• 제목/요약/키워드: bridge configuration

검색결과 230건 처리시간 0.031초

Analysis and Model Establishment of OF Cable Underneath a Bridge on Underground Power Cable Systems (지중송전계통에서 OF케이블의 교량 첨가시 모델 수립 및 해석)

  • Lee, Hyun-Suk;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2245-2246
    • /
    • 2008
  • This paper analyses crossbonded cable system underneath a bridge. The simulation is performed under various system configuration such as cable length, iron frame size, lightning surge. The simulation models are established by EMTP/ATPDRraw. In this paper, the crossboneded cable system underneath a bridge is also analyzed for insulation coordination of iron frame and cables.

  • PDF

Minimal Medial-row Tie with Suture-bridge Technique for Medium to Large Rotator Cuff Tears

  • Lee, Hyun Il;Ryu, Ho Young;Shim, Sang-Jun;Yoo, Jae Chul
    • Clinics in Shoulder and Elbow
    • /
    • 제18권4호
    • /
    • pp.197-205
    • /
    • 2015
  • Background: The purpose of this study was to evaluate the postoperative magnetic resonance imaging (MRI) results of minimal-tying (one medial-row tie among 4 medial-row sutures) on the medial-row in double-row suture-bridge configuration ($2{\times}2$ anchor with $4{\times}4$ suture stands). Methods: From 2011 March to 2012 July, 79 patients underwent arthroscopic rotator cuff repair using $2{\times}2$ anchor double-row configuration. The mean age was 61.3 years (range, 31-81 years). Two double-loaded suture anchors were used for medial-row. Four medial-row stitches were made with only one medial-row knot-tying (the most anterior suture). Lateral-row was secured using the conventional suture-bridge anchor technique; all 4 strands were used for each anchor. Repair integrity was evaluated with MRI at mean 6.2 months postoperatively. Retear and the pattern of retear, change of fatty infiltration, and muscle atrophy of supraspinatus were evaluated using pre- and postoperative MRI. Results: Repaired tendon integrity was 38 for type I, 30 for type II, 6 for type III, 4 for type IV, and 1 for type V, according to Sugaya classification. Considering type IV/V as retear, the rate was 6.3% (5 out of 79 patients). Medial cuff failure was observed in 4 patients. Fatty atrophy of supraspinatus was significantly improved postoperatively according to Goutallier grading (p=0.01). The level of muscle atrophy of supraspinatus was not changed significantly after surgery. Conclusions: Minimal tying technique with suture configuration of four-by-four strand double-row suture-bridge yielded a lower retear rate (6.3%) in medium to large rotator cuff tears.

Experimental Verification of Sag Sensitivities using Catenary Model for PPWS Configuration Control in a Suspension Bridge (모형 현수선을 이용한 현수교 PPWS 형상관리를 위한 새그민감도의 실험적 검증)

  • Jeong, Woon;Seo, Ju Won;Lee, Sung Hyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제34권3호
    • /
    • pp.711-721
    • /
    • 2014
  • PPWS, a large number of which a main cable of a suspension bridge consists of, must be precisely erected at a target location under construction considering the differences among design conditions. The absolute sag is measured for several PPWSs, which are reference strands and the relative sag is surveyed from them to other PPWSs, which are divided into several groups. And the adjustment of PPWS length is performed to erect it at target configuration. When PPWS is being under erection in a real bridge site, the procedures are as follows; evaluate sag sensitivities according to sag variation factors, calculate an adjustment length of PPWS corresponding to them and adjust a sag of PPWS by controlling the calculated amount of PPWS length. In this study, the differential-related equations of sag sensitivity were proposed for support movement of PPWS. Before site demonstration study of a series of them, we established a catenary model system and accomplished verification tests of them. From test results, the validation of them was done.

System-level performance of earthquake-damaged concrete bridges with repaired columns

  • Giacomo Fraioli;Yu Tang;Yang Yang;Lesley H. Sneed
    • Computers and Concrete
    • /
    • 제33권4호
    • /
    • pp.361-372
    • /
    • 2024
  • Reinforced concrete (RC) bridge columns are typically designated as the primary source of energy dissipation for a bridge structure during an earthquake. Therefore, seismic repair of RC bridge columns has been studied extensively during the past several decades. On the other hand, few studies have been conducted to evaluate how repaired column members influence the system-level response of an RC bridge structure in subsequent earthquakes. In this study, a numerical model was established to simulate the response of two large-scale RC columns, repaired using different techniques, reported in the literature. The columns were implemented into a prototype bridge model that was subjected to earthquake loading. Incremental dynamic analysis (IDA) and fragility analysis were conducted on numerical bridge models to evaluate the efficacy of the repairs and the post-repair seismic performance of the prototype bridge that included one or more repaired columns in various locations. For the prototype bridge herein modeled, the results showed that a confinement-enhanced oriented repair would not affect the seismic behavior of the prototype bridge. Increasing the strength of the longitudinal reinforcement could effectively reduce the drift of the prototype bridge in subsequent earthquakes. A full repair configuration for the columns was the most effective method for enhancing the seismic performance of the prototype bridge. To obtain a positive effect on seismic performance, a minimum of two repaired columns was required.

