• 제목/요약/키워드: breakdown

검색결과 4,092건 처리시간 0.032초

Statistical Analysis of Electrical Tree Inception Voltage, Breakdown Voltage and Tree Breakdown Time Data of Unsaturated Polyester Resin

  • Ahmad, Mohd Hafizi;Bashir, Nouruddeen;Ahmad, Hussein;Piah, Mohamed Afendi Mohamed;Abdul-Malek, Zulkurnain;Yusof, Fadhilah
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.840-849
    • /
    • 2013
  • This paper presents a statistical approach to analyze electrical tree inception voltage, electrical tree breakdown voltage and tree breakdown time of unsaturated polyester resin subjected to AC voltage. The aim of this work was to show that Weibull and lognormal distribution may not be the most suitable distributions for analysis of electrical treeing data. In this paper, an investigation of statistical distributions of electrical tree inception voltage, electrical tree breakdown voltage and breakdown time data was performed on 108 leaf-like specimen samples. Revelations from the test results showed that Johnson SB distribution is the best fit for electrical tree inception voltage and tree breakdown time data while electrical tree breakdown voltage data is best suited with Wakeby distribution. The fitting step was performed by means of Anderson-Darling (AD) Goodness-of-fit test (GOF). Based on the fitting results of tree inception voltage, tree breakdown time and tree breakdown voltage data, Johnson SB and Wakeby exhibit the lowest error value respectively compared to Weibull and lognormal.

Experimental Research on Impulse Breakdown Characteristics of Soil

  • Lee, Jaebok;Sughun Chang;Sungho Myung;Yuengue Cho
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권2호
    • /
    • pp.60-63
    • /
    • 2004
  • The electrical breakdown characteristics of different types of soil samples have been measured. It is shown that the threshold soil breakdown strength is affected by many factors, such as types of soil, grain size, and soil compaction. The breakdown process in the test soil samples appears to be due to air ionization in the voids between the soil particles. The results have been compared with the relevant experimental results of other researchers.

AC Electrical Breakdown Characteristics of an Epoxy/Mica Composite

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권4호
    • /
    • pp.200-203
    • /
    • 2012
  • Epoxy/mica composite was synthesized, in order to use it as an impregnation resin in a vacuum pressure impregnation (VPI) process, for manufacturing a high voltage rotary machine. The average particle size of the mica was 5~7 ${\mu}m$ and its content was 0, 20, 30 and 40 wt%. A plasticizer or a low molecular aliphatic epoxy was also used, to decrease the viscosity of the composite. The AC electrical breakdown strength was estimated in sphere-to-sphere electrodes, and the electrical breakdown data were estimated by Weibull statistical analysis. The electrical breakdown strength became higher with the addition of mica; and that of the system with 20 wt% mica was highest. The electrical breakdown strength of the system with an aliphatic epoxy was higher than that of the system with a, plasticizer.

Electrical Breakdown Properties of Oil-paper Insulation under Pulsating Voltage Influenced by Temperature

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1735-1743
    • /
    • 2016
  • Insulation of valve-side windings in converter transformer withstands pulsating voltages, which will produce more serious insulation problems. In this paper, the electric breakdown experiments of oil-paper insulation specimens were executed at pulsating voltages and different temperatures. Experiment and analysis results showed that the breakdown voltage decreased with increasing temperature under pulsating voltage. The influence of temperature proves to be more significant once the temperature exceeds a limitation threshold. A fitting formula between breakdown voltage and the temperature was reported. Finally, in order to clearly understand the breakdown properties under pulsating voltage, the electric field distribution and space charge behavior under pulsating voltage at different temperature were discussed.

충진제와 실란처리에 따른 에폭시 복합체의 파괴시간 예측 (An Estimation of Breakdown Time of the Epoxy Composites according to Filler and Silane Treatment)

  • 신철기
    • 한국전기전자재료학회논문지
    • /
    • 제20권9호
    • /
    • pp.793-797
    • /
    • 2007
  • In this paper, the long time breakdown characteristic of the epoxy composite, which is widely used in the insulation system for high voltage application, was estimated with Weibull distribution. In the procedure of the estimation, the short time breakdown characteristics for the epoxy composite specimens, which were made with the variation of hardener and/or filler, were tested firstly. Then the long time voltage-to-time test was implemented. Finally, the long time breakdown voltage of each specimen was estimated with the parameters obtained from the statistical treatment with Weibull distribution. Base on the results, it has been found that the optimal weight ratio of epoxy resin/hardener/filler that has the excellent long time breakdown characteristic was 100/100/65. It was due to the silane treatment which relieves the electric field at the interface between filler and epoxy.

