• Title/Summary/Keyword: breakage

Search Result 830, Processing Time 0.035 seconds

Statistical Evaluation for Residual Strength of Impacted Composite Materials (충격손상 복합재료의 잔류강도저하거동에 대한 통계적 평가)

  • Kang, Ki-Weon;Lee, Seung-Pyo;Lee, Jin-Soo;Koh, Byung-Kab
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.426-434
    • /
    • 2010
  • This study is experimentally performed to evaluate the strength reduction behavior and its statistical properties of plain woven glass/epoxy composites. The results indicate that the major impact damage of plain woven glass/epoxy composites is the fiber breakage and matrix crack, whereas the dominant impact damage of unidirectional carbon/epoxy laminates is the delamination, which depends on the stacking sequence. The residual strength prediction models, previously proposed on unidirectional laminates, are applied to evaluate the residual strength of plain woven glass/epoxy composites with impact damage. Among these models, the results by Caprino and Avva's model have a good agreement with the experimental results. To investigate the variability of residual strength of the impacted composite materials, a statistical model was proposed and its results were in conformance with the experimental results regardless of their thickness.

Effects of Boron Supplementation to Diets Deficient in Calcium and Phosphorus on Performance with Some Serum, Bone and Fecal Characteristics of Broiler Chickens

  • Bozkurt, Mehmet;Kucukyilmaz, Kamil;Catli, Abdullah Ugur;Cinar, Mustafa;Cabuk, Metin;Bintas, Erol
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.2
    • /
    • pp.248-255
    • /
    • 2012
  • Three levels of boron (0, 30, 60 ppm) were supplemented in practical corn-soybean based starter and grower diets, containing either adequate or inadequate Ca or P. A total of 1,800, 1-day-old sexed broiler chicks were assigned to six dietary treatments and fed with the experimental diets for 42 days. Boron improved the overall feed conversion ratio, but increased body weight only at 21 days of age (p<0.01). Boron decreased feed intake in the case of feeding on a diet deficient in Ca and P, and tended to increase feed intake when birds received a diet adequate in Ca and P, signifying significant boron by Ca-P interaction (p<0.01). Mortality was not influenced by boron (p>0.05). Dietary Ca and P deprivation reduced body weight and feed consumption significantly, but did not influence the feed conversion ratio and mortality (p>0.05). Serum Ca level, ALP and ALT activities were not influenced either by dietary Ca and P deficiency or boron supplementation. Serum P content increased with respect to boron at 30 ppm. Bone breakage strength was not affected by dietary variables. Tibia ash, Ca and P were increased in response to the supplementation diet with 30 ppm boron, whereas 60 ppm showed no effect in most cases. Accordingly, the dietary boron supplementation of 30 ppm significantly decreased fecal Ca and P excretion, while there was a numerical decline in the 60 ppm boron as compared to the 0 ppm boron group. Data presented herein indicated that boron, either at the 30 ppm or 60 ppm supplementation level, was effective in conversion of feed to body weight, whereas only boron at 30 ppm contributed to the mineralization of bone thereby augmenting more Ca and P while excreting less through faeces.

Arthroscopic Treatment of Fractures of the Intercondylar Eminence of the Tibia Using Pull-Out Wire (견인강선을 이용한 경골극 견열 골절의 관절경적 치료)

  • Kim, Hyun Kon;Kim, Sung Jae;Hahn, Myung Hoon;Kang, Yong Ho;Jung, Hwan Yong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.45-50
    • /
    • 1998
  • Recently, a variety of arthroscopic techniques have been reported for the treatment of the displaced tibial eminence fracture. The purpose of this study was to describe details of arthroscopic technique using pull-out wire and to evaluate the results. Eleven patients with irreducible type II and type III tibial eminence fractures underwent the arthroscopic reduction and internal fixation using double strand pull-out wiring. The anterior cruciate ligament tibial drill guide was utilized for the reduction of fracture and passage of the guide pins. The tibial eminence fracture was firmly fixed with double strand 26-gauge pull-out wire(0.45mm diameter). Fracture union was achieved at 7.2 weeks (range, six to eight weeks) after operation. All cases were united at the last follow-up. Subjectively, nine patients had no pain and no restriction of daily activities. Two patients with combined injuries had limitation of knee motion(10 to 130 degrees, respectively) and one patient showed mild anterior laxity. Early rehabilitation was enabled without loss of reduction and breakage of pull-out wire. The arthroscopic reduction and internal fixation using pull-out wire showed good results including early rehabilitation, early fracture union, minimal morbidity, and no requirement of the second operation for hard ware removal.

