• Title/Summary/Keyword: box unit system

Search Result 86, Processing Time 0.027 seconds

Analysis on the Vibration Characteristics of Reduction Gear Units for High-speed Trains (고속철도차량 감속구동장치 진동특성 분석)

  • Moon, Kyung Ho;Lee, Dong-Hyong;Kim, Jae Chul;Ji, Hae Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.7
    • /
    • pp.694-701
    • /
    • 2013
  • The gear-reduction units of Korean high-speed trains consist of a motor reduction unit, an axle gear box reduction unit, and a tripod joint shaft. A reduction gear unit is a gearbox used to reduce the rotational speed of the input shaft to a slower rotational speed on the output shaft. This reduction in output speed helps to increase torque. Defective reduction gear units in high-speed trains are caused by damage to the gear or by gear fatigue. To diagnose potential problems, it is important to know the vibration characteristics of the reduction gear units. In this study, we analyzed the vibration characteristics of reduction gears under various conditions. The test setup included a full-scale test rig to evaluate reduction gear under both normal and extreme operating conditions.

Application of Recursive Least Squares Method to Estimate Rail Irregularities from an Inertial Measurement Unit on a Bogie (대차 관성측정 장치에서 궤도틀림 추정을 위한 반복 최소자승법의 적용)

  • Lee, Jun-Seok;Choi, Sung-Hoon;Kim, Sang-Soo;Park, Choon-Soo
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.427-434
    • /
    • 2011
  • This paper is focused on application of recursive least squares method to estimate rail irregularities from the acceleration measurement on an axle-box or a bogie for the rail condition monitoring with in-service high-speed trains. Generally, the rail condition was monitored by a special railway inspection vehicle but the monitoring method needs an expensive measurement system. A monitoring method using accelerometers on an axle-box or a bogie was already proposed in the previous study, and the displacement was successfully estimated from the acceleration data by using Kalman and frequency selective band-pass filters. However, it was found that the displacement included not only the rail irregularities but also phase delay of the applied filters, and effect of suspension of the bogie and conicity of the wheel. To identify the rail irregularities from the estimated displacement, a compensation filter method is proposed. The compensation filters are derived by using recursive least squares method with the estimated displacement as input and the measured rail irregularity as output. The estimated rail irregularities are compared with the true rail irregularity data from the rail inspection system. From the comparison, the proposed method is a useful tool for the measurement of lateral and vertical rail irregularity.

  • PDF

The Development of the Turbo-Generator System with direct driving High Speed Generator. (고속 발전기 직접 구동 방식의 터보 제너레이터 시스템 개발)

  • 노민식;권정혁;변지섭
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2769-2772
    • /
    • 2003
  • This paper presents results of the development of the Turbo-generator system with structure which is HSG(High Speed Generator) installed to high speed gas-turbine engine directly. Turbo-generator with high speed motor-generator directly has many advantages aspects of weight, size, lubrication system and complexity of the system compared of conventional turbo-generator system with gear-box. But because of direct high speed operation of the high speed generator, we have to need stable high speed motor driving algorithm for perfect engine ignition when gas turbine starting. Also we have to need design of the PCU(Power Conditioning Unit) for converting high speed AC output power to conventional AC power or needed DC power.

  • PDF

A Study on The Crime Prevention System Improvement of Seoul Metropolitan Police (서울 경찰(警察)의 방범체제(防犯體制) 개선(改善)에 관한 연구(硏究))

  • Lee, Sang-Won
    • Korean Security Journal
    • /
    • no.1
    • /
    • pp.175-208
    • /
    • 1997
  • I study the actual condition and the problem of the crime prevention system of two seoul police station. that is operated on the unit of police box, and present the new improvement. Stragic and active is the new crime prevention system that introduces a concept of community oriented policing, the tendency of a developed country police. I present a medium - sized police station where 250${\sim}$300 policemen work. It consist of a patrol division, a community division and a administration support division. The chief of police bears the responsibility only for crime prevention service by concentrating on pure Patrol - centered crime prevention activity and community relation activity. Next I present a police inspector system. The most important on this paper is the community policing officer system that a policeman bears responsibility on district apart from a patrol division and support a police service related community. To be operated these systems effectively, these need to be regulated according to a police distinct, a police purpose and it's demand. Also a scale, function, authority of a existing. Police station must be regulated and the police training must be carried out.

