• 제목/요약/키워드: bond zone

검색결과 124건 처리시간 0.028초

Response of lap splice of reinforcing bars confined by FRP wrapping: modeling approach

  • Thai, Dam Xuan;Pimanmas, Amorn
    • Structural Engineering and Mechanics
    • /
    • 제37권1호
    • /
    • pp.95-110
    • /
    • 2011
  • This paper presents a tri-uniform bond stress model for predicting the lap splice strength of reinforcing bar at the critical bond splitting failure. The proposed bond distribution model consists of three zones, namely, splitting zone, post-splitting zone and yielding zone. In each zone, the bond stress is assumed to be constant. The models for bond strength in each zone are adopted from previous studies. Combining the equilibrium, strain-slip relation and the bond strength model in each zone, the steel stress-slip model can be derived, which can be used in the nonlinear frame analysis of the column. The proposed model is applied to derive explicit equations for predicting the strength of the lap splice strengthened by fiber reinforced polymer (FRP) in both elastic and post-yield ranges. For design purpose, a procedure to calculate the required FRP thickness and the number of FRP sheets is also presented. A parametric investigation was conducted to study the relation between lap splice strength and lap splice length, number and thickness of FRP sheets and the ratio of concrete cover to bar diameter. The study shows that the lap splice strength can be enhanced by increasing one of these parameters: lap splice length, number or thickness of FRP sheets and concrete cover to bar diameter ratio. Verification of the model has been conducted using experimental data available in literature.

단일용기 상아질 접착제 처리 후 레진-상아질 경계면에 대한 투과전자현미경적 연구 (A TEM STUDY OF THE RESIN-DENTIN INTERDIFFUSION ZONE FORMED BY ONE-BOTTLE DENTIN ADHESIVE SYSTEMS)

  • 양동운;박성호;이찬영
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.180-192
    • /
    • 2000
  • One bottle system was recently developed in order to simplify the clinical skills and save chair time after continuous improvements on dentin bonding agents. There has been many studies to measure the bond strength of one bottle systems but no actual work has been done on micromorphologic study of resin-dentin interdiffusion zone after one bottle system application. To evaluate the bonding patterns of various commercially available one bottle systems to dentin, observation of resin-dentin interdiffusion zone under TEM was performed. Caries-free human third molars within one month of extractions were chosen for the experiments. The molars were sectioned 1mm above the cementoenamel junction and got rid of the root portions. Crown portions of the teeth were sectioned parallel to occlusal surface so that dentin discs of 1mm in thickness were remained. 7 one bottle systems and 1 two bottle system were applied according to manufacturer's instructions and followings were the results. 1. In every experimental groups, cross bandings of collagen fiber were distinguishable and tight bon dings between the bonding agents and dentin were observed. 2. Hybrid layer was clearly observed in ONE-STEP$^{(R)}$, Prime & Bond$^{(R)}$ 2.1, Syntac$^{(R)}$ SC, MAC-BOND II groups but it was not clear in Single Bond, D-Liner Dual PLUS, ONE COAT BOND groups. 3. Electron-density of hybrid layer was uniform in pattern in MAC-BOND II, Prime & Bond$^{(R)}$ 2.1 groups but not so uniform in ONE-STEP$^{(R)}$ group. 4. Electron-dense amorphous phase in most superior layer of the resin-dentin interdiffusion zone was characteristically observed in Single Bond, Syntac$^{(R)}$ SC, ONE COAT BOND groups. It can be concluded that bondings between the dentin bonding agents and dentin can be various in pattern according to their chemical compositions and the condition during applications.

  • PDF

PS 강선의 정착부착성능에 관한 해석 모델 (Analytical Model for Transfer Bond Performance of Prestressing Strands)

  • 유승룡
    • 콘크리트학회지
    • /
    • 제6권4호
    • /
    • pp.92-101
    • /
    • 1994
  • PS 강선의 정착부착성능에 대한 새로운 해석방법을 소개하였다. 이 모델에서, 정착부착 길이는 탄생 영역과 소성영역으로 구분되었다. 탄성영역에서 부착응력은 최대 부착응력에 도달된 때까지 슬립과 비례하여 증가하고, 소성영역에선 최대 부착응력으로 균일하게 분포됨을 가정하였다. 정착부착 길이 내에서 부착응력, 슬립, 강선응력, 콘크리트응력 분포를 결과를 얻을 수 있었고, 전체 정착부착 길이와 자유단에서 슬립에 대한 결과치는 최근 Cousins et al.의 실험 결과치와 유사하였다.