  • PDF

Appropriate In Vitro Methods for Genotoxicity Testing of Silver Nanoparticles

  • Kim, Ha Ryong;Park, Yong Joo;Shin, Da Young;Oh, Seung Min;Chung, Kyu Hyuck
    • Environmental Analysis Health and Toxicology
    • /
    • v.28
    • /
    • pp.3.1-3.8
    • /
    • 2013
  • Objectives We investigated the genotoxic effects of 40-59 nm silver nanoparticles (Ag-NPs) by bacterial reverse mutation assay (Ames test), in vitro comet assay and micronucleus (MN) assay. In particular, we directly compared the effect of cytochalasin B (cytoB) and rat liver homogenate (S9 mix) in the formation of MN by Ag-NPs. Methods Before testing, we confirmed that Ag-NPs were completely dispersed in the experimental medium by sonication (three times in 1 minute) and filtration ($0.2{\mu}m$ pore size filter), and then we measured their size in a zeta potential analyzer. After that the genotoxicity were measured and especially, S9 mix and with and without cytoB were compared one another in MN assay. Results Ames test using Salmonella typhimurium TA98, TA100, TA1535 and TA1537 strains revealed that Ag-NPs with or without S9 mix did not display a mutagenic effect. The genotoxicity of Ag-NPs was also evaluated in a mammalian cell system using Chinese hamster ovary cells. The results revealed that Ag-NPs stimulated DNA breakage and MN formation with or without S9 mix in a dose-dependent manner (from $0.01{\mu}g/mL$ to $10{\mu}g/mL$). In particular, MN induction was affected by cytoB. Conclusions All of our findings, with the exception of the Ames test results, indicate that Ag-NPs show genotoxic effects in mammalian cell system. In addition, present study suggests the potential error due to use of cytoB in genotoxic test of nanoparticles.

Cytogenetic evaluation of a patient with ring chromosome 9 presenting failure to thrive and developmental delay (성장부진과 발달지연을 보인 환아에서 확인된 환상 9번 염색체 1례의 세포유전학적인 연구)

  • Park, Yun Mi;Nho, Han Nae;Kim, Sook Za;Ahn, Young Min
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.426-430
    • /
    • 2008
  • We report clinical, cytogenetic, and fluorescence in situ hybridization (FISH) studies of a patient with ring chromosome 9. She presented with failure to thrive, facial dysmorphysm and mild psychomotor development delay in the absence of major malformations. Peripheral blood karyotype of the patient was 46,XX,r(9)(p24q34). G-band analysis suggested no loss of material in the ring chromosomes. FISH analysis using the subtelomere-specific sequences on chromosome 9p and 9q, revealed 46,XX,r(9)(p24q34),ish r(9)(D9S913-,D9S325+). Failure to detect any hybridization of a probe for the subtelomeric sequences in the ring 9p terminal suggested that this ring arose from breakage in the distal short arm. The cytogenetic and FISH data in our case provided further evidence for the existence of a "complete ring" phenotype with incomplete subtelomeric sequences.

Posterior Atlantoaxial Transarticular Screw Fixation

  • Ko, Byung-Su;Lee, Jung-Kil;Kim, Yeon-Seong;Moon, Sung-Jun;Kim, Jae-Hyoo;Kim, Soo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.3
    • /
    • pp.179-183
    • /
    • 2007
  • Objective : Posterior arthrodesis in atlantoaxial instability has been performed using various posterior C1-2 wiring techniques. Recently, transarticular screw fixation (TASF) technique was introduced to achieve significant immediate stability of the C1-2 joint complex. The purpose of this study is to assess the clinical outcomes associated with posterior C1-2 TASF for the patient of atlantoaxial instability. Methods : We retrospectively reviewed data obtained from 17 patients who underwent C1-2 TASF and supplemented Posterior wiring technique (PWT) with graft between 1994 and 2005. There were 8 men and 9 women with a mean age of 43.5 years (range, 12-65 years). An average follow-up was 26 months (range, 15-108 months). Results : Successful fusions were achieved in 16 of 17 (94%). The pain was improved markedly (3 patients) or resolved completely (14 patients). There was no case of neurological deterioration, hypoglossal nerve injury, or vertebral artery injury. Progression of spinal deformity, screw pullout or breakage, and neurological or vascular complications did not occur. Conclusion : The C1-2 TASF with supplemental wiring provided a high fusion rate. Our result demonstrates that C1-2 TASF supplemented by PWT is a safe and effective procedure for atlantoaxial instability. Preoperative evaluation and planning is mandatory for optimal safety.

Short-segment Pedicle Instrumentation of Thoracolumbar Burst-compression Fractures; Short Term Follow-up Results

