• Title/Summary/Keyword: breaker

Search Result 941, Processing Time 0.025 seconds

Measurement of Breaker Noise by Using Breaker Noise Measurement System (브레이커 소음측정시스템을 활용한 소음의 측정 및 평가)

  • Lee, Jae-Won;Kang, Dae-Joon;Gu, J.H.;Park, H.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1173-1176
    • /
    • 2007
  • The breaker noise is one of the main noise sources of construction site. It is very important to assess and measure the breaker noise accurately, because the noise labelling will be in effect January 2008 in Korea. Therefore, It is necessary to measure the sound power level of breakers and use a appropriate test method in accordance with international standard. In this study, we measure the sound power level of breakers by using the breaker noise measurement system. This system makes it possible to measure the breaker noise more accurately than to measure the noise of that attached with excavator, because this system can control main factors affecting breaker noise such as hydraulic input power, hydraulic supply pressure, breaker inlet oil flow and so on.

  • PDF

A Study on the Chip Control in Machining STS304 Using a Chip Breaker (STS304잘삭시 Chip Breaker를 이용한 Chip제어에 관한 연구)

  • Yeom, D.W.;Yu, K.H.;Seo, N.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.6
    • /
    • pp.42-49
    • /
    • 1994
  • One of the parameters that influence the productivity of every industry, involved in metal cutting, is the chip from ; continuous or broken chip. Chip form varies according to machining conditions, material used, tool geometry and chip breaker geometry. Therefore, in this study we carried out the experiment on the chip control in machining STS304 using an attached obstruction type chip breaker. Namely, with the change of a chip breaker distance, chip breaker angle, cutting characteristics in machining STS304 which is well-known as a machining difficult material and produces a saw-toothed chip. The results of the experiment are as follows : 1. The chip breaker distance and angle under which the preferred chip is produced, show 1.5mm and 60 .deg. , while chip breaker angle in machining an ordinary steel was well-known 45 .deg. . 2. During the cutting process, the change of feed than the change of velocity was applied as cutting conditions, effects more clearly on the chip breaking. 3. Considering a whole surface roughness, it is not advisable to apply chip breaker mentioned above for precision cutting.

  • PDF

Development of Circuit Breaker Automatic Selection Program (선박 배선용 차단기 자동 선정 S/W 개발)

  • Ha, Sangho
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2017.10a
    • /
    • pp.88-92
    • /
    • 2017
  • As the considerable request of the fast and accurate way of the selection of circuit breaker is increased, we introduce the development of software of circuit breaker selection for the marine use. Originally, the selection of circuit breaker has been carried out by manual in the marine project. It is not the easy work to select the proper type of circuit breaker to check the time-current characteristic curves of each type of circuit breakers for the various type of loads. In this regards, we developed the software to select the proper type of circuit breaker to confirm fast and accurately. And, we introduce the course of the development of the software for the selection of circuit breaker.

  • PDF

Interruption analysis of the SFCL-combined DC circuit breaker system using current-limiting technology

  • Kim, Jun-Beom;Jeong, In-Sung;Choi, Hye-Won;Choi, Hyo-Sang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.4
    • /
    • pp.30-34
    • /
    • 2016
  • In this study, a SFCL-combined DC circuit breaker system was proposed by applying the current-limiting technology for DC circuit breaking. The SFCL-combined circuit breaker system consists of a mechanical DC circuit breaker combined with superconductors. To ensure the reliable structure and operation of the SFCL-combined circuit breaker system, a simulation grid was designed using the EMTDC/PSCAD program, and simulation was conducted. The results showed that the SFCL-combined DC circuit breaker system with superconductors limited the maximum fault current by 37%. In addition, the burden on the DC circuit breaker was decreased by 87%.

The Study About Low Voltage Circuit Breaker Mix Method Between IEC Circuit Breaker and Domestic Circuit Breaker (저압용 IEC 차단기와 국내 차단기 혼용방안에 관한 연구)

  • Jung, Jin-Soo;Kim, Han-Sang;Han, Woon-Ki;Kim, Sun-Gu;Park, Chan-Eom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.905-909
    • /
    • 2012
  • Recent WTO/TBT agreement was adopted by the IEC domestic. For this reason, low voltage electrical equipment was many Confusion arises. Low voltage circuit was also one of these. The case of low voltage circuit, existing domestic circuit breakers and circuit breakers IEC curve differs from the behavior of each other. If low voltage circuit breaker wrong facility, circuit breaker malfunction may occur due to the large property damage. In this paper, to solve these problems domestic circuit breakers and circuit breaker operation IEC curves were analyzed. And, through experiments suggested compatible breaker way.

