• 제목/요약/키워드: bond delamination

검색결과 37건 처리시간 0.022초

플라즈마 용사 열차폐 코팅의 박리수명 평가에 관한 연구 (Evaluation on the Delamination Life of Isothermally Aged Plasma Sprayed Thermal Barrier Coating)

  • 김대진;신인환;구재민;석창성;김문영
    • 대한기계학회논문집A
    • /
    • 제33권2호
    • /
    • pp.162-168
    • /
    • 2009
  • In this study, disk type of thermal barrier coating system for gas turbine blade was isothermally aged in the furnace changing exposure time and temperature. The aging conditions that delamination occurs were determined by the extensive microscopic analyses and bond tests for each aging condition. The delamination map was drawn from the time-temperature matrix form which summarize the delamination conditions. Finally, a method to draw the delamination life diagram of a thermal barrier coating system by using the delamination map was suggested.

플라즈마 용사 열차폐 코팅의 박리수명 평가에 관한 연구 (Evaluation on the Delamination Life of Isothermally Aged Plasma Sprayed Thermal Barrier Coating)

  • 김대진;신인환;구재민;석창성;김문영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.216-221
    • /
    • 2008
  • In this study, disk type of thermal barrier coating system for gas turbine blade was isothermally aged in the furnace changing exposure time and temperature. The aging conditions that determination occurs were determined by the extensive microscopic analyses and bond tests for each aging condition. The delamination map was drawn from the time-temperature matrix form which summarize the delamination conditions. Finally, a method to draw the delamination life diagram of a thermal barrier coating system by using the delamination map was suggested

  • PDF

콘크리트 보강재 박리 검사를 위한 전자파 모델링 (Modeling of Electromagnetic Wave Propagation for Detection of Bond Delamination in Concrete)

  • 남연수;임홍철
    • 한국전산구조공학회논문집
    • /
    • 제17권3호
    • /
    • pp.261-269
    • /
    • 2004
  • 콘크리트 보의 내력 증강을 위해, 탄소 섬유시트와 유리 섬유시트 등의 보강재를 보의 하부에 접착시킴으로써, 기존 콘크리트 부재를 보강할 수 있다. 이러한 보강법에 대한 다양한 설계 방법 및 적용 기법들이 개발되고 있지만, 보강 후 접착 성능을 포함한 건전도 평가는 아직 실용화되지 않은 상태이다. 본 연구에서는 콘크리트 보에 부착된 보강재의 박리 여부를 검사하기 위해 전자기파의 모델링 기법을 적용하였고, 이는 박리검사용 실험 장치를 개발하기 위한 토대를 마련하는데 그 목적이 있다. 이를 위해 3GHz와 5GHz의 가우스 파와 사인 파를 입사파로 사용하여, 박리 두께가 각각 1mm와 3mm 인 콘크리트 시편에 전자파를 보내는 경우를 유한차분 시간영역법(FD-TD method)으로 모델링 하였다. 그 결과, 파형과 중심 주파수에 따라 정확도의 차이는 있었으나 박리의 유무와 위치를 찾아 낼 수 있었다.

Lifetime Performance of EB-PVD Thermal Barrier Coatings with Coating Thickness in Cyclic Thermal Exposure

  • Lu, Zhe;Lee, Seoung Soo;Lee, Je-Hyun;Jung, Yeon-Gil
    • 한국재료학회지
    • /
    • 제25권10호
    • /
    • pp.571-576
    • /
    • 2015
  • The effects of coating thickness on the delamination and fracture behavior of thermal barrier coating (TBC) systems were investigated with cyclic flame thermal fatigue (FTF) and thermal shock (TS) tests. The top and bond coats of the TBCs were prepared by electron beam-physical vapor deposition and low pressure plasma spray methods, respectively, with a thickness ratio of 2:1 in the top and bond coats. The thicknesses of the top coat were 200 and $500{\mu}m$, and those of the bond coat were 100 and $250{\mu}m$. FTF tests were performed until 1140 cycles at a surface temperature of $1100^{\circ}C$ for a dwell time of 5 min. TS tests were also done until more than 50 % delamination or 1140 cycles with a dwell time of 60 min. After the FTF for 1140 cycles, the interface microstructures of each TBC exhibited a sound condition without cracking or delamination. In the TS, the TBCs of 200 and $500{\mu}m$ were fully delaminated (> 50 %) within 171 and 440 cycles, respectively. These results enabled us to control the thickness of TBC systems and to propose an efficient coating in protecting the substrate in cyclic thermal exposure environments.

