• Title/Summary/Keyword: breathing zone

Search Result 35, Processing Time 0.029 seconds

Breathing Zone Air Quality in Taegu (인체 호흡 영역에서의 대구시 대기질에 관한 연구)

  • 조완근;손상호
    • Journal of Environmental Science International
    • /
    • v.5 no.1
    • /
    • pp.7-14
    • /
    • 1996
  • Two experiments were conducted to evaluate breathing zone air quality in Taegu, using automatic analyzers for four air quality standards($SO_2$, $NO_2$, CO, and $O_3$). First, air target compounds were measured for 8 to 12 hours in each of two commercial areas and five residential areas. Second, air target compounds were hourly measured for 24 hours in each of two commercial areas, two residential areas, and an industrial complex area. Based on the first experiment the breathing zone air was more polluted in the commercial area as compared to the residential area, while the second experiment showed that the breathing zone air was polluted rather in the residential are3 as compared to the commercial area. The second experiment also indicated that there was some variation of breathing zone air concentration with time and measuring sites. Diurnal variation of breathing zone air concentrations was consistent with previous studies which measured at building height. The highest breathing zone air concentration was shown in Seongseo industrial complex area. An unusual finding of this study was that $SO_2$ concentration in the breathing zone air of Bisandong, a typical residential area of Taegu, was higher than that of other residential areas, even higher than that of Seongseo industrial complex area.

  • PDF

Analysis on ventilation efficiency by CFD simulation for breathing zone in bed room (CFD해석에 의한 침실 호흡역의 환기효율 분석)

  • Yoo, Bok-Hee;Yoon, Chung-Sook
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.11-16
    • /
    • 2002
  • Indoor air environment is one of the most important factors that affect resident's health and comfort level. In this paper, the influence of ventilation efficiency with different types of furniture arrangement at breathing zone in a room was analyzed by numerical simulation based on computational fluid dynamics(CFD). The furniture layout of students' bedroom have been classified by three different patterns so that SVE3(scale for ventilation efficiency3) in the rooms was analyzed for air flow distribution. According to the results of the study, SVE3 has the maximum value in spaces between furnitures and each comer of the room. The furniture arrangement influences the ventilation efficiency. It was con finned that ventilation effective in a room is not uniformly distributed as compared the breathing zone with all the area in a room. It means that a study of ventilation efficiency was considered relatively with target zone(a residential or breathing zone) and all the area in a space.

Analysis on the Age of Air and the Air Change Effectiveness of the Personal Environmental Module System in Intelligent Buildings

  • Cho, Dongwoo
    • Architectural research
    • /
    • v.1 no.1
    • /
    • pp.47-53
    • /
    • 1999
  • An interesting of desktop air-conditioning system is the Personal Environmental Module(PEM) System. The PEM system allows the occupant to choose the desired temperature, air volume and direction of the discharged air. In this study, the measurements on the age of air and the air change effectiveness, using the tracer gas method, are carried out to analyze the ventilation performance for provision of fresh air near the breathing zone by the PEM. The relations between the PEM for optimal control and other factors related to indoor air quality, and the ventilation for the PEM are examined. Also, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The minimum local age of air was measured in the breathing zone, which is directly supplied with air from the PEM diffusers, and the measured local air change effectiveness of the desktop diffuser in the breathing zone was about 1.13 to 1.23 times greater than that of the ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

THE NITROUS OXIDE CONCENTRATION IN BREATHING ZONE ACCORDING TO SCAVENGING METHODS DURING DEEP SEDATION OF PEDIATRIC DENTAL PATIENTS (소아치과 환자의 깊은 진정시 호기가스 제거 방법에 따른 호흡대역에서 Nitrous Oxide 농도 변화)

