• 제목/요약/키워드: bond agent

검색결과 328건 처리시간 0.029초

포스트 접착 시멘트의 종류와 적용 방법에 따른 접착 효율 비교 (Comparison of the post cementation efficacy using different cements and methods)

  • 조옥인;이상진;박정길;허복;김현철
    • 대한치과의사협회지
    • /
    • 제48권9호
    • /
    • pp.680-687
    • /
    • 2010
  • The purpose of this study was to compare post cementation efficacy according to the different adhesive systems and cement delivery methods. A total of 40 extracted human single-rooted premolar teeth were randomly divided in four groups according to the two luting agents of Unicem applicap (3M ESPE, St. Paul, MN, USA) or Variolink II (Ivoclar Vivadent, Liechtenstein) and cement delivery methods of direct cement application or lentulo spiral application. After restoration using glass?fiber posts, the samples were embedded in acrylic resin. Three sections of 2 mm thickness were prepared from each specimen, and the post in each section was subjected to a push-out test. The data were analysed statistically at significant level of 95%. The Unicem had significantly higher push-out bond strength than Variolink and the lentulo spiral application made higher bond strength (p<0.05). Adhesive failure between cement and dentin was predominant in all groups. The Unicem of self-etch system and cement delivery using lentulo spiral showed clinically acceptable and comparable bonding strength for the fiber post.

Bonding agent의 치수 섬유아세포에 대한 독성 연구 (THE CYTOTOXIC EFFECTS OF BONDING AGENTS ON THE HUMAN PULP FIBROBLASTS)

  • 박선희;민병순;최호영;박상진;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제16권2호
    • /
    • pp.99-117
    • /
    • 1991
  • The purpose of this study is to evaluate the effects of dentin bonding agents on the fibroblasts cultivated from human pulp tissue. The fibroblasts were cultured in DMEM/10%FBS medium. Whatman filter paper discs (6mm diameter) soaked with $2{\mu}l$ of dentin bonding agents were placed on a millipore filter (pore size $0.22{\mu}m$) contained in a 50mm Petri dish, and then, exposed for 10 minutes, 30 minutes, 1 hour, 6 hours, 12 hours, 24 hours, 4 days and 7 days in $37.^{\circ}C$, 5% $CO_2$ incubator. The results of the experiments were analyzed by counting the cells and measuring the protein contents at 1 day, 4 days and 7 days. The results of this study were as follows: l. CLEARFIL NEW BOND, LITE-FIL BOND, GLUMA 3 Primer and GLUMA 4 Sealer showed cytotoxicity compared to the control group in the cell counts and the protein contents. 2. GLUMA 4 Sealer showed the least cytotoxicity among the three dentin bonding agents. 3. The results of the cell count were simialr to the results of protein content measurement. 4. LITE-FIL BOND exhibited marked cytotoxicity during 1 day, but, the cytotoxicity was slightly reduced after 4 and 7 days. 5. In GLUMA 3 Primer group, it was not possible to count the cell numbers and measure the protein contents, but the degeneration of cells was observed under the inverted phase-contrast microscope.

  • PDF

Efficacy of various cleaning solutions on saliva-contaminated zirconia for improved resin bonding

  • Kim, Da-Hye;Son, Jun-Sik;Jeong, Seong-Hwa;Kim, Young-Kyung;Kim, Kyo-Han;Kwon, Tae-Yub
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.85-92
    • /
    • 2015
  • PURPOSE. This study aimed to investigate the efficacy of cleaning solutions on saliva-contaminated zirconia in comparison to air-abrasion in terms of resin bonding. MATERIALS AND METHODS. For saliva-contaminated air-abraded zirconia, seven cleaning methods)-no contamination (NC), water-spray rinsing (WS), additional air-abrasion (AA), and cleaning with four solutions (Ivoclean [IC]; 1.0 wt% sodium dodecyl sulfate [SDS], 1.0 wt% hydrogen peroxide [HP], and 1.0 wt% sodium hypochlorite [SHC])-were tested. The zirconia surfaces for each group were characterized using various analytical techniques. Three bonded resin (Panavia F 2.0) cylinders (bonding area: $4.5mm^2$) were made on one zirconia disk specimen using the Ultradent jig method [four disks (12 cylinders)/group; a total of 28 disks]. After 5,000 thermocycling, all specimens were subjected to a shear bond strength test with a crosshead speed of 1.0 mm/minute. The fractured surfaces were observed using an optical and scanning electron microscope (SEM). RESULTS. Contact angle measurements showed that groups NC, AA, IC, and SHC had hydrophilic surfaces. The X-ray photoelectron spectroscopy (XPS) analysis showed similar elemental distributions between group AA and groups IC and SHC. Groups IC and SHC showed statistically similar bond strengths to groups NC and AA (P>.05), but not groups SDS and HP (P<.05). For groups WS, SDS, and HP, blister-like bubble formations were observed on the surfaces under SEM. CONCLUSION. Within the limitations of this in vitro study, some of the cleaning solutions (IC or SHC) were effective in removing saliva contamination and enhancing the resin bond strength.

