대형 바렛말뚝과 현장타설말뚝의 하중전이특성 파악을 위한 재하시험 (Pile Load test on a Large Barrette Pile and a Bored Pile for the Identification of the Load Transfer Characteristics)

  • 한성길;박종관
    • 한국철도학회논문집
    • /
    • 제9권4호
    • /
    • pp.493-498
    • /
    • 2006
  • In this study, two large pile load tests were performed in the deep sand gravel deposit of Nakdong river basin so that the characteristics of the load transfer was identified. The fully instrumented rectangular barrette pile in the size of $1.5\times3.0m$ and the circular bored pile of the diameter 1.5 m were placed into the ground below 50 m. Under the applied loads of 2,400 tonf and 4,000 tonf, the test results of the load transfer showed the portion of 83% and 93% of the applied loads on the barrette pile and the bored pile, respectively, were supported by the skin friction along the pile shaft. It was revealed that the most of these skin friction mobilized in sand layer underlying clay layer having N-value more than 30 and that the friction per unit area of the bored pile was larger than the friction of barrette pile. However, if embedded in the stiff sand graval layer, the both piles were proven to be sufficient for using as the friction piles.

점성토지반속 주열식 흙막이벽의 설계법 (A Design Method of Earth-Retaining Structure Constructed by a Row of Bored Piles in Cohesive Soils)

  • 홍원표;권우용;고정상
    • 한국지반공학회지:지반
    • /
    • 제5권3호
    • /
    • pp.29-38
    • /
    • 1989
  • 도시내 지하굴착공사에 저진동, 저소음의 장점이 있어 많이 사용될 수 있는 주열식 흙막이벽편 말뚝의 설계법이 제안되며, 그 실용성이 설계례를 통하여 검토된다. 먼저 점성토지반 속에 설치된 주렬식 흙막이말뚝의 저항력 산정식이 굴착 저면을 기준으로 상부와 하부지반에 대하여 각카 제시 된다. 이 산정식의 특징은 지반특성과 말뚝의 설치간격을 합리적으로 고려할 수 있자는 점이다. 이 저항력 산정식을 활용하여 흙막이 말뚝의 안정해절법이 확립된다. 흙막이 말뚝의 설계는 말뚝의 안 정성과 지반의 안정성을 동시에 만족시키는 범위에서 책시되며, 지반의 안정성 검토시에는 굴착 저 부에서의 정토지반 융기현상에 대한 안전검토도 실시된다.

  • PDF

SPT 에너지효율 측정 롯드를 이용한 매입말뚝의 선단지지력 예측 (Prediction of End Bearing Capacity for Pre-Bored Steel Pipe Piles Using Instrumented Spt Rods)

  • 남문석;박영호;박용석
    • 한국지반공학회논문집
    • /
    • 제29권12호
    • /
    • pp.105-111
    • /
    • 2013
  • 국내외에서 널리 사용 중인 표준관입시험(Standard Penetration Test, SPT)은 작업의 용이성, 다양한 지반정수와 강도정수를 결정방법 등의 장점을 지니고 있다. 이러한 SPT 수행시에 발생하는 해머 에너지는 N치의 산정 및 보정에 매우 중요한 영향인자가 된다. SPT시험시 해머 타격에 의하여 롯드로 응력파가 전달되는 현상이 말뚝 항타 시에 발생하는 현상과 동일하다하여 SPT에 PDA장비를 적용하여 관입에너지를 측정하는 방법이 개발되어 사용 중에 있다. 본 연구에서는 SPT 롯드를 말뚝으로 가정하여 SPT 에너지 효율 측정롯드를 SPT시험과 동적콘관입시험에 적용하여 얻어진 힘과 속도의 파형을 매칭기법(CAPWAP, CAse Pile Wave Analysis Program) 분석을 수행하여 매입말뚝에 대한 극한선단지지력을 예측하는 기법을 제안하였다. 또한, SPT 에너지 효율 측정롯드에서 예측된 선단지지력과 실물 말뚝정재하시험을 통하여 산정된 선단지지력을 비교분석하였다. 연구결과를 토대로 SPT나 동적콘관입시험을 통하여 매입말뚝의 지지력을 간편하게 예측할 수 있는 경험식을 제시하였다.

