• Title/Summary/Keyword: brightness mean

Search Result 135, Processing Time 0.029 seconds

The Clinical Analysis of the Nasal Septal Cartilage by Measurement Using Computed Tomography

  • Hwang, So Min;Lim, On;Hwang, Min Kyu;Kim, Min Wook;Lee, Jong Seo
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.3
    • /
    • pp.140-145
    • /
    • 2016
  • Background: The nasal septal cartilage is often used as a donor graft in rhinoplasty operations but can vary widely in size across the patient population. As such, preoperative estimation of the cartilaginous area is important for patient counseling as well as operating planning. We aim to estimate septal cartilage area by using facial computed tomography (CT) studies. Methods: The study was performed using facial CT images taken from 200 patients between January 2012 to July 2015. Using the mid-sagittal image, the boundary of cartilaginous septum was delineated from soft tissue using the mean difference in signal intensity (or brightness). The area within this boundary was calculated. The calculated area for septal cartilage was then compared across age groups and sexes. Results: Overall, the mean area of nasal septal cartilage was $8.18cm^2$ with the maximum of $12.42cm^2$ and the minimum of $4.89cm^2$. The cartilage areas were measured to be larger in men than in women (p<0.05). The area decreased with advancing age (p<0.05). Conclusion: Measuring the size of septal cartilage using brightness difference is more precise and reliable than previously reported methods. This method can be utilized as the standard for prevention of postoperative complication.

A Study on the Diagnostic Detection Ability of the Artificial Proximal Caries by Digora$\textregistered$ (Digora$\textregistered$ 영상시스템을 이용한 인접면 인공 치아우식병소의 진단능에 관한 연구)

  • Oh Kyung-Ran;Choi Eui-Hwan;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.415-433
    • /
    • 1998
  • Digora system is an intraoral indirect digital radiography system utilizing storage phosphor image plate. It has wide dynamic range which allows it to decrease the patient s exposure time and may increase diagnostic ability through image processing (such as edge enhancement, grey scale conversion, brightness change, and contrast enhancement). And also, it can transmit and storage image information. The purpose of this study was to evaluate the diagnostic ability of artificial proximal caries between Conventional radiograph and Digora images(unenhanced image, brightness & contrast controlled image, and edge enhanced image). ROC(Receiver Operating Characteristic) analysis, paired t-tests, and F-tests were done for the statistical evaluation of detectability. The following results were acquired: 1. In Grade I lesions, the mean ROC areas of Conventional radiograph, Digora unenhanced image, Digora controlled image, and Digora edge enhanced image were 0.953, 0.933, 0.965, 0.978 (p>0.05). 2. In Grade II lesions, the mean ROC areas of Conventional radiograph, Digora unenhanced image, Digora controlled image, and Digora edge enhanced image were 0.969, 0.964, 0.988, 0.994. Among theses areas, there was just statistical significance between Diagnostic abilities of Digora edge enhanced image and Conventional radiograph (p<0.05). 3. In the Interobserver variability, the ROC curve areas of Digora edge enhanced image was lowermost in these areas, regardless of the Carious lesion depths. In conclusion, intraoral indirect digital system, Digora system, has the potential possibility as an alternative of Conventional radiograph in the diagnosis of proximal caries.

  • PDF

CONSTRAINING COSMOLOGICAL PARAMETERS WITH IMAGE SEPARATION STATISTICS OF GRAVITATIONALLY LENSED SDSS QUASARS: MEAN IMAGE SEPARATION AND LIKELIHOOD INCORPORATING LENS GALAXY BRIGHTNESS

