• 제목/요약/키워드: bond-slip

검색결과 314건 처리시간 0.022초

Experimental and numerical study on pre-peak cyclic shear mechanism of artificial rock joints

  • Liu, Xinrong;Liu, Yongquan;Lu, Yuming;Kou, Miaomiao
    • Structural Engineering and Mechanics
    • /
    • 제74권3호
    • /
    • pp.407-423
    • /
    • 2020
  • The pre-peak cyclic shear mechanism of two-order asperity degradation of rock joints in the direct shear tests with static constant normal loads (CNL) are investigated using experimental and numerical methods. The laboratory testing rock specimens contains the idealized and regular two-order triangular-shaped asperities, which represent the specific geometrical conditions of natural and irregular waviness and unevenness of rock joint surfaces, in the pre-peak cyclic shear tests. Three different shear failure patterns of two-order triangular-shaped rock joints can be found in the experiments at constant horizontal shear velocity and various static constant normal loads in the direct and pre-peak cyclic shear tests. The discrete element method is adopted to simulate the pre-peak shear failure behaviors of rock joints with two-order triangular-shaped asperities. The rock joint interfaces are simulated using a modified smooth joint model, where microscopic scale slip surfaces are applied at contacts between discrete particles in the upper and lower rock blocks. Comparing the discrete numerical results with the experimental results, the microscopic bond particle model parameters are calibrated. Effects of cyclic shear loading amplitude, static constant normal loads and initial waviness asperity angles on the pre-peak cyclic shear failure behaviors of triangular-shaped rock joints are also numerically investigated.

Retrofitting of squat masonry walls by FRP grids bonded by cement-based mortar

  • Popa, Viorel;Pascu, Radu;Papurcu, Andrei;Albota, Emil
    • Earthquakes and Structures
    • /
    • 제10권1호
    • /
    • pp.125-139
    • /
    • 2016
  • For seismic retrofitting of masonry walls, the use of fibre reinforced cement-based mortar for bonding the fibre grids can eliminate some of the shortcomings related to the use of resin as bonding material. The results of an experimental testing program on masonry walls retrofitted with fibre reinforced mortar and fibre grids are presented in this paper. Seven squat masonry walls were tested under unidirectional lateral displacement reversals and constant axial load. Steel anchors were used to increase the effectiveness of the bond between the fibre grids and the masonry walls. Application of fibre grids on both lateral faces of the walls effectively improved the hysteretic behaviour and specimens could be loaded until slip occurred in the horizontal joint between the masonry and the bottom concrete stub. Application of the fibre grids on a single face did not effectively improve the hysteretic behaviour. Retrofitting with fibre reinforced mortar only prevented the early damage but did not effectively increase deformation capacity. When the boundaries of the cross sections were not properly confined, midplane splitting of the masonry walls occurred. Steel anchors embedded in the walls in the corners area effectively prevented this type of failure.

Thermal-pressure loading effect on containment structure

  • Kwak, Hyo-Gyoung;Kwon, Yangsu
    • Structural Engineering and Mechanics
    • /
    • 제50권5호
    • /
    • pp.617-633
    • /
    • 2014
  • Because the elevated temperature degrades the mechanical properties of materials used in containments, the global behavior of containments subjected to the internal pressure under high temperature is remarkably different from that subjected to the internal pressure only. This paper concentrates on the nonlinear finite element analyses of the nuclear power plant containment structures, and the importance for the consideration of the elevated temperature effect has been emphasized because severe accident usually accompanies internal high pressure together with a high temperature increase. In addition to the consideration of nonlinear effects in the containment structure such as the tension stiffening and bond-slip effects, the change in material properties under elevated temperature is also taken into account. This paper, accordingly, focuses on the three-dimensional nonlinear analyses with thermal effects. Upon the comparison of experiment data with numerical results for the SNL 1/4 PCCV tested by internal pressure only, three-dimensional analyses for the same structure have been performed by considering internal pressure and temperature loadings designed for two kinds of severe accidents of Saturated Station Condition (SSC) and Station Black-out Scenario (SBO). Through the difference in the structural behavior of containment structures according to the addition of temperature loading, the importance of elevated temperature effect on the ultimate resisting capacity of PCCV has been emphasized.