  • Lee, Chung-Won;Yoon, Hyung-Bae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.124-131
    • /
    • 2003
  • The concentration of nitrous oxide in dental environment has increased especially in pediatric department. In pediatric department frequently met the behavior disordered patients who need the deep sedation. As the deeply sedated patients could not respond well to verbal command, the amount of mouth breathing would be increased especially with mouth prop which backward transposition of mandible. Inhalation of low concentration of nitrous oxide for a long duration has caused various side effects such as spontaneous abortion and inhibition of methionine synthetase activity which is harmful to DNA synthesis. For evaluation of factors of mouth breathing during deep sedation. The author measured the concentration of nitrous oxide in breathing zone by the change of the scavenging methods. One is drain the gas through the tail part of reservoir bag of Jackson Ree's system naturally. Another is scavenge from tail portion of reservoir bag with negative pressure. Last one is scavenge from nasal mask with negative pressure. The nitrous oxide concentration in breathing zone was the lowest in nasal part drainage but high above the recommended concentration of NIOSH. The order of nitrous concentration in breathing zone was: natural drainage, tail part with negative pressure, nasal part with negative pressure. This would reflect the order of resistance of nasal airway and showed the amount of mouth breathing. From the above experiment, the resistance of nasal airway by the increment of gas flow in corrugating tube and reservoir bag would be one of the causative factors of mouth breathing in deeply sedated patients.

  • PDF

Comparison of age of air and air change effectiveness between supply diffuser types (공조취출방식에 따른 공기의 나이 및 환기효율 비교)

  • Cho, D.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

Microenvironmental Exposures To Volatile Organic Compounds (미규모 환경에서의 휘발성 유기화합물 노출)

  • Jo, Wan-Kuen;Gang, Kwi-Wha;Woo, Hyung-Taek;Park, Jong-Kil
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.61-61
    • /
    • 1995
  • Volatile organic compounds(VOCs) are of concern for their potential chronic toxicity, their suspected role in the formation of smog, and their suspected role in destruction of stratospheric ozone. Present study evaluated the exposures to selected VOCs in three microenvironments: 2 chlorinated and 5 aromatic VOCs in the indoor and outdoor air, and 5 aromatic VOCs in the breathing zone air of gas-service station attendants. With permissible Quality Assurance and Quality Control performances VOC concentrations were measured 1) to be higher in indoor air than in outdoor air, 2) to be higher in two Taegu residential areas than in a residential area of Hayang, and 3) to be higher in the nighttime than in the daytime. Among five aromatics, Benzene and Toluene were two most highly measured VOCs in breathing zone air of service station attendants. Based on the sum of VOC concentrations, the VOC exposure during refueling was estimated to be about 10% of indoor and outdoor exposures. For Benzene only, the exposure during refueling was estimated to cause about 52% of indoor and outdoor exposure. The time used to calculate the exposures was 2 minutes for refueling and 24 hours for indoor and outdoor exposures.

Microenvironmental Exposures To Volatile Organic Compounds (미규모 환경에서의 휘발성 유기화합물 노출)

  • 조완근;강귀화
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.447-459
    • /
    • 1995
  • Volatile organic compounds(VOCs) are of concern for their potential chronic toxicity, their suspected role in the formation of smog, and their suspected role in destruction of stratospheric ozone. Present study evaluated the exposures to selected VOCs in three microenvironments: 2 chlorinated and 5 aromatic VOCs in the indoor and outdoor air, and 5 aromatic VOCs in the breathing zone air of gas-service station attendants. With permissible Quality Assurance and Quality Control performances VOC concentrations were measured 1) to be higher in indoor air than in outdoor air, 2) to be higher in two Taegu residential areas than in a residential area of Hayang, and 3) to be higher in the nighttime than in the daytime. Among five aromatics, Benzene and Toluene were two most highly measured VOCs in breathing zone air of service station attendants. Based on the sum of VOC concentrations, the VOC exposure during refueling was estimated to be about 10% of indoor and outdoor exposures. For Benzene only, the exposure during refueling was estimated to cause about 52% of indoor and outdoor exposure. The time used to calculate the exposures was 2 minutes for refueling and 24 hours for indoor and outdoor exposures.

  • PDF

Characteristics of Indoor Air Quality and Local Supply Index with a Variation of Supply ${\cdot}$ Exhaust Airflow rate (환기량 변화에 따른 실내공기질과 국소급기지수 특성)

  • Han, Chang-Woo;Noh, Kwang-Chul;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.21-26
    • /
    • 2005
  • We performed the numerical analysis on the characteristics of indoor air quality and local supply index with a variation of supply · exhaust airflow rate. We analyzed the local supply index and carbon dioxide concentration at the room and breathing zone with respect to the variation of the supply · exhaust airflow rate. From the numerical results, we found that local supply index was affected but carbon dioxide concentration was hardly affected by the variation of the airflow rate in the room. And we also knew that carbon dioxide concentration was raised in despite of the increment of the supply airflow rate in the breathing zone. After this study it is necessary to analyze the local exhaust index when we evaluate the state of the ventilation in the room.

