• 제목/요약/키워드: bond shear stress

검색결과 148건 처리시간 0.024초

1면과 2면 인장전단 실험 방법에 따른 부착성능에 관한 실험적 연구 (Experimental Study by Single and Double Face Shear Test of Bond Ability between Carbon Fiber Reinforced Plate and Concrete.)

  • 강대언;우현수;최기선;양원직;유영찬;이원호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.315-318
    • /
    • 2005
  • The objective of this study is to find out discrepancy in ability of bond behavior between Carbon fiber-reinforced polymer(CFRP Plate) and concrete by method of experiment. For the objective, single and double face shear test were tested. From the experimental results, it was analyzed bond strength of FRP to concrete, distribution of stress and strain of FRP. The bond strength and the effective bond length was evaluated by the theory of existing studies. Effective bond length of single face test was smaller than it of double face test.

  • PDF

Bond-Strengthening Hooks for RC Members with High Strength Spirals

  • Kim Kil-Hee;Sato Yuichi
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.835-842
    • /
    • 2005
  • This paper presents an experimental investigation of bond-strengthening hooks as a new method to increase bond strength along flexural reinforcing bars in reinforced concrete (RC) beams and columns. The RC members, which consisted of 1,300 MPa-class spirals as shear reinforcement, often suffered from bond splitting failure. The proposed method attempts to increase confining stiffness around the flexural bars by placing U-shaped hooks and to prevent premature bond splitting failure. Twelve specimens with varied amounts and sizes of the hooks were prepared to verify the strengthening effectiveness under monotonic and cyclic loading conditions. The test result indicated that the hooks increased the bond strength along the flexural bars although the strengthening effectiveness was limited by effective reinforcement ratio $P_{be}$. This limit is determined by size of stress-transmitting zones of concrete around anchors of the hooks. Anchors of the hooks are recommended to be longer than twelve times the hook diameter and inserted deeper than a quarter of the member depth (D/4). Proposed design equations provide modest estimates of the shear strengths.

부착길이와 복부정착이 CFRP판으로 보강된 RC 보의 휨 보강효과에 미치는 영향 (Effect of Bond Length and Web Anchorage on Flexural Strength in RC Beams Strengthened with CFRP Plate)

  • 박상렬
    • 콘크리트학회논문집
    • /
    • 제14권5호
    • /
    • pp.645-652
    • /
    • 2002
  • 본 논문은 탄소 FRP 판을 이용한 철근 콘크리트 보의 휨 보강효과와 거동에 대한 연구이다. 본 연구에서의 실험인자로는 휨보강 탄소 FRP 판의 부착길이와 탄소 FRP 쉬트의 복부정착 길이이다. 시험보는 탄소 FRP 판으로 인장면에 부착하여 휨 보강하고 FRP 판을 탄소 FRP 쉬트로 복부에 정착하였다. 일반적으로 복부정착이 없는 휨 보강된 보들의 파괴형태는 횡방향 주철 근을 따라 발생한 콘크리트 덮개 박리파괴를 나타내었다. 반면, 탄소 FRP 쉬트로 복부 정착된 휨 보강 보들은 CFRP 파단파괴 후 콘크리트 경계면 전단 박리파괴를 나타내었다. 보강된 보들의 극한하중과 극한처짐은 FRP 판의 휨 부착길이의 증가에 따라 증가하였다. 또한, 휨 보강된 보들은 FRP 쉬트의 복부정착 길이의 증가에 따라 극한하중과 극한처짐 값이 증가하였다. 특히, 복부 정착한 보들은 최대 극한하중에 도달한 후에도 상당한 극한하중 지지능력을 상당한 극한 처짐 시까지 유지하였다. 시험보의 길이에 걸친 FRP 판의 변형률 분포는 휨 모멘트도의 모양과 거의 유사하여 전단지간에서 일정한 전단응력 분포를 가정할 수 있었다. 전지간을 휨 보강한 보에 있어서는 콘크리트와 FRP 쉬트에 의한 경계면에서의 극한전단 저항강도는 복부정착 길이가 늘어남에 따라 증가하였다. 전단 저항강도 중에서 본 실험에서 사용한 복부 정착 FRP 쉬트도 일부의 전단 저항강도를 부담하였다.