Al-Si 용융 도금된 보론강 CO2 레이저 용접부의 미세조직과 기계적 성질에 미치는 핫스탬핑 처리의 영향 (Effect of Hot-Stamping on Mechanical Properties and Microstructures of CO2 Laser Welded Boron Steel coated with Al-Si layer)

  • 오명환;공종판;신현정;권민석;정병훈;강정윤
    • 한국레이저가공학회지
    • /
    • 제16권3호
    • /
    • pp.1-10
    • /
    • 2013
  • In this study, Al-Si coated boron steel(1.2 mm) were laser welded by $CO_2$ laser and hot-stamping was applied to the laser joints. Tensile properties and microstructures of the joints were investigated before and after hot-stamping. Tensile and yield strengths of the as welded specimen similar with base metal and fracture occurred base metal of boron steel. Although, in case of heat treated specimen, fracture occurred fusion zone that Al segregated zone near the bond line. These could be explained by the existence of ferrite, in the Al segregated zone near the bond line and base metal of boron steel. Before hot-stamping, hardness of base metal is lower than fusion zone and heat affected zone in spite of exist Al segregation zone($Fe_3$(Al,Si)). So fracture occurred base metal. Although, after hot-stamping, microstructure of base metal and welds zone transformed to martensite and bainite except in Al segregation zone near the bond line that $Fe_3$(Al,Si) transformed to a-ferrite. So fracture occurred Al segregation zone near the bond line.

  • PDF

구조용(構造用) 합금강(合金鋼) 용접(熔接) 각부위(各部位)의 열처리(熱處理)에 따른 기계적(機械的) 성질(性質) 변화(變化)에 관(関)한 실험적(實驗的) 연구(硏究) (Influence of Heat Treatment on the Mechanical Properties in Various Weld Zone of the Structural Alloy Steel)

  • 심상우;이승규;민영봉
    • Journal of Biosystems Engineering
    • /
    • 제10권1호
    • /
    • pp.76-82
    • /
    • 1985
  • To investigate the influence of annealing heat treatment on the mechanical properties at the various weld zone, an experimental study was performed for the structural alloy steel. The results obtained from the experimental works are as follows: 1. Hardness and tensile strength showed the highest value at the heat affected zone, which was 5mm apart from bond zone. With increasing of annealing temperature, hardness and tensile strength were decreased at every weld zone, and bound in heat affected zone was increased. 2. Impact strength was the highest at the filler metal, and increased with increment of annealing temperature at filler metal and base metal. However, both at bond and heat affected zones, impact strength was increased from $700^{\circ}C$ of annealing temperature, and was decreased again over $900^{\circ}C$. 3. Mutual relationship between the mechanical properties at filler and base metals showed a similar linearty to that the common structural steel did. However, it varied unsteadly both at bond and heat affected zones. 4. It may be concluded that proper annealing temperature is $700^{\circ}C$ from the viewpoint of hardness, tensile and impact strength.

  • PDF

Finite element parametric study of RC beams strengthened with carbon nanotubes modified composites

  • Irshidat, Mohammad R.;Alhusban, Rami S.
    • Computers and Concrete
    • /
    • 제27권2호
    • /
    • pp.131-141
    • /
    • 2021
  • This paper aims at investigating the capability of different FRP/concrete interface models to predict the effect of carbon nanotubes on the flexural behavior of RC beams strengthened with CFRP. Three different interfacial bond models are proposed to simulate the adhesion between CFRP composites and concrete, namely: full bond, nonlinear spring element, and cohesive zone model. 3D Nonlinear finite element model is developed then validated using experimental work conducted by the authors in a previous investigation. Cohesive zone model (CZM) has the best agreement with the experimental results in terms of load-deflection response. CZM is the only bond model that accurately predicted the cracks patterns and failure mode of the strengthened RC beams. The FE model is then expanded to predict the effect of bond strength on the flexural capacity of RC beams strengthened with externally bonded CNTs modified CFRP composites using CZM bond model. The results reveal that the flexural capacity of the strengthened beams increases with increasing the bond strength value. However, only 23% and 22% of the CFRP stress and strain capacity; in the case of full bond; can be utilized before failure.

