• Title/Summary/Keyword: bone measurement

Search Result 444, Processing Time 0.03 seconds

The Influences of Bowel Condition with Lumbar Spine BMD Measurement (요추부 골밀도 측정 시 장내 변화가 골밀도에 미치는 영향)

  • Yoon, Joon;Kim, Yun-Min;Lee, Hoo-Min;Lee, Jung Min;Kwon, Soon-Mu;Cho, Hyung-Wook;Kang, Yeong-Han;Kim, Boo-Soon;Kim, Jung-Soo
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.273-278
    • /
    • 2014
  • Bone density measurement use of diagnosis of osteoporosis and it is an important indicator for treatment as well as prevention. But errors in degree of precision of BMD can be occurred by status of patient, bone densitometer and radiological technologist. Therefore the author evaluated that how BMD changes according to the condition of the patient. As Lumbar region, which could lead to substantial effects on bone density by diverse factors such as the water, food, intentional bowels. We recognized a change of bone mineral density in accordance with the height of the water tank and in the presence or absence of the gas using the Aluminum Spine Phantom. We also figured out the influence of bone mineral density by increasing the water and food into a target on the volunteers. Measured bone mineral density through Aluminum Spine Phantom had statistically significant difference accordance with increasing the height of water tank(p=0.026). There was no significant difference in BMD according to the existence of the bowl gas(p=0.587). There was no significant difference in a study of six people targeted volunteers in the presence or absence of the food(p=0.812). And also there was no significant difference according to the existence of water(p=0.618). If it is not difficult to recognize the surround of bone in measuring BMD of lumbar bone, it is not the factor which has the great effect on bone mineral density whether the test is after endoscopic examination of large intestine and patient's fast or not.

24hr Whole-Body Retension of $^{99m}Tc-Methylene$ Diphosphonate and Osteocalcin in patients with Hyperthyroidism (갑상선기능항진증에서 $^{99m}Tc-MDP$ 24시간 정체율과 Osteocalcin)

  • Yeoum, Kwang-Seop;Lee, Jin-Oh;Kang, Tae-Woong;Hong, Sung-Woon;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.222-228
    • /
    • 1990
  • The development of histomorphometric and histodynamic investigations has permitted the description of a specific and complex osteopathy in hyperthyroidism. The increased bone turnover rate in hyperthyroid patients may be accompanied by a considerable bone loss. These features are associated with both inclosed osteoclastic bone resorption and increased osteoblastric bone formation, with an accelerated calcification rate. Conventional biochemical markers of bone metabolism, i.e. serum calcium and alkaline phosphatase and urinary hydroxyproline and calcium are normal in most patients with hyperthyroidism. However, the correlation between serum BGP and serum concentration of thyroid hormon suggests that serum BGP may be a sensitive marker of increased bone formation due to the hypersecretion of thyroid hormones. Any increase in bone turnover, whether focal or diffuse, will result in an increase in $^{99m}Tc-methylenediphosphonate$ uptake (MDP). The measurement of this uptake in hyperthyroid patients by bone provides a sensitive and objective means of quantifying skeletal metabolism. Using a standard shadow-shield whole-body monitor and radioimmunoassay kit, we have measured whole-body retention of $^{99m}Tc-MDP$ up to 24hr and concentration of serum Osteocalcin in 20 patients with hyperthyroidism and in 42 normals. The results were as follows; 1) The average of serum Osteocalcin level in 42 patients with normals was $9.90{\pm}4.87(ng/ml)$ and in 20 patients with hyperthyroidism was $19.54{\pm}5.7(ng/ml)$. Both the averages of serum Osteocalcin and 24hr $^{99m}Tc-MDP$ uptakes in hyperthyroid patients were higher than those in normals. 2) $^{99m}Tc-MDP$ uptakes in skeletal system increased in proportion to normal ageing after 40 yrs old in 42 patients with normals. The average of $^{99m}Tc-MDP$ uptakes in hyperthyroid patients were higher than those in normals without related ageing. 3) A significant relationships between the $^{99m}Tc-MDP$ uptakes and serum Osteocalcin level were peformed (r=0.55, $y=17.58+6.7\times$). From the above results we concluded that the measurement of serum Osteocalcin and 24hr $^{99m}Tc-MDP$ uptakes can be used for evaluation of bone turnover as a specific marker in hyperthyroid patients.