  • PDF

Ammonia and Hydrogen Sulfide Monitoring in Broiler Barns and Cattle Barns (계사 및 우사 내 암모니아 및 황화수소 노출농도 평가)

  • Park, Jihoon;Seok, Jiwon;Lee, Sangah;Kwon, Ohhun;Lee, Kyungsuk;Heo, Yong;Yoon, Chungsik
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.5
    • /
    • pp.277-288
    • /
    • 2015
  • Objectives: There are many hazardous agents at livestock farms. In particular, gases can be detrimental to both workers and animals. This study evaluated ammonia and hydrogen sulfide concentrations in broiler hen barns and beef cattle barns according to sampling location and height. Methods: Three broiler hen barns and three beef cattle barns were selected for gas monitoring in this study. Ammonia and hydrogen sulfide concentrations were measured using a direct-reading instrument which could measure the target gases simultaneously. Gas monitoring was conducted at human breathing height and animal breathing height at three points in each livestock farm. Results: Ammonia concentrations at the broiler hen barns ranged from 3.3 to 12.5 ppm by sampling location and height, but hydrogen sulfide was not detected. In the beef cattle barns, ammonia ranged from 3.1 to 16.3 ppm and low concentrations of hydrogen sulfide were detected at some animal breathing heights. The gas concentrations detected at each livestock farm were significantly higher in the animal breathing zones than in human breathing zones (p<0.0001). Conclusions: We found a difference in gas concentrations between human breathing zones and animal breathing zones. Gas monitoring should be conducted to improve the related environment considering both workers' and animals' health and safety.

Urinary S-Phenylmercapturic Acid as a Biomarker for Biological Monitoring in Workers Exposed to Benzene (벤젠 노출 근로자의 생물학적 모니터링 지표로서의 요중 S-Phenylmercapturic Acid에 관한 연구)

  • Bang, Sin Ho;Kim, Kwang Jong;Yum, Yong Tae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.272-280
    • /
    • 1996
  • This study was to evaluate the associations between urinary S-Phenyl-mercapturic acid(S-PMA) as a new indicator of biological monitoring for low level of exposure to benzene and independent variables such as the air concentration of benzene in the breathing zone of workers, the years of work, and smoking. In this study the subjects were the total of 145 drawn from 53 workers who were occupationally exposed to benzene and 92 workers who were not. The results were as follows: 1. In the workplace geometric mean concentration of benzene in the breathing zone of workers was 0.31 ppm(0.02 - 3.26 ppm) for the spraying workers and 0.25 ppm(0.02 - 3.95 ppm) for the printing workers. 2. The geometric mean of uninary S-PMA for non exposed group was $8.9{\mu}g/g$ creatinine($0.6-72.3{\mu}g/g$ creatinine), 80.3% (74 workers) of the total non-exposed workers indicated less than $20{\mu}g/g$ creatinine of uninary S-PMA. The difference of uninary S-PMA by sex, age, smoking was not significant. 3. The geometric mean of urinary S-PMA for workers who were exposed to benzene was $37.2{\mu}g/g$ creatinine, and was four times higher than that of workers who were not exposed. And 79.3% (42 workers) of the total exposed workers indicated more than $20{\mu}g/g$ creatinine of urinary S-PMA. 4. Regarding the level of benzene in the air, urinary S-PMA was the highest level of $147.9{\mu}g/g$ creatinine in the workers who were exposed to air concentration of 0.5 ppm of benzene and was higher as the level in the air was increased. 5. The correlation coefficient between log urinary S-PMA and log benzene concentration in the breathing zone was 0.80, and the following linear equation was found between urinary log S-PMA and log benzene concentration in the breathing zone : log S-PMA(${\mu}g/g$ creatinine) = 0.564 log benzene in air(ppm) + 0.192 (n=53, r=0.80, p=0.000) In conclusion, the concentration of S-PMA in urine proved to be good parameter for biological monitoring benzene exposure at the workplace even at low level of benzene in air.

  • PDF