전자기파를 이용한 모래 지반에 설치된 현장타설말뚝의 네킹 결함 평가를 위한 실내 모형실험 (Laboratory Experiments for Evaluating Necking Defects in Bored Piles Embedded in Sandy Soils Using Electromagnetic Waves)

  • 이종섭;김영대;유정동
    • 한국지반공학회논문집
    • /
    • 제36권5호
    • /
    • pp.25-34
    • /
    • 2020
  • 최근 현장타설말뚝의 네킹 결함을 평가하기 위한 비파괴평가기법으로 전자기파를 적용하는 연구가 활발히 진행되고 있다. 하지만, 전자기파의 전파는 주변 매질의 함수비에 큰 영향을 받는다. 본 연구에서는 서로 다른 함수비의 모래 지반에 설치되어 있는 현장타설말뚝에 발생한 네킹 결함을 전자기파를 이용하여 평가할 수 있는 방법을 실내실험을 통해 고찰하고자 한다. 실내실험을 위해 네킹 결함이 있는 직경 600mm, 길이 1m의 모형 말뚝을 제작하였으며, 건조된 모래와 함수비가 10%, 20%, 30%인 모래에 설치된 조건에서 실험을 수행하였다. 전자기파의 전파를 위해 철근망에 전선을 설치하여 전송선로를 구성하였다. 전자기파의 송신과 수신을 위해 time domain reflectometer를 사용하였다. 실험결과, 모형 말뚝의 두부와 선단부뿐만 아니라 네킹 결함부에서도 전자기파의 반사 신호가 뚜렷이 나타났다. 모래의 함수비가 증가할수록 네킹 결함부에서 반사되는 전자기파 신호의 최대 진폭이 감소하였으며, 모형 말뚝 선단에서 반사된 전자기파의 속도는 네킹 결함 내의 모래의 함수비가 증가할수록 감소하였다. 하지만, 전자기파의 도달시간과 속도를 이용하여 산정된 네킹 결함의 위치와 실제 네킹 결함의 위치가 거의 같았다. 본 연구는 전자기파가 모래 지반에 설치된 현장타설말뚝의 네킹 결함을 평가하는데 유용하게 활용될 수 있음을 보여준다.

Polymer Base Bored Pile in Bangkok Subsoils

  • Teparaksa, Wanchai
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.407-426
    • /
    • 2008
  • The bentonite slurry has been used as the stabilize suspension for wet process bored pile construction in Thailand. The bentonite suspension has benefit on filtration in the sand layer, but it creates thick cake film along pile shaft and loose sedimentation at pile toe. The base grouting technique was widely used to rectify the soft base or loose sedimentation problem of bored pile. The base grouting technique was not increased only end bearing capacity, but was also more increase in skin friction capacity of the bored piles. The comprehensive researches on base grouting was carried out by installing PVC casing inside the shaft to allow the drilling through the pile base in order to collect the soil sample below the pile tip. The polymer based slurry recently was used to replace the bentonite slurry to overcome the thick cake film along pile shaft as well as loose sedimentation at pile toe. The extent research on polymer slurry by physical model was performed to verify the real behavior of polymer. The appropriate mixing ratio of polymer was proposed. The design skin friction coefficient, $\beta$ and end bearing coefficient, Nq, for sand layer base on fully instrumented tested pile were proposed. The application on remedial of the lose capacity bored pile with large displacement in Bangladesh was proposed and discussed.

  • PDF

Deep Foundations for High-Rise Buildings in Hong Kong

  • Sze, James W.C.
    • 국제초고층학회논문집
    • /
    • 제4권4호
    • /
    • pp.261-270
    • /
    • 2015
  • Hong Kong is a renowned small city with densely placed skyscrapers. It is no surprise that heavy duty or even mega foundations are built over the years to support these structures. To cope with the fast construction pace, several heavy deep foundation types have been widely adopted with some prescribed design rules. This Paper has selected two commonly adopted but distinctive foundation types, namely large diameter bored piles and percussive steel H-piles to illustrate the special design and construction considerations related to these pile types in related to local context. The supervision requirement in related to foundation works for which again may be unique in Hong Kong will also be highlighted. A case history is also discussed in the later part of the Paper to illustrate the application of one of these foundations and to highlight the importance of considering foundation design and basement excavation method in a holistic manner.

SPT-N값에 따른 매입말뚝의 선단지지력 특성 연구 (Study on the Evaluation of End Bearing Capacity of Pre-Bored Piles for the SPT-N value)

  • 서동남;최상호;김진식;김성철;이동현;조성준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.133-134
    • /
    • 2020
  • The equation of end bearing capacity is applied differently depending on the type of pile, construction method, and load characteristics considering the construction standards. The bearing capacity equation of the design standard is presented in various ways according to the design conditions such as construction method and ground condition, etc. but, It does not reflect the ground strength according to the SPT-N value of weathered rock. This study analyzed the trend of allowable tip bearing capacity by pile diameter through about 480 dynamic loading tests conducted for the construction/quality management of piles for the last 6 years since 2015. The equation for the ultimate end bearing capacity per unit area according to the SPT-N value is presented. The proposed formula of ultimate end bearing capacity per unit area can be applied in the range of 15,000kN/m2 to 30,000kN/m2. The proposed formula, which complements the existing formula, enables pile design and construction/quality management.

