• 제목/요약/키워드: brachytherapy phantom

검색결과 35건 처리시간 0.041초

Intracavitary Ultrasound Hyperthermia Applicators for Gynecological Cancer

  • Lee, Rena J. .;Suh, Hyun-Suk
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.53-53
    • /
    • 2003
  • For evaluating the feasibility of treating recurrent lesions in the vaginal cuff and cervix by hyperthermia, ultrasound applicators were designed, constructed, and characterized. For the treatment A half-cylindrical transducer Cd=1cm, length=lcm) and cylindrical transducer (d=2.5cm, length= 1.5cm) were used to construct ovoid type and cylindrical applicators. For the ovoid type applicator, each element was operated at 1.5MHz and characterized by measuring transducer efficiency and acoustic power distribution. Thermocouple probes were used to measure the temperature rise in phantom. The element sizes used in this study were selected to be comparable for high dose rate brachytherapy colpostat applicator. Each element was powered separately to achieve a desired temperature pattern in a target. The acoustic output power as a function of applied electric power of the element 1 and 2 was linear over this 1 to 40 W range and efficiencies were 32.2${\pm}$3.4% and 46.2${\pm}$0.8%, respectively. The temperature measurements in phantom showed that 6$^{\circ}C$ temperature rise was achieved at 2 cm from the applicator surface. As a conclusion, the ability of the ultrasound colpostat applicator to be used for hyperthermia was demonstrated by measuring acoustic output power, ultrasound field distribution, and temperature rise in phantom. Based on the characteristics of this applicator, it has the potential to be useful for inducing hyperthermnia to the vaginal cuff in clinic.

  • PDF

근접치료용 하나로 생산 Ir-192 선원의 임상기기 적합성평가용 팬톰개발 (Development of Phantom for Evaluate the Suitability of Ir-192 HDR Source with Brachytherapy Tools)

  • 신교철;최상규;김기환;손광재;정동혁;김정기
    • 한국의학물리학회지:의학물리
    • /
    • 제24권3호
    • /
    • pp.171-175
    • /
    • 2013
  • 본 연구에서는 한국원자력연구원(KAERI)에서 하나로(HANARO) 원자로를 통하여 새로이 개발한 근접치료용 Ir-192 선원의 기기적 안정성과 기존에 사용되는 근접치료기와의 호환성을 평가하기 위한 팬톰을 개발하고 임상기기 적합성 평가를 실험하였다. 다양한 근접치료용 어플리케이터와 선원의 적합성 결과는 일정한 비율의 곡률의 변화에 대해서는 반경 2.2~2.7 cm 범위에서 정상작동 하였고 급격한 힘의 변화를 고려한 경우에서는 반경 1.5~1.8 cm 범위에서 정상작동 할 수 있음을 확인하였다. 어플리케이터의 모양변화에 따른 선원의 머무름 시간 오차의 평가에서는 선원이 도달 가능한 점까지 에서는 거의 변화가 없어 보였다. 근접방사선치료를 위해 사용되어지는 방사선 선원은 그 크기가 작고 종양의 다양한 모양과 위치에 안정적으로 도달될 수 있어야 한다. 이와 같은 기기적 안정성을 평가하기 위해 본 연구에서 설계 고안된 기기적 안정성 평가 팬톰은 선원의 굴곡의 최적 조건을 평가하는데 유효하다고 생각되며, 한국원자력연구원에서 개발된 근접치료용 Ir-192 선원의 기기적 안정성시험결과 기존의 사용되어지는 수입산 선원과 차이가 없음을 확인할 수 있었다.