A Study On the Analysis Of Impact Strain for Hydraulic Breaker Chisel (유압식 착암기 치즐의 타격 변형량 해석에 관한 연구)

  • Park, J.W.;Lee, K.W.;Kim, H.E.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.4
    • /
    • pp.21-27
    • /
    • 2007
  • A hydraulic breaker for construction machinery generally used for the destroying and disassembling of buildings, crashing road pavement, breaking rocks at quarry and so on. So the measurement of the impact energy of a hydraulic breaker is very important thing to prove its capability to manufacturers and customers. Therefore the prediction of impact energy in design process is very helpful to the most of breaker manufacturers. In this study, we carried on modeling and simulation of a hydraulic breaker to predict impact energy via commercial CAE software. The modeling and simulation of a hydraulic breaker was achieved with two parts. One is a hydraulic circuit analysis part via AMESim and the other is impact strain analysis part via ANSYS.

  • PDF

DC Superconducting fault current limiter characteristic test with a DC circuit breaker

  • So, Jooyeong;Choi, Kyeongdal;Lee, Ji-kwang;Kim, Woo-Seok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.2
    • /
    • pp.19-23
    • /
    • 2021
  • We have studied the breaking system that combines a resistive superconducting fault current limiter (SFCL) and a DC circuit breaker for DC fault current. To verify the design of the 15 kV DC SFCL, which was driven from the previous work, a 500 V DC system was built and a scale-down SFCL were manufactured. The manufactured SFCL module was designed as a bifilar coil which is a structure that minimizes inductive reactance. The manufactured SFCL module has been experiment to verify characteristics of the current-limiting performance in the DC 500 V system. Also, the manufactured FCL module was combined with the DC circuit breaker to be experimented to analyze the breaking performance. As a result of the experiment, when SFCL was combined to the DC circuit breaker, the energy dissipation received by the DC circuit breaker was reduced by up to 84% compared to when the DC circuit breaker operates alone. We are preparing methods and experiments for the optimal method for much higher performance as a future work.

Optimization ova Mechanism for Power Transfer Breakers (전력변환차단기의 트리거 기구 최적화)

  • 조두현;김권희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.735-739
    • /
    • 2002
  • PTB(Power Transfer Breaker) is a device which incorporate the functions of ACB(Air Circuit Breaker) and ATS(Automatic Transfer Switch). ACB is a circuit breaker against overload and ATS is a switching device to transfer the load between two electric power sources. An existing PTB design based upon the 5 bar & cam mechanism has been regarded to be too complex and thus a simpler 4 bar mechanism with trigger lock is proposed. Experimentation and optimization of the trigger lock is presented.

  • PDF

Analysis of Operation Characteristics of DC Circuit Breaker with Superconducting Current Limiting Element (초전도 전류제한소자를 적용한 DC 차단기의 동작 특성 분석)

  • Jung, Byung-Ik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1069-1074
    • /
    • 2020
  • Since DC has no zero point, an arc occurs when the DC circuit breaker performs a shutdown operation. In this case, a fatal accident may occur in the circuit breaker or in the grid, depending on the magnitude of the arc. Therefore, the shutdown performance and the reliability of the circuit breaker are important in the commercialization of HVDC. In this study, a superconducting LC circuit breaker was proposed to improve the performance and the reliability of the DC circuit breaker. The superconducting LC circuit breaker applied a superconducting coil to the inductor of the existing LC circuit breaker. Other than limiting the initial fault current, it also creates a stable zero point in the event of a fault current. To verify this, simulation was performed through EMTDC/PSCAD. Furthermore, the superconducting LC circuit breaker was compared with the LC circuit breaker with a normal coil. As a result, it was found that the LC circuit breaker with the superconducting coil limited the initial fault current further by approximately 12 kA compared to the LC circuit breaker with a normal coil. This reduced the arc extinguish time by approximately 0.16 sec, thereby decreasing the elctrical power burden on the circuit breaker.

A Study on the Structure Improvement of Bracket Housing for Structural Noise and Vibration Reduction in Hydraulic Breaker (유압 브레이커의 구조 소음.진동 저감을 위한 브래킷 하우징의 구조 개선에 관한 연구)

  • Kim, Bong-Suk;Kim, Min-Gi;Byun, Dong-Woo;Lee, Seong-Min;Lee, Soo-Hun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.11 s.188
    • /
    • pp.108-115
    • /
    • 2006
  • A hydraulic breaker is widely utilized for many civil engineering areas for the purpose of destroying objects such as rocks, concrete, or road. However, since the high-level noise and vibration by a hydraulic breaker is one of the major sources of environmental noise and recently the environmental regulations on construction equipments are also getting more strengthened, in order to solve such problems, it is certainly necessary to design and develop a hydraulic breaker with low noise and low vibration. This research is to understand the noise characteristics through the noise test and acoustic analysis of the bracket housing in a hydraulic breaker and to identify the element part to be modified based on the result of the element contribution analysis. An improved breaker model including X-typed rib shows the result of low-noise level within target frequency band compared with a commercial breaker model.