트러스 데크를 사용한 강판성형 합성보의 휨성능 평가 (Flexural Capacity of the Profiled Steel Composite Beams with Truss Deck Plate)

  • 허병욱;곽명근;배규웅;정상민;강석규
    • 한국강구조학회 논문집
    • /
    • 제19권4호
    • /
    • pp.413-423
    • /
    • 2007
  • 기존의 층고절감형 합성보 시스템은 철골보의 웨브면에 바닥판을 삽입하여 시공하기 때문에 상대적으로 기존 합성보 형식과 비교하여 층고를 대폭적으로 줄일 수 있지만, 적용되는 철골보 춤이 제한되기 때문에 적용 가능한 스팬이 한정되어 있어 여러 가지 다양한 건축구조의 수요에 능동적으로 대처하기가 어려운 단점이 있다. 따라서, 본 연구에서는 기존의 층고절감형 합성보의 단점을 해결하기 위하여 합성보의 춤을 자유로이 조절할 수 있는 층고절감형 매입형 합성보를 개발하였다. 본 연구는 콘크리트에 매입된 강팡성형 철골보를 가지는 불완전 합성보의 휨거동에 관한 것이다. 총 5개의 실대형 실험체를 전단연결재 및 보강근의 사용유무, 슬래브 형식을 주요변수로 하여 실험을 수행하였다. 실험결과, 별도의 전단연결재를 설치하지 않은 실험체는 자체가 가지고 있는 기계적 화학적 부착응력으로 인해 $0.20{\sim}0.76N/mm^2$의 부착응력을 나타내었다.

Experimental investigation of natural bond behavior in circular CFTs

  • Naghipour, Morteza;Khalili, Aidin;Hasani, Seyed Mohammad Reza;Nematzadeh, Mahdi
    • Steel and Composite Structures
    • /
    • 제42권2호
    • /
    • pp.191-207
    • /
    • 2022
  • Undoubtedly, the employment of direct bond interaction between steel and concrete is preceding the other mechanisms because of its ease of construction. However, the large scatter in the experimental data about the issue has hindered the efforts to characterize bond strength. In the following research, the direct bond interaction and bond-slip behavior of CFTs with circular cross-section were examined through repeated load-reversed push-out tests until four cycles of loading. The influence of different parameters including the diameter of the tube and the use of shear tabs were assessed. Moreover, the utilization of expansive concrete and external spirals was proposed and tested as ways of improving bond strength. According to the results section dimensions, tube slenderness, shrinkage potential of concrete, interface roughness and confinement are key factors in a natural bond. Larger diameters will lead to a considerable drop in bond strength. The use of shear tabs by their associated bending moments increases the bond stress up to eight times. Furthermore, employment of external spirals and expansive concrete have a sensible effect on enhancing bonds. Macro-locking was also found to be the main component in achieving bond strength.

Analytical model for flexural and shear strength of normal and high-strength concrete beams

  • Campione, Giuseppe
    • Structural Engineering and Mechanics
    • /
    • 제78권2호
    • /
    • pp.199-207
    • /
    • 2021
  • In the present paper, an analytical model is proposed to determine the flexural and shear strength of normal and high-strength reinforced concrete beams with longitudinal bars, in the presence of transverse stirrups. The model is based on evaluation of the resistance contribution due to beam and arch actions including interaction with stirrups. For the resistance contribution of the main bars in tension the residual bond adherence of steel bars, including the effect of stirrups and the crack spacing of R.C. beams, is considered. The compressive strength of the compressed arch is also verified by taking into account the biaxial state of stresses. The model was verified on the basis of experimental data available in the literature and it is able to include the following variables in the resistance provision: - geometrical percentage of steel bars; - depth-to-shear span ratio; - resistance of materials; - crack spacing; - tensile stress in main bars; - residual bond resistance including the presence of stirrups;- size effects. Finally, some of the more recent analytical expressions able to predict shear and flexural resistance of concrete beams are mentioned and a comparison is made with experimental data.