Influence of modeling agents on the surface properties of an esthetic nano-hybrid composite

  • Kutuk, Zeynep Bilge;Erden, Ecem;Aksahin, Damla Lara;Durak, Zeynep Elif;Dulda, Alp Can
    • Restorative Dentistry and Endodontics
    • /
    • 제45권2호
    • /
    • pp.13.1-13.10
    • /
    • 2020
  • Objective: The aim of this study was to evaluate the influence of different modeling agents on the surface microhardness (Vickers hardness number; VHN), roughness (Ra), and color change (ΔE) of a nano-hybrid composite with or without exposure to discoloration by coffee. Materials and Methods: Sixty-four cylinder-shaped nano-hybrid composite specimens were prepared using a Teflon mold. The specimens' surfaces were prepared according to the following groups: group 1, no modeling agent; group 2, Modeling Liquid; group 3, a universal adhesive (G-Premio Bond); and group 4, the first step of a 2-step self-adhesive system (OptiBond XTR). Specimens were randomly allocated into 2 groups (n = 8) according to the storage medium (distilled water or coffee). VHN, Ra, and ΔE were measured at 24 hours, 1 week, and 6 weeks. The Kruskal-Wallis test followed by the Bonferroni correction for pairwise comparisons was used for statistical analysis (α = 0.05). Results: Storage time did not influence the VHN of the nano-hybrid composite in any group (p > 0.05). OptiBond XTR Primer application affected the VHN negatively in all investigated storage medium and time conditions (p < 0.05). Modeling Liquid application yielded improved Ra values for the specimens stored in coffee at each time point (p < 0.05). Modeling Liquid application was associated with the lowest ΔE values in all investigated storage medium and time conditions (p < 0.05). Conclusion: Different types of modeling agents could affect the surface properties and discoloration of nano-hybrid composites.

치질에 대한 상아질 접착제의 접합도에 관한 연구 (A STUDY ON THE ADAPTATION OF DENTIN BONDING AGENTS TO TOOTH STRUCTURE)

  • 박성택;조영곤;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.732-743
    • /
    • 1995
  • The purpose of this study was to evaluate the adaptation of light cured dentin bonding agents to tooth structure by measuring contraction gaps on interfaces between cavity wall and composite resin under SEM study. In this study, class V cavities with cementum margin were prepared on the buccal surfaces of 15 extracted human premolar teeth and teeth were randomly assigned 3 groups of 5 teeth each. The cavities were filled with three dentin bonding agents and two composite resins were investigated for this study: three dentin bonding agents; Scotchbond 2, Scotchbond Multi-Purpose. All-Bond 2, two composite resins; Silux Pius, Z-100. Group 1 : Scotchbond 2 + Silux Plus Group 2 : Scotchbond Multi~Purpose + Z-100 Group 3 : All-Bond 2 + Z-100 The restored teeth were stored in 100% relative humidity at $37^{\circ}C$ for 7 days. And then, the roots of the teeth were removed with the tapered fissure bur and the remaining crowns were sectioned occlusogingivally through the center of restorations. Adaptation at tooth-restoration interface was assesed occlusally, gingivally, and axially by scanning electron microscope. The results were as follows : 1. In Group 1, the adaptation to dentinal wall of Scotchbond 2 was poor, but the adaptation to enamel wall of Scotchbond 2 was excellent. 2. In Group 2, the adaptation to occlusal was axial wall and gingival wall of Scotchbond Multi-Purpose was excellent. Especially in axially wall, the dentin bonding agents infiltrated into dentinal tubules and there was excellent adaptation to dentinal wall. 3. In Group 3, the adaptation to occlusal wall and axial wall of All-Bond 2 was excellent. But in gingival wall, there was gap formation between composite resin and dentin bonding agent.

