Natural time period equations for moment resisting reinforced concrete structures comprising hollow sections

  • Prajapati, Satya Sundar;Far, Harry;Aghayarzadeh, Mehdi
    • Computers and Concrete
    • /
    • 제26권4호
    • /
    • pp.317-325
    • /
    • 2020
  • A precise estimation of the natural time period of buildings improves design quality, causes a significant reduction of the buildings' weight, and eventually leads to a cost-effective design. In this study, in order to optimise the reinforced concrete frames design, some symmetrical and unsymmetrical buildings composed of solid and hollow members have been simulated using finite element software SAP 2000. In numerical models, different parameters such as overturning moment, story drift, deflection, base reactions, and stiffness of the buildings were investigated and the results have been compared with strength and serviceability limit criteria proposed by Australian Standard (AS 3600 2018). Comparing the results of the numerical modelling with existing standards and performing a cost analysis proved the merits of hollow box sections compared to solid sections. Finally, based on numerical simulation results, two equations for natural time period of moment resisting reinforced concrete buildings have been presented. Both derived equations reflected higher degree of correlation and reliability with different complexities of building when compared with existing standards and relationships provided by other scholars. Therefore, these equations will assist practicing engineers to predict elastic behaivour of structures more precisely.

Experimental study of rigid beam-to-box column connections with types of internal/external stiffeners

  • Rezaifar, Omid;Nazari, Mohammad;Gholhaki, Majid
    • Steel and Composite Structures
    • /
    • 제25권5호
    • /
    • pp.535-544
    • /
    • 2017
  • Box sections are symmetrical sections and they have high moment of inertia in both directions, therefore they are good members in tall building structures. For the rigid connection in structures with box column continuity plates are used on level of beam flanges in column. Assembly of the continuity plates is a difficult and unreliable work due to lack of weld or high welding and cutting in the fourth side of column in panel zone, so the use of experimental stiffeners have been considered by researchers. This paper presented an experimental investigation on connection in box columns. The proposed connection has been investigated in four cases which contain connection without internal and external stiffeners(C-0-00), connection with continuity plates(C-I-CP), connection with external vase shape stiffener (C-E-VP) and connection with surrounding plates(C-E-SP). The results show that the connections with vase plates and surrounding plates can respectively increase the ultimate strength of the connection up to 366% and 518% than the connection without stiffeners, in case connection with the continuity plates this parameter increases about 39%. In addition, the proposed C-E-VP and C-E-SP connection provide a rigid and safe connection to acquire rigidity of 95% and 98% respectively. But C-I-CP connection is classified as semi-rigid connections.

Progressive collapse analysis of two existing steel buildings using a linear static procedure

  • JalaliLarijani, Reza;Celikag, Murude;Aghayan, Iman;Kazemi, Mahdi
    • Structural Engineering and Mechanics
    • /
    • 제48권2호
    • /
    • pp.207-220
    • /
    • 2013
  • In this study, the vulnerability of two existing asymmetric steel building frames to Progressive Collapse (PC) is assessed. The buildings have different frame systems, steel sections and number of stories (nine and six). An alternate path method (APM) with a linear static analysis (LS) is carried out according to General Services Administration (GSA) 2003 guidelines. The Demand Capacity Ratio (DCR) of each primary element (beams and columns) is given with its specific details for all frames. The results show that the nine-story building with a dual frame system (moment frame with bracing system) has a lower susceptibility and greater resistance to PC than the six-story building with a simple building frame system (gravity system with bracing system). Implementing built-up box-shaped sections for columns is a better choice than using built-up I-shaped sections because there is no weak axis for the box section.

합성상형의 유한요소 해석 (Finite Element Analysis of the Composite Box Girder)

  • 이정기;조진구;박근수
    • 한국농공학회지
    • /
    • 제29권3호
    • /
    • pp.145-152
    • /
    • 1987
  • This paper suggests a method for the analysis of box girders which are subject to the membrane and the plate bending actions, Moreover, the method is applied to the box girders under distributed loads which have various geometrical types of cross sections and are made out of different materials. The approach is based on the finite element technique in which the structure is considered to be a spatial assemblage of flat plate elements and the deformations of the plates are to be approximated with 9-noded parabolic isoparametric elements. The results are summarized as follows. 1.In all models, the larger the widths of top flange inside of web are, the larger the vertical deflections are. 2.The maximum transverse and longitudinal moments in the composite box girders are judged to be larger than those in the RC box girders. 3.The transverse and the longitudinal moments in top flange of composite box. girders are larger than those in that of the RC box girders. 4.The transverse and longitudinal moments in web and bottom flange of the composite box girders are estimated to be very small in compare to those in web and bottom flange of the RC box girders.

  • PDF

Numerical investigations on the effect of mean incident wind on flutter onset of bridge deck sections

  • Keerthana, M.;Harikrishna, P.
    • Structural Engineering and Mechanics
    • /
    • 제82권4호
    • /
    • pp.517-542
    • /
    • 2022
  • The effect of mean angle of wind attack on the flutter critical wind speed of two generic bridge deck cross-sections, viz, one closed box type streamlined section (deck-1) and closed box trapezoidal bluff type section with extended flanges/overhangs (deck-2) type of section have been studied using Computational Fluid Dynamics (CFD) based forced vibration simulation method. Owing to the importance of the effect of the amplitude of forcing oscillation on the flutter onset, its effect on the flutter derivatives and flutter onset have been studied, especially at non-zero mean angles of wind attack. The flutter derivatives obtained have been used to evaluate flutter critical wind speeds and flutter index of the deck sections at non-zero mean angles of wind attack studied and the same have been validated with those based on experimental results reported in literature. The value of amplitude of forcing oscillation in torsional degree of freedom for CFD based simulations is suggested to be in the range of 0.5° to 2°, especially for bluff bridge deck sections. Early onset of flutter from numerical simulations, thereby conservative estimate of occurrence of instability has been observed from numerical simulations in case of bluff bridge deck section. The study aids in gaining confidence and the extent of applicability of CFD during early stages of bridge design, especially towards carrying out studies on mean incident wind effects.

