• 제목/요약/키워드: bone measurement

검색결과 442건 처리시간 0.025초

Reliability of Lateral Deviation Measurement in the Hyoid Bone With Center Point and Lateral Motion Tests

  • Min, Hye-jin;Yoon, Tae-lim
    • 한국전문물리치료학회지
    • /
    • 제26권3호
    • /
    • pp.76-83
    • /
    • 2019
  • Background: The hyoid bone is the only non-jointed structure among the skeletal tissues of the head and neck region, and its movement and posture depend on the attached muscle, ligament, and fascia. The location of the hyoid bone is important for airway maintenance, vocalization, chewing, swallowing, breathing, and head and scapular position. In general, the location of the hyoid bone is measured using radiographs and 3D computed tomography, and no studies have reported on clinical measurement methods. Objects: This study was performed to suggest clinical measurement methods for lateral deviation of the hyoid bone and to evaluate their reliability. Methods: In this study, 24 healthy volunteers (12 males, 12 females) in Cheongju-si participated. Two examiners performed the center point test and lateral motion test twice each to measure the lateral displacement of the hyoid bone. The reliability of the center point test was analyzed using intra-class correlation coefficients (ICC), and the reliability of the lateral motion test was analyzed using Cohen's kappa coefficient. Results: The intra-rater reliability of the center point test was good, and the inter-rater reliability was moderate. The intra- and inter-rater reliability of the lateral motion test showed substantial reliability. Conclusion: Based on these results, the center point test and the lateral motion test can be used as an alternative methods of the measurement of lateral deviation of the hyoid bone for people who have musculoskeletal disorders of the head, neck, and scapula.

골탐침과 방사선학적 및 조직학적 계측의 상관관계 (The correlation of bone probing, radiographic and histometric measurements)

  • 황성준;김창성;이덕연;이용근;조규성;채중규;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제33권4호
    • /
    • pp.615-624
    • /
    • 2003
  • The most accurate method to assess bone level is the histometric measurement. However it causes discomfort in patients and damage to the regenerated tissues. in the present study, we used 4 type regenerative therapies, The present study evaluated the clinical reliability and accuracy of bone probing measurements and radiographic bone level in the assessment of bone level by comparing those results with histometric confirmed bone level. Twentyfour(24) intrabony defects(4${\times}$4mm 1-wall intrabony defects) were surgically created in the mandibular second and fourth premolars of 6 beagle dogs. The control group underwent a conventional flap operation. Experimental group I was treated with calcium phosphate glass only, and while experimental group 2 was treated with GTR and experimental group 3 was treated with calcium phosphate glass and GTR. The subjects were sacrificed 8 weeks after the operation and a bone probing measurements, radiographic measurement and histometric measurement was performed. The correlation between bone probing measurements(BP) and histometric measurement(HL), and radiographic measurement(RL) and histometric measurement(HL) were analyzed with Spearman's rank correlation analysis and the statistical significance with respect to the type of regenerative therapies was analyzed with the Kruskal Wallis test. The coefficient of correlation to HL was 0.73 for RL and 0.90 for BP. The type of regenerative therapies had no significant effect on the difference between HL and other measurements. The results of this study suggests that bone probing measurements most closely represents actual bone level. So bone probing measurements may be a good clinical method for assessing the hone level following any type of periodontal regenerative therapies.

미세 골조직의 공극탄성계수 측정을 위한 예비 연구 (A Pilot study of poroelastic modulus measurement in micro-bone tissue)

  • 박영환;홍정화
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1038-1041
    • /
    • 2004
  • In this study, developed a micro-level experimental setup to measure pore pressure and poroelastic modulus in various strain and strain rate about a stress in micro-structure of bone tissue. It is essential device in the development of the model to analysis the interstitial bone fluid flow of the lacuno-canalicular system to be known that would effect on the bone remodeling. The constitution of the experimental setup is as follows, microscopic image processing system; actuator control unit; load measurement system. A pilot study was used an artificial chemical wood to have similar poroelastic property of bone matrix and conducted to validate the suitability of the measurement system.

