• Title/Summary/Keyword: branch-switching

Search Result 61, Processing Time 0.037 seconds

Crosstalk-Enhanced DOS Integrated with Modified Radiation-Type Attenuators

  • Han, Young-Tak;Shin, Jang-Uk;Park, Sang-Ho;Han, Sang-Pil;Lee, Chul-Hee;Noh, Young-Ouk;Lee, Hyung-Jong;Baek, Yong-Soon
    • ETRI Journal
    • /
    • v.30 no.5
    • /
    • pp.744-746
    • /
    • 2008
  • This letter presents a crosstalk-enhanced polymer thermo-optic digital optical switch operating at a low power consumption. Modified radiation-type attenuators are integrated in a series with a conventional $1{\times}2$ digital optical switch. A low optical crosstalk of less than -45 dB is attained at a low applied switching power of 60 mW, and an insertion loss of about 1.1 dB is exhibited.

  • PDF

Quantitative identification of the fluxon-flow modes in a stack of intrinsic Josephson junctions of $Bi_2$$Sr_2$Ca$Cu_2$$O_{8+x}$ single crystals

  • Bae, Myung-Ho;Lee, Hu-Jong
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.9-12
    • /
    • 2003
  • We observed the splitting of the fluxon-flow branches in the current-voltage characteristics of serially stacked intrinsic Josephson junctions (IJJs) formed in $Bi_2$$Sr_2$$CaCu_2$$O_{ 8+x}$ single crystals in the long-junction limit. Stacks of IJJs were sandwiched between two Au electrodes deposited on the top and the bottom of the stack using the ‘double-side cleaving technique’. In all the samples studied, the branch splitting started occurring for a dense fluxon configuration around 2 T and became more distinct in a higher magnetic field range. This observation can be explained in terms of switching between different Josephson fluxon modes in resonance with the collective plasma oscillations induced by both inductive and capacitive coupling between stacked IJJs. This is the first detailed and quantitative identification of the coherent flux-flow modes in stacked..

  • PDF

Analysis of Current Fed Full Bridge DC-DC Converter with Active Clamp (능동 클램프형 전류형 단상 풀브리지 DC-DC 컨버터의 동작 해석)

  • Cha, Han-Ju;Choi, Soon-Ho;Ahn, Chi-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.205-207
    • /
    • 2007
  • Isolated Current fed full-bridge converter with active clamp is analyzed in this paper. An active clamp branch is used for limiting the voltage overshoot in the bridge switches and rectifier diodes. Zero voltage switching(ZVS) is also realized by using the energy stored in the transformer leakage inductance. To analyze the converter, 6 modes of operation are introduced and investigated. For each of the modes, voltage and current equations are derived together with corresponding equivalent circuits. 200W prototype dc-dc converter is assembled and verifies the effectiveness of the analysis and simulation.

  • PDF

Service Restorative System in Emergency State using Object-Oriented Structure (객체구조를 이용한 긴급상태 정전복부 시스템)

  • Kim, Jeong-Nyeon;Baek, Yeong-Sik
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.1
    • /
    • pp.1-5
    • /
    • 2000
  • This paper presents a new algorithm to restore the de-energized loads in electric power distribution systems for restoration by utilizing object-based structure and heuristic rules without branch and feeder overloading. In order to cope with a complex network configuration and frequent breaker switching operations in distribution systems, the component of power system is described as objects and the information of system configuration is constructed by connecting objects each other. Such a strategy is developed mainly based on the object search algorithm to increase computation efficiency. As a result, the proposed system has been implemented to efficiently deal with large distribution systems by reducing computational burden remarkably compared with the conventional methods.

  • PDF

High Performance Polymeric Optical Waveguide Devices (고성능 폴리머 광도파로 소자)

  • O, Min-Cheol;No, Yeong-Uk;Lee, Hyeong-Jong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2005.02a
    • /
    • pp.292-295
    • /
    • 2005
  • Variable optical attenuators (VOA) made of low-loss fluorinated polymers are demonstrated which shows a low operating power less than 30 mW due to the superior thermo-optic effect of polymer material and a low insertion loss less than 1.0 dB by incorporating highly fluorinated polymers to reduce the absorption loss at 1550 nm. An attenuator-integrated low-crosstalk polymeric digital optical switch (DOS) is also demonstrated. The switch and attenuator shares a single connected electrode which is controlled by a single current source. Due to the simple structure of the integrated attenuator, the device length is reduced to 1 cm so as to provide low insertion loss of 0.8 and 1.1 dB for 1300 and 1550 nm, respectively. The attenuator radiates remained optical signal on the switch-off branch in order to decrease the switching crosstalk to be less than -70 dB with an applied electrical power of 200 mW.

