A Study on the Calculation of Ventilation Rate in Apartment House according to VOCs and HCHO Substances of Building Material and Furniture (건축 마감재와 가구재의 VOCs, HCHO 유해물질에 따른 공동주택 적정 환기량 산정에 관한 연구)

  • Choi Jeong-Min;Park Jin-Seok;Son Young-Hwan;Park Chang-Sub;Park Min-Yong;Lee Kyung-Hee
    • Journal of the Korean housing association
    • /
    • v.16 no.4
    • /
    • pp.101-108
    • /
    • 2005
  • Because of the airtightness of building, misuse of building materials and abuse of furniture, indoor air pollution problems have been increasingly concerned especially with apartment buildings. To improve the IAQ(Indoor Air Quality) in apartment building, this study was aimed at analyzing the factor of interior building material and furniture and calculating the ventilation rate of living room and bed room according to the surface area of interior building material and furniture in terms of VOCs(Volatile Organic Compounds) and HCHO(Formaldehyde). The results of this study are as follows; 1) In the concerned rooms, the living room has less pollution emission rate L(surface area/volume) than that of the bed room but, the living room needs more ventilation rate than that of the bed room because of built-in furniture in terms of VOCs and HCHO. 2) Built-in interior furniture is very important factor in IAQ problems of apartment building, but until now there is no provision about the built-in furniture, so that the provision must be regulated to control the IAQ. 3) To control the IAQ problem, the effective ventilation plans must be established according to the required ventilation rate by means of natural or mechanical ventilation method.

A Study on Configuration of Small Wind Turbines for Maximum Capacity of Wind Power Systems Interconnected With a Building (빌딩 내 최대 풍력발전설비 연계를 위한 소형풍력발전원 구성에 관한 연구)

  • Lee, Yeo-Jin;Kim, Sung-Yul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.4
    • /
    • pp.605-612
    • /
    • 2017
  • One of the biggest environmental issues that our world has been facing is climate change. In order to cope with such environmental issues, the world is putting a great deal of effort into energy conservation. The building sector, in particular, consumes 36% of the energy consumed worldwide and emits considerable amount of greenhouse gases. Therefore, introduction of renewable energies in the building sector is highly recommended. Renewable energy sources that can be utilized in the building sector include sunlight, solar heat, geothermal heat, fuel cells and wind power. The wind power generation system which converts wind energy into electrical energy has advantages in that wind is an unlimited and pollution-free resource. It is suitable to be connected to existing buildings because many years of operational experience and the enhanced stability of the system have made it possible to downsize the electrical generator. In case of existing buildings, it is necessary to consider the live loads of the buildings to connect the wind power generation system. This paper, through the connection of the wind power generation with existing buildings, promotes reduction of greenhouse gas emissions and energy independence by reducing energy consumption in the building sector. In order to connect the wind power generation system with an exciting building, the live load of the building and the area of the rooftop should be considered. The installable model is selected by comparing the live load of the building and the load of the wind power generation system. The maximum number of the wind turbines that can be installed is obtained by considering the separation distance between the wind turbines within the area of the rooftop. Installations are divided into single installations and multiple installations of two different types of wind turbines. After determining the maximum installable number, the optimal model that can achieve the maximum annual power generation will be selected by comparing the respective total annual amount of the power generation of different models.

Normative Building Types and Layout of Ruling Class Residences in the Seoul area in the Early Joseon Dynasty (조선 전기 서울 지역 지배층 저택의 규범적 건물 유형과 배치)

  • Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.32 no.5
    • /
    • pp.69-80
    • /
    • 2023
  • Before the 15th century, the main buildings of the residences of the ruling class in Seoul consisted of Momchae(身梗), Seocheong(西廳), and Naeru(內樓)‧Chimru(寢樓). Based on the equality of the relationship between husband and wife, the couple lived in the main building[Momchae] in the center of the mansion, but based on the individuality of the relationship between husband and wife, each had an area consisting of the same section within the building. Naeru·Chimru was the two floors bedroom building became a common living space for the minister and wife, upstairs in summer, downstairs in winter. In preparation for large gatherings and important receptions, an open-structured West Hall(西廳) was located on the west side of the mansion. Momchae, Seocheong, and Naeru‧Chimru were the common building types and layouts of the residences of the highest ruling class, including high-ranking officials, until the reign of King Sejong. However, from around the time of King Seongjong, Seocheong and Chimru came to be regarded as privileged and luxurious buildings only allowed for the grand prince's residence. The layout of the bedroom, main building (including Wings), Outer Sarang[外舍廊], and Joyangru[朝陽樓] of Prince Bongrim's mansion built in the first half of the 17th century clearly shows the transitional period when the arrangement of chimru, main building, and western office was disrupted and the layout changed to the Inner main building(Anchae for wife) and Outer main building(Sarangchae for husband).

A Study on the Reference Building based on the Building Design Trends for Non-residential Buildings (건축물 설계현황 분석을 통한 국내 비주거용 표준건물의 설정에 관한 연구)

  • Jeong, Young-Sun;Jung, Hae-Kwon;Jang, Hee-Kyung;Yu, Ki-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.1-11
    • /
    • 2014
  • The Korean government plans to introduce the building energy performance standard which regulates the annual energy consumption of buildings. This paper aimed to set up the reference building from database based on the building design trends for non-residential buildings. We surveyed the design data of 435 non-residential buildings which were granted building permission from 2007 to 2011. And we conducted estimation on the heating & cooling load and the energy consumption of the reference building using ECO2 program. From results, the reference building of non-residential buildings was office building which had a total 7 floors and $20,838m^2$ gross floor area. And it suggests the design reference data of building envelope, HAVC, heat source equipment and lighting system for the reference building. The total annual energy use of the reference building was $151.9kWh/m^2yr$.

Strength Estimation of the High Strength Concrete by using Rock Test Hammer (암반용 테스트해머 사용에 의한 고강도콘크리트의 강도추정)

  • Seo, Yun-A;Nam, Kyung-Yong;Park, Soo-Hwa;Kim, Seong-Deok;Lim, Nam-Gi;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.77-79
    • /
    • 2012
  • This paper intends to review possible application in the high strength area through compressive strength estimation of the simulated high strength concrete member using Rock Test Hammer and suggest it as a reference data for the strength estimation technique of the ultra high strength concrete in the future. From the results of our test, in the low strength area less than 15MPa and normal strength area in 15~60MPa, as shown on the existing studies, it is indicated that P Type Schmidt Hammer in the low strength area and N Type Schmidt Hammer in the normal strength area have high correlation of rebound-compressive strength. As the Rock Test Hammer indicated more or less reduced accuracy in the low strength area and the normal strength area but high correlation on the high strength area (50~100MPa) defined on this test, it is determined that it would be possible to make the fastest and simplest compressive strength estimation on the site where the high strength concrete is applied.

  • PDF

Characteristics of Block Formation and Commercialization of Residential Blocks commercial area along Urban Arteries - Case study of commercial and residential area on Teheran-ro in Gangnam-gu in Seoul- (간선도로변 상업지역 배후 주거지의 가구배치와 상업화 특성 -서울시 강남구 테헤란로 주변 상업지역과 주거지역 사례연구 -)

  • Hong, Jae-Hong;Yang, Woo-Hyun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.229-234
    • /
    • 2005
  • The purpose of this study is to analyze a Characteristics of block formation and commercialization of residential books commercial area along urban arteries on Teheran-ro in Seoul. 'Teheran-ro' is selected as a case site to analyze the characteristics of residential blocks commercial area along urban arteries. The study analyzes the characteristics of the street network and block formation in commercial area along arteries and rear residential blocks, and commercialization of residential blocks commercial area along urban arteries according to the characteristics of street network and block formation. The analysis about block formation progress about i ) a street network and block formation, ii ) the scale of blocks, iii) division of lots, iv) lots system. The analysis about commercialization of residential blocks commercial area progress about i) a street network and block formation, ii) a density of building, iii) a use of building