  • PDF

The Assessment on the Characteristics of Quantitative Image in Digora$\textregistered$ (Digora$\textregistered$에서 정량영상의 특성에 대한 평가)

  • Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.397-405
    • /
    • 1999
  • Purpose: To clarify the usefulness and the limitation of Digora system/sup (R)/ by evaluating the physical characteristics as the quantitative image on Image Plate(Ip). Materials and Methods: Radiograms were taken by Heliodent MD(Siemens Co.. Germany) with the image plate for adult. Cu-step wedge as reference material. and three pieces of dry mandibular bone. Image analysis was performed by single color enhancement. density measurement with histogram. The relationship between the exposure conditions and the distribution of the pixel values of the image. the variation of pixel values of each step of Cu-step wedge at two different area and Cu-equivalent value of three pieces of dry mandibular bone measure by the conversion equation. Results: There was no linear relationship between the exposure condition and the average pixel value of the image. of which the distribution was not even. The pixel value differences between the center portion and the periphery were ranged from 60 to 70 in vertical plane and from 15 to 26 in horizontal plane. Two plot profile formed at two different areas of the Cu-step wedge were different. The measured Cu-equivalent values showed the discrepancy among the times of measurement. Conclusion: As above results. Image Plate(Ip) of Digora system/sup (R)/ showed the limitation as the quantitative image. The physical property of IP was expected to need to be compensated for the quantitative evaluation of the bone or others

  • PDF

Comparison Measurement Error of T-score Between Lumbar and Femoral Neck According to Kind of DXA (DXA측정기 종류에 따른 요추부와 대퇴경부 골밀도 값의 측정오차 비교)

  • Han, Beom-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan;Lee, Hye-Nam;Jeong, Cheon-Soo;Lee, Sang-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.250-257
    • /
    • 2010
  • In this study, three different devices, Norland, Osteocore and Lunar were used to compare and analyze the measurement error by each bone density measurement device by classifying the physical characteristics into age, height and weight, the subject of total 300 sampling 100 persons for each device. Categorizing Lumbar region and Femoral neck as normal (T-score$\geqq$-1.0), osteopenia (-1.0>T-score>-2.5) and osteoporosis (T-score$\leqq$-2.5), the findings were observed as follows. Norland device showed the least measurement error in age and height, while Lunar showed the least in weight among the devices. And, the result of comparing the bone density measurement error based on the lumbar region showed that all of Lunar, Norland and Osteocore have the least variation of measurement error in osteopenia and the result of comparing based on the femoral neck showed that all of Lunar, Norland and Osteocore have the least variation of measurement error in osteoporosis. For each variable, the measurement error was observed to be vary upon the device. To solve this, standardized common Phantom should be used to compare and converge the measured value of each company and cross-calibration would be necessary when replacing the software.

The determination of reference material for bone density by using bone phantom (골판톰을 이용한 골밀도측정 참조체의 결정)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.135-139
    • /
    • 2002
  • Purpose: To determine the proper reference step wedge for digital Cu-Equivalent Image analyzing systems for measurement of bone density. Meterials and Methods : Radiograms of lumbar vertebrae phantom (1g/㎠) with 3 test copper step wedges of 0.03, 0.05 and, 0.1 mm thickness unit were taken and analyzed using NIH image software on a Macintosh personal computer. Measured densities of the lumbar areas in the Cu-Equivalent images made by utilizing 3 different copper stepwedges were compared with a known bone density. Results: The values of r2 for all copper equivalent images were over 0.99. The mean Cu-Eq value of lumbar in copper equivalent image made by a 0.1 mm copper stepwedge was 0.22 ± 0.06 mm and converted to hydroxyapatite density of 1.03 g/㎠. The stepwedges of 0.03 and 0.05 mm produced results having higher values than the actual known bone density. They did not show the blue and green color level that appeared in lumbar on color enhanced image. Conclusion : A copper stepwedge of adequate thickness and range of steps which can express the range of density of bone being measured should be used.