충전각형강관기둥에서 콘크리트와 강관의 부착응력에 관한 해석적 연구 (An Analytic Study on the Bond Stress between Concrete and Steel Tube in CFT Rectangular Column)

  • 박성무;강주원;김원호;이형석
    • 한국공간구조학회논문집
    • /
    • 제2권4호
    • /
    • pp.53-60
    • /
    • 2002
  • An analytic study on the bond stress between steel tube and concrete in concrete filled steel(CFT) rectangular column is presented in this paper. Recently buildings need members which are enhanced durability and ductility. Concrete filled rectangular column system is proposed as alternative plan. In this paper, ABAQUS/Standard Version 5.8 which is identified as usefulness for finite element analysis and has various element library is used. The variables in this study are the location and type of shear-connector. The modeling on contact problem practiced by Contact Pair and Contact Pressure method. In the step of physical bond, it is practiced by Change friction option After yielding of models, analytic results is less than that of experimental results.

  • PDF

An analytical analysis of the pullout behaviour of reinforcements of MSE structures

  • Ren, Feifan;Wang, Guan;Ye, Bin
    • Geomechanics and Engineering
    • /
    • 제14권3호
    • /
    • pp.233-240
    • /
    • 2018
  • Pullout tests are usually employed to determine the ultimate bearing capacity of reinforced soil, and the load-displacement curve can be obtained easily. This paper presents an analytical solution for predicting the full-range mechanical behavior of a buried planar reinforcement subjected to pullout based on a bi-linear bond-slip model. The full-range behavior consists of three consecutive stages: elastic stage, elastic-plastic stage and debonding stage. For each stage, closed-form solutions for the load-displacement relationship, the interfacial slip distribution, the interfacial shear stress distribution and the axial stress distribution along the planar reinforcement were derived. The ultimate load and the effective bond length were also obtained. Then the analytical model was calibrated and validated against three pullout experimental tests. The predicted load-displacement curves as well as the internal displacement distribution are in closed agreement with test results. Moreover, a parametric study on the effect of anchorage length, reinforcement axial stiffness, interfacial shear stiffness and interfacial shear strength is also presented, providing insights into the pullout behaviour of planar reinforcements of MSE structures.

전단접착강도와 탈락양상을 고려한 브라켓-접착제의 선택 (A Study on Bracket-Adhesive Combinations in Aspect of Shear Bond Strength and Bond Failure)

  • 한재익;손우성
    • 대한치과교정학회지
    • /
    • 제28권6호
    • /
    • pp.955-974
    • /
    • 1998
  • 적절한 전단접착강도를 가지면서 법랑질손상과 브라켓파절을 적게 일으키는 브라켓-접착제의 그룹을 찾아내기 위하여 전단접착강도, 법랑질손상, 브라켓탈락양상, 브라켓 주위의 밀봉과 법랑질-접착제-브라켓 사이의 긴밀도를 연구하였다. 교정치료 목적으로 발치한 240개의 치아를 각각 10개씩 24개의 군으로 나누어서 브라켓을 접착한 후 48시간 후에 전단접착강도를 측정하고 브라켓 탈락 양상을 조사하였다. 또한 브라켓 주위의 밀봉과 법랑질-접착제-브라켓 사이의 긴밀도를 평가하기 위하여 브라켓이 접착된 치아를 반으로 자른 후 주사전자현미경상에서 관찰하였다. 6종류의 브라켓과 4종류의 접착제가 사용되었으며 브라켓은 Image, Plastic, Crystaline, Fascination, Transcend, metal bracket을 사용하였으며 접착제로는 No-mix, Light-Bond, OrthoLC, Superbond C&B가 사용되었다. 이와같은 연구로부터 다음과 같은 결론을 내렸다. 1. 전단접착강도는 Fascination-Light Bond 군에서 36.58 Kg(410.07 Kg/$cm^2$)으로 가장 높았으며 Image-OrthoLC 군에 서 8.93 B◎ (75.51 Kg/$cm^2$)으로 가장 낮았다. OrthoLC를 접착제로 사용하였을 때 전단접착강도는 다른 접착제를 사용하였을 때 보다 비교적 낮았다. 2. 접착제의 종류에 관계없이 Fascination bracket의 전단접착강도는 비교적 높았으며 Image, Plastic bracket의 전단접착강도는 비교적 낮았다. Crystaline, Transcend bracket의 전단접착강도는 metal bracket의 전단접착강도와 비슷하거나 낮았다. 3. 전단접착강도와 법랑질 파절, 브라켓 파절은 상관관계가 있었으며, 접착강도가 증가할수록 법랑질 파절과 브라켓 파절은 증가하였다. 4. OrthoLC를 접착제로 사용하였을 때 법랑질 파절과 브라켓 파절은 일어나지 않았으나 Superbond C&B를 접착제로 사용하였을 때는 법랑질 파절과 브라켓 파절의 빈도가 높았다. 5. No-mix, Light-Bond를 접착제로 사용하였을 때 브라켓 주위의 밀봉과 법랑질-접착제-브라켓의 긴밀도는 양호하였다. 접착제의 종류에 관계없이 Ceramic bracket에서 접착제-브라켓의 긴밀도는 양호하였다. 6. 적절한 전단접착강도를 가지면서 법랑질 파절과 브라켓 파절을 일으키지 않는 군은 Crystaline-No mix, Crystaline Light Bond, Crystaline-OrthoLC, metal-No mix, metal-Light Bond, metal-OrthoLC군이였다.