  • Han, Du-Hwan;Park, Myeong-Gu
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.1
    • /
    • pp.83-92
    • /
    • 2015
  • Recent large scale surveys such as Sloan Digital Sky Survey have produced homogeneous samples of multiple-image gravitationally lensed quasars with well-defined selection effects. Statistical analysis on these can yield independent constraints on cosmological parameters. Here we use the image separation statistics of lensed quasars from Sloan Digital Sky Survey Quasar Lens Search (SQLS) to derive constraints on cosmological parameters. Our analysis does not require knowledge of the magnification bias, which can only be estimated from the detailed knowledge on the quasar luminosity function at all redshifts, and includes the consideration for the bias against small image separation quasars due to selection against faint lens galaxy in the follow-up observations for confirmation. We first use the mean image separation of the lensed quasars as a function of redshift to find that cosmological models with extreme curvature are inconsistent with observed lensed quasars. We then apply the maximum likelihood test to the statistical sample of 16 lensed quasars that have both measured redshift and magnitude of lens galaxy. The likelihood incorporates the probability that the observed image separation is realized given the luminosity of the lens galaxy in the same manner as Im et al. (1997). We find that the 95% confidence range for the cosmological constant (i.e., the vacuum energy density) is $0.72{\leq}{\Omega}_{\Lambda}{\leq}1.0$ for a flat universe. We also find that the equation of state parameter can be consistent with -1 as long as the matter density ${\Omega}_m{\leq}0.4$ (95% confidence range). We conclude that the image separation statistics incorporating the brightness of lens galaxies can provide robust constraints on the cosmological parameters.

Determination of Optimum Threshold for Accuracy of People-counting System Based on Motion Detection

  • Ryu, Hanseul;Song, Junho;Lee, Boram;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.5
    • /
    • pp.299-304
    • /
    • 2015
  • Objectives: A people-counting system measures real-time occupancy through motion detection. Accurate people-counting can be used to calculate suitable ventilation demands. This study determined the optimum motion threshold for a people-counting system. Methods: In a closed room with two occupants moving constantly, different thresholds were tested for the accuracy of a people-counting system. The experiments were conducted at 150, 300, 450 and 600 lux. These levels of brightness included the illumination levels of most public indoor areas. The experiments were repeated with three types of clothing coloration. Results: Overall, a threshold of 16 provided the lowest mean error percentage for the people-counting system. Brightness and clothing color did not have a significant impact on the results. Conclusion: A people-counting system could be used with threshold of 16 for most indoor environments.

DWTHE: Decomposable Weighted and Thresholded Histogram Equalization (DWTHE: 분할 기반의 히스토그램 평활화)

  • Kim, Mary;Chung, Min-Gyo
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.11
    • /
    • pp.856-860
    • /
    • 2009
  • Wang and Ward developed an image contrast enhancement method called WTHE (Weighted and Thresholded Histogram Equalization). In this paper, we propose an improved variant of WTHE called DWTHE(Decomposable WTHE) that enhances WTHE through the use of histogram decomposition. Specifically, DWTHE divides an input histogram by using image's mean brightness or equally-spaced brightness points, computes a probability value for each sub-histogram, modifies the sub-histograms by using those probability values as weights, and then performs histogram equalization on the modified input histogram. As opposed to WTHE that uses a single weight, DWTHE uses multiple weights derived from histogram decomposition. Experimental results show that the proposed method outperforms the previous histogram equalization based methods.

Foundmental Study of Prediction of Natural Disaster Using the Aerial Photo Interpretation (항공사진판독에 의한 자연재해예측을 위한 기초적 연구)

  • Kang, In-Joon;Kwak, Jae-Ha;Jung, Jae-Hyung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.10 no.2
    • /
    • pp.57-62
    • /
    • 1992
  • As population is increased, land use types are changed mountainous areas from flatland in Korea. Because natural disaster as landslides occur of life, property, and environmental damage, prediction of landslides have become increasingly important. We focus on the issue for assessment of landslides, not slope stability analysis for a simple slope site. In this study, we could know the correlations of mean, standard deviation for brightness value of imagery by aerial photo scanning. The range of brightness values and standard deviation of landslide area is 35~65 and tend to increment of value, in the every years. When evaluating large regions with past occurrence of landslides, it is possible to search for correlation of site conditions such as degree of slope, soil characteristics, vegetative cover, and rainfall conditions in aerial photo interpretation data.

  • PDF

A Study on the Luminosity Control of Bulbs by Using PIC (PIC를 이용한 다수의 전구 밝기제어에 관한 연구)

  • Bae, Cherl-O;Park, Young-San
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.13 no.3
    • /
    • pp.235-240
    • /
    • 2007
  • Recently, energy saving buildings are interested in many parts and many types of thermal insulating materials have been developed. The temperature and brightness of inside and outside building are influenced by weather change and sun's brightness and location. The location of building considering the natural daylight is an important parameter to build a building. To modeling the natural daylight, we used 342 electric bulbs which mean artificial daylight. All these bulbs are installed on dome shape frame. Especially it is focused on the luminosity control of each bulb in this paper. The luminosity of bulbs is controlled by phase control using several PIC microprocessors and triacs.

