• Title/Summary/Keyword: building demolition

Search Result 172, Processing Time 0.029 seconds

A Method to make Existing RC Structures Fragile, using the Principle of Induction Heating (유도가열 방식을 이용한 기존 RC부재의 해체기술개발 -철근의 승온특성-)

  • Lim, Myung-Kwan;Park, Jong-Hyup;Lee, Jong-Sik;Cho, Seung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.227-228
    • /
    • 2017
  • In this study, the inductor heating which is confined to the metal processing is used by demolition technology in reinforced concrete. And, the purpose is the verification of realization for this technology. Using the inductor heating device, the temperature rising is measured depending on the difference of the generating capacity. And, the demolition of reinforced concrete is evaluated by the vulnerability of concrete due to the inductor heating of rebar in reinforced concrete.

  • PDF

Derivation of predicted equation for scattered asbestos concentration generated while removing asbestos (석면 해체시 발생되는 비산 석면 농도 예측식 도출)

  • Kim, Doh-Hyoung;Jo, Min-Do;Choi, Young-Jun;Han, Seung-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.6-7
    • /
    • 2019
  • Asbestos has been widely used for construction materials due to its sound absorption and insulation properties. Despite the announcement that asbestos may cause cancer, asbestos demolition work has become more active. Asbestos was scattered by demolition work and the government started to regulate it. This study was started to predict the scattering asbestos concentration according to the research that it can cause cancer even if the concentration of asbestos meets legal standards. Therefore, in this paper, a regression analysis was conducted to derive a predictive equation after collecting and arranging the variables affecting scattering asbestos. As well as, artificial neural network analysis was used to make a more suitable prediction model.

  • PDF

Systematic Improvement of Safety Management-Related Laws in Domestic Demolition Works (국내 해체공사 안전관리 관련 법령의 체계적인 개선방안)

  • Ha, Gee-Joo;Ha, Jae-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.169-178
    • /
    • 2010
  • Generally speaking, the demolition works is the subsequent construction activity which has been done after building life-span of twenty two years or so. However, it was not prepared suitable systems and laws and regulations as long-term solutions. In this study, it was suggested the improvement guideline of safety management-related laws in domestic demolition works. The three improvement of laws was suggested as follows. ${\bullet}$ First, it was suggested proposals for demolition works standards in safety management plan of management law for construction activity. ${\bullet}$ Secondly, it was provided improvements for standard safety work guide of demolition works of industrial safety and health law. ${\bullet}$ Third, it was proposed integration method of redundancy in safety management plan and risk assessment regulations.

Variations of the Pollutant Concentration by Explosive Demolition of a Building and Management Plan of Non-point Source Pollution (구조물의 해체 공정별 오염농도 변화 및 비점오염원 관리 방안)

  • Chu, Kyoung-Hoon;Yoo, Sung-Soo;Kim, Hyo-Jin;Lee, Kyoung-Hee;Ko, Kwang-Baik
    • Explosives and Blasting
    • /
    • v.29 no.1
    • /
    • pp.17-26
    • /
    • 2011
  • In this study, the pollutants contained in water and soil samples taken from the explosive demolition site were examined to investigate the effects on environment, and management plan of non-point source pollution in the demolition site was suggested through characterizing the movement of the pollutant with time. As results, pH value of the water and soil samples after the demolition work was 8.5~9.3 which exceeds the Korean environmental criterion of water and soil range due to calcium hydroxide compounds in the concrete. The concentration level of heavy metals caused by the explosive demolition doesn't exceed the environmental criterion of water and soil doesn't exceed the environmental criterion of water and soil quality, and the influence of water and soil pollution on the environment was not considered. The concentration of the heavy metals was analyzed and that of Cr, Cu, Zn and Hg among the heavy metals increased after the drilling and explosive demolition. This says that concentration of the heavy metals during explosive demolition works needs to be monitored. The most pollutants with time or rain dilution into the demolition site decreased and this means that the pollutants caused by the explosive demolition might have influenced to vicinity of the demolition sites as non-point pollution.

Evaluation of Thermal Environment of External Space following the Fence Demolition Campaign in Detached Housing Area (담장허물기로 인한 주택지 외부공간의 열환경 평가)

  • Ryu, Ji-Won;Jung, Eung-Ho;Shimizu, Aki;Oh, Sang-Hak;Hoyano, Akira
    • Journal of the Korean housing association
    • /
    • v.23 no.1
    • /
    • pp.19-26
    • /
    • 2012
  • This study examines how fence demolition may change the thermal environments of external spaces of houses and suggests what factors need to be considered when a fence is demolished. The results of the research are summarized as follows. In terms of the surface temperature, there was no significant difference in all time plots after the removal of all materials. However, applying greening methods (changing the surface materials, planting trees, and building a green roof following fence demolition) could lower the surface temperatures, calling for proper plans for various greening methods. The MRT results indicates that walls block solar radiation and provide shade, reducing radiant heat from roads and surrounding structures during the daytime when solar radiation directly effects surface temperatures. Also, the application of greening methods such as planting vegetation and trees could have shading and evapotranspiration effects, leading to a lower temperature distribution. The HIP results were similar to the MRT results. They indicated that walls block solar radiation within the residential sections and provide shade, resulting in a lower temperature distribution during the daytime. However, areas where greening methods such as a green roof or tree planting were applied showed $1{\sim}2^{\circ}C$ difference in temperature distribution.

