• Title/Summary/Keyword: building direction

Search Result 1,295, Processing Time 0.026 seconds

Seismic Analysis of Building Structures with Ambiguous Modal Direction (모드의 방향이 불분명한 건축구조물의 지진해석)

  • 김태호;이동근;김대곤
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.513-520
    • /
    • 2002
  • This study is for seismic analysis of building structures with ambiguous modal direction This case is revealed symmetrical building structure or the structure that isn't coincided building axis with physical axis. Seismic analysis-time history analysis, response spectrum analysis and lateral force procedure-is carried out. It is concluded that analysis method for the structure with ambiguous modal direction don't suitable for lateral force procedure. It is recommended to use the CQC method for combining modal responses to the individual components and the SRSS rule for combining responses to the two horizontal components are of nearly equal intensities.

  • PDF

Comparison of Mechanical Properties and Form Accuracy in FDM 3D Printing Based on Building Conditions (FDM 방식 3D 프린팅에서 제작 조건에 따른 기계적물성치와 형상정밀도의 실험적 비교)

  • Kim, Gi-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.8
    • /
    • pp.52-59
    • /
    • 2021
  • In this study, we experimentally evaluated the mechanical properties and geometric form accuracy in FDM 3D printing processes based on the printing direction, building direction, and layer thickness. The specimen test results showed that the tensile strength increased by over 33% in the printing direction compared to the direction perpendicular to printing and the tensile strength becomes larger as the layer thickness decreased. Furthermore, the tensile and impact strengths in the building direction were significantly reduced due to the difference in the interlayer joining and bonding strengths of the fused material. Additionally, shrinkage of the material due to phase change induced curl distortion especially in thin and long 3D-printed products, which increased as the layer thickness increased.

A Study on the Wind Characteristics of Skyscraper Prevailing Wind Direction (초고층건물 탁월풍 방향의 바람 특성에 관한 연구)

  • Kim, Jae-Cheol;Lee, Kyoo-Seock
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.6
    • /
    • pp.503-510
    • /
    • 2007
  • Since 1990s many skyscrapers have been built in Seoul. However, gusty winds occur among tall buildings by descending turbulences due to the upper air blocking. This study aims to investigate the wind characteristics of skyscraper prevailing wind direction. In order to evaluate the building wind in this area, The wind speed and the wind direction were measured using propeller type RM-Young wind monitor in this study. The maximum wind speed was recorded by 15.1 m/sec and the main wind direction is WNW and NW. The ultimate purpose of this study is to figure out the phenomena of building wind impact and also to provide essential basic data for establishing proper guidelines in building wind impact assessment for skyscrapers in Korea.

A Study on the Prescriptions of American Codes for Straw Bale Structures and the Legislation Direction of Korean Straw Bale Code (미국 짚단벽구조 법규 분석 및 국내의 법제화 방향 연구)

  • Kim, Jeong-Gyu
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.91-98
    • /
    • 2009
  • The purpose of this study is analyzing the prescriptions of American codes for straw bale structures and proposing the legislation direction of Korean building code. The process of this study is as follows: (1) To set up the legislation direction of straw bale code of Korea, this study investigated the current state and features of straw bale houses in Korea, and looked into the worldwide status of straw bale codes and permitting. (2) To provide basic data for the legislation of Korean straw bale code or guideline, this study analyzed American codes for straw bale structures like the Tucson/Pima County Arizona Building Code Appendix Chapter 72 - Straw-Bale Structures, California State Guidelines for Straw-Bale Structures, New Mexico Standards for Non-load Bearing Baled Straw Construction, Oregon State Residential Code Appendix M - Straw-Bale Structures and so on. The analysis items are the scope of rule application, material specifications, requirements for straw bale walls/foundations and construction requirements. (3) On the base of analysis of American straw bale codes, this study proposed the legislation process and direction of Korean straw bale code and guideline.

Comparison and Analysis of Domestic and Foreign Building Energy Rating Systems (국내외 건물 에너지성능 인증제도 비교, 분석)

  • Song, Seung-Yeong;Lee, Soo-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.77-85
    • /
    • 2007
  • With the increase in the demand for sustainable and environment-friendly development all over the world, it becomes an urgent issue for Korea to reduce $CO_2$ emission. Since building industry accounts for about 40% of international energy and resource consumption and $30{\sim}40%$ of $CO_2$ emission, it is essential to prepare for energy-efficient building. This study aims to seek for improvement direction for a domestic Building Energy Efficiency Rating System through the comparison with foreign systems. Two foreign building energy rating systems which have the similar application scope with domestic one, HERS(Home Energy Rating System) and SAP(Standard Assessment Procedure)2005 were selected. As compared with foreign systems, we intended to suggest improvement direction for effective application of Building Energy Efficiency Rating System in Korea.

