• 제목/요약/키워드: bolted connections

검색결과 144건 처리시간 0.026초

Experimental study on a new type of assembly bolted end-plate connection

  • Li, Shufeng;Li, Qingning;Jiang, Haotian;Zhang, Hao;Yan, Lei;Jiang, Weishan
    • Steel and Composite Structures
    • /
    • 제26권4호
    • /
    • pp.463-471
    • /
    • 2018
  • The bolted end-plate beam-column connections have been widely used in steel structure and composite structure because of its excellent seismic performance. In this paper, the end-plate bolted connection is applied in the concrete structure, A new-type of fabricated beam-column connections with end-plates is presented, and steel plate hoop is used to replace stirrups in the node core area. To study the seismic behavior of the joint, seven specimens are tested by pseudo-static test. The experimental results show that the new type of assembly node has good ductility and energy dissipation capacity. Besides, under the restraint effect of the high-strength stirrup, the width of the web crack is effectively controlled. In addition, based on the analysis of the factors affecting the shear capacity of the node core area, the formula of shear capacity of the core area of the node is proposed, and the theoretical values of the formula are consistent with the experimental value.

Analysis of the Behavior of Bolt Jointed Wood Connections by Applying Semi-Rigid Theory

  • Kim, Gwang-Chul;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제28권4호
    • /
    • pp.72-82
    • /
    • 2000
  • Attempts were made to analyze the behavior of single and multiple-bolted connections through theoretical methods such as European yield theory, empirical approaching method, and semi-rigid theory instead of many experimental methods that have been actually inefficient and non-economical. In the case of a single-bolted connection, if accurate characteristic values of a material could be guaranteed, it would be more convenient and economical to perform the behavior analysis using a model based on the semi-rigid theory, instead of the existing complex yield model, or the empirical formula which produces errors, giving different results from the actual ones. If the variables of equation determining the load and deformation could be appropriately controlled, the analytical method in conjunction with a semi-rigid theory could be effectively applied to obtain the desirably predicted value, considering that the appropriate solution could be derived through a simpler equation using a less difficult method compared to the existing yield model. It is concluded that analytical method with semi-rigid theory can be used in the behavior analysis of bolted connection because our developed method showed excellent analysis ability of behavior until number of bolt is two. Although our analytical method has the disadvantage that the number of bolt is limited to two, it is concluded that it has the advantage than numerical method which complicated and time-consuming.

  • PDF

SHN490강종의 보-기둥 접합부 형태에 따른 실험적 연구 (Test Results on the Type of Beam-to-Column Connection using SHN490 Steel)

  • 김소영;변상민;이호;신경재
    • 한국강구조학회 논문집
    • /
    • 제27권3호
    • /
    • pp.311-321
    • /
    • 2015
  • 본 연구는 중 저층 건축물에 적용된 강재의 보-기둥 접합부에 따른 내진성능을 규명하기 위한 실험적 연구이다. 실험체는 보-기둥 접합부의 보 플랜지와 웨브의 접합형태에 따라 분류하여 총 5가지를 제작하였다. 실험체는 웨브와 플랜지 모두 용접한 접합부(SHN-W-W)와 웨브는 용접하고 플랜지는 고력볼트 접합한 접합부(SHN-W-B)와 웨브는 고력볼트 접합하고 플랜지는 용접접합한 접합부(SHN-B-W)와 웨브와 플랜지 모두 고력볼트 접합한 접합부(SHN-B-B)와 보 단부에 엔드플레이트를 이용하여 접합한 접합부(SHN-EP)이다. 실험은 KBC2009에서 제시하는 반복재하인증실험으로 층간변위각(${\theta}$)을 제어하기 위한 변위 제어방식으로 실시하였다. 실험으로부터 각 시험체의 하중-회전각 곡선을 나타내었으며, 접합부의 최종 파괴형상을 요약하였다. 접합부는 강성과 강도의 관점에서 강접합과 반강접합으로 분류하였으며 내진성능평가를 위한 에너지소산능력을 비교하였다.