  • PDF

Incidence of Osteopenia in Female HBV Carrier and its Correlation with Liver Function Test (B형 간염 보균자에서 골감소증의 빈도 및 간기능검사와의 연관성)

  • Na, Eun-Hui;Park, Jae-Yeong;Kim, Sang-In
    • Journal of Korea Association of Health Promotion
    • /
    • v.3 no.2
    • /
    • pp.181-188
    • /
    • 2005
  • Background : Osteopenia has been recognized as one of potential complication of chronic liver diseases. Its correlation with hepatits B virus(HBV) carrier, however, has not been reported. Thus this study was aimed to clarify the relationship between the osteopenia and HBV carrier. Methods : Bone densities in 192 HBV carrier women and 200 healthy women were measured; the lumbar spine and three sites of the proximal femur(neck, Ward's triangle, greater trochanter) by dual-photon absorptiometry. And liver function tests(AST, ALT, Albumin, GGT, ALP) were also performed. Results : Bone densities at the four sites measured, were significantly correlated with one another(r=0.34 to 0.99, P<0.01). Compared with control group, HBV carriers had significant decreases in bone densities of femur(P<0.05), particularly marked at Ward's triangle. A negative correlations between bone densities and serum total alkaline phosphatase were also found(r=-0.44, P<0.01). Conclusions : Osteopenia was more prevalent in HBV carrier, particularly in the groups before-fifties. Serum total alkaline phosphatase was higher in those with reduced bone densities Thus measurement of bone densities seems to be necessary in female HBV carriers.

  • PDF

Calcium Phosphate Bone Cement Based on Wet Prepared Dicalcium Phosphate

  • Chang, Myung Chul
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.5
    • /
    • pp.480-491
    • /
    • 2018
  • Calcium phosphates (CaP) were prepared by a wet chemical method. Micro-crystalline dicalcium phosphate (DCPD) was precipitated at $37^{\circ}C$ and pH 5.0 using $Ca(OH)_2$ and $H_3PO_4$. The precipitated DCPD solution was kept at $37^{\circ}C$ for 96 h. Artificial bone cement was composed of DCPD, $Ca(H_2PO_4)_2{\cdot}H_2O$ (MCPM), and $CaSO_4{\cdot}1/2H_2O$, $H_2O$ and aqueous poly-phosphoric acid solution. The wet prepared CaP powder was used as a matrix for the bone cement recipe. With the addition of aqueous poly-phosphoric acid, the cement hardening reaction was started and the CaP bone cement blocks were fabricated for the mechanical strength measurement. For the tested blocks, the mechanical strength was measured using a universal testing machine, and the microstructure phase analysis was done by field emission scanning electron microscopy and X-ray diffraction. The cement hardening reaction occurred through the decomposition and recrystallization of MCPM and $CaSO_4{\cdot}1/2H_2O$ added on the surface of the wet prepared CaP, and this resulted in grain growth in the bone cement block.

Measurement of Uncertainty Using Standardized Protocol of Hand Grip Strength Measurement in Patients with Sarcopenia

  • Ha, Yong-Chan;Yoo, Jun-Il;Park, Young-Jin;Lee, Chang Han;Park, Ki-Soo
    • Journal of Bone Metabolism
    • /
    • v.25 no.4
    • /
    • pp.243-249
    • /
    • 2018
  • Background: The aim of this study was to determine the accuracy and error range of hand grip strength measurement using various methods. Methods: Methods used for measurement of hand grip strength in 34 epidemiologic studies on sarcopenia were analyzed. Maximum grip strength was measured in a sitting position with the elbow flexed at 90 degrees, the shoulder in 0 degrees flexion, and the wrist in neutral position (0 degrees). Maximum grip strength in standing position was measured with the shoulder in 180 degrees flexion, the elbow fully extended, and the wrist in neutral position (0 degrees). Three measurements were taken on each side at 30 sec intervals. The uncertainty of measurement was calculated. Results: The combined uncertainty in sitting position on the right and left sides was 1.14% and 0.38%, respectively, and the combined uncertainty in standing position on the right and left sides was 0.35 and 1.20, respectively. The expanded uncertainty in sitting position on the right and left sides was 2.28 and 0.79, respectively, and the expanded uncertainty in standing position on the right and left sides was 0.71 and 2.41, respectively (k=2). Conclusions: Uncertainty of hand grip strength measurement was identified in this study, and a significant difference was observed between measurement. For more precise diagnosis of sarcopenia, dynamometers need to be corrected to overcome uncertainty.

