• 제목/요약/키워드: building layout

검색결과 340건 처리시간 0.028초

드론영상 기반 침수 모니터링 및 조립식 빗물 침투 저류블록 구조를 활용한 상습 침수지역 대응 방재기술 (Disaster Prevention Technology in Response to Flooded Areas Using Drone Image-Based Inundation Monitoring and Prefabricated Rainwater Penetration Storage Block Structure)

  • 최희용;최형길;류정림;김원창;이태규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.411-412
    • /
    • 2023
  • The purpose of this research and development is to develop a structure module that improves the efficiency and constructability of the layout structure as well as the design development of rainwater permeable storage tank blocks using inorganic binders and aggregates with the aim of reducing greenhouse gas (CO2) with eco-friendly materials. In addition, for the efficient response to flooding of the developed permeable storage structure, we present a technical solution for combining drone mapping technology and flood monitoring technology that can analyze topographical factors in detail.

  • PDF

BIM 기반 형상코드를 이용한 기둥 철근길이 자동 산정 기초 연구 (A Basic Study of Automatic Rebar Length Estimate Algorithm of Columns by Using BIM-Based Shape Codes Built in Revit)

  • 오진혁;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.21-22
    • /
    • 2023
  • In reinforced concrete constructions, reinforcing bar generates more CO2 per unit weight than other construction materials. In particular, cutting and bending rebar is the main source of rebar waste in the construction industry. Rebar-cutting waste is inevitable during the construction of a reinforced concrete structure since the rebar is not manufactured as designed. Large amounts of waste can be avoided by utilizing optimal cutting patterns and schedules. This research provides a fundamental analysis of the automatic calculation of column rebar length using BIM-based shape codes to minimize cutting waste to near zero. By employing this approach in practice, it is possible to minimize the rate of rebar-cutting waste, reduce costs, shorten construction duration, and reduce CO2 emissions. In addition, the development of this research will serve as a clue for the development of BIM-based rebar layout automation algorithms.

  • PDF

김수근의 자유센터에 대한 비평적 독해 (A Critical Reading of Freedom Center Apacle by Architect Kim Su Geun)

  • 강혁
    • 건축역사연구
    • /
    • 제21권1호
    • /
    • pp.135-154
    • /
    • 2012
  • The goal of this paper is to analyze the Freedom Center Apacle in Seoul designed by Kin Soo Geun who was a leading architect in Korean Modern architecture. Freedom Center was built in 1963, that was the largest monumental building to support military regime during cold war period in Korea. This paper deals with historical background of construction of Freedom Center and its characteristics compared to similar monumental buildings, especially Corbusier's Chandigar and Kenzo Tange's Hiroshima Peace Center. The Monumentality in Freedom Center came from the reference to these two buildings and its site plan. This paper tried to show how similar the layout of buildings between the Freedom Center and Peace Center. The origin of the sublime aura in Tange's linear layout of Peace Center is from Japanese Famous Shrine(Jinku). Kim translated it to serve the ideological purpose to protect from socialist regime in the name of freedom. Its over-scaled roof and weak contents showed Freedom center was a kind of theaterical setting belong to formalist building. But in spite of its symbolic and representational gesture its also had a architectonic physical quality to make it a monument. The change and duration in time testified the autonomous power of architecture in Freedom Center. Freedom Center was also important for using the exposed concrete and its superior finish. It was influenced not from western way of Benton Brut which was usually called New Brutalism but Japanese way of treating expose concrete. In spite of its limits Freedom center achieved new trend and sensibility in Korean Modern Architecture.

충북의 2010년 이후 신설된 학교 분석을 통한 저층부 배치 시설 및 공간 특성 연구 (A Study on the Facilities Layout of Lower Floor and Space Characteristics Through Analysis of Newly Established Schools in Chungbuk since 2010)

  • 강혜진;정진주
    • 교육시설 논문지
    • /
    • 제22권2호
    • /
    • pp.3-13
    • /
    • 2015
  • The policy of the Ministry of education through the social awareness and issues are being changed. Accordingly, in response to the school building which also has to be changed. This study is Low-floor(1~2 floor) for high accessibility, important management and a lot of locomotion. This study is analysis by floor of newly established schools in Chungbuk. Facility and space on the possible low-floor situated are classified administrative zone, health zone, student support + local exchange zone, STEAM(creativity, personality) supporting zone. The administrative area includes administration office, principal's office and board rooms. The administrative zone is located against schoolyard. Because it is possible visual control of schoolyard. also it controls visitor access so it is placed near main entrance. Health zone is located near a special class, counseling center and wee class for emergency situation. and is located near schoolyard for visual control. Student support + local exchange area includes library and computer lab, audio-visual room, auditorium or gymnasium. It put more emphasis resident welfare, culture and education. So it opens for local residents. It is located center of few stories or near entrance. STEAM(creativity, personality) supports science lab, art room, family room. It is possible such a theory class, experience class and indoor and outdoor class. It is located few floors. This study is used as a reference for school building projects planing.

