• Title/Summary/Keyword: bubble effect

Search Result 426, Processing Time 0.024 seconds

Observation of bubble dynamics under water in high-magnetic fields using a high-speed video camera

  • Lee, Seung-Hwan;Takeda, Minoru
    • Journal of Navigation and Port Research
    • /
    • v.28 no.2
    • /
    • pp.141-148
    • /
    • 2004
  • The observations of rapid motion of bubbles under water for approximately 50ms or less in high . magnetic fields of 10 T have been carried out successfully for the first time. The observation system constructed is composed of a high-speed video camera, a telescope, a cryostat with a split-type superconducting magnet, a light source, a mirror and a transparent sample cell. Using this system, the influence of magnetic field on the path and shape of single bubbles of $O_2$(paramagnetism) and $N_2$ (diamagnetism) has been examined carefully. Experimental values describing the path are in good agreement with theoretical values calculated on the basis of the magneto-Archimedes effect, despite the effect of magnetism on the bubble. However, no effect of magnetism on the shape of the bubble is observed In addition, the influence of magnetic field on drag coefficient of the bubble is discussed.

Temperature History of the Concrete for Retaining Wall Insulated with Double Layered Bubble Sheet in Summer (서중기 2중버블시트로 단열처리된 옹벽의 온도이력 특성)

  • Jung, Eun-Bong;Kim, Kyung-Hun;Jang, Deok-Bae;Kyung, Yeong-Hyeok;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.45-46
    • /
    • 2012
  • This study is intended to use the insulation effect of the dual bubble sheet to review the freezing prevention capability of underground walls by pouring the dual bubble sheet on the retaining walls before the concrete pouring to contemplate the temperature profile for each area of installation and the area of non-installation of the dual bubble sheet, and as a result, the temperature of the concrete was heightened than the ground due to the insulation effect in using the bubble sheet.

  • PDF

Experimental Study on Single Bubble Growth Under Subcooled, Saturated, and Superheated Nucleate Pool Boiling

  • Kim Jeong-Bae;Lee Jang-Ho;Kim Moo-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.692-709
    • /
    • 2006
  • Nucleate pool boiling experiments with constant wall temperature were performed using pure R1l3 for subcooled, saturated, and superheated pool conditions. A microscale heater array and Wheatstone bridge circuits were used to maintain the constant wall temperature and to measure the instantaneous heat flow rate accurately with high temporal and spatial resolutions. Images of bubble growth were taken at 5,000 frames per second using a high-speed CCD camera synchronized with the heat flow rate measurements. The bubble geometry was obtained from the captured bubble images. The effect of the pool conditions on the bubble growth behavior was analyzed using dimensionless parameters for the initial and thermal growth regions. The effect of the pool conditions on the heat flow rate behavior was also examined. This study will provide good experimental data with precise constant wall temperature boundary condition for such works.

The Effect of Bubble Generated during COG Bonding on the Joint Reliability (COG본딩 공정 중 형성된 기포가 접합 신뢰도에 미치는 영향)

  • Choi, Eun-Soo;Yun, Won-Soo;Jeong, Young-Hun;Kim, Bo-Sun;Jin, Song-Wan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.7
    • /
    • pp.21-27
    • /
    • 2010
  • The effect of COG bonding parameters, especially the bonding temperature, on the bonding quality and reliability was investigated in this paper. We measured the bubble area formed in the ACF resin during the bonding process and tried to investigate the relationship between bubble area and bonding peel strength. 85/85 test which exposes a sample to a 85% humidity and $85^{\circ}C$ temperature condition was also carried out. The bubble area was dramatically increased under ~$10^{\circ}C$ lower than recommended bonding temperature. The bubble area formed at the edge of IC chip was larger than the other parts of IC chip. But the peel strength was not associated with the bubble area. High temperature and humid condition made the bubble area larger, but we could not find clear trend of change in the peel strength.

A Study on the Vertical upward Bubble Flow using Image Processing Technique (영상기법을 이용한 수직상향 기포유동에 관한 연구)

  • 서동표;오율권
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.617-623
    • /
    • 2003
  • In the present study, the characteristics of upward bubble flow were experimentally investigated in a liquid bath. The velocity of upward bubble flow was calculated for two different experimental conditions:1) bubble flow without kinetic energy 2) bubble flow with kinetic energy. Bubble flow without kinetic energy starts to undergo the effect of buoyancy l0cm away from the nozzle. Whereas. kinetic energy is dominant before 30 cm away from the nozzle in bubble flow but after this point kinetic energy and inertial force are applied on bubble flow at the same time In addition, as the flow rate increases the maximum velocity point moves to the nozzle. The velocity Profiles near free surface is extremely irregular due to surface flow. Gas volume fraction is high near the nozzle due to gas concentration. but decreases with the increasement of axial position. Gas volume fraction does not vary after the axial position, z=60 in spite of the increasement of flow.