  • PDF

Analysis of electro-optic polymer digital optical switch with a coupling region modified for optimum mode coupling (최적의 모드 결합을 얻기 위해 수정된 결합 영역을 갖는 전기광학 폴리머 디지탈 광스위치의 해석)

  • 이상신;신상영
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.4
    • /
    • pp.87-93
    • /
    • 1997
  • An electro-optic polymer digital optical switch with a coupling region modified for optimum mode coupling is proposed, and it is analyzed by using the beam propagation method combined with the effective index method. Its modified coupling region is adiabatically introduced along the propagation direction from the branching point of the two waveguides. The structure of the modified coupling region and its refractive index profiles are designed to optimize the mode coupling in the Y-branch waveguide. Therefor, the switching performance of the device may be enhanced with a fixed device length. It is confirmed from the numerical calculation that the drive voltage is reduced by more than 30 percents and te crosstalk is improved by about 8dB.

  • PDF

A study on the Optimal Operation of Distirbution System Using the Modified Block Model Method (수정블럭 모델 법에 의한 배전계통의 최적운용에 관한 연구)

  • 송길영;홍상은;김재영
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.4
    • /
    • pp.231-239
    • /
    • 1987
  • Distribution system is one of large and complicated sytem, consisted of a great number of components. Therefore efficient operation based on precise analysis and computation methods is indispensable accommodating growing loads. This paper describes an optimal operation problem to relieve overload flow in radial distribution systems by using modified block model. The problem is formulated as a network problem of synthesizing the optimal spanning tree in a graph, branch and bound method is used for the optimization. Especially modified block model proposed in this paper is validated more practical than conventional model. These methods can be applied to two types of distribution system problems such as, 1) planning problem to check the capability of relieving overload at normal rating, 2) emergency operation problem to determine switching scheme for minimizing customer loads affected by a fault. Examples of application to these problems are discussed.

  • PDF

Active Front End Inverter with Quasi - resonance

  • Siebel, Henrik;Pacas, J.M.
    • Journal of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.17-23
    • /
    • 2003
  • A new three-phase soft-switching active front-end inverter is presented. The topology consists of a quasi-resonant PWM boost converter with an additional resonant branch, which provides low loss at high frequency operation. This leads to a high conversion efficiency and a remarkable reduction in the siBe of the input inductor. To synchronise the PWM pattern with the resonance cycle, a modified space vector modulation with asymmetrical PWM pattern is used. A high power factor can be achieved for both power flow directions. Due to a new control strategy the converter features a low content of harmonics in the line currents even for distorted line voltages.

An Improved Service Restoration Algorithm under Consideration of Abnormal Conditions in Distribution Automation Systems

  • Cho, Namhun;Kim, Insung;Lee, Sungwoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.47-54
    • /
    • 2015
  • The most important function in distribution automation system (DAS) is the service restoration. KEPCO's current service restoration provides a very effective restoration service. However, it has been developed without the consideration of unexpected abnormal conditions that may occur while processing the sequence of switching operations. The objective of this paper is to provide practical service restoration schemes under consideration of abnormal conditions. The proposed service restoration schemes have been integrated to a branch office (B/O) in KEPCO. The proposed method strongly supports the conventional service restoration and adds to its value.

Active front end inverter with quasi - resonance

  • Siebel H.;Pacas J. M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.146-150
    • /
    • 2001
  • A new three-phase soft-switching active front-end inverter is presented. The topology consists of a quasi-resonant PWM boost converter with an additional resonant branch, which provides low loss at high frequency operation. This leads to a high conversion efficiency and a remarkable reduction in the size of the input inductor. To synchronise the PWM pattern with the resonance cycle, a modified space vector modulation with asymmetrical PWM pattern is used. A high power factor can be achieved for both power flow directions. Due to a new control strategy the converter features a low content of harmonics in the line currents even for distorted line voltages.

  • PDF