This study is fulfilled to evaluate the exposure dose nearby a patient during the brachytherapy of the prostate cancer treatment and to minimize the radiation exposure by evaluating the exposure dose of the person near the relevant implanted patient, technicians and gardians. The experiment method is used on the study is MCNPX that is stood on the basis monte-carlo method and implant the source to MIRD-type phantom in $^{192}Ir$, $^{125}I$, and $^{103}Pd$ in virtual space. For dose evaluations according to distance, the radiation dose on the patient near the corresponding implanted patient is evaluated by each distance of 30, 50, 100, 200 cm to anterior from the implanted patient. As a result, $^{192}Ir$ showed a higher dose than $^{125}I$ and $^{103}Pd$ in every distance.

본 연구는 전립선암의 치료방법 중 근접치료 시 환자 주변의 공간에 대한 선량을 평가한 것으로 환자, 시술자 그리고 보호자에 대한 선량을 예측함으로서 피폭을 최소한으로 예방하고자 수행하였다. 실험방법은 몬테칼로법을 기반으로 한 MCNPX를 사용하여 가상의 공간에서 모의피폭체를 만들어 실험하였으며, 선원은 $^{192}Ir$, $^{125}I$, $^{103}Pd$를 seed 형태로 이식하였다. 환자를 중심으로 전방 30, 50, 100, 200 cm 거리에 관심영역을 설정하여 공간 선량을 평가하였다. 그 결과 거리에 관계없이 $^{192}Ir$에서 가장 높은 선량을 나타내었다.

Keywords

References

  1. Ministry of Health & Welfare, "Annual report of cancer statistics in Korea in 2013," Korea, 2015.
  2. W. Park, S. J. Huh, H. H. Choi, H. M. Lee, S. E. Chai, Y. C. Ahn, D. H. Lim, "Results of Definitive Radiotherapy in the Treatment of Prostate Cancer," The Korean Urological Association, Vol. 46, No. 3, pp. 201-228, 2005.
  3. S. S. Kang, I. H. Go, G. J. Kim, S. H. Kim, Y. S. Kim, Y. J. Kim, Radiation Therapeutics, third edition, Chung-ku munhwasa, Korea, 2014.
  4. International Commission on Radiological Protection, "Radiation Safety Aspects of Brachy therapy for Prostate Cancer using Permanently Implanted Sources," ICRP Publication 98, Pergamon Press, Oxford, UK, 2005.
  5. T. P. Arthur, C. B. John, D. G. Peter, M. R. Sarada, R. Haakon, "Brachy therapy for Prostate Cancer," CA-A Cancer Journal for Clinicians, Vol. 45, pp. 165-178, 1995. https://doi.org/10.3322/canjclin.45.3.165
  6. S. Saito, T. Momma, T. Dokiya, M. Murai, "Brachytherapy for Prostate Cancer in Japan," International Journal of Urology, Vol. 8, pp. 22-27, 2001. https://doi.org/10.1046/j.1442-2042.2001.00330.x
  7. M. M. Oh, Y. W. Bahk, E. T. Scott, "Preliminary Report of Clinical Experience of Iodine-125 Seed Implant for Early Prostatic Cancer: The First Case in Korea," The Korean Urological Association, Vol. 42, No. 11, pp. 1235-1240, 2001.
  8. J. H. Kim, C. S. Lim, J. H. Whang, "Radiation Dose Calculation in the Surrounding Organs during Brachytherapy of Prostate Cancer," The Korean Society of Medical Physics, Vol. 19, No. 3, pp. 172-177, 2008.
  9. J. K. Park, S. H. LEE, S. Y. Cha, Y. S. Kim, S. Y. Lee, "Availability and Reproducibility Evaluation of High-dose-rate Intraluminal Brachytherapy for Unresectable Recurrent Cholangiocarcinoma," Journal of the Korean Society of Radiology, Vol. 6, No. 2, pp.151-157, 2012. https://doi.org/10.7742/jksr.2012.6.2.151
  10. F. M. KHAN, The Physics of Radiation Therapy 4/E, Lippincott Williams & Wilkins, 2009.
  11. LANL, User's manual version 2.5.0, Los Alamos National Laboratory, LA-CP-05-0369, 2005.
  12. H. L. Fisher, W. S. Snyder, "Distribution of dose in the body from a source of gamma rays distributed uniformly in an organ," Health Physics Division Annual Progress Report for Period Ending July 31, 1967 Report ORNL-4168 (Oak Ridge, TN: Oak Ridge National Laboratory), 1967.
  13. International Commission on Radiological Protection, "Basic Anatomical and Physiological Data for Use in Radiological Protection Reference Values," A report of ICRP Publication 89, Ann. ICRP 32 (3-4), 2002. https://doi.org/10.1016/S0146-6453(02)00021-0
  14. International Commission on Radiation Units and Measurements (1992c), "Photon, Electron, Proton and Neutron Interaction Data for Body Tissues," ICRU Report 46 (Bethesda, MD: ICRU), 1992.
  15. XU XG, "An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history," Physics in Medicine and Biology, Vol. 59, No. 18, pp.R 233-R302, 2014. https://doi.org/10.1088/0031-9155/59/18/R233
  16. J. S. LEE, "Dose Evaluation Using Mathematical Simulation of Radiation Exposure Body in Mammography System," Journal of the Korean Society of Radiology, Vol. 8, No. 4, pp. 155-161, 2014. https://doi.org/10.7742/jksr.2014.8.4.155
  17. J. H. Kim, C. S. Kim, J. H. Whang, "Assessment of Radiation Dose for Surrounding Organs and Persons Approaching Implanted Patients upon Brachytherapy of Prostate Cancer with Iridium-192," Radiation Protection Dosimetry, Vol. 141, No. 3, pp. 283-288, 2010. https://doi.org/10.1093/rpd/ncq181
  18. H. Cember, Introduction to Health Physics, Third edition, McGraw-Hill, New York, 1996.
  19. International Commission on Radiological Protection, "The 2007 Recommendations of the International Commission on Radiological Protection," ICRP Publication 103, 2007.

Cited by

  1. 전립선암의 근접치료 시 나노입자에 따른 흡수선량평가 vol.12, pp.2, 2016, https://doi.org/10.7742/jksr.2018.12.2.167