• Title/Summary/Keyword: bone screw fixation

Search Result 180, Processing Time 0.023 seconds

The Effects of Spinopelvic Parameters and Paraspinal Muscle Degeneration on S1 Screw Loosening

  • Kim, Jin-Bum;Park, Seung-Won;Lee, Young-Seok;Nam, Taek-Kyun;Park, Yong-Sook;Kim, Young-Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.357-362
    • /
    • 2015
  • Objective : To investigate risk factors for S1 screw loosening after lumbosacral fusion, including spinopelvic parameters and paraspinal muscles. Methods : We studied with 156 patients with degenerative lumbar disease who underwent lumbosacral interbody fusion and pedicle screw fixation including the level of L5-S1 between 2005 and 2012. The patients were divided into loosening and non-loosening groups. Screw loosening was defined as a halo sign larger than 1 mm around a screw. We checked cross sectional area of paraspinal muscles, mean signal intensity of the muscles on T2 weight MRI as a degree of fatty degeneration, spinopelvic parameters, bone mineral density, number of fusion level, and the characteristic of S1 screw. Results : Twenty seven patients showed S1 screw loosening, which is 24.4% of total. The mean duration for S1 screw loosening was $7.3{\pm}4.1$ months after surgery. Statistically significant risk factors were increased age, poor BMD, 3 or more fusion levels (p<0.05). Among spinopelvic parameters, a high pelvic incidence (p<0.01), a greater difference between pelvic incidence and lumbar lordotic angle preoperatively (p<0.01) and postoperatively (p<0.05). Smaller cross-sectional area and high T2 signal intensity in both multifidus and erector spinae muscles were also significant muscular risk factors (p<0.05). Small converging angle (p<0.001) and short intraosseous length (p<0.05) of S1 screw were significant screw related risk factors (p<0.05). Conclusion : In addition to well known risk factors, spinopelvic parameters and the degeneration of paraspinal muscles also showed significant effects on the S1 screw loosening.

CLINICAL STUDY ON USE OF BIODEGRADABLE PLATE AND SCREW IN ORTHOGNATHIC SURGERY (턱교정 수술에 있어 흡수성 고정판 및 나사 사용에 대한 임상적 연구)

  • Park, Sung-Soo;Choi, Jin-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.127-135
    • /
    • 2009
  • Objectives : The titanium fixation system has been used in orthognathic surgery for fixation of bone segments usually, but the biodegradable fixation system was developed and also being used. The strongest point in the biodegradable system is that no extra operation should be needed to remove fixation materials. In spite of this merit, oral & maxillofacial surgeons hesitate to use this system in fracture or orthognathic surgery. In this study, as we got some clinical experiences, we'd like to report the result of clinical study using the biodegradable fixation system in orthognathic surgery. Patients and Methods : A total of 35 patients composed of 17 males and 18 females with 25 osteotomies in maxilla and 34 osteotomies in mandible were fixated with the biodegradable fixation system(Inion $CPS^{(R)}$). We investigated methods of stabilization, fixation time, and complications on the basis of the method as above. Results : Four 2mm thick L shaped plates with 7 holes of which 1 hole was removed were fixed in maxilla with six $2.0{\times}7mm$ screws. Three $2.5{\times}16{\sim}18mm$ screws were used to fix superior ramus area and one mandibular angle area in mandible. It took about 27.4 minutes in maxilla, 25.3 minutes in mandible to perform the fixation which took longer time than the titanium system(9.5 minutes in maxilla, 8 minutes in mandible). Generally, there was no problem except 9 cases in which there were some complications. Conclusions : In most cases, the biodegradable fixation system can be used without problem in usual orthognathic surgery. But, this system is inferior to the titanium fixation one in some respects such as fixation time, size, and physical property. Some supplementations for such weak points as aforementioned should be needed for the universal use of biodegradable materials.

