• Title/Summary/Keyword: bottom temperature

Search Result 1,361, Processing Time 0.027 seconds

Thermal Conductivity and Pore Characteristics of Low-Temperature Sintered Lightweight Aggregates Mode from Waste Glass and Bottom Ash (바텀애쉬와 폐유리를 사용하여 제조한 저온소성 경량골재의 열전도율과 기공특성)

  • Lee, Han-Baek;Ji, Suk-Won;Seo, Chee-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.851-858
    • /
    • 2010
  • In this study, waste glass and bottom ash were used as basic materials in order to secure a recycling technology of by-products which was mostly discarded and reclaimed. In addition, because softening point of waste glass is less than $700^{\circ}C$ and bottom ash includes combustible material, it was possible to manufacture low-temperature sintering lightweight aggregates for energy saving at $800{\sim}900^{\circ}C$ that it is as much as 20~30% lower than sintering temperature of existing lightweight aggregates. Thermal conductivity of newly-developed lightweight aggregates was 0.056~0.105W/m. K and its porosity was 40.36~84.89%. A coefficient of correlation between thermal conductivity and porosity was -0.97, it showed very high negative correlationship. With this, we were able to verify that porosity is key factor to affect thermal conductivity. Microstructure of lightweight aggregates by $CaCO_3$ content and replacement ratio of bottom ash in the variation of temperature were that $CaCO_3$ content increased along with pore size while replacement ratio of bottom ash increased as pore size decreased. Specially, most pores were open pore instead of closed pore of globular shape when replacement ratio of bottom ash was 30%, and pore size was small about 1/10~1/5 as compared with case in bottom ash 0~20%. In addition, open pore shapes were remarkably more irregular form of open pore in $900^{\circ}C$ than $700^{\circ}C$ or $800^{\circ}C$ when replacement ratio of bottom ash was 30%. We reasoned hereby that these results will influence on absorption increase, strength and thermal conductivity decrease of lightweight aggregates.

Thermal performance prediction of amorphous steel fibers mixed into the floor heating system (비정질 강섬유 혼입 바닥난방시스템의 열성능 평가)

  • Cho, Hyun;Pang, Seung-Ki
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.130-135
    • /
    • 2016
  • The thermal performance of amorphous steel fibers mixed floor heating system was evaluated. Analysis of results, depending on the hot water supply temperature changes, the average temperature of the bottom of the hot water supply temperature is an amorphous steel fiber floor heating system is about 2~4% higher. The average temperature of the floor surface to 1.5m air amorphous steel fiber system is 1~2% higher. The amount of heat supplied to indoor air (1.5m) from the bottom surface of amorphous steel fiber floor heating system is about 7~8% higher

Analysis of Coal Combustion and Particle Temperature Profiles in a Rotary Kiln for Production of Light-weight Aggregate (경량골재 로타리킬른의 운전최적화를 위한 석탄연소 및 원료입자 승온특성 해석)

  • Park, Jong-Keun;Ryu, Changkook;Kim, Young-Ju
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.3
    • /
    • pp.18-25
    • /
    • 2014
  • Bottom ash from a coal-fired power plant is usually landfilled to a nearby site, which causes a growing environmental concern and increased operating costs. One way of recycling the bottom ash is to produce light-weight aggregate (LWA) using a rotary kiln. This study investigated the temperature profiles of raw LWA particles in a rotary kiln to identify the range of operating conditions appropriate for ideal bloating. For this purpose, a new simulation method was developed to integrate a 1-dimensional model for the bed of LWA particles and the computational fluid dynamics (CFD) for the fuel combustion and gas flow. The temperature of LWA particles was found very sensitive to the changes in the air preheating temperature and excess air ratio. Therefore, an accurate control of the operation parameters was essential to achieve the bloating of LWA particles without excessive sintering or melting.

The Effect of the Metallic Mold Cooling System on the Solidification Structures and the Mechanical Properties for Al-10%Si Alloy Castings (금형주조한 Al-10%Si합금의 응고조직과 기계적 성질에 미치는 금형의 냉각효과에 관한 연구)