Damage detection and localization on a benchmark cable-stayed bridge

  • Domaneschi, Marco;Limongelli, Maria Pina;Martinelli, Luca
    • Earthquakes and Structures
    • /
    • 제8권5호
    • /
    • pp.1113-1126
    • /
    • 2015
  • A damage localization algorithm based on Operational Deformed Shapes and known as Interpolation Damage Detection Method, is herein applied to the finite element model of a cable stayed bridge for detecting and localizing damages in the stays and the supporting steel beams under the bridge deck. Frequency Response Functions have been calculated basing on the responses of the bridge model to low intensity seismic excitations and used to recover the Operational Deformed Shapes both in the transversal and in the vertical direction. The analyses have been carried in the undamaged configuration and repeated in several different damaged configurations. Results show that the method is able to detect the damage and its correct location, provided an accurate estimation of the Operational Deformed Shapes is available. Furthermore, the damage detection algorithm results effective also when damages coexist at the same time at several location of the cable-stayed bridge members.

The Design and Arrangement of Coastal Ship′s Bridge on the Basis of Ergonomic Concept

  • Ha, Weon-Jae;Jong, Jae-Yong;Lee, Hyong-Ki;Park, Young-Soo;Park, Jin-Soo
    • Journal of Navigation and Port Research
    • /
    • 제27권6호
    • /
    • pp.599-604
    • /
    • 2003
  • In this paper, the ergonomic principle and concept will be established and the conceptual bridge design based on the ergonomic studies pertaining to bridge design undertaken by IMO and ISO will be introduced. In particular, this study has looked into the applicability of ergonomic design concept on coastal ships and proposes new bridge design to make good contribution to the prevention of marine accidents in the coastal sea.

Study of Monitering and Analysis Technology for Long Span Bridge Using Multi-GPS (멀티GPS에 의한 장대교량 모니터링 및 분석기술)

  • Choi, Byoung-Gil;Na, Young-Woo;Kim, Young-Gon;Kim, Tae-Hoon
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 한국측량학회 2010년 춘계학술발표회 논문집
    • /
    • pp.195-196
    • /
    • 2010
  • This study aims to methodology a system which is able to monitoring and analysis of long span bridge in real time using multi GPS. Through setting up many GPS at the important points of long span bridge and measuring displacement in real time, over all 3D configuration of bridge could be analyzed. Behavior analyzing system developed in this study is able to digitize and visualize the overall and points displacement of bridge and deal with events actively. Also it is able to calculate statistical data related to analyze behavior through the constricting database of measuring data.

  • PDF

A Study on the Conceptual Bridge Design based on the Ergonomic Background (인간공학적 선교설계에 관한 기초연구)

  • 하원재;나송진;김상수;이형기;정재용
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • 제8권1호
    • /
    • pp.53-59
    • /
    • 2002
  • A correctly designed bridge offers improved operational safety in terms of increased vigilance, flexibility of operation, precision of control and operator's situational awareness. According1y to design human centered bridge, the consideration shall be given to the man-machine interface, location and interrelation of workstation, configuration of console, windows. field of vision and bridge working environment. The state-of-the-art suits for one-man operation by integration of conning information and central information presentation. Further, it is desirable to enable two man ship operation for emergency operations, training purposes and redundancy. In this point of view, this thesis would like to design a conceptual bridge.

  • PDF

Investigation on vortex-induced vibration of a suspension bridge using section and full aeroelastic wind tunnel tests

  • Sun, Yanguo;Li, Mingshui;Liao, Haili
    • Wind and Structures
    • /
    • 제17권6호
    • /
    • pp.565-587
    • /
    • 2013
  • Obvious vortex induced vibration (VIV) was observed during section model wind tunnel tests for a single main cable suspension bridge. An optimized section configuration was found for mitigating excessive amplitude of vibration which is much larger than the one prescribed by Chinese code. In order to verify the maximum amplitude of VIV for optimized girder, a full bridge aeroelastic model wind tunnel test was carried out. The differences between section and full aeroelastic model testing results were discussed. The maximum amplitude derived from section model tests was first interpreted into prototype with a linear VIV approach by considering partial or imperfect correlation of vortex-induced aerodynamic force along span based on Scanlan's semi-empirical linear model. A good consistency between section model and full bridge model was found only by considering the correlation of vortex-induced force along span.

A Double Coupling Full-Bridge Configuration Series Resonant Inverter (이중 결합 Full-Bridge 방식 직렬 공진형 인버터)

  • 배영호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제9권4호
    • /
    • pp.326-333
    • /
    • 2004
  • This research proposes a high frequency resonant inverter for high power conversion apparatus, which is consist of two L-C linked full-bridge inverter using MOSFET in order to distribute voltage and current of the devices. As an output power control strategy, the time sharing control method is applied. From the computer simulation results, the inverters and devices can be shared properly voltage and current rating of the system. And also, theoretical characteristics of the proposed circuit are compared with experimental results.