  • PDF

강화형 복합레진과 수종의 치과용 합금간의 전단결합강도에 관한 연구 (A Study on the Shear Bond Strength of the Reinforced Composite Resin to Dental Alloys)

  • 김정희;조인호
    • 구강회복응용과학지
    • /
    • 제16권2호
    • /
    • pp.113-122
    • /
    • 2000
  • The reinforced composte resin as the esthetic operative material continuously has been studied because the porcelain fused metal prosthesis is widely used for its excellent esthetics, rigidity and marginal integrity, but it has low fracture resistance against the tensile strength and stress, attrition of the opposite teeth. The reinforced composite resin is well adapt with the dental alloy but it is low the shear bond strength with the dental alloy vs the porcelain fused metal prosthesis, and then has been studied continuously. The purpose of the study was to examine how metal was the higher shear bond strength among the dental alloy was used to the reinforced composite resin and to find the effect that the particle size of sandblasting influenced the shear bond strength. We built up the reinforced composite resin with 4 mm in diameter, 3 mm in height on circular alloy with 5 mm in diameter, 2 mm in height. Type II gold, type IV gold, and Ag-Pd alloy was used as alloys and $50{\mu}m$, $110{\mu}m$, $250{\mu}m$ of the particle size was sandblasted at each alloy in bonding between alloy and resin. We made 90 secimens of 10 per each group and we measured the shear bond strength using the Instron($M100EC^{(R)}$, Mecmesin Co., England). The obtained results were as follows : 1. In comparison among each alloys, Ag-Pd alloy had the highest shear bond strength and the shear bond strength was decreased significantly in the sequence of the type II gold and type IV gold(P<0.001). 2. In comparison according to the size of sandblasting particle, (1) In Ag-Pd alloy, shear bond strength was decreased in the sequence of $110{\mu}m$, $250{\mu}m$, $50{\mu}m$ and there were significant difference in all the group. (P<0.05) (2) In type II gold, it was decreased in the sequence of $250{\mu}m$, $50{\mu}m$, $110{\mu}m$ and there were significant difference. (P<0.05) (3) In type IV gold, it was decreased in the sequence of $110{\mu}m$, $50{\mu}m$, $250{\mu}m$. There were significant difference between the group of $110{\mu}m$ and $50{\mu}m$, the group of $110{\mu}m$ and 250, but there were no significant difference in the group of $50{\mu}m$ and $250{\mu}m$. 3. The highest shear bond strength according to the size of sandblasting particle was $110{\mu}m$ in Ag-Pd alloy and type IV gold, $250{\mu}m$ in type II gold.

  • PDF