탄소섬유판으로 보강된 RC부재의 부착길이 변화에 따른 파괴모드 및 휨 보강성능 (Failure Mode and Flexural Performance of RC Beams Strengthened with Different Bond Length of CFRP Strips)

  • 최기선;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.173-176
    • /
    • 2006
  • The one of the commonly reported failure mode of the RC beam strengthened with FRP was caused by the separation of the concrete cover, so called delamination. Therefore, ACI440 recommended that concrete cover delamination can be prevented in strengthened beams if bond length of FRP composite be exteneded over a point of cracking moment. In this study, the failure mode and the flexural performance of RC beam with different bond length of FRP are estimated. Each bonded length is calculated based on the point of cracking moment with addition or subtraction of specific length(=150mm). The results of this study show that mid-span debonding occurs in the specimen strengthened with CFRP strips which are bonded over the point of cracking moment, while concrete cover deliamination occurs at the termination point of CFRP in the specimen with less bonded length than the point of cracking moment region.

  • PDF

탄소섬유판으로 보강된 철근콘크리트 보의 휨거동해석 (Flexural Behavior of Reinforced Concrete Beams Strengthened by CFRP Plates)

  • 양동석;고병순;박선규;유영찬;최기선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.243-246
    • /
    • 2005
  • This paper focuses on the flexural behavior of RC beams externally reinforced using Carbon Fiber Reinforced Plastics plates (CFRP). A non-linear finite element (FE) analysis is proposed in order to complete the experimental analysis of the flexural behaviour of the beams. This paper is a part of a complete program aiming to set up design formulate to predict the strength of CFRP strengthened beams, particularly when premature failure through plates-end shear or concrete cover delamination occurs. An elasto-plastic behaviour is assumed for reinforced concrete and interface elements are used to model the bond and slip.

  • PDF

Regulator IC 고장분석 사례 (Failure Analysis of Regulator IC)

  • 이재혁;하종신;차승규;박상득
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2002년도 정기학술대회
    • /
    • pp.123-129
    • /
    • 2002
  • 본 논문에서는 Regulator IC의 불량원인 규명을 통해 반도체 고장분석 방법 및 개선사례를 소개하고자 한다. 고장분석에 사용된 반도체 Package는 8Pin MSOP(Mini Small Outline Package)로, 시장 불량품을 분석한 결과 Regulator IC의 Stitch Bond에 Heel Crack이 발생하여 불안정한 출력을 발생시킴을 알 수 있었다. Stitch Bond Heel Crack의 원인은 Lead Frame부의 박리(Delamination)에 의해 열이나 진동 등의 외부 Stress가 직접 Stitch Bond에 가해져 Crack이 발생된 것으로, Reflow 재현시험을 통해 확인 할 수 있었다. 박리 발생에 의한 Stitch Bond Heel Crack 방지 대책으로 첫째, Bonding Type을 Stitch Bond 에서 Ball Bond로 변경하여 강도를 개선하고 둘째, PCB Layout 변경을 통해 외력이 직접 Regulator IC에 가해지지 않도록 하였다. 개선 결과 현재까지 시장에서 동일 불량은 발생하지 않았다.