Comparison of F Calcaneal Plate and Locking Calcaneal Plate Fixation Using an Lateral Extensile Approach to Intra-articular Calcaneal Fractures (종골의 관절 내 골절에서 외측 광범위 도달법을 이용한 F형 금속판 고정술과 잠김 금속판 고정술의 비교)

  • Lee, Yun-Tae;Oh, Hyun-Cheol;Yoon, Han-Kook;Jang, Jae-Won;Jang, Ki-Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.3
    • /
    • pp.175-180
    • /
    • 2012
  • Purpose: To evaluate the radiological and clinical results after open reduction and internal fixation with calcaneal F plate and locking calcaneal plate using lateral extensile approach in the treatment of intra-articular calcaneal fracture Materials and Methods: This study included 34 cases of 33 patients followed up for at least 6 months postoperatively. F plate was applied in 18 cases (Group 1), locking plate was used in 16 cases (Group 2) and compared radiological and clinical results between two groups. Results: Radiollogically, the mean Bohler angle was improved from $5.5^{\circ}$ preoperatively to $20.1^{\circ}$ postoperatively and $18.8^{\circ}$ at the last follow up in group 1 and $8.6^{\circ}$ preoperatively, $21.4^{\circ}$ postoperatively and $20.3^{\circ}$ at last follow up in group 2. Bone union was observed in all cases and 4 cases of screw loosening were noted in Group 1 with extended fracture to anterior process. At the last follow up, both groups showed clinical results in American orthopedic foot and ankle society ankle hindfoot score, 76(77 in Sanders type II and 75 in type III) in group 1 and 72(73 in type II and 70 in type III) in group 2. Conclusion: F plate and locking plate showed firm fixation and satisfactory clinical results in the treatment of intra-articular calcaneal fracture. We suggest applying locking plate in cases with extended fracture to anterior process, considering screw loosenings in those who were treated with F plate fixation.

PHOTOELASTIC STRESS ANALYSIS OF LOAD TRANSFER TO SATELLITE ABUTMENT AS AN IMMEDIATE ABUTMENT (인공치아의 즉시부하를 위해 새로이 개발된 인공치아 지대주(Satellite Abutment)의 광탄성 응력 분석)

  • Park, Sang-Kyu;Lee, Baek-Soo;Engelke, W;Kim, Boo-Dong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.6
    • /
    • pp.472-479
    • /
    • 2002
  • Since $Br^{\circ}anemark$ introduced the osseointegrated implants, they have been granted for useful methods for the restoration of oral function. The original $Br^{\circ}anemark$ protocol recommended long stress-free healing periods to achieve the osseointegration of dental implants. However, many clinical and experimental studies have shown that the osseointegration is no wonder in almost cases and that early and immediate loading may lead to predictable osseointegration. So we are willing to introduce the Satellite Abutment newly invented for immediate loading. We think that it will make the occlusal forces dispersed to surrounding bone and that we can restore the oral function immediately after implant installation not disturbing osseointegration. In case of using Satellite abutment, stress concentrated to bone contact area of implant was distributed not only fixation plate and screws but also superior, middle portion of implant and cortical layer of jaw bone. It was clearly decreased on the bone contact surfaces around dental implants. 1. Stress was decreased more than 76.5% when satellite straight abutment was used. 2. Stress was decreased more than 50% when satellite angled abutment was used. 3. The stress around dental implant was well distributed along the cortical bone surface and the fixation plate and screw. This study concludes that satellite abutment can be used as all immediate loading implant prothesis because it was possible to distribute periimplant occlusal stress through implant contact bone surface and cortical layer of jaw bone.

Breakage of Core Reamer During Anterior Cruciate Ligament Reconstruction -A Case Report- (자가 슬개건을 이용한 전방십자인대 재건술 시 경골터널 생성중 핵심 확공기의 파열 - 증례보고 -)

  • Noh, Jung-Ho;Yang, Bo-Kyu;Park, Jung-Tae;Je, Min-Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.1
    • /
    • pp.33-35
    • /
    • 2010
  • This is a case of the core reamer breakage during anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft. A 19-year-old man with acute anterior cruciate ligament rupture had reconstruction surgery. During tunneling in the proximal tibia, the core reamer have been cracked open and broken. Rest of the procedure was performed routinely except the tibial sided fixation of bone block which was performed with larger interference screw than usual. The patient followed the accelerated rehabilitation program. The result was satisfactory at 2 years after surgery.