자궁주위 방사선 근접치료시 MIRD 팬텀을 이용한 주변장기의 피폭환경평가 (Assessment of Dose Distribution using the MIRD Phantom at Uterine Cervix and Surrounding Organs in High Doserate Brachytheraphy)

  • 이윤종;노영창;이재기
    • 환경생물
    • /
    • 제24권4호
    • /
    • pp.387-391
    • /
    • 2006
  • Manchester system 타입의 장착기중 상, 하부에 차폐체가 장착되어 있는 Henschke 장착기를 이용하여 자궁암 근접치료시 자궁 및 주변장기의 선량분포를 평가하기 위하여 치료계획수립에 사용되는 실용프로그램 결과와 몬테칼로 모의계산 결과를 비교하였다. 또한 자궁 및 주변 정상조직이 받은 선량을 계산하기 위해 ORNL(Oak Ridge National Laboratory)에서 수립한 여성의 MIRD (Medical Internal Radiation Dose)형 모의피폭체를 이용 하여 주변장기가 받는 선량을 MCNP로 계산하였다. 몬테칼로 모사에는 MCNP 4B코드를 사용하였으며, 실용계산프로그램에는 GAMMADOT를 이용하였다 MCNP계산에는 $^{192}Ir$ 선원과 장착기의 기하학적 모양을 정밀하게 모사하여 계산 오차를 줄이도록 하였으며, 치료계획용 실용계산프로그램의 계산 조건과 동일하게 치료선원의 강내 체류시간과 체류위치를 적용하여 선량을 계산하였다. 주요 선량 비교 평가점은 Manchester system에서 사용되는 4곳과 ICRU 38에서 Manchester system을 보완하기 위해 제시한 방광표면 및 직장이였다. 실용계산 결과는 MCNP모의계산의 결과와 비교했을 때 대부분 위치에서 상대오차 4% 이내의 결과를 보였고, 난형체의 차폐체 장착효과로 인한 방광과 직장에서의 선량감쇠효과는 각각 19%, 20%였다.

방사선 근접치료에 있어서 핵자기공명영상을 이용한 3차원 방사선 선량분포도의 가시화를 위한 polymer 젤의 이용 (The Use of Polymer Gel for the Visualization of 3-D Dose Distribution in Brachytherapy Using Magnetic Resonance Imaging)

  • 강해진;조삼주;정은기;강승희;오영택;전미선;권수일
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.207-215
    • /
    • 1998
  • 방사선의 측정방법으로 현재까지 여러 방법들이 쓰여져 왔다. 여기에는 필름을 이용하는 방법, TLD를 이용하는 방법, 전리함(ion chamber)을 이용하는 방법 등이 대체로 가장 많이 쓰여지는 방법이다. 그러나 본 연구에서는 새로운 방사선측정 방법이 시도되었다. 고분자 젤과 핵자기공명영상 (MRI)을 이용한 방법이 그 것이다. 본 연구의 목적은 방사선 측정을 위한 고분자 젤을 합성하고 합성된 젤을 사용하여 젤의 방사선 흡수선량과의 관계를 MRI 영상으로부터 구해서, 이 결과를 근접치료에 쓰이는 seed 선원의 선량분포를 측정하여 가시화 시키는데 있다. 이를 위해 지름 12 cm 원통형 팬텀에 젤을 합성하고, 이 젤을 뇌정위 방사선수술에 쓰이는 30 mm 콜리메이터를 이용하여 여러 단계의 선량을 젤에 조사하였다. 이렇게 조사된 젤은 MRI 을 촬영하였고 이렇게 촬영된 MRI 영상으로부터 젤팬텀의 각 위치의 횡이완시간 (T$_2$ time)을 영상분석 소프트웨어를 이용하여 계산하였다. 그 결과 젤의 홉수선량과 횡이완시간과는 17 Gy 근처까지는 거의 반비례 ($R^2$=0.993)하는 것을 알 수 있었으며, 이 보다 높은 흡수선량에 대해서는 또 다른 관계가 있음을 알 수 있었다. 또 이것을 이용하여 HDR afterloading system 의 Ir-192 seed 선원에 의한 선량분포와 2 mCi Ir-192 seed 선원에 의한 선량분포를 측정하였다. 그리고 이 것을 각각 치료계획컴퓨터에 의한 선량분포곡선과 비교하였다. 본 연구의 결과로는 고분자 젤을 이용한 방사선의 측정방법을 시도하여 홉수선량과 젤의 특성과의 관계를 밝혔으며, 실제로 그접치료에 쓰이는 seed 선원에 의한 선량분포 곡선을 얻는데 적용하였다.