  • PDF

Implementation of Low-priced Bicycle Black Box Using 6-axis Sensor (6축 센서를 이용한 저가형 자전거 블랙박스 구현)

  • Weon, La-Kyoung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.5
    • /
    • pp.171-182
    • /
    • 2019
  • Bicycles are a pollution-free means of transportation. In addition to leisure, the use of bicycles is increasing as alternative eco-friendly transportation. Accordingly, bicycle accidents are also increasing. The purpose of this study is to implement bicycle black box technology to identify situation when a bicycle accident occurs. Currently, bicycle black box products are mainly based on video cameras, and are commercially available by adding various functions mainly on high resolution cameras and are sold at high prices. If a bicycle accident occurs, quantitative data on the accident location at the time of the accident and the state of the bicycle at the time of the accident is required. In this study, IMU sensor used to obtain acceleration and slope, and time and coordinates are obtained. In addition, real-time acceleration and tilt data while is stored in memory card and by using Bluetooth transmit to the smart phone owned by the in real time to prevent accidents and to monitor status.

Development and Performance Test of SOFC Co-generation System for RPG (SOFC를 이용한 가정용 열병합 발전시스템 개발 및 성능시험)

  • Lee, Tae-hee;Choi, Jin-Hyeok;Park, Tae-Sung;Choi, Ho-Yun;Yoo, Young-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.361-364
    • /
    • 2009
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 cells with $10{\times}10cm^2$ area and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water. Recently KEPRI developed stacks using $15{\times}15cm^2$ cells and tested them. KEPRI will develop a 5 kW class CHP system using $15{\times}15cm^2$ stacks by 2010.

  • PDF

Development and Performance of Automated Calibration System of Sound Level Meters (소음계 교정 자동화 시스템 개발 및 성능평가)

  • 김용태;조문재;이용봉;서재갑;서상준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.704-709
    • /
    • 1998
  • An automated calibration system of sound level meters was developed and tested. As a standard sound source, the speaker unit(Forstex FE208) cabineted by 440 * 390 * 490 mm$^{3}$(LHW) volume wood box was adopted. Including this source, the driving part was found out to have a good linearity of sound pressure output vs AC input. We use the Hybrid-Bisect, /Newton-Raphson method modified by the linearity as searching algorithm. Personal computer and program do the control, measurements, and calculations and finally do the accumulation of useful data and results. Several trials of automatic calibration using this developed system give reliable results.

  • PDF

Development and Performance of Automated Calibration System of Sound Level Meters (소음계 교정 자동화 시스템 개발 및 성능평가)

  • 김용태;조문재;이용봉;서재갑
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.879-886
    • /
    • 1998
  • An automated calibration system of sound level meters was developed and tested. As a standard sound source, the speaker unit(Forstex FE208) cabineted by 440$\times$390$\times$490 $\textrm{mm}^3$(LHW) volume wood box was adopted. Including this source, the driving part was found out to have a good linearity of sound pressure output vs AC voltage input. The Hybrid-Bisect/Newton-Raphson method modified by the linearity was adopted as a searching algorithm. Uisng GPIB interface, the console PC make the control, measurements, and calculations and finally make the accumulation of useful data and results automatically by the instructon in the program coded by C languate. Several trials of automatic calibration using this developed system give the reliable results.

  • PDF

Development of Integrated TCU for Multimedia Communication Devices Control (멀티미디어 통신기기 제어를 위한 통합 TCU 개발)

  • Lim, Yangmi;Kang, Namhi
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.1-6
    • /
    • 2014
  • Companies almost don't use an integrated control system using expensive network system in multimedia like TV and DID, despite IP-Broadcasting and communication equipment have expanded rapidly. The proposed integrated TCU(terminal control unit) is a control device that supports TV power On/Off check and remote control, power control reservation function, TV channel change, a variety of interface supports of input/output AC power & Lan port, RS-232C and IR using existing IP network after there is installed the Wake-on -Lan in the set-top box. The TCU can control and monitor 24 hours unlike existing low-cost control system RF method. In existing control equipment markets without expandability and low price, the TCU development including 24 hours monitoring and automatic control functions is expected to secure a wide range of companies.

Development of an insulation performance measurement unit for full-scale LNG cargo containment system using heat flow meter method

  • Lee, Jin-sung;Kim, Kyung-su;Kim, Yooil
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.4
    • /
    • pp.458-467
    • /
    • 2018
  • Efforts have been made in this paper to develop the measuring device for the insulation performance of full scale NO96 LNG CCS. The facility was designed to maintain environmental conditions which are similar to operation conditions of full scale LNG CCS. In the facility, the heat sink boundary was kept cryogenic temperature by cold chamber which contains liquefied nitrogen and heat source boundary was made by external case heated by natural convection. Heat Flow Meter method (HFM) was applied to this facility, hence Heat Flux Sensors (HFS) were attached to specimen. The equivalent thermal conductivity of full scale NO96 unit box was targeted to measure and PUF of same size was used for the calibration test. Additionally, the finite element analysis was carried out to check the performance of the developed test facility and experimental results were also compared with those predicted by the numerical method.