  • PDF

골밀도 측정의 올바른 임상 적용 (Clinical Application of Bone Mineral Density Measurement)

  • 김덕윤
    • 대한핵의학회지
    • /
    • 제38권4호
    • /
    • pp.275-281
    • /
    • 2004
  • Compared with the earlier technique of dual photon absorptiometry (DPA) using $^{153}Gd$ radionuclide source, dual energy X-ray absorptiometry (DXA) has advantages of higher precision, accuracy and shorter scanning time. Despite the change from DPA to DPX, the nuclear medicine physicians has remained one of major suplier of this service due to long-standing use of DPA. Among many kinds of bone densitometries, DXA is the "gold standard" for the noninvasive diagnosis of osteoporosis. Especially there is no role for peripheral devices in the monitoring of patients on therapy. But, there are some areas of controversy related to the application of DXA, such as proper site of measurement, accurate interpritation, appropriate use of T-score, and the reference population young database. And the accuracy, precision, and quality control issues relating to bone density measurement are important subjects. To address these issues, the International Society for Clinical Densitometry (ISCD) has convened two Position Development Conferences and addressed official positions. This review deals the key elements of ISCD position paper and other important issues on the management of bone densitometry.

Description of mandibular bone quality based on measurements of cortical thickness using Mental Index of male and female patients between 40-60 years old

  • Hardanti, Sylviana;Azhari, Azhari;Oscandar, Fahmi
    • Imaging Science in Dentistry
    • /
    • 제41권4호
    • /
    • pp.151-153
    • /
    • 2011
  • Purpose : The purpose of this study was to obtain the description of the mandibular bone quality of male and female patients between 40-60 years old and their differences based on mandibular cortical bone thickness measured using Mental Index (MI). Materials and Methods : Forty digital panoramic radiographs, which consisted of twenty male and twenty female patients, 40-60 years old, were observed. Mandibular cortical bone thickness was measured using MI on both sides of the mandible. The average MI score of two groups were then assessed using t-sample independent test. Results : There were significant differences of mandibular bone quality based on mandibular cortical bone thickness measurement using MI between male and female patients (p<0.05). Conclusion : Mandibular bone quality based on cortical bone thickness measurement using MI of male and female patients indicated a significant difference.

골연령의 측정에서 Greulich-Pyle법, Tanner-Whitehouse법, 완관절 초음파 통과속도를 이용한 골연령 측정법의 비교 연구 (Measure of Bone Age through Greulich-Pyle Method, Tanner-Whitehouse Method and Ultrasound Transonic Velocity of Inferior Radiocarpal Joint)

  • 이동형;이진용;김덕곤
    • 대한한방소아과학회지
    • /
    • 제22권2호
    • /
    • pp.69-80
    • /
    • 2008
  • Objectives : The purpose of this study was to evaluate the correlation of 3 methods of bone age measurements. Methods : 102 children(49 boys, 53 girls) were involved in this study. We measured the height, weight and bone age based when they visited for the first time. We measured bone age using BoneAge of Sunlight Co.,Ltd. Two of the bone age measurement methods, Greulich-Pyle and Tanner-Whitehouse, were used to analyze the left dorsopalmar hand-wrist radiographs of 102 children who visited in Department of Pediatrics, O O University Oriental Hospital. This study was designed to investigate the correlation of the bone age between two methods. Results : The bone ages were related with age, height, weight and BMI according to this study(P<0.01). Each bone age assessment method had statistically significant correlation to each other(P<0.01). Conclusions : The ultrasound transonic velocity of inferior radiocarpal joint will become a sufficient diagnostic tool of bone age assessment if measurement error can be minimized by proper effort.

  • PDF

전완부의 골도분촌법에 관한 연구 (A Study on Bone Proportional Measurement of the Forearm)

  • 민원홍;양제윤;양기영;채한;이병렬
    • Korean Journal of Acupuncture
    • /
    • 제35권4호
    • /
    • pp.226-233
    • /
    • 2018
  • Objectives : The purpose of this study was to establish an accurate and effective method of locating acupoints of the forearm by studying bone proportional measurement. Methods : A total of 60 volunteers, 30 men and 30 women, participated in this study. 7 parts of the body were measured by a soft ruler or digital vernier calipers. The cun of the upper limb was calculated and analyzed. And the results were compared with the standard cun. Results : The bone proportional cun of the forearm based on height and femur was close to 11. It was different from the standard 12.5, 12 or 10. The cun of the forearm by thumb or finger width measurement was different from the standard too. Conclusions : We suggest that locating acupoints of the forearm needs to be done based on 11 cun. The confusion on locating acupoints of the forearm will be reduced by reflecting the result of the actual measurement.