Theoretical Study of Coherent Acoustic Inverse Method for Bubble Sizing in Bubbly Water

  • Choi, Bok-Kyoung;Yoon, Suk-Wang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.4E
    • /
    • pp.3-8
    • /
    • 1996
  • The bubble size distribution is critical information to understand sound propagation and ambient noise in the ocean. To estimate the bubble size distribution in a bubbly water, the sound attenuation has been only in the conventional acoustic bubble sizing method without considering the sound speed variation. However, the effect of the sound speed variation in bubbly water cannot be neglected because of its compressibility variation. The sound attenuation is also affected by the sound speed variation. In this paper, a coherent acoustic bubble sizing inverse technique is introduced as a new bubble sizing technique with considering sound speed variation as well as the sound attenuation. This coherent sizing method is theoretically verified with the bubble distribution functions of single-size, Gaussian, and power-law functions. Its numerical test results with the coherent acoustic bubble sizing method show good agreement with the given bubble distributions.

  • PDF

A Study on the Bubble Flow in the Gas-Liquid Plume (기-액 기둥에서 기포유동에 관한 연구)

  • Seo, Dong-Pyo;Hong, Myung-Seok;Oh, Yool-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2105-2108
    • /
    • 2003
  • The characteristics of upward bubble flow were experimentally investigated in a liquid bath. In the present study, a thermal-infrared camera and high speed CCO camera were used to measure their temperature and local rising velocity, respectively. Heat transfer from bubble surface to water is largely completed within z=10mm from the nozzle, and then the temperature of bubble surface reaches that of water rapidly. The rising velocity of bubble was calculated for two different experimental conditions: 1) bubble flow without kinetic energy 2) with kinetic energy. Bubble flow without kinetic energy starts to undergo the effect of inertia force 10cm away from the nozzle. Whereas, kinetic energy is dominant before 30 cm away from the nozzle in bubble flow, but after this point, kinetic energy and inertial force are applied on bubble flow at the same time.

  • PDF

A Study on the Behavior of Bubbles in Fluidized Bed (유동층내의 기포거동에 대한 연구)

  • 김용섭
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.5
    • /
    • pp.24-28
    • /
    • 1994
  • In the present paper, the behavior of bubbles in a fluidized bed has been investigated experimentally. The bubble size, distribution of bubble, bubble rising velocity and pressure fluctuation in the fluidized bed are obtained at different air velocity. The results are discussed and compared study the effect of air velocity on the behavior of a bubbles in fluidized bed.

  • PDF

Ultrasonic Cavitation Effect Observation Using Bubble Cloud Image Analysis (기포군 영상분석을 통한 초음파 캐비테이션 현상의 변화 관찰)

  • Noh, Si-Cheol;Kim, Ju-Young;Kim, Jin-Su;Kang, Jung-Hoon;Choi, Heung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.124-130
    • /
    • 2011
  • In this study, in order to evaluate the yield of bubble by ultrasonic cavitation in HIFU sonication, the bubble image analysis was performed. The changing phenomenon of cavitation effect according to the sonication condition was discussed by analyzing the bubble image. Especially the appearance of bubble cloud, the size of micro-bubble, and the yield of bubble were considered. The 500 KHz and 1.1 MHz concave type ultrasonic transducers were used for HIFU sonication. Computer controlled digital camera was used to obtain the bubble image, and the binary image processing(binarization coefficient : 0.15) was performed to analyze them. In results of 500 KHz and 1.1 MHz transducer, the area of bubble cloud was increased in proportion to the rise in sonication intensity($R^2$ : 0.7031 and 0.811). The mean size of single microbubble was measured as 98.18 um in 500 KHz sonication, and 63.38 um in 1.1 MHz sonication. In addition, the amount of produced bubble was increased in proportion to sonication intensity. Through the result of this study and further study for variable image processing method, the quantitative evaluation of ultrasonic cavitation effects in HIFU operation could be possible with the linearity associated with the sonication conditions.

The Effect of Partitioning Porous Plate on Bubble Behavior and Gas Hold-up in a Bench Scale (0.36 m × 22 m) Trayed Bubble Column (벤치스케일(0.36 m × 22 m) 다단형 기포탑에서 다공판이 기포의 거동 및 기체 체류량에 미치는 영향)

  • Yang, Jung Hoon;Hur, Young Gul;Lee, Ho-Tae;Yang, Jung-Il;Kim, Hak-Joo;Chun, Dong Hyun;Park, Ji Chan;Jung, Heon
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.505-510
    • /
    • 2012
  • The gas hold-up has a strong relationship with the size distribution and rising velocities of bubbles in a bubble column. Therefore, many previous researchers have studied on the hydrodynamics focusing on the bubble size variation in bubble column. In this study, the bubble behavior was influenced by partitioning porous plates installed at a certain height in a trayed bubble column. The gas hold-up was increased in non-sparging region (H/D > 5) as well as sparging region. We identified the effect of the partitioning porous plate using three trayed bubble columns with different reactor geometries. Furthermore, the bubble break-up frequency and size distribution were observed before and after individual bubbles penetrated through the plate. The arrangement of the plates was also investigated using a 0.15-m-in-diameter bubble column. Based on the result, we applied this design concept to a 0.36-m-in-diameter, 22 m tall trayed bubble column and identified the effect of the partitioning porous plate on the gas hold-up increase.