  • PDF

전립선암의 근접치료 시 이식환자에 근접한 사람의 선량평가 (Dose Evaluation of the Man Adjacent to an Implanted Patient During the Prostate Cancer Brachytherapy)

  • 박은태;김정훈
    • 한국방사선학회논문지
    • /
    • 제10권1호
    • /
    • pp.39-44
    • /
    • 2016
  • 본 연구는 전립선암의 치료방법 중 근접치료 시 환자 주변의 공간에 대한 선량을 평가한 것으로 환자, 시술자 그리고 보호자에 대한 선량을 예측함으로서 피폭을 최소한으로 예방하고자 수행하였다. 실험방법은 몬테칼로법을 기반으로 한 MCNPX를 사용하여 가상의 공간에서 모의피폭체를 만들어 실험하였으며, 선원은 $^{192}Ir$, $^{125}I$, $^{103}Pd$를 seed 형태로 이식하였다. 환자를 중심으로 전방 30, 50, 100, 200 cm 거리에 관심영역을 설정하여 공간 선량을 평가하였다. 그 결과 거리에 관계없이 $^{192}Ir$에서 가장 높은 선량을 나타내었다.

Development of PC-based Radiation Therapy Planning System

  • Suh, Tae-Suk;P task group, R-T
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.121-122
    • /
    • 2002
  • The main principle of radiation therapy is to deliver optimum dose to tumor to increase tumor cure probability while minimizing dose to critical normal structure to reduce complications. RTP system is required for proper dose plan in radiation therapy treatment. The main goal of this research is to develop dose model for photon, electron, and brachytherapy, and to display dose distribution on patient images with optimum process. The main items developed in this research includes: (l) user requirements and quality control; analysis of user requirement in RTP, networking between RTP and relevant equipment, quality control using phantom for clinical application (2) dose model in RTP; photon, electron, brachytherapy, modifying dose model (3) image processing and 3D visualization; 2D image processing, auto contouring, image reconstruction, 3D visualization (4) object modeling and graphic user interface; development of total software structure, step-by-step planning procedure, window design and user-interface. Our final product show strong capability for routine and advance RTP planning.

  • PDF

근접방사선치료용 다목적 팬톰을 이용한 직장 내 선량분석 (The Analysis of Dose in a Rectum by Multipurpose Brachytherapy Phantom)

  • 허현도;김성훈;조삼주;이석;신동오;권수일;김헌정;김우철;노준규
    • Radiation Oncology Journal
    • /
    • 제23권4호
    • /
    • pp.223-229
    • /
    • 2005
  • 목적: 근접방사선 치료시 직장내 선량측정은 치료간(Inter-fraction) 직장의 형태가 변화하므로 측정의 재현성을 이룰 수 없다. 본 연구에서는 근접방사선치료용 다목적 팬톰(Multi Purpose Brachytherapy Phantom, MPBP)을 제작하여 치료 시와 동일한 조건을 재현하였고 이때 측정한 선량 값을 직장의 부작용을 줄이기 위해 선량최적화에 적용하고자 하였다. 대상 및 방법: 자궁경부암 근접방사선 치료 시 탄뎀(tandem)과 난형체(ovoid)를 사용한 환자 4명을 대상으로 다이오드 검출기를 이용하여 직장표시 기준점 R1에서 선량측정을 시행하였다. 환자 당 5회씩 총 20회 직장선량을 측정하였다. 그리고 반복 측정 시 다이오드 검출기의 설정 변화(set up variation)를 분석하였다. 그리고 자체 제작된 근접방사선치료용 다목적 팬톰에서 MFA (Multi Function Applicator)를 이용하여 치료 시와 동일한 조건을 재현한 후 열형광선량계(TLD)를 이용하여 직장 표시 기준점 좌표 위치에서 선량을 측정하였다. 결과: 직장 내 다이오드 검출기의 측정 결과 설정 변화는 환자 1의 경우에 Y방향에서 최고 $11.25{\pm}0.95mm$보였고, 환자 2와 3은 Z 방향에서 각각 $9.90{\pm}4.50mm$$20.85{\pm}4.50mm$를 나타냈다. 그리고 환자 4는 Z 방향에서 $19.15{\pm}3.33mm$의 변화를 나타내었다. 또한 다이오드 검출기 위치에 따른 평균선량 값은 $122.82{\pm}7.96cGy{\sim}323.78{\pm}11.16cGy$로 나타났다. MPBP에서 TLD의 측정 결과는 직장 표시 기준점(R1)에서 환자1과 4는 상대오차가 각각 최고 8.6%와 7.7%를 보였고, 환자2와 3은 각각 1.7%와 1.2%의 오차를 보였다. 그리고 R과 R2에서 측정한 선량 값들은 환자 2의 R 지점을 제외하고 계산값과 비교하여 $1.7{\sim}8.6%$ 높은 값을 나타냈다. 그리고 반복측정으로 인한 위치변화와 그에 따른 선량 값의 변화는 분석하지 않았다. 계산 값과 측정값의 상대오차가 미국의학물리학회 보고서에서 권고한 15% 내에서 잘 일치하는 것으로 분석되었다. 결론: 자체 제작된 근접치료용 다목적 팬톰(MPBP)은 치료 시와 동일한 조건에서 선량측정의 재현성을 이룰 수 있었고, 직장의 기준점에서 선량을 정확히 분석할 수 있었다. 또한 팬톰에서 측정한 데이터를 이용하여 직장의 부작용을 줄이기 위해 치료 전 선량 최적화를 이루는데 충분한 자료로 활용할 수 있다고 판단되었다.