  • Lee, Dong-Youn;Cheon, Byung-Wook;Choi, Chang-Ock
    • Journal of Korea Foundry Society
    • /
    • v.13 no.2
    • /
    • pp.155-162
    • /
    • 1993
  • This study has been focused on the influence of the metallic mold cooling effects on the solidification structures and the mechanical properties for Al-10%Si alloy castings by the variation of pouring temperatures, metallic mold temperatures and Cooling part of metallic mold. The dendrite arm spacing of Al-10%Si alloy was decreased with increasing cooling rate. In case of bottom cooling of metallic mold, DAS was appeared to be $20-22{\mu}m$ and in the middle cooling, it was increased to $36-40{\mu}m$. The DAS decreased proportionally $with(cooling\;rate)^{-3/2}$ at pouring temperatures $680^{\circ}C$ and $(cooling\;rate)^{-1/2}$ at pouring temperature $760^{\circ}C$, but it was proportionally increased to $(local\;solidification\;time)^{1/2-1/3}$ at pouring temperature $680^{\circ}C$ and $760^{\circ}C$. The maximum tensile strength of Al-10%Si alloy casting was obtained in case of bottom cooling of mold at pouring temperature $680^{\circ}C$ and metallic mold temperature $320^{\circ}C$.

  • PDF

A Study on the Design and Simulation of Sand Casting for Alumimum Turbo Fan in Tank Powerpack (전차 파워팩에 적용되는 알루미늄 터보 팬의 주조방안 설계 및 주조 해석에 관한 연구)

  • Jin, Chul-Kyu;Lee, Un-Gil
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.889-898
    • /
    • 2022
  • In this study, sand casting process was applied to manufacture a large aluminum turbo-type fan used for tank powerpack. To apply the sand casting method, the turbo fan was reverse engineered, and after designing three gating systems, the optimal gating system design was selected by performing casting simulation. In the case of the bottom up-gating system, there is a significant temperature loss of the molten alloy during blade filling. When the molten alloy is completely filled into the sand mold, the blade upper tip and front shroud are below the liquidus temperature. In the case of the top down-gating system, molten alloy scattering occurs, but the temperature loss while the blade is filled is smaller than that of the bottom up type. And after the inflow of molten alloy into the mold is completed, the blade upper tip and front shroud are higher than the liquidus temperature. A sand mold was manufactured with the top down-gating system and the casting process was performed. The fan was made perfectly in appearance without any unfilled parts.

A Study On the Cooling Effect of the Floating Horizontal Solar Cell

  • Jae-hyuk Lee
    • International journal of advanced smart convergence
    • /
    • v.12 no.2
    • /
    • pp.182-186
    • /
    • 2023
  • In this study, we measured the power and temperature of the floating horizontal solar cell in a coastal lagoon and compared with those of ground solar cell and water platform solar cell. Because the bottom surface of the floating horizontal solar cell was contacting the water, cooling effect was expected stronger than other cells. As a result of the measurement, the power of floating horizontal cell was 11.7% higher than that of the ground cell and 15% higher than that of the water platform cell. During the measurement, it was observed that water waves were continuously flowed on the top surface of floating horizontal cell by the wind, and it could be assumed that the cooling effect occurred not only on the bottom surface of the cell but also on the top surface. In order to analyze the cooling effect and power increasing of the horizontal cell in the wave situation, we measured power and temperature of the cell while generating artificial waves in a laboratory equipped with Zenon lamp as a solar simulator. At the height of thewater surface, the power of the cell with waves was 3.7% higherthan without waves and temperature was 4.6℃ lower. At 1 cm and 2 cm below the watersurface, power of the cell with waves was decreased by 14% and 11% than without waves while temperature was same . At 3 cm below the water surface, there was no effect of waves.

Characteristics of Water Temperature and Salinity in the Bottol Bada, Yeosu during Summer in 2010 (2010년 하계 보돌바다의 수온과 염분 특성)

  • Cho, Eun-Seob
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.4
    • /
    • pp.301-306
    • /
    • 2011
  • This study was determined to analysis the characteristics of water mass in the Bottol Bada, Yeosu in August, 2010 based on the data from the distribution of water temperature and salinity. Sampling was carried out a total of three times (i.e. July 29, August 13, and August 30, 2010) and performed at three stations. Observation was done during the period of time 10:00-15:00, indicating the decreasing tidal height and turn of tide. In July 29, thermocline was found at 4 m in St. 1, but the stratification did not observe in August 13 and August 30. The remarkable water temperature between surface and bottom was found in St. 2 and St. 3, whereas St. 1 did not find. A particular finding during this study showed a cold water mass at bottom layer from St. 2 and St. 3, which was first occurred in July 29 and persisted in August 30 without any of destruction. Water temperature had a remarkable fluctuation between surface and bottom, whereas salinity had a unique in St. 1. St. 2 and St. 3 showed the increasing salinity according to water depth in August 13 and August 30. Transparency had considerable fluctuations in St. 1 and St. 3 depending to sampling date, but St. 2 did not fluctuate. Consequently, the Bottol Bada had a significantly different water mass between inner and outer waters. Furthermore, strong irradiance and weak wind play an important role in developing the stratification between surface and bottom, in particular the introduction of offshore waters contribute to highly developing the stratification in the Bottol Bada during the period of August in 2010.

