• Title/Summary/Keyword: breast ultrasound

Search Result 144, Processing Time 0.026 seconds

Multistage Transfer Learning for Breast Cancer Early Diagnosis via Ultrasound (유방암 조기 진단을 위한 초음파 영상의 다단계 전이 학습)

  • Ayana, Gelan;Park, Jinhyung;Choe, Se-woon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.134-136
    • /
    • 2021
  • Research related to early diagnosis of breast cancer using artificial intelligence algorithms has been actively conducted in recent years. Although various algorithms that classify breast cancer based on a few publicly available ultrasound breast cancer images have been published, these methods show various limitations such as, processing speed and accuracy suitable for the user's purpose. To solve this problem, in this paper, we propose a multi-stage transfer learning where ResNet model trained on ImageNet is transfer learned to microscopic cancer cell line images, which was again transfer learned to classify ultrasound breast cancer images as benign and malignant. The images for the experiment consisted of 250 breast cancer ultrasound images including benign and malignant images and 27,200 cancer cell line images. The proposed multi-stage transfer learning algorithm showed more than 96% accuracy when classifying ultrasound breast cancer images, and is expected to show higher utilization and accuracy through the addition of more cancer cell lines and real-time image processing in the future.

  • PDF

Impact of Using Intra-Operative Ultrasound Guided Breast-Conserving Surgery on Positive Margin and Re-Excision Rates in Breast Cancer Cases with Current SSO/ASTRO Guidelines

  • Thanasitthichai, Somchai;Chaiwerawattana, Arkom;Phadhana-Anake, Oradee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4463-4467
    • /
    • 2016
  • Purpose: To review the impact of using intra-operative ultrasound guided breast conserving surgery with frozen sections on final pathological margin outcome with the current guidelines set forth by the Society of Surgical Oncology (SSO) and the American Society of Surgical Oncology (ASTRO). Materials and Methods: A retrospective review including all cases of intra-operative ultrasound guided breast conserving surgery was performed at the National Cancer Institute Thailand between 2013 and 2016. Patient demographics, tumor variables, intraoperative frozen section and final pathological margin outcomes were collected. Factors for positive or close margins were analyzed. Results: A total of 86 patients aged between 27 and 75 years with intra-operative ultrasound guided breast conserving surgery were included. Three cases (3.5%) of positive margin were detected by intra-operative frozen section and 4 cases (4.7%) by final pathology reports. There were 18 cases (20.9%) with a close margin (<1 mm). Factors affecting this result comprised multi-foci, presence of invasive ductal carcinoma (IDC) combined with ductal carcinoma in situ (DCIS) and invasive lobular carcinoma (ILC). Conclusions: With the current SSO/ASTRO for adequate margin guidelines, using intra-operative ultrasound to locate the boundary for resection with breast conserving surgery provided a high success rate in obtaining final pathology free margin outcomes and minimizing re-operation risks especially when combined with intra-operative frozen section assessment. The chance of finding positive or close margins appears higher in cases of IDC combined with DCIS, ILC and with multi-foci cancers.

Beyond BI-RADS: Nonmass Abnormalities on Breast Ultrasound

  • Hiroko Tsunoda;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.25 no.2
    • /
    • pp.134-145
    • /
    • 2024
  • Abnormalities on breast ultrasound (US) images which do not meet the criteria for masses are referred to as nonmass lesions. These features and outcomes have been investigated in several studies conducted by Asian researchers. However, the term "nonmass" is not included in the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS) 5th edition for US. According to the Japan Association of Breast and Thyroid Sonology guidelines, breast lesions are divided into mass and nonmass. US findings of nonmass abnormalities are classified into five subtypes: abnormalities of the ducts, hypoechoic areas in the mammary glands, architectural distortion, multiple small cysts, and echogenic foci without a hypoechoic area. These findings can be benign or malignant; however, focal or segmental distributions and presence of calcifications suggest malignancy. Intraductal, invasive ductal, and lobular carcinomas can present as nonmass abnormalities. For the nonmass concept to be included in the next BI-RADS and be widely accepted in clinical practice, standardized terminologies, an interpretation algorithm, and outcome-based evidence are required for both screening and diagnostic US.

