 55% of electrical workers had different applications such as aisle guidance and emergency lighting for each type of business partner. In order to resolve blind spots such as evacuation zone guidance due to the structure of the building, it is necessary to easily distinguish the direction of the entrance door from a long distance by applying it in conjunction with passage guidance lights and emergency lighting.

An analysis study for reasonable installation of tunnel fire safety facility (터널 방재설비의 합리적 설치를 위한 분석적 연구)

  • Park, Jin-Ouk;Yoo, Yong-Ho;Park, Byoung-Jik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.243-248
    • /
    • 2015
  • Domestic road and railroad construction have been increasingly growing and for reasons of mitigating traffic congestion, urban plan and refurbishment project, deeper and longer tunnels have been built. The event of fire is the most fatal accident in a tunnel, and it can be very disastrous with a high possibility. In this study, QRA (Quantitative Risk Analysis) which is one of quantitative risk analysis approaches was applied to tunnel fire safety design and the evaluation of QRA cases and the cost comparison of QRA methods were carried out. In addition analysis of risk reduction effect of tunnel fire safety system was conducted using AHP (Analytic Hierarchy Process) and the priority of major factors that could mitigate the risk in tunnel fire was presented. As a result, significant cost reduction effect could be obtained by incorporating QRA and it is expected to design fire safety system rationally. The priority of fire safety system based on risk mitigation effect by fire safety system considering the cost is in order of water pipe, emergency lighting, evacuation passage and smoke control system.

Rheological Evaluation of Blast Furnace Slag Cement Paster over Setting Time (고로슬래그 혼합 시멘트 페이스트의 응결시간 경과에 따른 레올로지 특성)

  • Cho, Bong-Suk;Ahn, Jae-Cheol;Park, Dong-Cheon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.505-512
    • /
    • 2016
  • Even though high performance concrete was developed according to the trend of bigger and higher of reinforced concrete building, the rheological evaluations such as viscosity, yield stress are not enough to use as input data to accomplish the numerical analysis for the construction design. So there are many problems in the harden concrete such as poor compaction, rock pocket and crack, etc. in the field. In this study, consistency curves were measured by the viscometer as hydration reaction time passed. At the same time the slump flow test and Vicat setting test were carried out for comparing with the results of rheological properties. The fluidity of the W/B 30% decreased as the increase of replacement ratio of blast furnace slag. But in case of W/B 40%, the replacement ration did not significantly influenced to the slump flow value with the passage of hydration time. By the replacement of blast furnace slag to cement, initial setting was delayed and the time gap between initial and final setting became shorten. Through the regression analysis using Bingham model, there are a sudden changes of viscosity and yield stress around initial setting in case of low W/B 30%. The increase of workability by the change of free water in cement paste was offset by the coating effect of impermeable layer in case of W/B 40%.

Design of Standard Submission Format for Underground Structures : An Automated Update of the UnderSpace Integrated Map (지하공간통합지도 자동갱신을 위한 지하구조물 제출 표준 설계)

  • Park, Dong Hyun;Jang, Yong Gu;Ryu, Ji Song
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.469-476
    • /
    • 2021
  • The framework plan for the development of an integrated underground space map was established of preventing ground subsidence. The mapping process is expected to be completed to the level of nationwide municipal government standards by end of this year. To facilitate the utilization of the integrated underground space map, paper-based drawings for specialized organizations in underground safety impact assessment have been provided since September 2018, and services for local government officials have been provided in the underground information utilization system since May 2019. However, the map is utilized based on the information at the time of the initial development of the map, without any updates, thereby resulting in a lack of accuracy and latest information. This has led to a decrease in the utilization and reliability of the information. Therefore, in this study, for the underground structures(subway, underground shopping mall, underground passage, underground roadway, underground parking lot, utility tunnel), which are the key components of the integrated underground space map, a standard format for the submission of completed drawings is designed in accordance with Article 42 (2) of the Special Act on Underground Safety Management, which aims at laying the foundation for establishing the updated system of the integrated underground space map. In addition, through the verification of the automatically updated underground structure data based on the standard format, the reliability of the data can be assured. This format is expected to contribute to the improved utilization of the integrated underground space map in the future.

