• Title/Summary/Keyword: break-down voltage

Search Result 74, Processing Time 0.027 seconds

Dielectric Breakdown and Electric Stress Distribution in Ferroelectrics (강유전체에서의 전계분포 및 절연파괴)

  • 신병철;김호기
    • Journal of the Korean Ceramic Society
    • /
    • v.24 no.4
    • /
    • pp.392-396
    • /
    • 1987
  • Pure barium titanate was sintered at $1340^{\circ}C$ for 2, 4, 8, 16 hr to control their grain size. The measurements of breakdown strength and partial discharge characteristics were performed under rising AC voltage(60Hz). With increase of sintering time, the average grain size was increased and breakdown strength was slightly decreased. Partial discharge in pores was observed under high voltage, and a model of dielectric break down in barium titanate ceramics is proposed.

  • PDF

Considerations on correlation between partial discharge and breakdown using void-simulated defect (보이드 모의결함을 이용한 부분방전과 절연파괴와의 상관관계에 대한 고찰)

  • Lee, Tae-Seong;Jang, Su-Gil;Kim, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.21-22
    • /
    • 2011
  • In this paper, considerations on correlation between partial discharge and breakdown using void-simulated defect, investigating the characteristics of void discharges. For the purpose, the relationship between PDIV(Partial Discharge Inception Voltage) and BDV(BreakDown Voltage) was analyzed. As a result, it is noticed that the higher PDIV, the higer BDV.

  • PDF

Dielectric Breakdown Voltage and Dielectric Properties of High Voltage Mutilayer Ceramic Capacitor with C0G Temperature Coefficient Characteristics (C0G 온도계수 특성을 가지는 고압용 적층 칩 캐패시티의 유전 및 내전압 특성)

  • Yoon, Jung-Rag;Woo, Byong-Chul;Chung, Tae-Serk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.2
    • /
    • pp.137-143
    • /
    • 2008
  • High voltage MLCCs with C0G temperature coefficient characteristics could apply DC-DC invertor were investigated for its dielectric properties. Also we manufactured MLCC through various process and studied the characteristics of dielectric break down voltage [BDV] and dielectric property as the variation of thickness in the green sheet and how to pattern the internal electrode. As the thickness of green sheet is increase, the dielectric BDV per unit thickness is decreased. But as the pattern of internal electrodes were floated we could manufacture the high voltage MLCC maintained its dielectric BDV a unit.

Design of Snubber for the AVR to supply Excitor (여자기 공급용 AVR의 Snubber 설계)

  • Oh, Sang-Rok;Lee, Cheol-Seung;Ryu, Ho-Sun;Seong, Se-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.313-315
    • /
    • 1994
  • In this paper, it is consider spike voltage that is generated by ignoring the recovery time of switching device, turn on and turn off time. In the same principle, this spike voltage will be applicable to diode recovery time. The spike voltage causes to break down insulation of input transformer. So, we will show how to remove spike voltage by optimizing value of R and C and using switching diode which have fast recovery time.

  • PDF

The Effect of Metallic Barrier on the Surface creeping Flash-over Voltage along the Insulation Materials (절연물의 연면섬락 전압에 미치는 금속 격벽의 영향)

  • Sung Kae Chung
    • 전기의세계
    • /
    • v.14 no.2
    • /
    • pp.8-13
    • /
    • 1965
  • It is expected that the impurities contained in a solid state insulation material will affect a considerable influence on its break-down voltage, dielectric loss, and insulation resistance. In this thesis, as a preliminary experimental research for the investigation described above, the effect of metalic barrier between the electrodes on the creepin flash over discharge voltage along the surface of a solid insulation material has been investigated, and got some interesting results. It was found that generaly the flash over voltage rises when a metalic barrier is located between the electrodes. The results of this investigation will be taken into account as an important components on the insulation design to prevent the creeping flash over discharge in insulators, bushings, and so on.

  • PDF

A Study on the Insulation Characteristics of Low-Voltage Induction Motor driven by IGBT PWM Inverter (IGBT 인버터 구동 저압 유도전동기의 절연특성 연구)

  • Hwang, D.H.;Park, D.Y.;Kim, Y.J.;Koo, J.Y.;Park, T.I.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.206-210
    • /
    • 1999
  • Since the introduction of IGBT PWM inverters, many low-voltage induction motors have been driven by them. Recently, the stator winding insulation failures have attracted much concern due to high dv/dt of IGBT inverter output. In this paper, presented are the detailed insulation test results of 26 low-voltage induction motors. Six different types of insulation techniques are applied to 26 motors. The tests include PD, $tan{\delta}$, and DIV tests. Also, break-down tests by high voltage pulses are performed.

  • PDF

Insulation Coordination of Forced Drainage in Electric Railway (직류방식 전기철도에서 강제배류기의 절연협조)

  • Min, B.H.;Eo, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.446-448
    • /
    • 1999
  • The forced drainage set up to decrease the cathodic protection in each kind of steel conduit laid under the ground is so proscribed to be maintained less than 60V in its output voltage that insulation coordination is easy to be left out of account, on the basis of 60V of working voltage. When railway or subway break down during the service of a subway, 1,500 voltage approximating to line voltage flows through the load terminal of the drainage (rail and underground conduit) though momentary in the worst case. And so, an accident followed by dielectric breakdown, fire and damage by a fire is expected. Therefore, I suggest that insulation coordination should be considered against such a thing on designing, producing and setting up forced drainage.

  • PDF

Effects of switching power supply on input transformer (스위칭 전원장치가 입력변압기에 미치는 영향)

  • Oh, Sang-Rok;Kim, Byung-Kweon;Seong, Se-Jin;Lee, Heung-Ho;Han, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.815-817
    • /
    • 1993
  • In this paper, it is considered spike voltage that is generated by ignoring the recovery time of switching device, turn on and turn off time. In the same principle, this spike voltage will be applicable to diode recovery time. The spike voltage causes to break down insulation of input transformer. So, we will show how to remove spike voltage by optimizing value of R and C and using switching diode which have fast recovery time.

  • PDF

전력설비용 Polyethlene의 열자극 표면전위법에 의한 공간저하 측정에 관한 연구

  • 이경섭;국상훈
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.63-67
    • /
    • 1990
  • Many characteristics of space charge in insulating materials which is the cause of insulation break down was measured quantita-tively. It was confirmed that injection charge of the electrode was trapped to form mainly space charge. In the present paper, collecting potential was determined by TSSP and mean depths of space distribution was investigated by measuring variation quantity of space charge under the different bias time, voltage and temperature. Experimental resuts was in good agreement with model analysis on a stedy state.

  • PDF