Method for clearance of contaminated buildings in Korea research reactor 1 and 2

  • Geun-Ho Kim ;Dooseong Hwang;Jung Ho Song;Junhyuck Im;Junhee Lee ;Minyoung Kang ;Kwang Pyo Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.1959-1965
    • /
    • 2023
  • The objective of this study was the establishment of clearance method that can ensure radiological safety and reasonably minimize radioactive waste when demolishing contaminated buildings at KRR-1&2. By reviewing Korean and international laws related to decommissioning, the method for clearance of contaminated buildings presented in this study is to first decontaminate the building and then conduct a radiological safety assessment, such as measuring residual radioactivity, to determine whether the radiation dose criteria for clearance are satisfied. The measurement results meet the radiation dose criteria, the contaminated buildings are regarded as clearance and can be converted into the general buildings. The demolition of the cleared buildings is carried out using conventional demolition methods. The waste generated during the demolition is classified as general construction waste and is disposed of according to relevant laws. The proposed method significantly optimized the number of samples analyzed and reduced the time and cost associated with the decommissioning. The established method will be applied to the ongoing decommissioning of contaminated buildings at KRR-1&2, and its application will be verified by regulatory bodies. The study suggests that this method could be used for the decommissioning of contaminated buildings at other Korean nuclear facilities in the future.

Seismic performance analysis of steel-brace RC frame using topology optimization

  • Qiao, Shengfang;Liang, Huqing;Tang, Mengxiong;Wang, Wanying;Hu, Hesong
    • Structural Engineering and Mechanics
    • /
    • v.71 no.4
    • /
    • pp.417-432
    • /
    • 2019
  • Seismic performance analysis of steel-brace reinforced concrete (RC) frame using topology optimization in highly seismic region was discussed in this research. Topology optimization based on truss-like material model was used, which was to minimum volume in full-stress method. Optimized bracing systems of low-rise, mid-rise and high-rise RC frames were established, and optimized bracing systems of substructure were also gained under different constraint conditions. Thereafter, different structure models based on optimized bracing systems were proposed and applied. Last, structural strength, structural stiffness, structural ductility, collapse resistant capacity, collapse probability and demolition probability were studied. Moreover, the brace buckling was discussed. The results show that bracing system of RC frame could be derived using topology optimization, and bracing system based on truss-like model could help to resolve numerical instabilities. Bracing system of topology optimization was more effective to enhance structural stiffness and strength, especially in mid-rise and high-rise frames. Moreover, bracing system of topology optimization contributes to increase collapse resistant capacity, as well as reduces collapse probability and accumulated demolition probability. However, brace buckling might weaken beneficial effects.

Building waste management plan using BIM and RFID technology (BIM과 RFID 기술을 활용한 건설 폐기물 관리 방안)

  • Duan, Chen;An, Ie-sle;Ham, Nam-Hyuk;Kim, Jae-Jun
    • Journal of KIBIM
    • /
    • v.12 no.2
    • /
    • pp.26-39
    • /
    • 2022
  • The purpose of this study is to establish a novel system for on-site management of construction and demolition waste. Construction waste has always been one of largest waste in the world and has long lacked an effective management system. Although various countries have planned the disposal of waste at the political level, the real-time and effective management of construction sites has not been mentioned. Especially in China, the continuous development of the construction industry also generates a large amount of waste, and China is not prepared for a large amount of construction waste. In order to alleviate the huge impact of construction waste on society and the environment, this study proposes a waste management method that combines Building Information Modeling technology and Radio Frequency Identification technology. Through this research, by using information technology to manage the generation and discharge of construction waste, and record the amount and information of waste generation, also improve the management method of construction waste.

A Study of Cutting Method of H-Pile for Explosive Demolition of SRC Structure (철골구조물 발파해체를 위한 H형강 절단방법에 대한 연구)

  • Min Hyung-Dong;Lee Yun-Jae;Song Young-Suk;Kim Hyo-Jin
    • Explosives and Blasting
    • /
    • v.23 no.3
    • /
    • pp.83-89
    • /
    • 2005
  • It follows in deterioration of the steel frame structure and becomes remodeling and removal. The construction work characteristic, economical efficiency and stability environment characteristic are planned and considered hereafter control plan of the steel frame structure which is deteriorated currently to cutting mettled plentifully sued on gas cutting of H beam. However it will not be able to apply from the explosives demolition which is makes a weak instantaneously and then collapses the building at the time. In this study, shape charge was used for cutting of the H-beam. That is the element testing to estimate explosives demolition for steel frame structure. As a result, it is found for single-side rutting method, both-sides rutting methods by H-beam thickness and pre-rutting process. It confirmed an affix method and an ease characteristic by fixing tool. Also, it is shown that air blasting decreased about 8dB(A) in order to reduce air blasting used by sand box. However, it will be required to reduce air blasting little more because explosives demolition will be done in urban site.