복합플랜트 지하 건설을 위한 파이프랙 모듈 공법 안정 해석 (Stability Analysis of Pipe Rack Module for Underground Complex Plants Construction)

  • 김세원;이상준;김영석
    • 한국지반신소재학회논문집
    • /
    • 제20권4호
    • /
    • pp.113-124
    • /
    • 2021
  • 도시화 및 경제성장에 따라 기존 매립지 등 기피 시설로 인식되어 있는 지상 환경기초시설 및 에너지생산 시설의 지하화가 중요한 사회적 이슈로 대두되고 있다. 대규모 플랜트 시설을 지하에 안전하게 건설하기 위해서는 제한적인 공간 레이아웃의 활용성을 높이고, 불필요한 기둥을 최소화해야 한다. 본 논문에서는 플랜트 시설을 지하화 할 경우 발생하는 작업의 제약여건, 조립 및 철거, 공정 계통의 연계성, 유지 보수 등의 문제를 해결하기 위하여 플랜트 모듈화 공법(파이프랙)에 대해 검토하였다. 복합플랜트의 지하 고집적 배치, 공간 레이아웃 활용성 향상 및 구조물 안정성 확보를 위해 다양한 하중조건(지진하중, 장치하중, 토압하중 등)을 적용한 플랜트 모듈 해석을 수행하였다. 또한, 작용하중과 부재가 견딜 수 있는 설계강도비 값을 검토하고 모듈 형상에 따른 안정성을 고려한 파이프랙 소재를 추출하였다. 다양한 경계조건에서의 해석 결과를 바탕으로 지하복합플랜트 건설 시 필요한 기본모듈의 최소 설치 간격 및 모듈 배치(안)에 관한 시사점을 도출하였다.

빛에 의한 치료적 효과 기반의 한국형 치매요양시설의 자연채광 계획 요소에 관한 고찰 (Daylighting Design Factors for Korean Dementia Nursing Homes Based on the Therapeutic Effects of Light)

  • 지수인
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제28권4호
    • /
    • pp.71-87
    • /
    • 2022
  • Purpose: This study examines the daylighting design factors of Korean dementia nursing homes, in order to realize a therapeutic environment based on the therapeutic effect of light in the rapidly aging trend with an huge increase in the population of dementia in Korea. Methods: Through literature reviews, this study aims to theoretically examine the therapeutic light environment for the elderly with dementia, derive daylighting design factors of Korean dementia nursing homes, and analyze their detailed design factors. Results: The result of this study can be summarized into two points. The first one is that the daylighting design factors reflected in dementia nursing homes are derived into six factors: building layout, windows, glazing, shading devices, spaces, and interior finishings that determine the availability of daylight. The second one is that the detailed daylighting design factors are shown as primary and secondary detailed design factors, and the main values to be considered when applying these factors into dementia nursing homes are analyzed as maximizing daylight availability, optimization of the possibility of therapeutic view, and anti-glare. Implications: The daylighting design factors will contribute to maximizing the availability of daylight, optimizing the possibility of view, and minimizing the glare in the living spaces of dementia nursing homes in Korea.

양면형 BIPV 시스템의 커튼월 적용에 따른 온도 및 발전특성 분석 (Analysis of Temperature and Power Generation Characteristics of Bifacial BIPV System Applied into Curtain Wall)

  • 강준구;김용재;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.57-66
    • /
    • 2015
  • BIPV system not only produces electricity at building, but also acts as a material for building envelope. Thus, it can increase the economical efficiency of PV system by saving the cost for building materials. Bifacial solar cell can convert solar energy to electrical energy from both sides of the cell. In addition, it is designed as 3 busbar layout which is the same with ordinary mono-facial solar cells. Therefore, many of the module manufacturers can easily use the bifacial solar cells without changing their manufacturing equipments. Moreover, bifacial PV system has much potential in building application by utilizing glass-to-glass structure of PV module. However, the electrical generation of the bifacial PV module depends on the characteristics of the building surface which faces the module, as well as outdoor environment. Therefore, in order to apply the bifacial PV module to building envelope as BIPV system, its power generation characteristics are carefully evaluated. For this purpose this study focused on the electrical performance of the bifacial BIPV system through the comparative outdoor experiments. As a result, the power generation performance of the bifacial BIPV system was improved by up to 21% compared to that of the monofacial BIPV system. Therefore, it is claimed that the bifacial BIPV system can replace the conventional BIPV system to improve the PV power generation in buildings.

