• 제목/요약/키워드: break-down voltage

검색결과 74건 처리시간 0.027초

강유전체에서의 전계분포 및 절연파괴 (Dielectric Breakdown and Electric Stress Distribution in Ferroelectrics)

  • 신병철;김호기
    • 한국세라믹학회지
    • /
    • 제24권4호
    • /
    • pp.392-396
    • /
    • 1987
  • Pure barium titanate was sintered at $1340^{\circ}C$ for 2, 4, 8, 16 hr to control their grain size. The measurements of breakdown strength and partial discharge characteristics were performed under rising AC voltage(60Hz). With increase of sintering time, the average grain size was increased and breakdown strength was slightly decreased. Partial discharge in pores was observed under high voltage, and a model of dielectric break down in barium titanate ceramics is proposed.

  • PDF

보이드 모의결함을 이용한 부분방전과 절연파괴와의 상관관계에 대한 고찰 (Considerations on correlation between partial discharge and breakdown using void-simulated defect)

  • 이태성;장수길;김정태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.21-22
    • /
    • 2011
  • In this paper, considerations on correlation between partial discharge and breakdown using void-simulated defect, investigating the characteristics of void discharges. For the purpose, the relationship between PDIV(Partial Discharge Inception Voltage) and BDV(BreakDown Voltage) was analyzed. As a result, it is noticed that the higher PDIV, the higer BDV.

  • PDF

C0G 온도계수 특성을 가지는 고압용 적층 칩 캐패시티의 유전 및 내전압 특성 (Dielectric Breakdown Voltage and Dielectric Properties of High Voltage Mutilayer Ceramic Capacitor with C0G Temperature Coefficient Characteristics)

  • 윤중락;우병철;정태석
    • 한국전기전자재료학회논문지
    • /
    • 제21권2호
    • /
    • pp.137-143
    • /
    • 2008
  • High voltage MLCCs with C0G temperature coefficient characteristics could apply DC-DC invertor were investigated for its dielectric properties. Also we manufactured MLCC through various process and studied the characteristics of dielectric break down voltage [BDV] and dielectric property as the variation of thickness in the green sheet and how to pattern the internal electrode. As the thickness of green sheet is increase, the dielectric BDV per unit thickness is decreased. But as the pattern of internal electrodes were floated we could manufacture the high voltage MLCC maintained its dielectric BDV a unit.

여자기 공급용 AVR의 Snubber 설계 (Design of Snubber for the AVR to supply Excitor)

  • 오상록;이철승;류호선;성세진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.313-315
    • /
    • 1994
  • In this paper, it is consider spike voltage that is generated by ignoring the recovery time of switching device, turn on and turn off time. In the same principle, this spike voltage will be applicable to diode recovery time. The spike voltage causes to break down insulation of input transformer. So, we will show how to remove spike voltage by optimizing value of R and C and using switching diode which have fast recovery time.

  • PDF

절연물의 연면섬락 전압에 미치는 금속 격벽의 영향 (The Effect of Metallic Barrier on the Surface creeping Flash-over Voltage along the Insulation Materials)

  • 정성계
    • 전기의세계
    • /
    • 제14권2호
    • /
    • pp.8-13
    • /
    • 1965
  • It is expected that the impurities contained in a solid state insulation material will affect a considerable influence on its break-down voltage, dielectric loss, and insulation resistance. In this thesis, as a preliminary experimental research for the investigation described above, the effect of metalic barrier between the electrodes on the creepin flash over discharge voltage along the surface of a solid insulation material has been investigated, and got some interesting results. It was found that generaly the flash over voltage rises when a metalic barrier is located between the electrodes. The results of this investigation will be taken into account as an important components on the insulation design to prevent the creeping flash over discharge in insulators, bushings, and so on.

  • PDF

IGBT 인버터 구동 저압 유도전동기의 절연특성 연구 (A Study on the Insulation Characteristics of Low-Voltage Induction Motor driven by IGBT PWM Inverter)

  • 황돈하;박도영;김용주;구자윤;박태익;김진홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.206-210
    • /
    • 1999
  • Since the introduction of IGBT PWM inverters, many low-voltage induction motors have been driven by them. Recently, the stator winding insulation failures have attracted much concern due to high dv/dt of IGBT inverter output. In this paper, presented are the detailed insulation test results of 26 low-voltage induction motors. Six different types of insulation techniques are applied to 26 motors. The tests include PD, $tan{\delta}$, and DIV tests. Also, break-down tests by high voltage pulses are performed.

  • PDF

직류방식 전기철도에서 강제배류기의 절연협조 (Insulation Coordination of Forced Drainage in Electric Railway)

  • 민병훈;어익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.446-448
    • /
    • 1999
  • The forced drainage set up to decrease the cathodic protection in each kind of steel conduit laid under the ground is so proscribed to be maintained less than 60V in its output voltage that insulation coordination is easy to be left out of account, on the basis of 60V of working voltage. When railway or subway break down during the service of a subway, 1,500 voltage approximating to line voltage flows through the load terminal of the drainage (rail and underground conduit) though momentary in the worst case. And so, an accident followed by dielectric breakdown, fire and damage by a fire is expected. Therefore, I suggest that insulation coordination should be considered against such a thing on designing, producing and setting up forced drainage.

  • PDF

스위칭 전원장치가 입력변압기에 미치는 영향 (Effects of switching power supply on input transformer)

  • 오상록;김병권;성세진;이흥호;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.815-817
    • /
    • 1993
  • In this paper, it is considered spike voltage that is generated by ignoring the recovery time of switching device, turn on and turn off time. In the same principle, this spike voltage will be applicable to diode recovery time. The spike voltage causes to break down insulation of input transformer. So, we will show how to remove spike voltage by optimizing value of R and C and using switching diode which have fast recovery time.

  • PDF

전력설비용 Polyethlene의 열자극 표면전위법에 의한 공간저하 측정에 관한 연구

  • 이경섭;국상훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1990년도 추계학술발표회논문집
    • /
    • pp.63-67
    • /
    • 1990
  • Many characteristics of space charge in insulating materials which is the cause of insulation break down was measured quantita-tively. It was confirmed that injection charge of the electrode was trapped to form mainly space charge. In the present paper, collecting potential was determined by TSSP and mean depths of space distribution was investigated by measuring variation quantity of space charge under the different bias time, voltage and temperature. Experimental resuts was in good agreement with model analysis on a stedy state.

  • PDF