  • PDF

Adhesive systems applied to dentin substrate under electric current: systematic review

  • Carolina Menezes Maciel;Tatiane Cristina Vieira Souto;Barbara de Almeida Pinto;Lais Regiane Silva-Concilio;Kusai Baroudi;Rafael Pino Vitti
    • Restorative Dentistry and Endodontics
    • /
    • 제46권4호
    • /
    • pp.55.1-55.9
    • /
    • 2021
  • Objectives: The purpose of this systematic review was to collect and discuss the technique of adhesive systems application on dentin substrate under electric current. Materials and Methods: The first search strategy was based on data available at PubMed, LILACS, Scielo, Scopus, and Cochrane Library, using a combination of descriptors such as "dentin bond agents OR adhesive system AND electric current OR electrobond" or "dentin bonding agents OR dentin bonding agent application OR adhesive system AND electric current OR electrobond", with no limit regarding the publication year. The second search strategy was based on the articles' references found previously. An additional search strategy was applied that concerned the proposed theme in the SBU-UNICAMP (Unicamp's Library System Institutional Repository). Results: Twelve studies published between 2006 and 2020 were found. The analyses of the selected studies showed that the use of electric current during adhesive systems application on dentin, whether conventional or self-conditioning, increases resinous monomer infiltration in the dentin substrate, which improves the hybridization processes and the bond strength of the restorative material to dentin. Conclusions: Despite the favorable results related to the use of this technique, there is still no specific protocol for the application of adhesive systems under electric current.

Y-TZP ceramic의 표면처리에 따른 전장용 레진의 전단결합강도 (Effect of Conditioning Methods on the Shear Bond Strength of Veneering composite on Zirconia Ceramic)

  • 남현석;송광엽;안승근;박주미
    • 구강회복응용과학지
    • /
    • 제26권3호
    • /
    • pp.253-264
    • /
    • 2010
  • 최근 개발된 Yttrium-stabilized-tetragonal-zirconia-polycrystal(Y-TZP ceramic)은 생체 친화적이며 높은 굴곡 강도, 파절 저항성, 파괴 인성을 지니고 CAD-CAM을 통해 milling이 가능하여 많은 치과 영역에서 사용되고 있다. 구치부 zirconia framework을 사용하는 고정성 수복물의 경우에는 상부 장석 도재의 상대적으로 높은 빈도의 파절을 보이고 있다. 복합레진은 취성이 적고 법랑질 보다 마모도가 낮으며 수리가 용이하다. 높은 교합압 부위에서 전장용 복합레진을 사용한 임플란트 수복은 기능적인 장점을 지니며 흥미롭게 여겨지고 있다. 이번 연구의 목적은 Y-TZP ceramic에 몇 가지 표면 처리를 시행하여 전장용 복합레진을 적용 시켰을 때 도재 전장시과 비교하여 임상적 활용을 위한 유용한 전단결합강도를 지니는지를 알고자 함이다.

Tricalcum-silicate 기반 치수복조제의 미세누출 및 상아질 전단결합강도 비교 (Comparison of the Microleakage and Shear Bond Strength to Dentine of Different Tricalcium Silicate-based Pulp Capping Materials)

  • 김미리;조완선;지명관;이상호;이난영
    • 대한소아치과학회지
    • /
    • 제46권1호
    • /
    • pp.76-84
    • /
    • 2019
  • 이 연구의 목적은 3종의 수복재료와 3종의 tricalcium-silicate 기반 치수복조제의 미세누출을 평가하고, 이들 치수복조제와 상아질 사이의 전단결합강도를 비교하는 것이다. 수복재료로는 복합레진(CR), 레진강화형 글래스아이오노머 시멘트(RMGI), 그리고 전통적인 글래스아이오노머 시멘트(GIC)를, 치수복조제로는 TheraCal $LC^{(R)}$(TLC), $Biodentine^{(R)}$ (BD), 그리고 $ProRoot^{(R)}$ white MTA (WMTA)을 사용했다. 소의 절치에 5급와동을 형성하여 이를 적용하는 치수복조제와 수복재료에 따라 9개의 그룹으로 분류하고 0.5% fuchsin 용액을 이용한 염색침투법을 시행했다. 각 표본을 절단하고 입체현미경으로 관찰해 미세누출 정도를 평가했다. 아크릴 레진에 소 절치의 임상적 치관을 매몰한 후 수평으로 절단해 준비한 표본을 임의로 3그룹으로 나누었다. 표본의 상아질에 그룹별로 TLC, BD, 그리고 WMTA 블록을 적용한 후 universal testing machine을 이용해 전단결합강도를 측정했다. 미세누출은 TLC + GIC, TLC + RMGI, TLC + CR, 그리고 BD + GIC 그룹에서 가장 적었고, WMTA + RMGI와 WMTA + CR 그룹에서 가장 많았다. 전단결합강도는 WMTA 그룹에서 다른 그룹보다 통계적으로 유의하게 낮은 것으로 나타났다.