  • PDF

PHOTOMETRIC PROPERTIES OF THE BRIGHT LENTICULAR GALAXY NGC 5102

  • Sohn, Young-Jong;Chun, Mun-Suk;Byun, Yong-Ik
    • Journal of The Korean Astronomical Society
    • /
    • v.24 no.2
    • /
    • pp.151-159
    • /
    • 1991
  • Using the photographic imagery of the SO galaxy NGC 5102, the equivalent luminosity profile and the fractional integrated luminosity curve have been derived. Several photometric parameters of the galaxy, such as a total magnitude ($B_T$), equivalent radius ($r^*_e$), effective surface brightness (${\mu}^*_e$), and concentration indices ($C_{21}$, $C_{32}$) were derived from the luminosity profiles. According to the decomposition method from the nonlinear least squares fitting, photometric parameters of the bulge (${\mu}_e$, $r_e$) and the exponential disk (${\mu}(0)$, ${\alpha}^{-1}$), and the bulge to total luminosity ratio (B/T) were obtained. The derived central disk surface brightness (${\mu} (0)\;=\;22.06\;{\pm}\;0.18\;mag/\Box"$) and the evaluated B/T ratio (= 0.52) of the NGC 5102 are close to the mean values (${\mu} (0)\;=\;21.65\;{\pm}\;0.3\;mag/\Box"$, B/T=0.63) of the SO galaxies. Analysis showed that a lens-like hump is embedded in the equivalent luminosity profile of the NGC 5102.

  • PDF

Clinical Evaluation of the Effects of Far-Infrared Hot & Cool Mask (BBSkinplus) for Skin Care (원적외선냉온마스크(BBSkinplus)의 피부미용개선 임상연구)

  • Yoo, Jae-seob;Barng, Kee-jung;Son, Chang-gue
    • Journal of Fashion Business
    • /
    • v.25 no.2
    • /
    • pp.51-62
    • /
    • 2021
  • This study evaluated the cosmetic effects of a far-infrared hot and cool mask (BBSkinplus) on face skin moisturization, whitening, and wrinkles using a randomized clinical trial. Forty female participants (mean age 47.7 ± 4.6 years) were allocated into the treatment group (BBSkinplus treatment and lotion application twice a day) or the control group (only lotion application twice a day), and moisture, brightness, and wrinkles were measured at 0, 1 and 2 weeks. The average values of each measurement were changed significantly by BBSkinplus treatment compared to the control group. At the 2-week treatment time point, the statistical differences in improvement rates between the two groups were significant at 8.7% vs. 3.9% for moisture (p < 0.01), 0.7% vs. 0.4% for brightness (p < 0.01), and -3.1% vs. 0.0% as Ra and -6.3% vs. 1.5% as R3z for wrinkles (p < 0.05), respectively. No notable complaint was reported regarding any kind of adverse effects such as erythema, itching, or burning. This clinical data support the potential of BBSkinplus as a home beauty device providing moisturizing, whitening, and anti-wrinkle effects on the face.

High-Quality and Robust Reversible Data Hiding by Coefficient Shifting Algorithm

  • Yang, Ching-Yu;Lin, Chih-Hung
    • ETRI Journal
    • /
    • v.34 no.3
    • /
    • pp.429-438
    • /
    • 2012
  • This study presents two reversible data hiding schemes based on the coefficient shifting (CS) algorithm. The first scheme uses the CS algorithm with a mean predictor in the spatial domain to provide a large payload while minimizing distortion. To guard against manipulations, the second scheme uses a robust version of the CS algorithm with feature embedding implemented in the integer wavelet transform domain. Simulations demonstrate that both the payload and peak signal-to-noise ratio generated by the CS algorithm with a mean predictor are better than those generated by existing techniques. In addition, the marked images generated by the variant of the CS algorithm are robust to various manipulations created by JPEG2000 compression, JPEG compression, noise additions, (edge) sharpening, low-pass filtering, bit truncation, brightness, contrast, (color) quantization, winding, zigzag and poster edge distortion, and inversion.