  • Shin, Tae-Sob;Kim, Hyun-Woo;Park, Keung-Suk;Kim, Jae-Myung;Jung, Chul-Ku
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.265-270
    • /
    • 2007
  • Objective : The current literature implies that the use of short-segment pedicle screw fixation for spinal fractures is dangerous and inappropriate because of its high failure rate, but favorable results have been reported. The purpose of this study is to report the short term results of thoracolumbar burst and compression fractures treated with short-segment pedicle instrumentation. Methods : A retrospective review of all surgically managed thoracolumbar fractures during six years were performed. The 19 surgically managed patients were instrumented by the short-segment technique. Patients' charts, operation notes, preoperative and postoperative radiographs (sagittal index, sagittal plane kyphosis, anterior body compression, vertebral kyphosis, regional kyphosis), computed tomography scans, neurological findings (Frankel functional classification), and follow-up records up to 12-month follow-up were reviewed. Results : No patients showed an increase in neurological deficit. A statistically significant difference existed between the patients preoperative, postoperative and follow-up sagittal index, sagittal plane kyphosis, anterior body compression, vertebral kyphosis and regional kyphosis. One screw pullout resulted in kyphotic angulation, one screw was misplaced and one patient suffered angulation of the proximal segment on follow-up, but these findings were not related to the radiographic findings. Significant bending of screws or hardware breakage were not encountered. Conclusion : Although long term follow-up evaluation needs to verified, the short term follow-up results suggest a favorable outcome for short-segment instrumentation. When applied to patients with isolated spinal fractures who were cooperative with 3-4 months of spinal bracing, short-segment pedicle screw fixation using the posterior approach seems to provide satisfactory result.

A Time Domain Analysis of Moored Ship Motions with Resonant Period of a Tsunami (쓰나미의 공진주기파를 고려한 항내 계류선박의 시계열 해석)

  • Cho Ik-Soon;Lee Yun-Sok;Lee Choong-Ro
    • Journal of Navigation and Port Research
    • /
    • v.30 no.6 s.112
    • /
    • pp.433-438
    • /
    • 2006
  • Recently, the earth scale disaster is occurring frequently. Under the effects of global warming, the weather has become unseasonable worldwide. Hence, the earth is experiencing unstable condition with many disasters such as storms and flood damages as well as earthquake. Therefore, it is necessary to consider what we am do to prevent disasters. Consequently, recent warnings indicate that there is a potential risk of massive earthquakes. Consideration of the effects of tsunami to the moored ship is very important. Operational problems such as moored ship motions sometimes become remarkable with large amplitude and long periods in harbor. Moored ship motions may cause the breakage of mooring systems such as mooring lines, fenders or quay. Large and long period moored ship motions are caused by resonant effects. In this paper, the moored ship motions within a harbor by the large-scale tsunami and the effects on the motions and mooring loads with resonant effects are investigated by numerical simulations.

Mechanism study on DNA damage and Apoptosis induced by heak shock using Comet Assay

  • Seo, Young-Rok;Han, Sung-Sik;Kim, L. O′Neill;Ryu, Jae-Chun
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 1997.12a
    • /
    • pp.101-101
    • /
    • 1997
  • Comet assay, single cell gel electrophoresis has been known as useful, rapid, simple, visual, and sensitive technique for measuring the DNA breakage in mammalian ce1ls. For evaluation of DNA damage using comet assay, early studies reported a change in comet length and intensity with DNA damage using simple visual technique, such as fluorescence microscopy with eyespiece. In recent, some workers are observing and analyzing nucleotide of comets using quantitative fluorescence image analysis system to estimate 'tail moment', which is defined as the product of the tail length and the fraction of total DNA in tail. Our laboratory also adopted the image analysis software for qualification. In addition, many of the practical features of comet assay render it potentially attractive as useful tool for molecular toxicology and carcinogenesis, because the system is already showing considerable promise as rapid predictor in both in vitro and in vivo experimental designs. Recently, the comet assay becomes a attractive technique to study of apoptosis, because apoptotic fragmentation of nuclear DNA into nucleosomal sizes can be evaluated by the comet assay. So, we attempted to apply the comet assay to studying the effect of various stress on the apoptosis-sensitive cell lines. Particularly, focusing on the hyperthermic apoptosis, we could find that heat shock(44˚C for 60 minutes) was sufficient to induced apoptosis in these cell lines. But using the highly sensitive comet assay, we could not detect DNA breaks immediately after heat shock.

  • PDF

Analysis of Train Delay in Daejeon Metro (대전도시철도의 열차 지연운행 분석연구)

  • Kwon, Young-Seok;Lee, Jin-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.1
    • /
    • pp.50-57
    • /
    • 2017
  • This study investigated the causes and problems of train operation impediments through the statistics analysis of 8 years'internal data of Daejeon Metropolitan Express Transit. By evaluating the risks regarding the system, equipment, and parts of high risk group, this study measured the Risk Index Severity, and applied the $5{\times}5$ Risk Assessment Matrix which is a method of risk management to calculate the scale of risk to analyze the safety level and allowance range. As a result, the car sector, the most serious risk, followed by machinery and equipment sector showed that the inherent risk. In particular, the door broken and the door rail signaling and control devices due to defects of the vehicle is high, but also the severity, and frequency are showing very frequent additional potential accidents. PSD also had defects in the machinery sector appeared to be the most dangerous of the PSD poor safety gates, it was found that the glass also involve the risk of mishandling and breakage of the PSD. This study intended to contribute to the transportation benefits through the safety and stable operation of Metropolitan Express Transit.