Stability limit state design of box sections supporting mining and process facilities

  • Bedair, Osama
    • Structural Engineering and Mechanics
    • /
    • 제39권5호
    • /
    • pp.643-659
    • /
    • 2011
  • The design of box girders requires the determinations the buckling stress of the flange and the webs. Existing design equations available in codes of practice ignore the interactions between the box girder components. The paper illustrates the influence of the geometric interaction on the buckling stress of box girders. Generalized equations are first derived in terms of the web the flange geometric properties. Industrial examples are then presented showing the variation of the flange buckling stress for various stiffening configurations. The influence of the flange/web proportions on the buckling stress of box girder components is also highlighted. It is shown that buckling strength of the flange is largely affected by the restraints imposed by the webs or attached diaphragms. Graphs are presented showing various limiting states of box girders. These graphs are useful to use in practice in order to achieve economical and efficient design of box girders and rationally predict local buckling stress.

박스단면 고강도 트러스 기둥재의 좌굴거동 (The Buckling Behavior of High-strength Steel Truss Columns with Box Section)

  • 장갑철;장경호
    • 한국공간구조학회논문집
    • /
    • 제7권3호
    • /
    • pp.79-86
    • /
    • 2007
  • 최근, 건설되어지는 강구조물들의 장경간화 및 고층화로 인하여 고강도강재의 적용이 점차 요구되고 있다. 고강도강재는 적용구조물들을 공간 및 두께들 감소시킴으로써 외관성 및 경제성을 증가시킬 수 있는 장점이 있다. 이러한 고강도 강재의 적용을 위해서는 좌굴에 대한 기준이 필요하나 현재 국내의 경우 이러한 좌굴에 관한 연구가 미흡하다. 이에 본 연구에서는 3차원 탄소성 유한변위 프로그램을 이용하여 고강도 박스단면 트러스 부재의 좌굴거동에 대한 해석적 연구를 수행하였다. 고강도강재를 적용한 박스단면 트러스부재의 허용 압축응력에 대한 기준을 제안하였으며 그 적용성을 확인하였다. 그리고 고강도 트러스 부재의 설계에도 적용할 수 있음을 명확히 하였다.

  • PDF

Efficient cross-sectional profiling of built up CFS beams for improved flexural performance

  • Dar, M. Adil;Subramanian, N.;Atif, Mir;Dar, A.R.;Anbarasu, M.;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • 제34권3호
    • /
    • pp.333-345
    • /
    • 2020
  • In the past, many efficient profiles have been developed for cold-formed steel (CFS) members by judicious intermediate stiffening of the cross-sections, and they have shown improved structural performance over conventional CFS sections. Most of this research work was based on numerical modelling, thus lacking any experimental evidence of the efficiency of these sections. To fulfill this requirement, experimental studies were conducted in this study, on efficient intermediately stiffened CFS sections in flexure, which will result in easy and simple fabrication. Two series of built-up sections, open sections (OS) and box sections (BS), were fabricated and tested under four-point loading with same cross-sectional area. Test strengths, modes of failure, deformed shapes, load vs. mid-span displacements and geometric imperfections were measured and reported. The design strengths were quantified using North American Standards and Indian Standards for cold-formed steel structures. This study confirmed that efficient profiling of CFS sections can improve both the strength and stiffness performance by up to 90%. Closed sections showed better strength performance whereas open sections showed better stiffness performance.

사각단면 강기둥 모서리 곡률의 국부좌굴 강도에 대한 영향 평가 (Influence of Corner Rounding on Local Buckling Strength in Square Sectioned Steel Column)

  • 한금호;김기언;김종헌;강영종
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1096-1101
    • /
    • 2004
  • Generally, the buckling of thin-walled structures has studied for rectangular sections or circular sections. Rectangular sections have small stiffness and circular sections have large stiffness when they are compared with rectangular sections for local buckling. But both of them have similar stiffness to column buckling. Therefore in this paper, we are going to analyze the local buckling for the box section with rounded comer and compare with rectangular section. Also we confirm that the rounded comer section has larger local buckling strength than rectangular section.

  • PDF

Experimental study on axial compressive behavior of welded built-up CFT stub columns made by cold-formed sections with different welding lines

  • Naghipour, Morteza;Yousofizinsaz, Ghazaleh;Shariati, Mahdi
    • Steel and Composite Structures
    • /
    • 제34권3호
    • /
    • pp.347-359
    • /
    • 2020
  • The objective of this study is to experimentally scrutinize the axial performance of built-up concrete filled steel tube (CFT) columns composed of steel plates. In this case, the main parameters cross section types, compressive strength of filled concrete, and the effect of welding lines. Welded built-up steel box columns are fabricated by connecting two pieces of cold-formed U-shaped or four pieces of L-shaped thin steel plates with continuous penetration groove welding line located at mid-depth of stub column section. Furthermore, traditional square steel box sections with no welding lines are investigated for the comparison of axial behavior between the generic and build-up cross sections. Accordingly, 20 stub columns with thickness and height of 2 and 300 mm have been manufactured. As a result, welding lines in built-up specimens act as stiffeners because have higher strength and thickness in comparison to the plates. Subsequently, by increasing the welding lines, the load bearing capacity of stub columns has been increased in comparison to the traditional series. Furthermore, for specimens with the same confinement steel tubes and concrete core, increment of B/t ratio has reduced the ductility and axial strength.