A Study on Indoor Environmental Quality Evaluation in Apartment Buildings - Focus on Apartment Buildings in USA - (공동주택에서의 실내환경의 질 평가에 관한 연구 - 미국 공동주택 사례를 중심으로 -)

  • Yoon, Sung-Hoon
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.4
    • /
    • pp.79-87
    • /
    • 2009
  • Residential Buildings should provide high-quality, comfortable environments to support the activities of their occupants. The indoor environment of residential buildings, which includes thermal, lighting, acoustic, and indoor air quality, has a significant impact on health and quality of life. The comfortable living environment in residential buildings result from appropriately combining these environmental quality factors, and the performance of building systems must be compatible with the activities of the occupants. The objective of this research is to investigate and analyze the relationship between physical environmental conditions and occupant responses for improving environmental quality (EQ) in apartment buildings with four different building orientations (i.e. E, W, S, N) in two different seasons (i.e. winter and summer). The occupant survey was conducted in actual apartment buildings. The Physical environmental conditions in apartment buildings differed substantially depending on space, outdoor weather conditions and building orientations. Each space within the same apartment building had different environmental conditions. Combinations of unbalanced physical environmental conditions in apartment building decrease occupants' satisfactions and their perceptions of overall residential quality. Occupants' satisfaction and their responses to physical characteristics of their residential environment is related to thermal, lighting, acoustic, and indoor air conditions in their buildings. The result from this research will help designers and researchers to identify problems and develop solutions for improving environmental quality from the occupants' point of view.

A Survey on Operating State of ISWTP according to Building Use Type (건물용도에 따른 개별오수처리시설의 운영실태에 관한 연구)

  • Gwon, Eun-Mi;Kim, Jong-Seok;Chung, Wook-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.3
    • /
    • pp.337-341
    • /
    • 2005
  • It is difficult to use average sewage water quality as a design parameter for the individual sewage wastewater treatment plant(ISWTP), because sewage water quality is very various according to the building use type. So, in this study, we estimated daily, seasonal and weekly trend of sewage water quality and flow rate in various kind of building to comprehend operating state of ISWTP. The sewage water quality and flow rate were higher in the business building than household building. The seasonal difference of the water quality was not detected but that of flow rate was high. The flow rate of the sewage in the business building was higher in summer than in other seasons and in weekend than in weekday. The treatment efficiency of IWSTP was about $70{\sim}80%$ with BOD, $40{\sim}50%$ with TN and TP, which was very low. The unit loads of the individual house were 36.05 gpcd with BOD, 37.91 gpcd with SS, 23.91 gpcd with T-N, and 7.90 gpcd with T-P respectively, and those values were higher than other studies. It is because, as distinct from other studies, sewage water quality was monitored at the inlet point of the IWSTP in this study. We can use this results as an one of basic parameters for the design of IWSTP.

An Analysis of Wind Field around the Air Quality Monitoring Station in the Urban Area by Using the Envi-met Model (Envi-met 모델을 이용한 도심지역 대기오염측정망 주변의 바람장 분석)

  • Kim, Min-Kyoung;Lee, Hwa Woon;Dou, Woo-Gon;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.18 no.9
    • /
    • pp.941-952
    • /
    • 2009
  • The urban microscale wind field around the air quality monitoring station was investigated in order to check how a building complex influences it. For this study as the high density areas Jwa-dong and Yeonsan-dong monitoring sites in Busan were chosen. As the direction of inflow which is perpendicular to the building of the monitoring station was expected to cause the considerable variation of the wind field, that direction was selected. The model Envi-met was used as the diagnostic numerical model for this study. It is suitable for this investigation because Envi-met has the microscale resolution. After simulating it, on the leeward side around a building complex the decrease of flow velocity and some of vortexes or circulation area were discovered. In addition, on the edge of the top at the building and at the back of the building the upward flow was developed. If the sampling hole of monitoring site were located in this upward flow, it would be under the influence of upward flow from the near street.

The Indoor Environmental Quality Improving and Energy Saving Potential of Phase-Change Material Integrated Facades for High-Rise Office Buildings in Shanghai

  • Jin, Qian
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.2
    • /
    • pp.197-205
    • /
    • 2017
  • The conflict between indoor environmental quality and energy consumption has become an unneglectable problem for highrise office buildings, where occupants' productivity is highly affected by their working environment. An effective Façade, therefore, should play the role of an active building skin by adapting to the ever-changing external environment and internal requirements. This paper explores the energy-saving and indoor environment-improving potential of a phase-change material (PCM) integrated Façade. Building performance simulations, combined with parametric study and sensitivity analysis, are adopted in this research. The result quantifies the potential of a PCM-integrated Façade with different configurations and PCM properties, taking as an example a south-oriented typical office room in Shanghai. It is found that a melting temperature of around $22^{\circ}C$ for the PCM layer is optimal. Compared to a conventional Façade, a PCM-integrated Façade effectively reduces total energy use, peak heating/cooling load, and operative temperature fluctuation during the periods of May-July and November-December.

The Work Scope of Remodelling for the Intelligent Office Building (기존 사무소건축의 IB화를 위한 리모델링 작업범위)

  • Park, Keun-Joon;Koo, Soo-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.1
    • /
    • pp.75-83
    • /
    • 2004
  • The IB is normally defined in terms of BA, OA, security system, information processing and telecommunications services However, the buildings being already in existence are deficient in two areas. One of these areas is building envelope and plan. The other area is mechanical, electrical and structural systems which do not provide the environmental quality required by IB. Existing technology and design knowledge are available to address these deficiencies. Especially, the office buildings being already in existence must meet IB requirement in order to achieve desirable office environment. They are a building envelope, moisture control, properly-located windows, shafts for duct, telephone and electric closets and acoustical environments. In this paper, a new approach to construct the work scope of remodelling the office building being already existence is described by contrasting the building performance criteria of IB. It concludes by speculating on the consequences of extrapolating the results of study to remodelling the office building being already existence.