Revitalization of Elementary School Plots, as Small Public Parks -A Case Study of School Subject Parks in Seoul - (소공원으로서 초등학교부지의 활용방안 - 서울시 학교공원화사업 대상지를 중심으로 -)

  • Nam, Mi-A;Lee, Eun-Heui
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.1
    • /
    • pp.14-30
    • /
    • 2006
  • It is difficult to secure public lots in the downtown area, school lots can be made the best use of important source to increase the area of green land in the city. The tree-planting campaign for schools has been in force since 1999 by the city of Seoul and at present; it is currently established as the plan of school parks. Thereupon, the purpose of this study is to present some ways to revitalize elementary schools to be used as vest pocket parks through the research of elementary schools, which are subject to the plan of school parks in Seoul. The results of this study are as below : The subjects to revitalize school parks as vest pocket parks are as follows. First, the land has to be utilized for security of space. Second, in addition to the front and back gate, another passage to the park has to be set up for easy access. Third, the fence has to be formed as a hedge used outside the park. Fourth, selecting plants, species of trees suitable for the landscape of school and taking into consideration the aspect of ecology. Finally, it is urgent to enact socially and economically proper standard of law by the new standards of area for school landscape considering not only the building law and regulations of general landscape, but also specific characteristics of school landscape.

A Study on the Form-Element of Buildings Affecting in Street Spaces (가로공간 이미지에 영향을 미치는 가로변건축물 형태구성요소에 관한 연구)

  • Choi, Im-Joo;Jo, Hyun-Duk
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.13 no.1
    • /
    • pp.16-27
    • /
    • 2010
  • A street, as a linear factor constituting the city, is an axis of urban development. The substantial function of the street is the traffic space for the passage but now it plays the important role of the place of community where contains various activities such as meeting between people and people, rest, entertainment etc. A street is basically the 3 dimensional space consisted of the sidewalk, roadway and the roadside structures surrounding the street. In this case, the roadside structures are the physical composition factors for the street space and the facade of the roadside structures acts as important variables to form the image of street space. Thus, this study is to provide the basic data to be applied in the future urban street landscape plan by extracting the superior factors in visual and perceptional aspects which affect the image of street view from the shape composition factors which constitute the facade of the roadside structures, and by searching and analyzing the satisfaction degree and preference of each factors.

A Study on Area Planning of Air Conditioning Room for Hospital Design Focused on System (체계중심병원설계를 위한 공조실 면적 계획에 관한 연구)

  • Kim, Eun Seok;Yang, Nae Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.4
    • /
    • pp.27-35
    • /
    • 2019
  • Purpose: As the improvement in quality of medical environment and the spatial consideration for the prevention of infection in the hospital have become increasingly important in the recent years, specific and practical planning for air conditioning room's area has become a major issue accordingly. However, the air conditioning room tends to be discussed focusing on technical factors such as air conditioning systems that are irrelevant to building plans, while discussions of most departments related to the medical functions have actively taken placed. Therefore, this study aims to investigate the factors influencing the planning for the air conditioning room area, and through subsequent analysis of the area of the air conditioning room, to propose a way to improve effective planning for the air conditioning room area. Methods: This study examines the case hospitals that fall into two types: each floor supply system and concentrated supply system, and compares and analyzes the air conditioning room area-related factors and the characteristics of changes in the interior of air conditioning room before and after remodeling through air conditioning floor plan of those case hospitals. Results: The air conditioning room can be classified into the net area of the functional space such as duct passages, and the public area such as aisle space, and of those the public area is an important factor in calculating the area of the air conditioning room. The public area of the air-conditioning room should not be planned considering only the spaces for mobile passage or maintenance activities, but should be planned taking into account internal changes such as expansion and replacement of equipment in the future from the beginning. Implications: When planning a medical facility, it is used as basic data for the planning of the air conditioning room area, which is a significant fixed factor in the initial setting.

Real time indoor positioning system using IEEE 802.15.4a and sensors (IEEE 802.15.4a와 센서를 이용한 실시간 실내위치인식 시스템)

  • Cho, Hyun-Jong;Hwang, Kwang-Il;Noh, Duck-Soo;Seo, Dong-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.850-856
    • /
    • 2012
  • Bilateration using two fixed nodes has been used in the field of the real time indoor location system in the narrow space such as building or ship passage. However, as the distance between the fixed nodes increases or any obstructions exist in their zone, it is difficult to detect the location of mobile node(user) due to the degradation of its reception ratio. In order to compensate for these problems, this paper presents, based on IEEE 802.15.4a chirp signal, a new real time indoor location system using stride measurement algorithm which can calculate the location through sensors attached to user. The proposed system consists of an ultrasonic sensor to measure the leg length, a geomagnetic sensor to recognize the user's orientation, and an inertial sensor to obtain the angle between the legs. The experimental results are shown that the proposed system has twice or more accurate output compared with conventional indoor location method in the section which is partially out of communication reachability.