  • PDF

Comparative Study of Skeletal Relapse According to the Fixation Method after BSSRO for Mandibular Setback. (하악 시상골 절단술 후 고정 방법에 따른 회귀 성향에 대한 비교 연구)

  • Bae, Jin-Oh;Lee, Dong-Keun;Oh, Sung-Hwan;Sin, Ki-Young;Chang, Kwan-Sik
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.2
    • /
    • pp.184-190
    • /
    • 2000
  • Objective : To compare two different methods of rigid fixation in postoperative stability after mandibular setback. Material and Methods : 28 patients with Class III malocclusion were treated by bilateral sagittal split ramus osteotomy(BSSRO) and mandibular setback were selected for this study. Group A(n=14) had the bone segments fixed with monocortical miniplate on the lateral side of the mandibular body and Group B(n=14) had three noncompressive bicortical screw inserted at the genial area through a transcutaneous approach. Cephalograms were taken preoperatively, postoperatively within 1 weeks and at a follow-up period (mean 8.9 months after surgery) and the amount of setback and postoperative change were measured. Results : Postoperative relapse between two groups was minimal in setback of the mandible. Statistical analysis showed no significant difference in postoperative relapse. Conclusion : This study suggests that both methods of skeletal fixation investigated give comparable postoperative stability and their use in mandibular setback appears to be a fairly stable clinical procedure .

  • PDF

Fracture and Dislocation of Lisfranc Joint: Treatment with Screw and Kirschner Wire (리스프랑 관절 골절 및 탈구: 나사와 Kirschner 강선을 이용한 치료)

  • Ha, Dong-Jun;Kim, Jeon-Gyo;Gwak, Heui-Chul;Jang, Yue-Chan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.4
    • /
    • pp.181-187
    • /
    • 2015
  • Purpose: The purpose of this study is to retrospectively analyze the clinical results of screws and Kirschner wire (K-wire) fixation in patients with fracture dislocation of Lisfranc joint and the consequence of screw breakage. Materials and Methods: Sixty patients underwent Lisfranc joint open reduction and removal of internal fixators from January 2007 to December 2011. Forty-nine cases (81.7%) underwent operations with screw alone, and 11 cases (18.3%) underwent operations with both screws and K-wires. Type of internal fixators, duration of internal fixator removal, breakage of internal fixators and satisfaction with reduction were investigated. Additionally, American Orthopaedic Foot and Ankle Society (AOFAS) midfoot scales were analyzed. Results: The internal fixator was broken in 5 cases (8.3%). The average duration of instrument removal was 154 days in the non-broken screw group and 268.6 days in the broken screw group (p<0.05). The average AOFAS midfoot scale was 77.4 in the non-broken screw group and 74.2 in the broken screw group. The most commonly damaged portion was the first tarsometatarsal (Lisfranc) joint. Conclusion: Treatment with screws and K-wires was effective in patients with fracture dislocation of Lisfranc joint. The appropriate time for screw removal should be considered.

The Result of Mandible Fracture Fixations with Biodegradable Materials (생체흡수성 재료를 이용한 하악골절 치료의 결과)