  • PDF

Impact of Green Building Rating System on an Apartment Housing Price (친환경인증제도가 주택가격에 미치는 영향 분석)

  • Shon, Young Jin;Lee, Sang Hyo;Kim, Jae Jun
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.131-136
    • /
    • 2010
  • Because energy consumption of the construction part is very high, there is a growing need to introduce environment-friendly buildings. Therefore Green Building Rating System is enacted in Korea. Though environment-friendly factors such as green area affect the apartment housing price, there's no saying whether Green Building Rating System directly affect the apartment housing price. The purpose of this paper is to estimate the impact of Green Building Rating System on an apartment housing price. The analysis result demonstrated that Green Building Rating System don't affect the apartment housing price. This result means that there is a problem with the effectiveness of Green Building Rating System. The government ought to institute incentive program to ctivate the market of environment-friendly building.

The Development of Automated Building Equipment Design System Using 3D CAD Building Information (3차원 CAD정보를 활용한 건축설비 자동화시스템 구축에 관한 기초연구)

  • Song, Kyoo-Dong;Song, Seung-Yeong;Jeung, Woo-Shin
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.357-360
    • /
    • 2007
  • In the area of domestic construction industry, recently, standardization of construction. globalization of constructional and a building information arc required to advance increase productivity, shorten the term of works and reduce the cost of construction. The objective of this is to offer basic data of process new thesis and development for automated building equipment design system based on 3D CAD building information. This study contribute the development of automated Building equipment design system based on 3D which helps to conduct the equipment design handily and quickly.

  • PDF

Collaborative Relationship Analysis between Members of Apartment Construction Organizations

  • Kim, Jae-Yeob
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.1
    • /
    • pp.102-109
    • /
    • 2014
  • The purpose of this study is to analyze collaborative relationship between members of a building construction organization. For the analysis of collaborative relationship, this researcher collected data by conducting a questionnaire survey with members of three large building construction organizations for apartment housing. The analyzed contents of collaborative relationship were the 'frequency of communication between organizational members' and their 'reliability'. According to the analysis of communication network, construction managers had low frequency of communication, whereas those responsible for each area, like construction deputy managers, had high frequency of communication. It indicates that middle managers are at the center of communication related to construction work in construction organizations. According to the analysis of reliability network, construction managers showed highest reliability, and employees at the top level in an organizational map also showed high reliability. Since they generally have a lot of experience, are some older of age, and assume responsibility for work, they are considered to receive reliability from other organizational members. This study proved that it was possible to numerically express reliability of organizational members, which is an abstract concept, and analyze it. Therefore, it is expected that the analysis result will highly be likely to be used in the area of construction management.

A Study on the Preservation and Management Technique of Urban Skylines (도시 스카이라인 보존.관리 기법에 관한 연구(II))

  • 임승빈;박창석;김성준
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.22 no.3
    • /
    • pp.105-120
    • /
    • 1994
  • The major purpose of this study is to suggest a comprehensive and systematic process for the preservation and management of urban skylines. The city of Seoul has been selected as a case study for this process. The results of this study are summarized as follows; 1) An urban landscape masterplan needs to be established before the preparation of the preservation and management plan for urban skylines. 2) Preservation and management plans for urban skylines are suggested in the case Mt. Nam, Han River, Mt. Kwanak in Seoul city. In the case of Mt. Nam and Mt. Kwanak, the control of building heights and guidelines for building height have been studied. For the Han River, various alternatives in building height and disposition have been investigated for the enhancement of the visual quality. 3) Two major steps are suggested for the effective preservation and management of urban skylines. The first step is to prepare an urban landscape masterplan for the whole city, to delineate the skyline preservation area, and to fix controls on building heights in the area. The second step is to divide the whole city into landscape units, to make detailed landscape masterplan for each the units, and to fix controls on building heights in the units. However, only the first step will be necessary in a small city.

  • PDF