• Title/Summary/Keyword: bolted connections

Search Result 144, Processing Time 0.033 seconds

Evaluation of Three Support Shapes on Behavior of New Bolted Connection BBCC in Modularized Prefabricated Steel Structures

  • Naserabad, Alifazl Azizi;Ghasemi, Mohammad Reza;Shabakhty, Naser;Arab, Hammed Ghohani
    • International journal of steel structures
    • /
    • v.18 no.5
    • /
    • pp.1639-1653
    • /
    • 2018
  • Bolted connections are suitable due to high quality prefabrication in the factory and erection in the workplace. Prefabrication and modularization cause high speed of erection and fabrication, high quality and quick return of investment. Their technical hitches transportation can be removed by prefabrication of joints and small fabrication of components. Box-columns are suitable members for bolted structures such as welded steel structures with moment frames in two directions etc., but their continual fabrication in multi-story buildings and performing the internal continuity plate in them will cause some practical dilemmas. The details of the proposal technique introduced here, is to remove such problems from the box columns. Besides, some other advantages include new prefabricated bolted beam-to-column connections referred to BBCC. This connection is a set of plates joined to columns, beams, support, and bolts. For a better understanding of its fabrication and erection techniques, two connection and one structural maquettes are made. The present work aims to study the cyclic behavior of connection numerically. To verify the accuracy of model, a similar tested connection was modelled. Its verification was then made through comparison with test results. The behavior of connection was evaluated for an exterior connection using three different support shapes. The effects of support shapes on rigidity, ductility, rotation capacity, maximum strength, four rad rotation strength were compared to those of the AISC seismic provision requirements. It was found that single beams support has all the AISC seismic provision requirements for special moment frames with and without a continuity plate, and box with continuity plate is the best support in the BBCC connection.

Shear Performance of Glass Fiber Reinforced Glulam Bolted Connection

  • Kim, Keon-ho;Hong, Soon-il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.661-671
    • /
    • 2015
  • To evaluate the shear performance of the textile glass fiber and the sheet glass fiber reinforced glulam bolted connections, a tension type shear test was conducted. The average yield shear strength of the bolted connection of reinforced glulam was increased by 12% ~ 31% compared to the non-reinforced glulam. It was confirmed that the shear performance of 5D end distance of the glass fiber reinforced glulam connection corresponds to that of 7D of the non-reinforced glulam connection proposed in building design requirements in various countries. Compared to the non-reinforced glulam, the average shear strength of textile glass fiber reinforced glulam was markedly increased. The non-reinforced glulam and the GFRP reinforced glulam underwent a momentary splitting fracture. However, the failure mode of textile glass fiber reinforced glulam showed a good ductility.

Strength Property of Double Shear Bolted-Connections of Larch (낙엽송 부재의 이중 전단 볼트 접합부 강도 성능)

  • Park, Chun-Young;Kim, Kwang-Mo;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.1 s.129
    • /
    • pp.7-16
    • /
    • 2005
  • This study was carried out to evaluate the structural property of double shear bolted connections in Korean Larch. For the main member, sawn lumber and Glulam were used in which thickness of lumber is 39 mm, 89 mm, 139 mm, 189 mm and Glulam 80 mm, 140 mm, 170 mm. For the side member, sawn lumber and steel plate were used in which thickness of lumber is the same of the main member and steel plate is 6mm. And connections were jointed by M12, M16, M20 bolts which were usually used for wood constructions in Korea. Directions of loading to connections were perpendicular and parallel to grain of main and side member. First, through the dowel bearing test, the dowel bearing strength was evaluated and through the bolt bending tests, the bolt bending strength was evaluated. And then experiments for the connection were performed. Obtained results from experiments were compared with calculated values by EYM and analyzed. Strength of double shear bolted connections in Korean Larch was similar or higher than calculated value by EYM. Especially when the side member was made by the sawn lumber, it was similar to the calculated value. In failure mode, the mode was effected by the knot and the dry defect. In the thin main member, it was shown mode I and as the thickness of the main member was thicker, it was changed into mode III.

Development of the Floating Type Photovoltaic Energy Generation System (부유식 태양광 에너지 발전시설의 개발)

  • Choi, Hoon;Joo, Hyung-Joong;Nam, Jeong-Hun;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.1 no.1
    • /
    • pp.16-26
    • /
    • 2010
  • In this paper, we present the result of investigations pertaining to the development of the floating type photovoltaic energy generation system. Pultruded FRP has superior mechanical and physical properties compared with those of conventional structural materials. Since the FRP has an excellent corrosion-resistance and high specific strength and stiffness, the FRP material may be highly appreciated for the development of the floating type photovoltaic energy generation system. In the paper, we discussed the development concepts of the floating type photovoltaic energy generation system, briefly. The mechanical properties of the FRP structural member used in the development are investigated through the tensile and compression tests. Test results are used in the finite element analysis and the design of the system. In addition, bolted connections of the members are briefly discussed and the strengths of FRP bolted connections are estimated based on the results of experiments. The experimental results are compared with the finite element analysis results and discussed briefly. The floating type photovoltaic energy generation system is designed, fabricated, and installed successfully in site.