체적골밀도 측정법 동향: 수술부위 골밀도 분석 (Volumetric Bone Mineral Density Measurement: for Surgery Specific Bone Volumes)

  • 이연수
    • 한국방사선학회논문지
    • /
    • 제16권1호
    • /
    • pp.53-59
    • /
    • 2022
  • CT영상을 기반으로 한 QCT는 CT장비와 컴퓨터영상처리기술의 발전과 함께 적은 방사선 투과양으로도 체적골밀도를 측정할 수 있는 방향으로 크게 발전하고 있다. 방사선 의료영상을 대표적인 골밀도 측정법인 이중방사선흡수계수법(DXA)은 척추나 근위대퇴골과 다른 뼈와의 상관성이 떨어지는 경우가 많고질량효과에 의한 부정확성의 근본 원인을 가지고 있기 때문에 체적골밀도측정법인 단일에너지CT영상을 이용한 QCT법이 가장 보편적인 정확한 골밀도 측정법이다. 이중에너지CT의 사용은 단단한 뼈와 동시에 종양이나 연부조직의 이상을 같이 볼 수 있는 영상을 얻을 수 있게 되어 QCT 골밀도와 함께 특정연부조직이나 장기를 검사할 수 있어 그 사용이 더욱 늘어날 것으로 예상된다. 임상수술이나 추적검사가 필요한 위치에 사용자가 해부학적으로 특정한 형상체적에 대한 국부골밀도측정 방법도 병원의 임상현장에서 활용할 기술로 대두되고 있다.

초음파 골밀도 측정에서 재현성 향상 방법에 관한 연구 (A Study on Method for Improving Reproducibility in the Ultrasonic Measurement of Bone Mineral Density)

  • 신정식;안중환;김화영;김형준;한승무
    • 대한기계학회논문집A
    • /
    • 제29권10호
    • /
    • pp.1430-1437
    • /
    • 2005
  • It is very important to achieve a high reproducibility in the ultrasonic measurement of bone mineral density. In this study, we examined number of sampling waveform, control of temperature, diameter of region of interest as factors to improve reproducibility. We decided the optimal number of waveforms to be converted to frequency domain as period of 1. We have minimized the effects of variable temperature and constrained generation of micro bubble by keeping temperature within a range of $32\pm0.5^{\circ}C$ with a precise temperature controlling algorithm. We also found the optimal diameter of region of interest to be 13mm. In this paper, we demonstrated the improved reproducibility by controlling various factors affecting the ultrasonic measurement of bone mineral density.

Primary stability of implants with peri-implant bone defects of various widths: an in vitro investigation

  • Yim, Hyun-jin;Lim, Hyun-Chang;Hong, Ji-Youn;Shin, Seung-Il;Chung, Jong-Hyuk;Herr, Yeek;Shin, Seung-Yun
    • Journal of Periodontal and Implant Science
    • /
    • 제49권1호
    • /
    • pp.39-46
    • /
    • 2019
  • Purpose: This study aimed to evaluate the effects of i) the extent of peri-implant bone defects and ii) the application of bone cement on implant stability with respect to the measurement direction. Methods: In 10 bovine rib bones, 4 implant osteotomies with peri-implant bone defects of various widths were prepared: i) no defect (D0), ii) a 2-mm-wide defect (D2), iii) a 4-mm-wide defect (D4), and iv) a 8-mm-wide defect (D8). The height of all defects was 10 mm. Implant stability quotient (ISQ) values and Periotest values (PTVs) were measured after implant placement and bone cement application. Results: With increasing defect width, decreased ISQs and increased PTVs were observed. Statistically significant differences were found between groups D0 and D8, D0 and D4, and D2 and D8. Prior to bone cement application, inconsistent PTVs were found in group D8 depending on the measurement direction. Bone cement increased the implant stability. Conclusion: Peri-implant bone deficits measuring around 50% of the implant surface compromised implant stability. Clinically, PTVs should be cautiously interpreted in implants with large peri-implant defects due to inconsistent recordings with respect to the measurement direction.