DOI QR코드

DOI QR Code

Measurement of Uncertainty Using Standardized Protocol of Hand Grip Strength Measurement in Patients with Sarcopenia

  • Ha, Yong-Chan (Department of Orthopaedic Surgery, Chung-Ang University College of Medicine) ;
  • Yoo, Jun-Il (Department of Orthopaedic Surgery, Gyeongsang National University Hospital) ;
  • Park, Young-Jin (Department of Orthopaedic Surgery, Gyeongsang National University Hospital) ;
  • Lee, Chang Han (Department of Rehabilitation Medicine, Gyeongsang National University Hospital) ;
  • Park, Ki-Soo (Department of Preventive Medicine, Gyeongsang National University Hospital)
  • Received : 2018.09.09
  • Accepted : 2018.11.15
  • Published : 2018.11.30

Abstract

Background: The aim of this study was to determine the accuracy and error range of hand grip strength measurement using various methods. Methods: Methods used for measurement of hand grip strength in 34 epidemiologic studies on sarcopenia were analyzed. Maximum grip strength was measured in a sitting position with the elbow flexed at 90 degrees, the shoulder in 0 degrees flexion, and the wrist in neutral position (0 degrees). Maximum grip strength in standing position was measured with the shoulder in 180 degrees flexion, the elbow fully extended, and the wrist in neutral position (0 degrees). Three measurements were taken on each side at 30 sec intervals. The uncertainty of measurement was calculated. Results: The combined uncertainty in sitting position on the right and left sides was 1.14% and 0.38%, respectively, and the combined uncertainty in standing position on the right and left sides was 0.35 and 1.20, respectively. The expanded uncertainty in sitting position on the right and left sides was 2.28 and 0.79, respectively, and the expanded uncertainty in standing position on the right and left sides was 0.71 and 2.41, respectively (k=2). Conclusions: Uncertainty of hand grip strength measurement was identified in this study, and a significant difference was observed between measurement. For more precise diagnosis of sarcopenia, dynamometers need to be corrected to overcome uncertainty.

Keywords

Acknowledgement

Supported by : Ministry of Trade, Industry and Energy (MTIE)

References

  1. Lin DC, Chang JH, Shieh SJ, et al. Prediction of hand strength by hand injury severity scoring system in hand injured patients. Disabil Rehabil 2012;34:423-8. https://doi.org/10.3109/09638288.2011.607550
  2. Eriksen CS, Garde E, Reislev NL, et al. Physical activity as intervention for age-related loss of muscle mass and function: protocol for a randomised controlled trial (the LISA study). BMJ Open 2016;6:e012951. https://doi.org/10.1136/bmjopen-2016-012951
  3. Beseler MR, Rubio C, Duarte E, et al. Clinical effectiveness of grip strength in predicting ambulation of elderly inpatients. Clin Interv Aging 2014;9:1873-7.
  4. Roberts HC, Denison HJ, Martin HJ, et al. A review of the measurement of grip strength in clinical and epidemiological studies: towards a standardised approach. Age Ageing 2011;40:423-9. https://doi.org/10.1093/ageing/afr051
  5. Petersen P, Petrick M, Connor H, et al. Grip strength and hand dominance: challenging the 10% rule. Am J Occup Ther 1989;43:444-7. https://doi.org/10.5014/ajot.43.7.444
  6. Ha YC, Hwang SC, Song SY, et al. Hand grip strength measurement in different epidemiologic studies using various methods for diagnosis of sarcopenia: a systematic review. Eur Geriatr Med 2018;9:277-88. https://doi.org/10.1007/s41999-018-0050-6
  7. Hamilton A, Balnave R, Adams R. Grip strength testing reliability. J Hand Ther 1994;7:163-70. https://doi.org/10.1016/S0894-1130(12)80058-5
  8. Dodds RM, Syddall HE, Cooper R, et al. Global variation in grip strength: a systematic review and meta-analysis of normative data. Age Ageing 2016;45:209-16. https://doi.org/10.1093/ageing/afv192
  9. Beaton DE, O'Driscoll SW, Richards RR. Grip strength testing using the BTE work simulator and the Jamar dynamometer: a comparative study. Baltimore Therapeutic Equipment. J Hand Surg Am 1995;20:293-8. https://doi.org/10.1016/S0363-5023(05)80029-2
  10. Lequin RM. Guide to the expression of uncertainty of measurement: point/counterpoint. Clin Chem 2004;50:977-8. https://doi.org/10.1373/clinchem.2003.030528
  11. Fess EE. A method for checking Jamar dynamometer calibration. J Hand Ther 1987;1:28-32. https://doi.org/10.1016/S0894-1130(87)80009-1
  12. Amaral JF, Mancini M, Novo Junior JM. Comparison of three hand dynamometers in relation to the accuracy and precision of the measurements. Rev Bras Fisioter 2012;16:216-24. https://doi.org/10.1590/S1413-35552012000300007
  13. Chen LK, Lee WJ, Peng LN, et al. Recent advances in sarcopenia research in Asia: 2016 update from the Asian working group for sarcopenia. J Am Med Dir Assoc 2016;17: 767.e1-7. https://doi.org/10.1016/j.jamda.2016.05.016

Cited by

  1. Translation and validation of the Korean version of the Sarcopenia Quality of Life (SarQoL-K®) questionnaire and applicability with the SARC-F screening tool vol.30, pp.2, 2018, https://doi.org/10.1007/s11136-020-02630-2
  2. Handgrip Strength in People With Chronic Obstructive Pulmonary Disease: A Systematic Review and Meta-Analysis vol.101, pp.6, 2018, https://doi.org/10.1093/ptj/pzab057