  • Wang, Jae Kwon;Eun, Seok Chan;Heo, Chan Yeong;Baek, Rong Min;Minn, Kyung Won
    • Archives of Craniofacial Surgery
    • /
    • v.9 no.2
    • /
    • pp.45-50
    • /
    • 2008
  • Purpose: Traditionally, titanium miniplate has been used for rigid fixation of mandible fractures. However, the limitations of metal plate have been reported such as hypersensitivity, interference with the cranio-facial growth of growing child, secondary bone resorption around the plate, foreign body reaction, declination of primary callus formation, and bone atrophy, and so forth. Recently, biodegradable miniplate has been introduced and used as an alternative to the metal plate despite of its lower strength. This study evaluated the usefulness and stability of biodegradable plate and screw for treatment of mandible fractures. Methods: In this study, 61 patients(92 areas) diagnosed as mandible fracture in the last 2 years have been reviewed. We used titanium plate and screw in 32 patients, and biodegradable plate and screw($INION^{(R)}$) in 29 patients. Stability of plates and screws, bony healing process and its side effects were observed by clinical and radiographic assessment. Results: In the titanium material group, one of malocclusion, two of mouth opening limitation, three of pain, three of palpation were shown. The plate of six patients involved in these complications were removed. In the biodegradable group, two of mouth opening limitation, two of pain, one of localized wound infection were shown and one plate was removed secondarily. Conclusion: There was no statistical difference between two groups in bony healing and complication rates. Biodegradable implants show efficient stability during initial bone healing and low side effects in long-term follow up periods.

STUDY OF MAXILLARY CORTICAL BONE THICKNESS FOR SKELETAL ANCHORAGE SYSTEM IN KOREAN (Skeletal Anchorage System의 식립을 위한 한국인 악골의 피질골 두께에 대한 연구)

  • Kim, Ji-Hyuck;Joo, Jae-Yong;Park, Young-Wook;Cha, Bong-Kuen;Kim, Soung-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.4
    • /
    • pp.249-255
    • /
    • 2002
  • Recently, Skeletal Anchorage System (SAS) has been focused clinically with the view point that it could provide the absolute intraoral anchorage. First, it began to be used for the patient of orthognathic surgery who had difficulty in taking intermaxillary fixation due to multiple loss of teeth. And then, its uses have been extended to many cases, the control of bone segments after orthognathic surgery, stable anchorage in orthodontic treatment, and anchorage for temporary prosthesis and so on. SAS has been developed as dental implants technique has been developed and also called in several names; mini-screw anchorage, micro-screw anchorage, mini-implant anchorage, micro-implant anchorage (MIA), and orthosystem implant etc. Now many clinicians use SAS, but the anatomical knowledges for the installed depth of intraosseous screws are totally dependent on general experiences. So we try to study for the cortical thickness of maxilla and mandible in Korean adults without any pathologic conditions with the use of Computed Tomography at the representative sites for the screw installation.

CLINICAL STUDY OF RESORBABLE PLATE AND SCREW FOR TREATMENT OF MAXILLOFACIAL FRACTURES (악안면 골절 치료시 흡수성 고정판의 사용에 관한 임상 연구)

  • Jeong, Jong-Cheol;Choi, Se-Hoon;Song, Min-Soek;Jun, Chang-Hun;Kim, Hyun-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.6
    • /
    • pp.438-443
    • /
    • 2003
  • Purpose : This study evaluated the usefulness of resorbable plate and screw for treatment of maxillofacial bone fractures. Patients and methods : From july, 2000 to july, 2002, we used resorbable plates and screws($Biosorb^{(R)}$ FX, Bionix Inc, Finland) on 126 patients for treatment of maxillofacial bone fractures. Among them, 80 patients were capable of periodic following up to present season. We evaluated these patients with clinical, radiographic findings and subjective satisfaction. Results : 80 patients composed of 63 men and 17 women. Complication rates are 7.5%(6/80) recorded. 1 of bulging sensation, 3 of infection sign, 2 of the plate detachment were shown. The plates involved in such complications were removed. The other patients(92.5%) were not shown any problems. We could not find complete resorption of screw holes in the mandibular symphysis area even though two years later after surgery. Conclusion : Bioresorbable plates and screws are useful as fixation material at maxillofacial fractures although strength is thought to be weaker than titanium plate. But to reduce the possible complicaions, need to careful clinical and radiographical evaluations.