Low Temperature Storage of Rough Rice Using Cold-Air in Winter(I) - Storage Characteristics after Rough Rice Cooling - (겨울철 냉기를 이용한 벼의 저온저장(I) - 벼 냉각 후 저장특성 -)

  • Lee J. S.;Han C. S.;Ham T. M.;Yon K. S.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.3 s.110
    • /
    • pp.155-160
    • /
    • 2005
  • The objective of this research was to establish a domestically available cooling storage technique by cold-air in winter, using winter cool air ventilation fur determining rough rice cooling method in the storage and dry bin. The rough rice storage characteristics of two test conditions, winter cool-air ventilation storage and ambient temperature storage, were evaluated from January to July 2001, using a storage and dry bin of 300-ton capacity. Results of this research are as follows: Grain temperature was from $-5.1\~-8.5^{\circ}C$ after winter cool-air ventilation, and grain initial temperature for ambient temperature bin storage was $0.3\~1.9^{\circ}C$. Moisture content of rough rice decreased from $0.28\;to\;0.93\%$ and from $1.53\;to\;1.92\%$ to compare with original moisture contents for winter cool-air ventilation, and for ambient temperature bin storage, respectively. Broken ratio of brown rice from winter cool-air ventilation bin increased from $0.16\;to\; 0.92\%$, and brown rice broken ratio was from $2.24\;to\;2.86\%$ for ambient temperature bin storage to compare with initial broken ratio. Hardness of stored rice increased along storage period increase in alt storage methods, and cooling bin storage increased rice hardness of 0.271kgf: this increasing was lower then the other methods from 0.059 to 2.239kgf. Germination rates were decreased approximately 9.03, 3.14 and $3.20\%$ for upper, middle, and bottom of ventilating winter air bin, respectively, and germination rates of 2.70, 3.47 and $4.14\%$ were approximately decreased for upper, middle, and bottom parts of ambient temperature bin storage, respectively.

An Experimental Study on the Temperature Difference between the Top and Bottom Flange in Steel Girder without Concrete Slab (콘크리트 슬래브가 없는 강재주형에서 상하연 온도차에 대한 실측연구)

  • Shin, Dong-Wook;Kim, Kyoung-Nam;Jung, Kyoung-Sup;Lee, Seong-Haeng
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.99-106
    • /
    • 2014
  • In order to study the reasonable design thermal loads, the steel box girder bridge specimen which have no concrete slab was manufactured with the real size dimension. The temperature data were measured for 5 month at the 18 thermo gauges which were attached according to height. The temperature differences between the top and bottom flange in steel box girder specimen were calculated and the temperature gradient models were proposed by the probabilistic method. This proposed model showed a correlation of approximately 97% when compared with the similar model of Euro Code. Thus, the temperature gradient models which were suggested in this study may be used as the basis data in calculating the design load temperature.

Manufacturing artificial lightweight aggregates using coal bottom ash and clay (석탄 바닥재와 점토를 이용한 인공경량골재 제조)

  • Kim, Kang-Duk;Kang, Seung-Gu
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.17 no.6
    • /
    • pp.277-282
    • /
    • 2007
  • The artificial lightweight aggregate (ALA) was manufactured using coal bottom ashes produced from a thermoelectric power plant with clay and, the sintering temperature and batch composition dependence upon physical properties of ALA were studied. The bottom ash (BA) had 13wt% coarse particle (>4.75mm) and showed very irregular shape so should be crushed to fine particles to be formed with clay by extrusion process. Also the bottom ash contained a many unburned carbon which generates the gas by oxidation and lighten a aggregate during a sintering process. Plastic index of green bodies decreased with increasing bottom ash content but the extrusion forming process was possible for the green body containing BA up to 40wt% whose plastic index and plastic limit were around 10 and 22 respectively. The ALA containing $30{\sim}40wt%$ BA sintered at $1100{\sim}1200^{\circ}C$ showed a volume specific density of $1.3{\sim}1.5$ and water absorption of $13{\sim}15%$ and could be appled for high-rise building and super-long bridge.