Behaviour of bolted connections in concrete-filled steel tubular beam-column joints

  • Beena, Kumari;Naveen, Kwatra;Shruti, Sharma
    • Steel and Composite Structures
    • /
    • 제25권4호
    • /
    • pp.443-456
    • /
    • 2017
  • Many authors have established the usefulness of concrete filled steel tubular (CFST) sections as compression members while few have proved their utility as flexural members. To explore their prospective as part of CFST frame structures, two types of connections using extended end plate and seat angle are proposed for exterior joints of CFST beams and CFST columns. To investigate the performance and failure modes of the proposed bolted connections subjected to static loads, an experimental program has been executed involving ten specimens of exterior beam-to-column joints subjected to monotonically increasing load applied at the tip of beam, the performance is appraised in terms of load deformation behaviour of joints. The test parameters varied are the beam section type, type and diameter of bolts. To validate the experimental behaviour of the proposed connections in CFST beam-column joints, finite element analysis for the applied load has been performed using software ATENA-3D and the results of the proposed models are compared with experimental results. The experimental results obtained agree that the proposed CFST beam-column connections perform in a semi-rigid and partial strength mode as per specification of EC3.

Experimental study on two types of new beam-to-column connections

  • Ma, Hongwei;Jiang, Weishan;Cho, Chongdu
    • Steel and Composite Structures
    • /
    • 제11권4호
    • /
    • pp.291-305
    • /
    • 2011
  • The new structure consisting of continuous compound spiral hoop reinforced concrete (CCSHRC)column and steel concrete composite (SCC) beam has both the advantages of steel structures and concrete structures. Two types of beam-to-column connections applied in this structural system are presented in this paper. The connection details are as follows: the main bars in beam concrete pass through the core zone for both types of connections. For connecting bar connection, the steel I-beam webs are connected by bolts to a steel plate passing through the joint while the top and bottom flanges of the beams are connected by four straight and two X-shaped bars. For bolted end-plate connection, the steel I-beam webs are connected by stiffened extended end-plates and eight long shank bolts passing through the core zone. In order to study the seismic behaviour and failure mechanisms of the connections, quasi-static tests were conducted on both types of full-scale connection subassemblies and core zone specimens. The load-drift hysteresis loops show a plateau for the connecting bar connection while they are excellent plump for bolted end-plate connection. The shear capacity formulas of both types of connections are presented and the values calculated by the formula agree well with the test results.

2개의 볼트를 갖는 고강도 알루미늄 합금 일면전단 볼트접합부의 내력 (Strength of High Strength Aluminum Alloys Single Shear Bolted Connections with Two Bolts)

  • 강현식;김태수
    • 한국강구조학회 논문집
    • /
    • 제30권2호
    • /
    • pp.87-96
    • /
    • 2018
  • 본 연구는 유한요소해석을 적용하여 고강도 알루미늄 합금(7075-T6)의 2개 볼트로 구성된 일면전단 볼트접합부의 구조거동과 면외변형에 의한 최대내력에 미치는 영향을 조사하는 것을 연구목적으로 한다. 볼트접합부의 구조거동을 예측하는데 있어 기존실험결과와 해석결과의 비교를 통해 유한요소해석의 타당성을 검증하였다. 면외변형 발생으로 볼트접합부의 내력저하정도를 정량적으로 평가하였다. 연단거리에 대한 추가적인 변수해석이 수행되었고 하중방향연단거리와 하중직각방향연단거리에 따른 면외변형 발생조건을 제시하였다. 최종적으로 알루미늄 합금 7075-T6 볼트접합부에 대한 면외변형의 영향을 고려한 수정내력식을 제안하였다.

Structural performance evaluation of bolted end-plate connections in a half-through railway inclined girder

  • Jung Hyun Kim;Chang Su Shim
    • Steel and Composite Structures
    • /
    • 제49권5호
    • /
    • pp.473-486
    • /
    • 2023
  • A through-railway bridge with an inclined girder has recently been applied to optimize the cross-section of a slender bridge structure in railway bridges. To achieve the additional cross-section optimization effect by the bolted end-plate connection, it is necessary to investigate the application of the bolted end-plate tension connection between the inclined girder and the crossbeam. This basic study was conducted on the application of the bolted end-plate moment connection of crossbeams to half-through girders with inclined webs. The combined behavior of vertical deflection and rotational behavior was observed due to the effect of the web inclination in the inclined girder where the steel crossbeam was connected to the girder by the bolted end-plate moment connection. Therefore, in the experiment, the deflection of the inclined girder was 1.77-2.93 times greater than that of the vertical girder but the lateral deflection of the inclined girder was 0.4 times less than that of the vertical girder. Moreover, the tensile stress of the upper bolts in the inclined girder with low crossbeams was clearly 0.81 times lower than that of the vertical girder. According to the results, the design formula for vertical girders does not reflect the influence of the web inclination. Therefore, this study proposed the design procedures for the inclined girder to apply the bolted end-plate moment connection of the crossbeam to the inclined girder by reflecting the design change factors according to the effect of the web inclination.