대학도서관의 에너지 절감에 관한 기초적 연구 - 세종시에 위치한 H 대학 건물을 중심으로 - (A Basic Study on Energy Saving of University Library - About 'H' University Building located in Sejong City -)

  • 노지웅
    • KIEAE Journal
    • /
    • 제13권4호
    • /
    • pp.69-74
    • /
    • 2013
  • It is difficult to apply a design standard uniformly to university buildings because various education courses are conducted. However, a design guideline for saving energy is necessary in order to prepare for low-energy days. A library in any university is one of the buildings that a lot of people use and most of the energy is spent. Therefore, the investigation on the energy savings of library facilities is very important and urgent. This study finally presents the design guideline of those facilities for low-energy. In this paper, the trend of space layout, utilization schedule and performance of materials are investigated, and the impact on energy savings and effective energy saving strategies are analyzed and illustrated by energy simulation. As a result of energy analysis from the case of 'H' university, it is confirmed that the utilization schedule effects mostly to energy consumption and the layout and orientation of the rooms in the library are the major parameters. Among the investigated saving strategies, green roofs are found as the most effective part for heating energy savings, and outdoor air cooling is known as the most effective method for cooling energy savings.

가변추진기 추진축계시스템의 설계 (제 I 보 : 외형설계 ) (Design of Propulsion Shafting System for Controllable Pitch Propeller (I : Latout Design with Sizing))

  • 김기인;전효중;박명규;김정렬
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.129-134
    • /
    • 2002
  • This study is focused on the layout design with sizing for the main propulsion shafting with controllable pitch propeller system. For appropriate design and successful manufacturing of controllable pitch Propeller system, it is based on specifications to be required from the customer as well as the stresses calculation and analysis of main propulsion system for hollow shafting. And it must be performed according to the U.S military specifications MIL-STD-2189(SH) with drawing of NAVSHIPS 803-2145807, and also the stress analysis by applying safety factor. The results are as follows : 1. For the main propulsion system with controllable pitch propeller, it is designed the following items propeller diameter, hub diameter, dimensions of oil distribution or actuating unit based on shaft mounting type, diameters of propeller and intermediate shaft, dimension of split muff coupling, coupling flange thickness and of coupling bolt diameter. 2. As the results, we can get complete our own design ability for the main propulsion shafting with controllable pitch propeller system with critical data which are necessary to establish shafting arrangement from the ship building companies.

  • PDF

사무소 건물의 화재하중 분포 (A Survey of Fuel Loads in Office Buildings)

  • 김운형
    • 한국화재소방학회논문지
    • /
    • 제11권1호
    • /
    • pp.37-45
    • /
    • 1997
  • 본 연구에서는 국내 10개 설계 사무소 건물을 대상으로 화재하중 분석방법과 현재의 화재하중 분포 를 제시하였다. 조사범위는 건물 완공 후 거주자가 반입한 이동성 물품(이하 이동하중)으로 제한하였 다. 조사결과는 평면배치, 바닥면적, 사용인원 및 가연물의 특성에 따른 이동하중과의 관련성과 함께 미국의 조사 결과와 비교 분석하였다. 현재 국내 사무소 건물의 이동하중은 95% 신뢰도 기준으로 36.13kg/$m^2$ 에서 52.41kg/$m^2$ 사이에 분포하며 평균 화재하중은 44.27kg/$m^2$ 으로 나타났다. 한 미간의 분포는 미국이 평균 66. 84kg 1m2로 한국의 44.27kg/$m^2$ 에 비해 상당히 높게 나타났다. 본 연구결과는 향후 건불의 화재위험도 분류 및 화재 실험시 가연물량 기준에 적용되며 내화설계의 기준 결정을 위한 기초자료로 활용될 것으로 기대된다.

  • PDF