시효처리가 복합레진 수복물의 미세누출에 미치는 영향에 관한 연구 (The Effect of Aging Treatment for Microleakage within Composite Resin Restoration)

  • 유승훈
    • 대한소아치과학회지
    • /
    • 제40권4호
    • /
    • pp.283-295
    • /
    • 2013
  • 본 연구는 시효처리가 세 가지 상아질 접착제의 미세누출에 미치는 영향을 MicroCT를 이용하여 조사하였다. 5세대 상아질 접착제인 Adper$^{TM}$ Single bond Plus(3M-ESPE, USA)와 6세대 상아질 접착제인 AdheSE$^{(R)}$(Ivoclar Vivadent, Lichtenstein)와 Adper$^{TM}$ Prompt$^{TM}$ L-Pop$^{TM}$(3M-ESPE, USA)을 이용하였다. 세 가지 상아질 접착제를 이용하여 3MESPE 사의 Filtek$^{TM}$ Z250을 V급 와동에 수복하고 24시간 생리식염수에 보관한 군(I군), 열 순환을 시행한 군(II군), 인공 칫솔질 법을 적용한 군(III군), 인공 타액에 6개월간 보관한 군(IV군)으로 분류하였다. Adper$^{TM}$ Single bond Plus를 이용한 시편은 II군과 III군에서 미세누출의 양이 늘어났으며 IV군에서 감소하였다. I군에 비해 II군이 많은 미세누출을 보였으며(p < 0.05), II군과 III군에 비하여 IV에서 적은 미세누출을 보였다(p < 0.05). AdheSE$^{(R)}$를 이용한 시편은 차이를 보이지 않았다(p > 0.05). Adper$^{TM}$ Prompt$^{TM}$ L-Pop$^{TM}$을 이용한 시편은 차이를 보이지 않았다(p > 0.05). I군에서는 AdheSE$^{(R)}$가 Adper$^{TM}$ Single bond Plus와 Adper$^{TM}$ Prompt$^{TM}$ L-Pop$^{TM}$에 비해 미세누출이 많다(p < 0.05). II군에서는 상아질 접착제간 차이가 없었다(p > 0.05). III군에서는 AdheSE$^{(R)}$가 Adper$^{TM}$ Single bond Plus와 Adper$^{TM}$ Prompt$^{TM}$ L-Pop$^{TM}$에 비해 미세누출이 많았다(p < 0.05). IV군에서는 Adper$^{TM}$ Single bond Plus에 비해 AdheSE$^{(R)}$와 Adper$^{TM}$ Prompt$^{TM}$ L-Pop$^{TM}$의 미세누출이 많았다(p < 0.05).

컴포머 충전과정에 따른 상아질 투과도의 변화 (DENTIN PERMEABILITY CHANCE ACCORDING TO THE PROCESS OF COMPOMER RESTORATION)

  • 조혜진;이경하;이세준;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.382-388
    • /
    • 2002
  • Compomer is composed of matrix and filler : matrix is made of the combination of resins and polycarboxylic molecules that are light-cured, and a filler is a glass component which is capable of ion-release. The resin content of compomers produces polymerization shrinkage which can adversely affect marginal adaptation. Pretreatment is a fundamental step which is treated with conditioner or primer in the use of these materials. Microleakage of restorative materials has been investigated mostly by dye penetration method. Dye penetration method was not quantitative and not measured repeatedly. Fluid filtration method, introduced and developed by Pashley's group, has been extensively used for 20 years for research purpose to understand the physiology of dentin, as well as the effects of various restorative treatments on dentin permeability. It permits quantitative, nondestructive measurment of microleakage in a longitudinal manner. The purpose of this study was to evaluate the change of dentin permeability according to the process of compomer restoration. In this study. Cl V cavities were prepared on buccal surface of thirty extracted human molars. The prepared cavities were etched by 37% phosphoric acid. The experimental teeth were randomly divided into three groups. Each group was treated with following materials Group 1 : Prime & Bond NT/Dyract AP, Group2: Single Bond/F2000 compomer, Group 3 : Syntac Single Component/Compoglass. The bonding agent and compomer were applied for each group following manufacturers information. Dentin permeability of each group was measured at each process by fluid filtration method; Step 1 : preparation(smear layer). Step 2 : etching(smear layer removal), Step 3 : applying the bonding agent, Step 4 : filling the compomer. Dentin permeability was expressed by hydraulic conductance ($\mu\textrm{l}$ min$^{-1}$cm$H_2O$$^{-1}$). The data were analysed statistically using One-way ANOVA and Sheffe's method. The results were as follows : 1. Dentin permeability differences between each process were significant except between step 1 and step 2(p<0.01). 2. Dentin permeability after removal of smear layer was highly increased(p<0.01). 3. In most case, decrease of dentin permeability was obtained by applying bonding agent(p<0.01). 4. Dentin permeability differences among the experimental groups were not significant(p>0.05). 5. None of compomers used in this study showed perfect seal at the interface.