Reliabilities of distances describing bolt placement for high strength steel connections

  • Oztekin, Ertekin
    • Structural Engineering and Mechanics
    • /
    • 제54권1호
    • /
    • pp.149-168
    • /
    • 2015
  • In the bolted connections, bolt placements are generally described and are generally made in the direction of design effects and in the perpendicular direction to design effects. In these both directions, the reliability of the distance of bolts to the edges of connection plate and the distance of bolts to each other is investigated for high strength steel connections built up with high strength bolts in this study. For this purpose, simple SL (bearing type shear connection) and SLP (bearing type shear connection for body-fit bolts) type steel connections with St 52 grade steel plates with 8 different thicknesses and with 8.8D grade high strength bolts (HV) were constituted and analyzed under H (Dead Loads+Live Loads+Snow Loads+Roof Loads) and HZ (H Loads+Wind Loads+Earthquake Loads) loadings. Geometric properties, material properties and design actions were taken as random variables. Monte Carlo Simulation method was used to compute failure risk and the first order second moment method was used to determine the reliability indexes of those different distances describing the placement of bolts. Results obtained from computations have been presented in graphics and in a Table. Then, they were compared with some values proposed by some structural codes. Finally, new equations were constituted for minimum and maximum values of distances describing bolt placement by regression analyses performed on those results.

Slip-resistant bolted connections under freeze-thaw cycles and low temperature

  • A. Fuente-Garcia;M.A. Serrano-Lopez;C. Lopez-Colina;F., Lopez-Gayarre
    • Steel and Composite Structures
    • /
    • 제48권3호
    • /
    • pp.251-262
    • /
    • 2023
  • There are many examples of steel structures subjected to severe environmental conditions with bolted connections directly exposed to extreme climatic agents such as freeze-thaw cycles or low temperatures. Some examples are: steel bridges, mining transfer towers, wind towers... These service conditions neither are included in Eurocode 3 or EN1090-2, nor there are references in other international standards. In this experimental research, 46 specimens of non-slip joints with HV M20 bolts and four different types of contact surfaces have been studied. Half of the specimens were subjected to fourteen twelve-hours freeze-thaw cycles, with periodic immersion in water and temperature oscillation. Subsequently, half of the connections were subjected to a slip test under monotonic load at temperature of -20 ± 0.5 ℃ and the other half at room temperature. The results were compared with others equal joints not subjected to freeze-thaw cycles and kept at room temperature for the same time. This finally resulted in 4 sets of joints by combining the freeze-thaw degradation or not with the low-temperature conditions or not in the slip testing. Therefore, a total of 16 different conditions were studied by also considering 4 different contact surfaces between the joined plates in each set. The results obtained show influence of environmental conditions on the slip resistant capacity of these joints.

Investigation of the effect of bolt diameter and end plate thickness change on bolt column-beam connection

  • Samet Oguzhan Dogan;Senol Gursoy;Ramazan Ozmen
    • Structural Engineering and Mechanics
    • /
    • 제89권2호
    • /
    • pp.155-170
    • /
    • 2024
  • Several types of column-beam connections are used in the design of steel structures. This situation causes different cross-section effects and, therefore, different displacements and deformations. In other words, connection elements such as welds, bolts, continuity plates, end plates, and stiffness plates used in steel column-beam connections directly affect the section effects. This matter reveals the necessity of knowing the steel column-beam connection behaviours. In this article, behaviours of bolted column-beam connection with end plate widely used in steel structures are investigated comparatively the effects of the stiffness plates added to the beam body, the change in the end plate thickness and bolt diameter. The results obtained reveal that the moment and force carrying capacity of the said connection increases with the increase in the end plate thickness and bolt diameter. In contrast, it causes the other elements to deform and lose their capacity. This matter shows that optimum dimensions are very important in steel column-beam connections. In addition, it has been seen that adding a stiffness plate to the beam body part positively contributes to the connection's moment-carrying capacity.