Sick House/Building Syndrome in JAPAN -Current Status and Practical Research on Indoor Air Quality-

  • Sekine Yoshika
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.3
    • /
    • pp.207-214
    • /
    • 2005
  • Many Japanese today are suffering from health disorders related to their living environment, such as allergies and hypersensitivity to chemical substances. The Sick House/Building Syndrome has been a serious problem since 1996, due to low level exposure to hazardous chemicals such as formaldehyde and volatile organic compounds (VOCs) emitted in airtight houses. This paper aims to show current status of the syndrome in Japan and practical researches to promote prevention of, and improvement to indoor air pollution due to chemicals.

A Study on the Comparative Analysis and Improvement of Indoor Environmental Factor in Green Building Rating Systems (국내외 친환경건축물 인증제도 실내 환경 관련 부문 비교분석 및 개선안 연구)

  • Joh Hahn
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.21-28
    • /
    • 2006
  • To promote environmentally responsible architectural practice, many nations have established their own green building rating system. Among other criteria, recently the indoor environmental quality section has been paid great attention due to Sick Building Syndrome, as this believed to caused by polluted indoor environment. In this context, indoor environmental quality is one of very important sections of each green building rating system and closely related to the very happiness of building users. The goal of this research is to compare and analyze the indoor environmental sections of three green building rating systems, GBCC, LEED v2.1, and BREEAM Office 2005, and find a direction for the improvement of GBCC. First, the three rating systems are analyzed in general to compare the importance of indoor environmental factors in each system. Second, the indoor environmental factors are reclassified within related sub-categories for the comparable analysis. Finally, based upon the comparable analysis, directions for the improvement of GBCC are as follows: 1. GBCC's h4r Environment Section needs to clarify its VOCs criteria based upon types of finish materials. 2. Sound Environment Section's noise control criteria needs to be revised based upon types of building usages and application method. 3. An indoor lighting related section needs to be included in GBCC, as even though light is the one of the most important factors in indoor environment, it has not been included in GBCC yet. 4. The sub-section of Confortable Indoor Environment Section related to the resting space and the universal accessibility are not in accord with the goal of green building rating system. These items need to be dealt within general building codes. 5. The rating evaluation structure and process need to be streamlined.

A Basic Study of the Development of Indoor Environment Assessment Items for Eco-Friendly Indoor Environment of Hospital (의료시설의 친환경적 실내환경 조성을 위한 국내 친환경건축물 인증기준 개발에 관한 기초연구)

  • Lim, Tae-Sub
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.4
    • /
    • pp.47-53
    • /
    • 2007
  • As more serious environmental problems of buildings, many researchers have recognized the importance of preserving the environment where we live as well as a necessity of developing architecture with eco-environmentally. As a result, our country and some advanced countries have tried to solve these problems in that developed green building assessment tools for estimating environmental performance of buildings. Among many kinds of buildings, hospital which have been relation with human beings has been laking in basic raw materials of researching hospital's environment. Especially, there are few materials about indoor environment of hospital. So, the facilities of patients not only have to depend on the quality of natural environment but be also taken into account of patients. The purpose of this study is to prepare the basic data to develop the items of indoor environmental assessment for hospital to improve the quality of hospital's indoor environment. To come to a conclusion, we used a method of comparing domestic green building certification criteria, LEED v.2.2 and GBTool 2005. Then, we analyzed them for the case studies. Consequently, we could grasp basic data to assist in effecting domestic green building certification criteria for hopital. Furthermore, we have made a progressive research about setting grades of it.

Comprehensive Field Measurement of Indoor Air and Thermal Quality in Naturally Ventilated Office Building with Double-Skin Façade

  • Ito, Kazuhide;Shiraishi, Yasuyuki
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.4
    • /
    • pp.293-314
    • /
    • 2013
  • Double-Skin Façade (DSF), which is a kind of passive indoor environmental control technique, is effective way to control environmental loads while maintaining the transparency especially in perimeter zone and hence the adoption example of DSF keep increasing recently. The objective of this study was to perform a field survey of air quality environment with natural ventilation through DSF and thermal environment within office building with six stories during a mild climate period in Japan. Moreover, to understand the comprehensive environmental performance of the target building, questionnaire survey was conducted to subjectively evaluate the productivity and satisfaction with the environmental factors in office space. In this field measurement, there was a positive correlation between the DSF internal ventilation flow and the amount of solar radiation on the DSF normal surface; the primary driving force for ventilation in the DSF was considered to be the buoyancy force caused by solar radiation. The results of questionnaire survey with regard to productivity level indicated the need for improvement in the thermal (temperature) and spatial environment (room size and furniture placement).

A Proposal of Planning Direction of Eco-Friendly Multi-Use Housing and Commercial Complex (주상복합건물의 환경친화적 계획방향에 관한 기초 연구)

  • Lee, Eun Jung;Park, Myung Kyug;Park, Young Ki
    • KIEAE Journal
    • /
    • v.6 no.1
    • /
    • pp.39-46
    • /
    • 2006
  • Multi-use housing and commercial buildings have been emerged according to social and economic changes of CBD in Seoul Metropolitan Areas. The purpose of this study is to clarify the characteristics of the multi-use building, to analyze the problems on the base of survey and to suggest the solutions for architectural planning, focusing on eco-friendly dwelling environment. A field survey with 46 subjects has been carried out with structured questionnaire. Some problems in planning of the complex building have been discussed in terms of environmental issues and design criteria. In conclusion, basic planning directions for improving the building environmental quality have been suggested.