Comparison of real-time ultrasound imaging for manual lymphatic drainage on breast cancer-related lymphedema in individuals with breast cancer: a preliminary study

  • Seo, Dongkwon;Lee, Seungwon;Choi, Wonjae
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.1
    • /
    • pp.43-48
    • /
    • 2020
  • Objective: Breast cancer-related lymphedema (BCRL) is a major sequela after surgery or radiotherarpy for breast cancer. Manual lymphatic drainage (MLD) is designed to reduce lymph swelling by facilitating lymphatic drainage. This study attempted to determine the histologic changes in the skin and subcutaneous layer, and the immediate effect of MLD in decreasing lymphedema using ultrasound imaging, which is the method used most commonly to eliminate BCRL. Design: A single-group experimental study. Methods: Five subjects who were diagnosed with hemiparetic upper extremity lymphedema more than six months after breast cancer surgery participated in the study. MLD was performed for 60 minutes in the order of the thorax, breast, axilla, and upper arm of the affected side. In order to determine the effect of MLD, ultrasound imaging and limb volume were assessed. Two measurement tools were used for asessing lymphedema thickness among the pretest, posttest, and 30-minute follow-up period. Results: Significant diferences in ultrasound imaging and upper limb volume were found between the affected side and non-affected side (p<0.05). On the affected side, although ultrasound imaging showed a significant decrease after MLD (p<0.05), there were no significant difference in upper limb volume when compared to the baseline. Conclusions: In this study, a significant decrease in lymphedema by MLD was demonstrated by ultrasound imaging, which is considered to be more useful in assessing histological changes than limb volume measurements. Further research on the protocol for eliminating lymphedema will be needed.

Feasibility for Ultrasound Pad Material for the Evaluation Axillary Region of Automated Breast Ultrasound Equipment (자동유방초음파 장비의 액와부 평가를 위한 초음파 패드 물질의 타당성)

  • Seo, Eun-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.231-240
    • /
    • 2018
  • Automated breast ultrasound (ABUS) equipment is a new innovative technique for 3D automatic breast scanning, but limited for the examination in the concave axillary region. The purpose of this study was to determine feasible candidate materials for the ultrasonic wave propagation media in ABUS, enabling the evaluation of the axillary region. Ultrasonography was performed using an ABUS system ($Invenia^{TM}ABUS$, GE, USA) on the ultrasound-specific phantom (UC-551M-0.5, ATS Laboratories, USA) covered by different candidate materials. The validity of feasible candidate materials was evaluated by image quality. Three independent radiological technologists, with more than 10 years of experience, visually assessed on the images. The inter-observer agreements according to the candidate materials were tested using Cronbach's alpha. Unenveloped solidified carrageenan can be a feasible material for the use of ABUS with excellent test reliability. Therefore, the coverage of the axillary region with carrageenan may be effective for ABUS which was originally developed for the convex anatomic structure as female breast.

Can Ultrasound be Used to Differentiate Tubular Adenomas of Breast from Fibroadenomas or Carcinoma?

  • Fu, Ying;Miao, Li-Ying;Ge, Hui-Yu;Mei, Fang;Wang, Jin-Rui
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.3
    • /
    • pp.1269-1274
    • /
    • 2014
  • Breast tubular adenomas are rare benign breast tumors and detailed descriptions of their sonographic appearance are necessary for differential diagnosis from fibroadenomas or breast cancers. This study investigated twenty-one histology-proved tubular adenomas in 17 patients and also included 48 fibroadenomas in 35 patients as a control group. There was no significant difference between the two groups with clinical presentation, which was age, tumor location, tumor number (p>0.05). Statistic analysis showed three significant factors in the differential diagnosis of tubular adenomas and fibroadenomas, including macro-lobulation (p=0.01), "tiny branch like" patterns (p=0.001) and vascularity (p=0.02). Other ultrasonographic features such as echogenicity, border, uniformity of echotexture, posterior acoustic enhancement, lateral wall shadowing were of no clinical significance (p>0.05). Calcifications were seen in three tubular adenomas which were different from those of carcinomas. Although tubular adenomas have some typical characteristics on sonography, surgery and core needle biopsy are still needed for complex cases to exclude progress to malignancy.