  • PDF

Pile tip grouting diffusion height prediction considering unloading effect based on cavity reverse expansion model

  • Jiaqi Zhang;Chunfeng Zhao;Cheng Zhao;Yue Wu;Xin Gong
    • Geomechanics and Engineering
    • /
    • 제37권2호
    • /
    • pp.97-107
    • /
    • 2024
  • The accurate prediction of grouting upward diffusion height is crucial for estimating the bearing capacity of tip-grouted piles. Borehole construction during the installation of bored piles induces soil unloading, resulting in both radial stress loss in the surrounding soil and an impact on grouting fluid diffusion. In this study, a modified model is developed for predicting grout diffusion height. This model incorporates the classical rheological equation of power-law cement grout and the cavity reverse expansion model to account for different degrees of unloading. A series of single-pile tip grouting and static load tests are conducted with varying initial grouting pressures. The test results demonstrate a significant effect of vertical grout diffusion on improving pile lateral friction resistance and bearing capacity. Increasing the grouting pressure leads to an increase in the vertical height of the grout. A comparison between the predicted values using the proposed model and the actual measured results reveals a model error ranging from -12.3% to 8.0%. Parametric analysis shows that grout diffusion height increases with an increase in the degree of unloading, with a more pronounced effect observed at higher grouting pressures. Two case studies are presented to verify the applicability of the proposed model. Field measurements of grout diffusion height correspond to unloading ratios of 0.68 and 0.71, respectively, as predicted by the model. Neglecting the unloading effect would result in a conservative estimate.

현장타설말뚝의 네킹 결함 평가를 위한 전자기파의 적용성 연구 (Application of Electromagnetic Wave for Evaluating Necking Defects in Bored Piles)

  • 이종섭;송정욱;유정동
    • 한국지반공학회논문집
    • /
    • 제34권4호
    • /
    • pp.27-35
    • /
    • 2018
  • 본 연구의 목적은 현장타설말뚝에 발생한 네킹 결함을 평가하기 위해 전자기파의 적용성을 검증하는데 있다. 본 연구에서는 네킹 결함이 있는 직경 150mm, 길이 270mm의 소형 모형 말뚝에 대해 실험을 수행하였다. 말뚝에 모사된 결함은 총 4개이며, 이 중 두 개의 결함은 모형 말뚝의 서로 다른 면의 상부와 하부에 각각 모사되었으며, 나머지 두 개의 결함은 같은 면의 상부와 하부에 모사되었다. 전선을 철망을 이루고 있는 스테인리스 재질의 철사를 따라 설치하여 두개의 도체로 구성된 전송선로를 구성하였으며, time-domain reflectometer를 이용하여 전자기파를 송 수신하였다. 실험 결과, 모형 말뚝의 결함부와 선단부에서 전자기파의 반사 신호가 나타났다. 측정된 반사 신호로부터 결함의 위치를 산정한 결과, 실제의 결함 위치와 거의 같게 산정되었다. 본 연구의 결과는 전자기파가 현장타설말뚝의 네킹 결함을 평가하는데 있어 유용한 기법이 될 수 있음을 보여준다.

Development of an optimized model to compute the undrained shaft friction adhesion factor of bored piles

  • Alzabeebee, Saif;Zuhaira, Ali Adel;Al-Hamd, Rwayda Kh. S.
    • Geomechanics and Engineering
    • /
    • 제28권4호
    • /
    • pp.397-404
    • /
    • 2022
  • Accurate prediction of the undrained shaft resistance is essential for robust design of bored piles in undrained condition. The undrained shaft resistance is calculated using the undrained adhesion factor multiplied by the undrained cohesion of the soil. However, the available correlations to predict the undrained adhesion factor have been developed using simple regression techniques and the accuracy of these correlations has not been thoroughly assessed in previous studies. The lack of the assessment of these correlations made it difficult for geotechnical engineers to select the most accurate correlation in routine designs. Furthermore, limited attempts have been made in previous studies to use advanced data mining techniques to develop simple and accurate correlation to predict the undrained adhesion factor. This research, therefore, has been conducted to fill these gaps in knowledge by developing novel and robust correlation to predict the undrained adhesion factor. The development of the new correlation has been conducted using the multi-objective evolutionary polynomial regression analysis. The new correlation outperformed the available empirical correlations, where the new correlation scored lower mean absolute error, mean square error, root mean square error and standard deviation of measured to predicted adhesion factor, and higher mean, a20-index and coefficient of correlation. The correlation also successfully showed the influence of the undrained cohesion and the effective stress on the adhesion factor. Hence, the new correlation enhances the design accuracy and can be used by practitioner geotechnical engineers to ensure optimized designs of bored piles in undrained conditions.