A Study on the Site Planning of an Apartment Complex for Improving the Outdoor and Indoor Air Quality (아파트의 실내외 공기질 향상을 위한 주동 배치 계획 연구)

  • Shin, Jee-Woong;Kim, Tae-Yeon;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.195-202
    • /
    • 2004
  • This study focuses on the impacts of apartment building arrangements on the outdoor and indoor air quality - the efficiency of natural ventilation in the outside/inside area of an apartment with consideration to the characteristics of an air flow in outside area depending on the types of the arrangements, the main direction of the wind, and the outside wind pressure on the building facade. As indices to evaluate the efficiency of natural ventilation, the concepts of "Age of Air" and "Purging Flow Rate(PFR)" were used in this study. As indices to classify the efficiency of indoor natural ventilation, the mean values of the wind pressure differences between the front and the back elevations of an apartment building were used. The research showed that the PFR of each apartment building arrangement ranges from 0.867 to 3.253. The "minus-shaped" arrangement showed the highest PFR, 2.306; the "zigzag-shaped" arrangement measured 1.889; the "angle-shaped" arrangement measured 1.465, and the "square-shaped" arrangement measured 1.241. Depending on the direction of the wind, the pressure differences range extremely, with variations from 170% to 2300%. Thus, the indoor natural ventilation efficiency can be changed by the pressure differences of the wind, which are sensitive to the main direction of the wind even though the structure and planning of the apartment complexes are the same. Despite the same direction of the wind, even the efficiency can be diverse. This study showed how to predict the most beneficial apartment building arrangement for the profitable natural ventilation efficiency in each direction of the wind.

A Comparison Study on the Street Canyon Wind and Prevailing Wind Characteristics at Skyscraper Area in Winter (초고층건물 주변 겨울철 탁월풍과 도로협곡풍 특성에 관한 비교 연구)

  • Kim, Jae-Cheol;Lee, Kyoo-Seock
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.1
    • /
    • pp.33-38
    • /
    • 2008
  • To investigate the building wind characteristics of skyscraper nearby areas, two points were selected and the wind speed and the wind direction data were measured using 2-D ultrasonic anemometer and propeller type wind monitor during the winter time. The study site is Dohgok-dong, Seoul. After measurement, wind data whose speed is equal to or more than Beaufort level five were selected, classified and analyzed in terms of direction, velocity level and hourly difference. The prevailing wind point is higher than street canyon in terms of intensity and frequency. The main direction is also different. This study aims to figure out the phenomena of building wind impact and also to provide essential basic data for establishing proper guidelines in building wind impact assessment for skyscrapers in Korea.

Modelling the dispersion of a tracer gas in the wake of an isolated low-rise building

  • Quinn, A.D.;Wilson, M.;Reynolds, A.M.;Couling, S.B.;Hoxey, R.P.
    • Wind and Structures
    • /
    • v.4 no.1
    • /
    • pp.31-44
    • /
    • 2001
  • Mean concentrations of ammonia gas released as a tracer from an isolated low-rise building have been measured and predicted. Predictions were calculated using computational fluid dynamics (CFD) and two dispersion models: a diffusion model and a Lagrangian particle tracking technique. Explicit account was taken of the natural variation of wind direction by a technique based on the weighted summation of individual steady state wind direction results according to the probability density function of the wind direction. The results indicated that at distances >3 building heights downstream the weighted predictions from either model are satisfactory but that in the near wake the diffusion model is less successful. Weighted solutions give significantly improved predictions over unweighted results. Lack of plume spread is identified as the main cause of inaccuracies in predictions and this is linked to inadequate resolution of flow features and mixing in the CFD model. Further work on non-steady state simulation of wake flows for dispersion studies is recommended.

A Direction of Energy Rating System for Existing buildings (기존 건축물 에너지 성능 개선 제도의 방향성 제안)

  • Hong, Sim-Hee;Lee, Seul-Ki;Yu, Jung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.149-150
    • /
    • 2013
  • Energy systems in increasing energy efficiency are actively performed at home and abroad. But Generally systems in the country are limited in a new building or sort of some buildings like a public and office building. So, this research suggest a new direction of energy system for existing buildings. It need to set a new bound for containing the green remodeling. For a direction, we analysis domestic energy system in perform and compared their bounds, standard and methods of energy evaluation. This study is necessary for an additional research for proposing detailed evaluation items and for a feasibility study research. And it contribute to develope internal energy systems and set a new system bound.

  • PDF

The Analysis of Evaluation Items of Korea Green Building Certification Criteria in Office Building - Focusing on the Case Study of Office Building Certificated by GBCC from 2010 to 2012 - (국내 업무시설 부문의 친환경건축물 인증 평가항목 분석 - 2010년~2012년 국내 친환경 인증 업무시설의 사례 분석을 중심으로 -)

  • Kim, Chang-Sung
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.2
    • /
    • pp.11-19
    • /
    • 2013
  • Korea Government have carried out various policies to save the Earth environment from global warming and environmental pollution. It has also executed the Green Building Certification Criteria(GBCC) in 2002. The GBCC of office building was executed in 2003 and was revised twice in 2010 and 2011. Concerns about green building construction were quite increasing to keep the building performances sustainable. The aims of this paper is to check the reliability of weighting factors and scoring difficulties in all assessment categories of GBCC and to suggest the amendment direction of the future assessment criteria for green building. For the study, the old and new version of GBCC were examined to present the revision direction of GBCC and the 10 cases certificated by the old and new version, respectively 5 were analysed to compare with the difficulties in obtaining the certification. According to the results of the study, the GBCC requires additional amendments about the assessment categories of the energy consumption monitoring and the building commissioning as required subjects in order to secure the building performances. In addition, the operation mamagement of the building need to be assessed more intensively.