직접회로용 NPN BJT의 베이스-컬렉터간 역방향 항복전압 추출 알고리즘 (The Algorithm for Calculating the Base-Collector Breakdown Voltage of NPN BJT for Integrated Circuits)

  • 이은구;김철성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권2호
    • /
    • pp.67-73
    • /
    • 2003
  • The algorithm (or calculating the base-collector breakdown voltage of NPN BJT(Bipolar Junction Transistor) for integrated circuits is Proposed. The method for calculating the electric field using the solution of Poisson's equation is presented and the method for calculating the breakdown voltage using the integration of ionization coefficients is presented. The base-collector breakdown voltage of NPN BJT using 20V process obtained from the proposed method shows an averaged relative error of 8.0% compared with the measured data and the base-collector breakdown voltage of NPN BJT using 30V process shows an averaged relative error of 4.3% compared with the measured data

Laser CVD절연막의 전기전도와 절연파괴특성 (The eletrical conduction and breakdown characteristics of thin films by Laser CVD)

  • 강희복;권봉제;김용우;김성진;성영권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.191-193
    • /
    • 1991
  • In this paper, we introduce silicon dioxide films deposited by Laser CVD, and evaluate the breakdown characteristics of these films by TZDB(Time Zero Dieiectric Breakdown) and TDDB(Time Dependent Dielectric Breakdown) test, failure times against eletric field are examined and accelation factors ${\beta}$ are obtained, and also, long term reliability is described by examining TDDB under positive voltage bias, all the above results are compared with PECVD(Plasma Enhanced CVD) $SiO_2$ breakdown, data, as a result, it is shown that the breakdown characteristics of Laser CVD $SiO_2$ films is improved.

  • PDF

Effects of Reactive Diluents on the Electrical Insulation Breakdown Strength and Mechanical Properties in an Epoxy System

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권4호
    • /
    • pp.199-202
    • /
    • 2013
  • In order to study the effect of reactive diluents on the electrical insulation breakdown strength and mechanical properties of, a polyglycol and an aliphatic epoxy were individually introduced to an epoxy system. Reactive diluents were used in order to decrease the viscosity of the epoxy system; polyglycol acted as a flexibilizer and 1,4-butanediol diglycidyl ether (BDGE) acted as an aliphatic epoxy, which then acted as a chain extender after curing reaction. The ac electrical breakdown strength was estimated in sphere-to-sphere electrodes and the electrical breakdown strength was estimated by Weibull statistical analysis. The scale parameters of the electrical breakdown strengths for the epoxy resin, epoxy-polyglycol, and epoxy-BDGE were 45.0, 46.2, and 45.1 kV/mm, respectively. The flexural and tensile strengths for epoxy-BDGE were lower than those of the epoxy resin and those for epoxy-polyglycol were lower than those of the epoxy resin.

전기설비용 PET의 절연파괴와 공간전하효과에 관한 연구 (A Study on the Effect of Space Charge and tole Dielectric Breakdown of PEF for Electric Installation)

  • 윤성도;박상현;정학수;서장수;박중순;국상훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1992년도 추계학술발표회논문집
    • /
    • pp.37-40
    • /
    • 1992
  • This paper examined the existance behavior of charged particles by measuring polarity inversion current Thermal Stimulate Current (TSC) and analysed appearance mechanism of polarity inversion current Peak and Also investigated relation between ionic space charge format ion and dielectric breakdown by measuring D.C breakdown impulse breakdown D.C - impulse superposition as a sample of FET. As a result. lie found that dielectric breakdown is likely to happen due to ionic space charge at the transient state when applied polarity inversion voltage and that charged partion of TSE Peak at the high temperature was the same as that of polarity inversion current. Also there was no effect on ionic space charge about the dielectric breakdown in stationary state when applied D.C voltage.

  • PDF

와이블 분포식을 이용한 에폭시 복합체의 절연 신뢰도 분석 (Analysis of Insulating Reliability in Epoxy Composites using Weibull Distribution Equation)

  • Park, No-Bong;Lim, Jung-Kwan;Park, Yong-Pil
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.813-816
    • /
    • 2003
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were applied to Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased, the stronger breakdown strength became at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher. Finally, according to Weibull distribution analysis, reducing breakdown probability of equipment insulation lower than 0.1 % level requires the allowable field intensity values to be kept under 21.5 MV/cm.

  • PDF