  • PDF

Re-evaluation of Force Transfer Mechanism of Reduced Beam Section (Dogbone) Seismic Steel Moment Connections (보 플랜지 절취형 (독본) 내진 철골모멘트 접합부의 응력전달 메카니즘 재평가)

  • 이철호;김재훈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.221-230
    • /
    • 2003
  • Employing classical beam theory for the design of RBS seismic steel moment connections was brought into question in this study, Both the experimental strain data and analytical results from the calibrated finite element analysis confirmed that the shear transfer mechanism in the RBS connection is completely different from that as predicted by classical beam theory Plausible explanations of a higher incidence of brittle fractures observed in the specimens with bolted-webs were presented. It was pointed out that the practice of providing web bolts uniformly along the beam depth is not consistent with the load path identified by both experimental and analytical results. More rational bolted-web details were proposed based on the identified principal load path,.

  • PDF

Design of corrugated sheets exposed to fire

  • Sokol, Zdenek;Wald, Frantisek;Kallerova, Petra
    • Steel and Composite Structures
    • /
    • v.8 no.3
    • /
    • pp.231-242
    • /
    • 2008
  • This paper presents results of fire tests on corrugated sheets used as load bearing structure of roofs of industrial buildings. Additional tests of bolted sheet connections to the supporting structure at ambient and elevated temperatures are described. Three connection types were tested and their resistance, stiffness and deformation capacity was evaluated. Finite element simulations of the corrugated sheet based on the experimental observations are briefly described and design models are presented.

Effect of bolted splice within the plastic hinge zone on beam-to-column connection behavior

  • Vatansever, Cuneyt;Kutsal, Kutay
    • Steel and Composite Structures
    • /
    • v.28 no.6
    • /
    • pp.767-778
    • /
    • 2018
  • The purpose of this study is to investigate how a fully restrained bolted beam splice affects the connection behavior as a column-tree connection in steel special moment frames under cyclic loading when located within the plastic hinge zone. The impacts of this attachment in protected zone are observed by using nonlinear finite element analyses. This type of splice connection is designed as slip-critical connection and thereby, the possible effects of slippage of the bolts due to a possible loss of pretension in the bolts are also investigated. The 3D models with solid elements that have been developed includes three types of connections which are the connection having fully restrained beam splice located in the plastic hinge location, the connection having fully restrained beam splice located out of the plastic hinge and the connection without beam splice. All connection models satisfied the requirement for the special moment frame connections providing sufficient flexural resistance, determined at column face stated in AISC 341-16. In the connection model having fully restrained beam splice located in the plastic hinge, due to the pretension loss in the bolts, the friction force on the contact surfaces is exceeded, resulting in a relative slip. The reduction in the energy dissipation capacity of the connection is observed to be insignificant. The possibility of the crack occurrence around the bolt holes closest to the column face is found to be higher for the splice connection within the protected zone.

Shake Table Test on Seismic Performance Evaluation of the Bolted Connection Type Paneling System with Exterior Finish Material (외부마감재가 부착된 볼트접합 방식 패널링 시스템의 내진성능평가를 위한 진동대 실험)

  • Oh, Sang Hoon;Park, Jong Won;Park, Hae Yong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.23-32
    • /
    • 2018
  • In this study, we conducted a shake table test to verify the seismic performance of the paneling system with steel truss composed of bolt connections. The control group was set to the traditional paneling system with steel truss connected by spot welding method. Test results showed that the bolted connection type paneling system has excellent deformation capacity without cracking or brittle fracture of the steel truss connection parts compared to the welding type paneling system. Furthermore, in the bolted connection type, slight damage occurred at the time of occurrence of the same story drift angle as compared with the existing method, it is considered that it has excellent seismic performance. In compliance with the performance-based design recommended for the current code (ASCE 41-13) on non-structural components, it is judged that in the case of the bolted connection type paneling system, it can be applied to all risk category structures without restriction. However, in the case of traditional paneling system with spot welding method, it is considered that it can be applied limitedly.

Seismic Design and Testing of Reduced Beam Section Steel Moment Connections with Bolted Web Attachment (웨브를 볼트로 접합한 보 플랜지 절취형(RBS) 철골모멘트접합부의 내진설계 및 성능평가)

  • Lee, Cheol Ho;Kim, Jae Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.6 s.79
    • /
    • pp.689-697
    • /
    • 2005
  • Recent test results on reduced beam section (RBS) steel moment connections show that specimens with a bolted web connection tend to perform poorly due to premature brittle fracture of the beam flange at the weld access hole. A review of previous test results indicates that the higher incidence of base metal fracture in bolted-web specimens is related, at least in part, to the web bolt slippage and the high stress concentration at the weld access hole with the lowest material toughness. The practice of providing web bolts uniformly along the beam depth based on the classical beam theory is questioned in this paper. A new seismic design procedure, which is more consistent with the actual load path identified from the analytical and experimental studies, is proposed together with improved connection details. A test specimen designed following the proposed procedure exhibited a cyclic connection rotation capacity sufficient for special moment frames without fracture.