Strain penetration of high-strength steel bars anchored in reinforced concrete beam-column connections

  • Li, Ling;Zheng, Wenzhong;Wang, Ying
    • Structural Engineering and Mechanics
    • /
    • 제72권3호
    • /
    • pp.367-382
    • /
    • 2019
  • This paper presents experimental and analytical investigations on additional fixed-end rotations resulting from the strain penetration of high-strength reinforcement in reinforced concrete (RC) beam-column connections under monotonic loading. The experimental part included the test of 18 interior beam-column connections with straight long steel bars and 24 exterior beam-column connections with hooked and headed steel bars. Rebar strains along the anchorage length were recorded at the yielding and ultimate states. Furthermore, a numerical program was developed to study the effect of strain penetration in beam-column connections. The numerical results showed good agreement with the test results. Finally, 87 simulated specimens were designed with various parameters based on the test specimens. The effect of concrete compressive strength ($f_c$), yield strength ($f_y$), diameter ($d_b$), and anchorage length ($l_{ah}$) of the reinforcement in the beam-column connection was examined through a parametric study. The results indicated that additional fixed-end rotations increased with a decrease in $f_c$ and an increase in $f_y$, $d_b$ and $l_{ah}$. Moreover, the growth rate of additional fixed-end rotations at the yielding state was faster than that at the ultimate state when high-strength steel bars were used.

An approach for partial strengthening of circular RC columns using outer steel tube

  • Hwang, Ju-young;Kwak, Hyo-Gyoung
    • Steel and Composite Structures
    • /
    • 제38권6호
    • /
    • pp.739-749
    • /
    • 2021
  • This paper introduces an improved design equation to evaluate the resisting capacity of circular reinforced concrete (RC) columns partially strengthened with outer steel tube. When RC column members are required to be strengthened according to the change in the loadings considered and/or the deterioration progress in columns, wrapping up RC column with steel circular tube, which takes the form of concrete filled steel tube (CFST), has been popularly considered because of its structural advantage induced from the confinement effect. However, the relatively high construction cost of steel tube is restricting its use to the required region, while deriving the shape of a partial CFST column. To evaluate the resisting capacity of a partial CFST column, numerical analyses need to be performed, and a numerical model proposed in the previous study for the numerical analysis of full CFST columns is used to conduct parametric studies for the introduction of a design equation. The bond-slip effect developed along the interface between the in-filled concrete and the exterior steel tube is taken into consideration and the validity of the numerical model has been established through correlation studies between experimental data and numerical results for partial CFST circular columns. Moreover, parametric studies make it possible to introduce a design equation for determining the optimum length of outer steel tube which produces partial CFST circular columns.

Numerical investigation of the hysteretic response analysis and damage assessment of RC column

  • Abdelmounaim Mechaala;Benazouz Chikh;Hakim Bechtoula;Mohand Ould Ouali;Aghiles Nekmouche
    • Advances in Computational Design
    • /
    • 제8권2호
    • /
    • pp.97-112
    • /
    • 2023
  • The Finite Element (FE) modeling of Reinforced Concrete (RC) under seismic loading has a sensitive impact in terms of getting good contribution compared to experimental results. Several idealized model types for simulating the nonlinear response have been developed based on the plasticity distribution alone the model. The Continuum Models are the most used category of modeling, to understand the seismic behavior of structural elements in terms of their components, cracking patterns, hysteretic response, and failure mechanisms. However, the material modeling, contact and nonlinear analysis strategy are highly complex due to the joint operation of concrete and steel. This paper presents a numerical simulation of a chosen RC column under monotonic and cyclic loading using the FE Abaqus, to assessthe hysteretic response and failure mechanisms in the RC columns, where the perfect bonding option is used for the contact between concrete and steel. While results of the numerical study under cyclic loading compared to experimental tests might be unsuccessful due to the lack of bond-slip modeling. The monotonic loading shows a good estimation of the envelope response and deformation components. In addition, this work further demonstrates the advantage and efficiency of the damage distributions since the obtained damage distributions fit the expected results.