  • PDF

부착길이와 복부정착이 CFRP판으로 보강된 RC 보의 휨 보강효과에 미치는 영향 (Effect of Bond Length and Web Anchorage on Flexural Strength in RC Beams Strengthened with CFRP Plate)

  • 박상렬
    • 콘크리트학회논문집
    • /
    • 제14권5호
    • /
    • pp.645-652
    • /
    • 2002
  • 본 논문은 탄소 FRP 판을 이용한 철근 콘크리트 보의 휨 보강효과와 거동에 대한 연구이다. 본 연구에서의 실험인자로는 휨보강 탄소 FRP 판의 부착길이와 탄소 FRP 쉬트의 복부정착 길이이다. 시험보는 탄소 FRP 판으로 인장면에 부착하여 휨 보강하고 FRP 판을 탄소 FRP 쉬트로 복부에 정착하였다. 일반적으로 복부정착이 없는 휨 보강된 보들의 파괴형태는 횡방향 주철 근을 따라 발생한 콘크리트 덮개 박리파괴를 나타내었다. 반면, 탄소 FRP 쉬트로 복부 정착된 휨 보강 보들은 CFRP 파단파괴 후 콘크리트 경계면 전단 박리파괴를 나타내었다. 보강된 보들의 극한하중과 극한처짐은 FRP 판의 휨 부착길이의 증가에 따라 증가하였다. 또한, 휨 보강된 보들은 FRP 쉬트의 복부정착 길이의 증가에 따라 극한하중과 극한처짐 값이 증가하였다. 특히, 복부 정착한 보들은 최대 극한하중에 도달한 후에도 상당한 극한하중 지지능력을 상당한 극한 처짐 시까지 유지하였다. 시험보의 길이에 걸친 FRP 판의 변형률 분포는 휨 모멘트도의 모양과 거의 유사하여 전단지간에서 일정한 전단응력 분포를 가정할 수 있었다. 전지간을 휨 보강한 보에 있어서는 콘크리트와 FRP 쉬트에 의한 경계면에서의 극한전단 저항강도는 복부정착 길이가 늘어남에 따라 증가하였다. 전단 저항강도 중에서 본 실험에서 사용한 복부 정착 FRP 쉬트도 일부의 전단 저항강도를 부담하였다.

경사화 두께를 갖는 열차폐 코팅의 열적 내구성 평가 (Evaluation of Thermal Durability for Thermal Barrier Coatings with Gradient Coating Thickness)

  • 이승수;김준성;정연길
    • 한국산학기술학회논문지
    • /
    • 제21권8호
    • /
    • pp.248-255
    • /
    • 2020
  • 경사화 두께를 갖는 열차폐 코팅의 열적 내구성과 열적 안정성에 대한 코팅층 두께의 영향을 화염 열피로 시험과 열충격 시험을 통해서 조사하였다. Bond 층과 top 층은 각각 Ni-Cr계 상용 MCrAlY 분말과 상용 이트리아 안정화 지르코니아 (YSZ) 분말을 사용하여 니켈기지의 초내열합금 모재 (GTD-111)에 대기 플라즈마 용사법 (APS)으로 코팅층을 형성하였다. 1100 ℃의 화염으로 1429회 열피로 시험 후 bond 층이 일부 산화되고 top 층과 bond 층 계면에서 열화에 의한 산화층 (TGO)이 관찰되었으나, 코팅층 부위와 관계없이 균열이나 박리현상 없는 양호한 미세구조를 나타내었다. 1100 ℃ 열충격 시험결과, 37회 열충격 테스트 후 코팅층의 얇은 부위에서 박리가 시작되어 98회 시험 후 코팅층의 50% 이상이 박리되었으며, 코팅층의 두께가 얇게 형성된 부위는 코팅층이 두껍게 형성된 부위에 비해, top 층의 박리와 함께 bond 층의 산화가 많이 진행되었으며, 코팅층 두께가 상대적으로 두껍게 형성된 부위에서 열차폐 효과의 증가로 인해 bond 층의 내산화성과 열적 안정성이 우수한 것으로 나타났다.