THE CHANGE OF BONE FORMATION ACCORDING TO MAGNETIC INTENSITY OF MAGNET PLACID INTO TITANIUM IMPLANT SPECIMENS (타이타늄 임플랜트 시편 내부에 설치한 자석의 자성강도에 따른 골형성 변화)

  • Hwang Yun-Tae;Lee Sung-Bok;Choi Dae-Gyun;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.232-247
    • /
    • 2005
  • Purpose. The purposes of this investigation were to discover the possibility of clinical application in the areas of dental implants and bone grafts by investigating the bone formation histologically around specimen which was depending on the intensity of magnetic field of neodymium magnet inside of the specimens. Material and method. 1. Measurement of magnetic intensity - placed the magnet inside of the specimen, and measured the intensity of magnetic field around the 1st thread and 3rd thread of specimen 20 times by using a Gaussmeter(Kanetec Co., Japan). 2. Surgical Procedure - Male rabbit was anesthetised by constant amount of Ketamine (0.25ml/kg) and Rompun (0.25ml/kg). After incising the flat part of tibia, and planted the specimens of titanium implant, control group was stitched without magnet, while experimental groups were placed a magnedisc 500(Aichi Steel Co., Japan) or magnedisc 800(Aichi Steel Co., Japan) into it, fixed by pattern resin and stitched. 3. Management after the surgery - In order to prevent it from the infection of bacteria and for antiinflammation, Gentamycin and Ketopro were injected during 1 week from operation day, and dressed with potadine. 4. Preparation of histomorphometric analysis - At 2, 4 and 8 weeks after the surgery, the animals were sacrificed by excessed Ketamine, and then, specimens were obtained including the operated part and some parts of tibia, and fixed it to 10% of PBS buffer solution. After embedding specimens in Technovit 1200 and B.P solution, made a H-E stain. Samples width was 75$\mu$m . In histological findings through the optical microscope and using Kappa image base program(Olympus Co. Japan), the bone contact ratio and bone area ratio of each parts of specimens were measured and analyzed. 5. Statistical analysis - Statistical analysis was accomplished with Mann Whitney U-test. Results and conclusion. 1. In histomorphometric findings, increased new bone formation was shown in both control & experimental groups through the experiment performed for 2, 4 & 8 weeks. After 4 weeks, more osteoblasts and osteoclasts with significant bone remodeling were shown in experimental groups. 2. In histomorphometric analysis, the bone contact ratios were 38.5% for experimental group 1, 29.5% for experimental group 2 and 11.9% for control group. Experimental groups were higher than control group(p<0.05) (Fig. 6, Table IV). The bone area ratios were 60.9% for experimental group 2, 46.4% for experimental group 1 and 36.0% for control group. There was no significantly statistical difference between experimental groups and control group(p<0.05) (Fig. 8, Table VII) 3. In comparision of the bone contact ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group at the 1st thread (p<0.05) and experimental group 1 (1.8mT) was higher than control group at the 3rd thread(p<0.05) (Fig. 7, Table V, VI). 4. In comparision of the bone area ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group and experimental group 1 (4.0mT) at the 1st thread(p<0.1) and experimental group 2(4.4mT) was higher than experimental group 1 (1.8mT) at the 3rd thread(p<0.1) (Fig. 9, Table IX, X). Experiment group 2 was largest, followed by experiment group l and control group at the 3rd thread of implant. There was a significant difference at the 1st thread of control group & experiment group 2, and at 1st thread & 3rd thread of experiment group 1 & 2, and not at control group experiment group 1.(p<0.1)

Bone Mineral Density in Premenopausal Amenorrheic Women with Hypogonadism (폐경전 무월경 여성에 있어서 골밀도 측정에 관한 연구)

  • Park, Ki-Hyun;Lee, Byung-Seok;Lee, Bo-Yon;Cho, Dong-Jae;Song, Chan-Ho
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.19 no.1
    • /
    • pp.49-56
    • /
    • 1992
  • Bone mineral density was measured to assess whether the patients with premonopausal hypogonadism, comprised of 19 patients with hypogonadotropic hypogonadism(HH), 55 with premature ovarian failure(POF), 23 with hyperprolactinemia(HPLN), and 8 with Sheehan's syndrome. All aged from 20 to 39, were associated with some decrease in regional bone mass compared with that of 63 normal-associated with some decrease in regional bone mass compared with that of 63 normal-cycling control women matched with age and sex. Measurement of bone mineral density was carried out using Dual photon absorptiometry at four sites; femur neck, ward's triangle, trochanter and spine(L2-L4). Bone mineral density at all four sites were significantly decreased in patients with HH(p<0.01), POF(p<0.01). In hyperprolactinemic patients, the decrease in bone mass was significant at femur neck and Ward's triangle(p<0.05). The patients with POF were noted to be associated with significant bone loss when their duration of amenorrhea exceeded one year. In this study, the degree of loss of bone mass and the affected sites seemed to be different depending on the various types of hypogonadism and POF was noted have caused the appearance of loss of bone mass earlier than other thpes of hypogondism we experienced.

  • PDF