Finite element modeling of reinforced concrete beams externally bonded with PET-FRP laminates

  • Rami A. Hawileh;Maha A. Assad;Jamal A. Abdalla; M. Z. Naser
    • Computers and Concrete
    • /
    • 제33권2호
    • /
    • pp.163-173
    • /
    • 2024
  • Fiber-reinforced polymers (FRP) have a proven strength enhancement capability when installed into Reinforced Concrete (RC) beams. The brittle failure of traditional FRP strengthening systems has attracted researchers to develop novel materials with improved strength and ductility properties. One such material is that known as polyethylene terephthalate (PET). This study presents a numerical investigation of the flexural behavior of reinforced concrete beams externally strengthened with PET-FRP systems. This material is distinguished by its large rupture strain, leading to an improvement in the ductility of the strengthened structural members compared to conventional FRPs. A three-dimensional (3-D) finite element (FE) model is developed in this study to predict the load-deflection response of a series of experimentally tested beams published in the literature. The numerical model incorporates constitutive material laws and bond-slip behavior between concrete and the strengthening system. Moreover, the validated model was applied in a parametric study to inspect the effect of concrete compressive strength, PET-FRP sheet length, and reinforcing steel bar diameter on the overall performance of concrete beams externally strengthened with PET-FRP.

디지털 이미지 분석을 통한 지속 하중과 온도의 복합 환경이 CFRP 쉬트와 콘크리트의 부착강도 및 크리프 거동에 미치는 영향 분석 (Combined Effects of Sustained Load and Temperature on Pull-off Strength and Creep Response between CFRP Sheet and Concrete Using Digital Image Processing)

  • 정유석;이재하;김우석
    • 콘크리트학회논문집
    • /
    • 제28권5호
    • /
    • pp.535-544
    • /
    • 2016
  • 본 연구에서는 디지털 이미지를 사용하여 DIC(Digital Image Correlation) 기법 및 부착파괴면 분석을 통해 부착파괴에너지와 부착강도의 정량적 분석뿐만 아니라 계면의 부착 면 파괴 양상의 정성적 접근을 통해 지속 하중과 온도의 복합 하중에 대한 FRP 부착 실험체의 거동을 분석하였다. 이를 위해 CFRP 쉬트를 부착한 일면전단실험체를 제작하여 사용하였다. 일면전단실험체의 지속 하중 기간의 거동은 에폭시 크리프의 영향을 상당히 받으며 지속 하중 기간 동안에 에폭시의 점탄성 특징으로 인해 응력완화가 발생하였다. 응력완화는 지속 하중 이후 실시한 계면전단실험에서 사용한 DIC 기법을 통해 관찰 하였으며 지속하중 기간 동안의 응력완화로 인해 지속하중 실험체의 최대부착파괴하중 및 계면파괴에너지가 대조실험체보다 증가하였다. 모든 실험체의 부착 파괴 면을 디지털 이미지화하여 파괴 면의 양상을 정성적/정량적으로 분석 하였다. 디지털 이미지 분석 결과 지속 하중 기간 동안 파괴 형태가 콘크리트면내파괴에서 계면부착파괴 형태로 전이가 발생하였으며 이러한 전이로 인해 지속하중 기간이 증가할수록 지속하중의 최대부착파괴하중에 대한 긍정적인 효과 감소하였다.