Ultrasound-Guided Intervention for Breast Lesions (유방 병변에 대한 초음파 유도하 중재 시술)

  • Eun Young Ko
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.332-344
    • /
    • 2023
  • The role of ultrasound-guided interventions in the diagnosis and treatment of breast lesions is gaining importance and prevalence, particularly as the instances of non-palpable breast lesion detection, breast-conserving surgery, and neoadjuvant chemotherapy are increasing. This review attempts to summarize the types and techniques of breast ultrasound-guided interventional procedures, such as biopsy, tissue marker insertion, and preoperative localization, and their indications. Furthermore, we highlight the pro and cons of the most commonly used procedures with the intention of promoting their use in clinical practice.

Comparative Study of Contrast-Enhanced Ultrasound Qualitative and Quantitative Analysis for Identifying Benign and Malignant Breast Tumor Lumps

  • Liu, Jian;Gao, Yun-Hua;Li, Ding-Dong;Gao, Yan-Chun;Hou, Ling-Mi;Xie, Ting
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.19
    • /
    • pp.8149-8153
    • /
    • 2014
  • Background: To compare the value of contrast-enhanced ultrasound (CEUS) qualitative and quantitative analysis in the identification of breast tumor lumps. Materials and Methods: Qualitative and quantitative indicators of CEUS for 73 cases of breast tumor lumps were retrospectively analyzed by univariate and multivariate approaches. Logistic regression was applied and ROC curves were drawn for evaluation and comparison. Results: The CEUS qualitative indicator-generated regression equation contained three indicators, namely enhanced homogeneity, diameter line expansion and peak intensity grading, which demonstrated prediction accuracy for benign and malignant breast tumor lumps of 91.8%; the quantitative indicator-generated regression equation only contained one indicator, namely the relative peak intensity, and its prediction accuracy was 61.5%. The corresponding areas under the ROC curve for qualitative and quantitative analyses were 91.3% and 75.7%, respectively, which exhibited a statistically significant difference by the Z test (P<0.05). Conclusions: The ability of CEUS qualitative analysis to identify breast tumor lumps is better than with quantitative analysis.

Usefulness of the Mammography and the Breast Ultrasound (유방의 X선 검사와 초음파 검사의 유용성 연구)

  • Lee, In-Ja;Park, Kye-Yeon
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.349-356
    • /
    • 2007
  • Conclusions below are drawn after survey date from 1,969 samplers of mammography and 1,531 breast ultrasound for 10 months, from 1 July 2006 to 30 April 2007. 1. Ages between 40 and 50 of samplers take the largest part of age distribution, and 68.57% of mammography and 71.32% of samplers are fallen under the category. 2. Samplers judged by diseased patients are 31.95% samplers of mammography and 45.79% samplers of breast ultrasound. 3. Age distributions of diseased patients were from 30 to 60 in mammography, 30 to 50 in breast ultrasound. 4. Breast ultrasound shows little difference between left side and right side of diseased part, but mammography shows significant diseased part in both sides. 5. As a result of reading examination, there is higher probability of detection in order of Calcification, Nodular, Mass in mammography. And Cyst, Nodular, Mass in breast ultrasound. 6. As a reading examinations, probability of judging a certain disease in high in mammography, but breast ultrasound shows 1 or 2 kinds of disease.

  • PDF

Phantom Experiments for Breast Cancer Detection by Ultrasound Transmission Period

  • Sakasegawa, Aya;Hoshino, Hirokazu;Tsuji, Kiichi;Hayakawa, Yoshinori
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.481-484
    • /
    • 2002
  • In every cancer early detection and early treatment is the best way to decrease mortality of patients. Moreover early detection of breast cancer increases the possibility of breast conservation treatment. Although mammography is the most powerful modality for early detection, it is hazardous to be used for young women due to X-ray exposure. Another modality of image diagnosis is ultrasound echo technique. But it is not so powerful to detect breast cancer compared to mammography. Palpation is another modality, but is largely dependent on the skill and experience of medical doctors. A new technique is tested its validity in phantom experiments with good results.

  • PDF