전립선암 근접시료시 주변 장기 선량 평가 (Radiation Dose Calculation in the Surrounding Organs during Brachytherapy of Prostate Cancer)

  • 김정훈;임창선;황주호
    • 한국의학물리학회지:의학물리
    • /
    • 제19권3호
    • /
    • pp.172-177
    • /
    • 2008
  • 정량적인 방사선치료 선량을 예측하기위한 일환으로 한국표준남성에 기초하여 수학적 모의피폭체를 제작하였다. 이후 전립선을 선원장기로 하여 전립선암 근접치료 시 발생할 것으로 예상되는 전립선 및 주변장기의 흡수선량을 산정하였다. 모의모사를 위하여 방사성핵종은 전립선 근접치료에 유용하게 사용되는 $^{25}I$$^{103}Pd$선정하였고, 초기 방사능을 1 Ci를 투여하는 것으로 가정하였다. 그 결과 선원장기인 전립선이 $^{125}I$$^{103}Pd$ 경우 각각 101 Gy/Ci와 7.24 Gy/Ci를 나타냈으며, 전립선을 제외하고 흡수선량이 높은 장기는 비교적 전립선과 인접되어 있는 장기 즉 음경과 음낭, S자결장, 정소, 방광순으로 나타났다.

  • PDF

Evaluation of Dosimetric Effect and Treatment Time by Plan Parameters for Endobronchial Brachytherapy

  • Choi, Chang Heon;Park, Jong Min;Park, So-Yeon;Kang, SungHee;Cho, Jin Dong;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제28권2호
    • /
    • pp.39-44
    • /
    • 2017
  • This study aims to analyze dose distribution and treatment time of endobronchial brachytherapy (EBBT) by changing the position step size of the dwell position. A solid water phantom and an intraluminal catheter were used in the treatment plan. The treatment plans were generated for 3, 5, 7, and 10 cm treatment lengths, respectively. For each treatment length, the source position step sizes were set as 2.5, 5, and 10 mm. Three reference points were set 1 cm away from the central axis of the catheter, along the axis, for uniform dose distribution. Volumetric dose distribution was calculated to evaluate the dosimetric effect. The total radiation delivery time and total dwell time were estimated for treatment efficiency, which were increased with position step sizes. At half-life time, the differences between the position step sizes in the total radiation delivery time were 18.1, 15.4, 18.0, and 24.0 s for 3, 5, 7, and 10 cm treatment lengths, respectively. The dose distributions were more homogenous by increasing the position step sizes. The dose difference of the reference point was less than 10%. In brachytherapy, this difference can be negligible. For EBBT, the treatment time is the key factor while considering the patient status. To reduce the total treatment time, EBBT can be performed with 2.5 mm position step size.