지진하중을 받는 주철근 겹침이음된 철근콘크리트 교각의 곡률분석 (Experimental Curvature Analysis of Reinforced Concrete Piers with Lap-Spliced Longitudinal Steels subjected to Seismic Loading)

  • 정영수;박창규;송희원
    • 한국지진공학회논문집
    • /
    • 제10권1호
    • /
    • pp.41-49
    • /
    • 2006
  • 지난 1982년 우라카와 근해지진 및 1995년 효고현 남부 지진 등에 의하여 주철근이 겹침이음된 많은 교각들이 주철근 겹침이음부의 활동에 의한 휨-전단파괴를 발생하였음을 경험하였다. 철근콘크리트 교각의 내진성능은 소성힌지구간의 변형능력에 좌우되고 있으며, 이는 곡률연성도로서 평가된다. 우리나라에서는 1992년 내진 설계가 도입된 이후 철근콘크리트 교각의 주철근겹침이음에 대한 규정이 없었으나, 2005년 도로교 설계기준에서 주철근겹침음을 50% 이내에서 허용하고 있다. 본 연구는 단면 직경이 600 mm이고 형상비가 2.5 및 3.5인 주철근 겹침이음이 있는 철근콘크리트 교각에 대하여 지진시 소성힌지부의 곡률분포 및 곡률연성도에 대하여 조사하였다. 실험은 일정한 축력 $P=0.1f{ck}A_g$가 재하된 상태에서 변위제어 방식으로 준정적실험을 실시하였다. 실험결과 반복하중에 의한 주철근 겹침이음부에 활동이 발생하면, 주철근 겹침이음 구간 내의 곡률이 주철근 겹침이음이 없는 경우와 다르게 나타났다. 다시 말하면 주철근 겹침이음 실험체의 겹침이음 구간 중의 하부 곡률은 주철근 겹침이음이 없는 실험체의 경우보다 큰 값을 보이고 있으며, 상부는 작은 값을 보였다. 이로 인하여 교각실험체의 손상은 겹침이음 구간의 하부에 집중되어 휨파괴되는 모습으로 보이는 양상을 보였다.

중심축 하중을 받는 각형 CFT 기둥의 장기거동에 관한 연구 (Long-Term Behavior of Square CFT Columns under Concentric Load)

  • 권승희;김태환;이태규;김윤용
    • 콘크리트학회논문집
    • /
    • 제17권2호
    • /
    • pp.281-290
    • /
    • 2005
  • 이 연구에서 중심축 하중을 받는 각형 CFT 기둥의 장기거동에 관한 실험과 해석을 수행하였으며, 이를 통해 각형 CFT 기둥의 장기거동을 예측할 수 있는 방법을 모색하고 그 거동 특성을 파악해 보고자 하였다. 중심축 하중에 대해 두 가지 가압 방법이 고려되었다. 첫째는 콘크리트에만 하중이 가해지는 경우이고, 둘째는 콘크리트와 강관에 동시에 하중이 가해지는 경우이다. 각형 CFT 기둥 실험체에 대한 삼차원 유한요소 모델로 해석을 수행하였으며, 해석결과는 실험결과를 매우 정확히 모사하였다. 따라서 강관과 콘크리트의 부착거동을 고려한 3차원 유한요소 모델링으로부터 실제 각형 CFT 기둥에 대한 장기거동 예측이 가능할 것으로 판단된다. 또한 실험과 해석결과로부터 다음의 거동 특성을 파악하였다. 콘크리트에만 하중이 가해지는 경우 구속압에 의해 유발되는 부착응력은 시간에 따라 증가하며, 강관과 콘크리트 사이의 미끄럼 또한 시간에 따라 증가한다. 강관에 의한 구속압은 시간에 따라 증가하는 반면. 가압판에 의한 구속압은 시간에 따라 감소한다. 강관과 콘크리트에 동시에 하중이 가해지는 경우 강관에 의한 콘크리트의 구속 효과와 미끄럼은 발생하지 않는다.