지반개량에 의한 Anchor 정착부 개선효과 사례연구 (A Case Study on the Effect of Soil Improvement on Anchor Bond Zone)

  • 김태섭;송상호;조규완;이재동
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1008-1013
    • /
    • 2006
  • Ground anchor method is widely used in the large scale deep excavation of urban area to support a retained wall. Excavation using the ground anchor as a supporting system near a building have many difficulties due to the limitation of construction space. This method can not be applied to the site with the insufficient space from the retained wall to the boundary line. In this case, soil improvement at the anchor bond zone can be used to secure the frictional resistance of ground anchor within the boundary. Through this method, the bond length of anchor can be shortened considerably. This paper deals with the case study on the ground excavation adjacent to a building. The object field is Yongsan Park Tower Construction Site. In this site, the enlarged anchor with soil improvement was applied to solve the problem due to the limitation of construction space. According to the results of field test and monitoring, the anchor with soil improvement is very effective to secure the frictional resistance at the anchor bond zone.

  • PDF

철근 콘크리트 부재의 부착거동에 관한 실험적 연구 (An Experimental Investigation on the Bond Characteristics of Reinforced Concrete Structure)

  • 오병환;이성로;방기성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 봄 학술발표회 논문집
    • /
    • pp.122-127
    • /
    • 1990
  • The transfer of forces across the interface by bond between concrete and steel is of fundamental importance to many aspects of reinforced concrete behavior. Bond stress - slip relationships were studied using a symmetrical tension test specimen. This type of test is intented to simulate conditions in the tension zone of a concrete beam between primary cracks and below the neutral axis. These relationships between local bond stress and local slip are quite different at different locations along the bar. The present study allows more accurate analysis of reinforced concrete structures by employing more realistic bond stress-slip relations.

  • PDF

Antibacterial effect of self-etching adhesive systems on Streptococcus mutans

  • Kim, Seung-Ryong;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • 제39권1호
    • /
    • pp.32-38
    • /
    • 2014
  • Objectives: In this study, we evaluated the antibacterial activity of self-etching adhesive systems against Streptococcus mutans using the agar diffusion method. Materials and Methods: Three 2-step systems, Clearfil SE Bond (SE, Kuraray), Contax (CT, DMG), and Unifil Bond (UnB, GC), and three 1-step systems, Easy Bond (EB, 3M ESPE), U-Bond (UB, Vericom), and All Bond SE (AB, BISCO) were used. 0.12% chlorhexidine (CHX, Bukwang) and 37% phosphoric acid gel (PA, Vericom) were used as positive controls. Results: The antibacterial activity of CHX and PA was stronger than that of the other groups, except SE. After light activation, the inhibition zone was reduced in the case of all 2-step systems except CT. However, all 1-step systems did not exhibit any inhibition zone upon the light activation. Conclusions: SE may be better than CT or UnB among the 2-step systems with respect to antibacterial activity, however, 1-step systems do not exhibit any antibacterial activity after light curing.

Al-Si 도금된 보론강 레이저 소스에 따른 레이저 용접부의 미세조직과 기계적 성질에 미치는 핫스탬핑 처리의 영향 (Effect of Hot-stamping on Microstructures and Tensile Properties of Al-Si Coated Boron Steel Welds with Laser Source)

  • 오명환;공종판;권민석;강정윤
    • Journal of Welding and Joining
    • /
    • 제31권6호
    • /
    • pp.96-106
    • /
    • 2013
  • In this study, the effect of laser source($CO_2$ and Nd:YAG) on the microstructure and tensile properties of laser welded Al-Si coated boron steel(1.2mmt) was investigated with before and after hot-stamping. In case of as welds condition, fracture occurred in base metal unrelated to the laser source. It could be explained that tensile strength of fusion zone composed of martensite and bainite is higher than that of base metal that contains a lot of ferrite despite dilution of Al and Si from coating layer to fusion zone. In case of hot-stamping condition, the fracture occurred in fusion zone irrelevant to laser source and the tensile strength was lower than hot stamped base metal. In the $CO_2$ laser welds, $Fe_3$(Al,Si) formed near the bond line was transformed into ferrite during hot-stamping. Therefore tensile strength of bond line is lower than that of base metal and center of fusion zone and the fracture occurred in the bond line. On the other hand, in the Nd:YAG laser welds, the higher concentration of Al formed the ferrite in the fusion zone during hot-stamping treatment. Also, the thickness of centerline was thinner than that of base metal. Therefore, it is considered that fracture occurred in centerline of fusion zone due to effect of concentration stress, and it leaded to a lower tensile strength and elongation.